computer servers Computer Servers ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values Specification Form Factor Rack Rack Size (RU) 2 - Processor Make Intel Intel Max. Number of sockets available on chipset 2 2 Max. Number of sockets populated with processor 2 Number of core per Processor 8 As per GeM Catalogue. Processor Configuration Intel Xeon Silver 4108( 1.80GHz/8-core/11MB/8 5W) Intel Xeon Silver 4108( 1.80GHz/8-core/11MB/8 5W) Chipset compatible with CPU C621 - Availability of Co- Processor No - If Yes Co-Processor Configuration NA As per GeM Catalogue. PCI Slots (Express Gen 3.0) 8 - Type of RAM DDR4 - 1/4 RAM Size (GB) 32 32 RAM upgradable upto (GB) 3072 DIMM Slots (No.) 24 - Type of Hard Disk Drive SAS SAS Hard disk drive Capacity (GB) 4500 4500 Hard disk drive Speed (RPM) 15K - RAID Controller Cache (MB) 2048 - RAID Type 5 - RAID Controller Ports @12 Gbps 8 - Video Controller (support VGA or above resolution) Yes - Keyboard No - Mouse No - Bays (min. 2 internal or more hot plug) 16 - USB Ports (version 2.0/3.0) 5 - Certifications Compliance support by Windows
Red Hat or Novell. or Oracle Cluster S/W Yes - DVD ROM (or better) 8x or better - Network Card Supported 10G - FC HBA Dual port card NA - FC HBA Dual port card Speed NA - Power Management - - Redundant Power Supply Yes - Redundant Fan Yes - Total No of Ports 4 x 1G - Declare SPEC int_rate_base 2006 & specfp_rate_2006 for 1
2
4
8 prcessor as - - 2/4 applicable. Server scalability to be achieved within the box without adding nodes Yes - RoHS Compliance Yes - BIS Registration number & its Validity - - Max. power consumption of the system (Watt) 750 - Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a Dry heat test (For 16 hrs at a temperature of 45 degree C in accordance with IS: 90 00/part-3/section-5/197 7) b Cold test(For 4 hrs at a temperature of 0 degree C in accordance with IS: 9000/part-2/sec tion-4/1977 c Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temperature of 40 degree C & 95% RH in accordance with IS: 90 00/part-5/section-1/198 1) Note:- The server shall be checked for all the parameters before conditioning
After completion of the above environmental tests sequence
with a recovery period of 1 to 2 hrs
the server shall be functional Yes - Name address of Lab - - Test Report No. date - - Power Supply 230 V +/-10%
50 Hz - On Site OEM Warranty (years) 5 5 * Bold specifications are the golden parameters. Consignees and Quantity 3/4 S.No. Consignee Address Quantity Delivery Days 1 Prajwal Khare 452001
Devi Ahilya Vishwavidyalaya
Nalanda Campus
R. N. T. Marg
Indore (M.P.)
India Pin- 452 001 2 15 Required No ePBG Required No