Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-Finance GANDHIBAGH NAGPUR NAGPUR NAGPUR NAGPUR MAHARASHTRA 440002 | NAGPUR | MAHARASHTRA | 440002 | L1 | Accepted-Finance L1 | |
| 2 | L2Accepted-Finance BUDHAR ROAD SHASTRI NAGAR SHAHDOL MP | SHAHDOL | SHAHDOL | MADHYA PRADESH | 484001 | L2 | Accepted-Finance L2 | |
| 3 | L3Rejected-Finance 106 C SECTOR B SANWER ROAD INDORE 452015 | INDORE | INDORE | MADHYA PRADESH | 452015 | L3 | Rejected-Finance L3 | |
| 4 | L4Rejected-Finance OLD POST OFFICE BUILDING MAIN ROAD BIRSINGHPUR PALI DISTT UMARIA M P | BIRSINGHPUR PALI | UMARIA | MADHYA PRADESH | L4 | Rejected-Finance L4 | |
| 5 | Rejected-Technical 36 HARI SHANKAR SHAH JAYNAGAR POST SHAHPUR WAIDHAN SINGRAULI M P 486886 486886 SINGRAULI MADHYA PRADESH 486886 | SINGRAULI | MADHYA PRADESH | 486886 | - | Rejected-Technical Disqualified due to non submission of Tender cost n EMD |
| Sl No | Description | Qty | Unit | Naushad and Brothers L4 | INDTOOLS SALES AND SERVICES L3 | MANJEET TRADERS L2 | M/S PUNJAB MACHINE TOOLS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | WAGON TIPPLER Cooler Fan Motor
2.2 KW, (3HP) X 2880 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- BLE 90L, DE6205-C3/ NDE 6205, Amp.-4.2 | 2 | Nos | 37,034 ₹43,700.12 | 27,470.1 ₹32,414.72 | 24,058.2 ₹28,388.68 | 23,072.56 ₹27,225.62 Lowest |
| 2.00 | SAC cooler motor
2.2 KW, (3HP) X 1410 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- FC 00206, DE6206-C3/ NDE 6205ZZ, Amp.-4.7 | 1 | Nos | 19,505 ₹23,015.9 | 15,593.55 ₹18,400.39 | 13,031.02 ₹15,376.6 | 12,660.73 ₹14,939.66 Lowest |
| 3.00 | W.T. Hyd. Cooler
2.2 KW, (3HP) X 1410 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- FC 89655, DE6206-C3/ NDE 6205ZZ, Amp.-4.7 | 1 | Nos | 19,505 ₹23,015.9 | 15,593.55 ₹18,400.39 | 13,031.02 ₹15,376.6 | 12,660.73 ₹14,939.66 Lowest |
| 4.00 | W.T. Hyd. Pilot Pump
3.7 KW, (5HP) X 1500 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- 112M. | 1 | Nos | 27,027 ₹31,891.86 | 20,639.85 ₹24,355.02 | 17,335.64 ₹20,456.06 | 17,276.61 ₹20,386.4 Lowest |
| 5.00 | Apron Feeder Cooler Motor
2.2 KW, (3HP) X 2880 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- BLE 90L, DE6206-C3/ NDE 6205ZZ | 1 | Nos | 18,517 ₹21,850.06 | 13,735.05 ₹16,207.36 | 11,556.42 ₹13,636.58 | 11,536.28 ₹13,612.81 Lowest |
| 6.00 | Dribble Feeder Drive
5.5 KW, (7.5HP) X 715 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- 160M, Amp.-12.3 | 1 | Nos | 74,072 ₹87,404.96 | 60,175.5 ₹71,007.09 | 56,702.41 ₹66,908.84 | 48,734.51 ₹57,506.72 Lowest |
| 7.00 | D.R.C. Hydraulic Power Pack
5.5 KW, (7.5HP) X 1440 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- DP M132S, DE6308/NDE6208, Amp.-11 | 1 | Nos | 36,130 ₹42,633.4 | 27,944.7 ₹32,974.75 | 26,254.95 ₹30,980.84 | 23,438.22 ₹27,657.1 Lowest |
| 8.00 | Sump pump
22 KW, (30HP) X 1475 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- ND180L, DE63102 RS, Amp.-39 | 1 | Nos | 1,22,404 ₹1,44,436.72 | 88,695.6 ₹1,04,660.81 | 74,344.08 ₹87,726.01 Lowest | 80,635.06 ₹95,149.37 |
| 9.00 | Conveyor 20 A/B
37 KW, (50HP) X 1480 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- ND225S, DE63132 RS, Amp.-63 | 1 | Nos | 1,87,415 ₹2,21,149.7 | 1,31,335.05 ₹1,54,975.36 | 1,19,397.15 ₹1,40,888.64 | 1,15,078.33 ₹1,35,792.43 Lowest |
| 10.00 | Flap Gate motor
1.5 KW, (2HP) X 680 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, DE6206/NDE6206, Amp.-5.2 | 1 | Nos | 38,556 ₹45,496.08 | 21,439.95 ₹25,299.14 | 18,036.58 ₹21,283.16 Lowest | 18,387.19 ₹21,696.88 |
Tender Value
₹6.8 L
EMD Value
₹13,600
Closing Date
18 Sept 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE PnW
SE PnW
Procurement of various type LT Motors for WT system at SGTPS MPPGCL Birsinghpur
2024_MPPGC_349367_1
349367
Open Tender
Miscellaneous Goods
Item Wise
90 days
SE PnW, SGTPS, Birsinghpur
As per NIT
18 documents required · 18 mandatory
₹500
Yes
₹13,600
Yes
3 Feb 2026
5 Aug 2024
23 Sept 2024
5 Aug 2024
18 Sept 2024
5 Aug 2024
WAGON TIPPLER Cooler Fan Motor 2.2 KW, (3HP) X 2880 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- BLE 90L, DE6205-C3/ NDE 6205, Amp.-4.2
SAC cooler motor 2.2 KW, (3HP) X 1410 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- FC 00206, DE6206-C3/ NDE 6205ZZ, Amp.-4.7
W.T. Hyd. Cooler 2.2 KW, (3HP) X 1410 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- FC 89655, DE6206-C3/ NDE 6205ZZ, Amp.-4.7
W.T. Hyd. Pilot Pump 3.7 KW, (5HP) X 1500 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- 112M.
Apron Feeder Cooler Motor 2.2 KW, (3HP) X 2880 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- BLE 90L, DE6206-C3/ NDE 6205ZZ
Dribble Feeder Drive 5.5 KW, (7.5HP) X 715 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- 160M, Amp.-12.3
D.R.C. Hydraulic Power Pack 5.5 KW, (7.5HP) X 1440 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- DP M132S, DE6308/NDE6208, Amp.-11
Sump pump 22 KW, (30HP) X 1475 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- ND180L, DE63102 RS, Amp.-39
Conveyor 20 A/B 37 KW, (50HP) X 1480 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- ND225S, DE63132 RS, Amp.-63
Flap Gate motor 1.5 KW, (2HP) X 680 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, DE6206/NDE6206, Amp.-5.2
D.E. Screw Conveyor 0.75 KW, (1HP) X 1390 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Amp.-1.9
D.E. Flap Gate/RAL. feeder motor 0.37 KW, (0.5HP) X 1380 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Amp.-1.12
D.S. Solenoid Pump 11 KW, (15HP) X 1465 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- ND160M, DE6309/NDE2RS, Amp.-20
D.S. Feed Water Pump 1.5 KW, (2HP) X 1405 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- ND90L, DE6205/NDE2RS, Amp.-3.4
D.S. Metering Pump 0.37 KW, (0.5HP) X 1350 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- AD71, DE6203/NDE2RS, Amp.-1.2
E.O.T. Long Travel Motor 3.3 KW, (5HP) X 850 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- ILT3314-6, DE6206/NDE6206, Amp.-8.6
E.O.T. Cross Travel Motor 1.5 KW, (2HP) X 870 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- ILT3017-6, DE6206/NDE6206, Amp.-5
Ventilation System 02 7.5 KW, (10HP) X 1465 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- ND160, DE6309/NDE6309, Amp.-14
Ventilation Water Pump 1.5 KW, (2HP) X 1405 R.P.M, 415+/-6%, 50Hz +/-3%, 3Phase , TEFC, IP55, AMB -45oc, class-F, B5, Frame size- ND902, DE6205/NDE6205, Amp.-3.4
MANJEET TRADERS (BID ID -1095190)
INDTOOLS SALES AND SERVICES (BID ID -1088138)
Naushad and Brothers (BID ID -1086752)
MANJEET TRADERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .