Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 CrAccepted-Finance | ₹5.8 Cr | L1 | Accepted-Finance L1 bidder |
| 2 | L2₹6.0 Cr+₹19.1 L (3.26%)Rejected-Finance ERODE 638012 | ERODE | ERODE | TAMIL NADU | 638012 | ₹6.0 Cr+₹19.1 L (3.26%) | L2 | Rejected-Finance Not L1 bidder |
Tender Value
₹5.0 Cr
EMD Value
₹10.1 L
Closing Date
9 May 2022, 3:00 pmClosed
Executive Engineer (Civil),
Office of the Executive Engineer (Civil), Engineering unit, Admin. Building, 3rd Floor, IIT Madras, Chennai- 600 036.
Construction of new building (G Plus 1 Floor) for Cryo facility at IITM
2022_IITM_113078_1
03/ 2022-23 / Composite
Open Tender
Civil Works
Item Rate
180 days
IIT Madras
As mentioned in the tender condition
2 documents required · 2 mandatory
₹0
₹10.1 L
Administrative Building, 3rd Floor,
14 May 2022
18 Apr 2022
10 May 2022
18 Apr 2022
9 May 2022
27 Apr 2022
18 Apr 2022 - 25 Apr 2022
25 Apr 2022
Amount
CIVIL WORKS EARTHWORK EXCAVATION
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with M-sand under floors,footings including watering, ramming, consolidating and dressing complete.
Intercarting of excavated earth by mechanical transport including loading, unloading and stacking / spreading / leveling lead up to 2.5km beyond the initial lead of 50m. Voids will be deducted at 20%.
CEMENT CONCRETE & REINFORCED CEMENT CONCRETE WORKS
Providing and laying in position ready mixed plain cement concrete, All works upto plinth level with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. M-10 grade plain cement concrete (cement content considered @ 220 kg/cum).
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M35 grade with minimum cement content of 380 kg /cum
Footing
Column & Wall - Sub Structure
Grade beam
Plinth beam
Floor slab
Isolation flooring
Trench
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M35 grade with minimum cement content of 380 kg /cum
Column & superstructure
Lintel at 2.1m lvl
Roof Beam - G.F
Roof Beam - F.F
Roof Beam - H.R & LMR
Roof Slab - G.F
Roof Slab - Mezzanine
Roof Slab - 1st floor
staircase Waist slab
Wash basin counter, Sill Beam
RCC Wall
OHT wall
Extra for providing M35 self compacting concrete instead of conventional M35 CC (SI.No 9.01 & 9.12)
Providing centring shuttering and form work for RCC works for all applicable RCC items in this schedule using best quality of film coated plywood / MS Sheets centring and shuttering materials, for required heights and sizes in all floors and all levels as indicated in the drawings including charges for demoulding agent, removal of form work etc complete at all levels. The rate inclusive of application of demoulding agent over the centring materials. The finishing of the concrete surface shall be without any undulations and surface defects. Note : No plastering will be permitted over the exposed concrete in ceiling. For All Shapes of Concrete
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies.
FAIR FACED CONCRETE FINISHE FOR EXPOSED AREA AND FORM FACED CONCRETE FINISH FOR INSIDE AREA CONCRETE SHUTTERING SPECIFICATION Providing and fixing formwork to obtain fair face finish concrete :-. The exposed RCC wall for the proposed work shall be 900 mm above FFL to top of the wall with a average height of 8.90 m ht. No plastering or other external finish is permitted over the demoulded surface. The exposed area need to have a pattern of grooves as shown in drawing. The internal surface of these walls shall be form finish and external surface shall be with fair finish. The formwork shall be designed with the embedded pattern on outside shuttering and the same shall be approved by engineer in charge. The shuttering for the exposed wall shall be with film coated marine plywood and the rate is inclusive of applying necessary demoulding agent / releasing agent. The maximum permissible reuse for the panels for the shuttering shall be restricted to 4 times only. The scaffolding and form supports shall be as per good construction practices to obtain required finish and to cater the requirment of SCC concrete. The shuttering shall be designed to pour the concrete for full height floor to floor. The horizontal bracing using tie bolt, spring coil and metal cone in wall shuttering, for the deep pour shall be provided. The rate inclusive of designing the formwork to withstand the pressure of SCC (if needed) and additional measures to get fully exposed concrete finish. The detailed surface finish requirement for the fair face concrete is indicated in Annexure II)
REINFORCEMENT Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
MASONARY BLOCK Masonry work with M10 grade fly ash concrete blocks of Size (230x110x70) in MM in foundation and plinth all shapes and sizes cement mortar 1:6( 1 cement 6 coarse M-sand)
Masonry work with M10 grade fly ash concrete blocks of Size (230x110x70) MM in Superstructure above plinth level up to floor V level all shapes and sizes cement mortar 1:6 ( 1 cement 6 coarse M-sand)
Half brick Masonry work with M10 grade fly ash concrete blocks of Size (230x110x70) MM in Superstructure above plinth level up to floor V level all shapes and sizes cement mortar 1:4 ( 1 cement 4 coarse M-sand). The rate is inclusive of providing and placing in position 2 Nos 8mm dia TMT bars at every third course.
PLASTERING Prepare surfaces and plaster with CM 1:3 (1 cement: 3 fine M-sand) 6mm thick to all ceiling area (only for beams) in RCC surfaces contiguous to masonry in super structure in all heights. The rates including curing, providing and removal of hacking, scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc including curing all complete as directed by Engineer-in-charge at all levels. 6mm Cement Plaster - for beams
Prepare surfaces and plaster with CM 1:4 (1 cement: 4 fine M-sand) 12mm thick to all interior faces of walls including hacking as required on RCC surfaces, and fixing double layer chicken mesh in the junction of RCC beam and brick masonry at least 100mm on either face (total 200mm high) filling packed these junctions , The rates including curing, providing and removal of scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc including curing all complete as directed by Engineer-in-charge at all levels. 12 mm cement plaster - Internal
Plastering of External wall 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse M-sand) finished with a top layer 6mm thick cement plaster 1:3 (1 cement : 3 coarse M-sand) finished rough with sponge. Rate shall include for providing drip bands / moulds / grooves to any size and shape as directed. 18 mm cement plaster - External
Providing and fixing plaster mesh of 80 GSM glass fibre mesh (non-alkaline) between concrete and brick masonry. The rate inclusive of labour, scaffoling, SS nails for fixing the mesh etc., complete.
PAINTING Providing and applying 2 coats of Wall Care Putty (JK/Birla / Altek or equivalent, total thickness not less than 2mm) having water absorbtion less than 0.5%, making it smooth over plastered surface (should be in line & level) including cleaning & removing loose particles over the surface & proper pre wetting the surface before applying putty. ( Internal wall)
Applying super premium quality 100% interior Acrylic emulsion paint (ICI /Asian / Berger / Nippon / Nerolac) : Two or more coats including one coat of primer. Applying interior paint of approved colour, make, brand and product with surface coverage of painting as per the manufacturer specification (as given in Annexure 1.3). The interior paint shall be applied over dry surface and powdery residue using mechanical methods with Zero dust vaccum technology followed with sealing the surface with a coat of approved interior primer before application of interior paint. The contractor should ensure complete covering of floors using tarpaulin / plastic sheet while taking up the work. The rate quoted shall be inclusive of charges towards all labour, material, transport, scaffolding, safety arrangements, Personal Protective Equipments (PPE), tools and plants etc. Two or more coats over one coat of primer
Applying super premium quality 100% Exterior Acrylic (Asian / ICI /Berger / Nippon / Nerolac) emulsion : Two or more coats including one coat of exterior primer. Applying exterior paint of approved colour, make, brand and surface coverage of painting as per the manufacturer specification (as given in Annexure 1.1). The exterior paint shall be applied over dry surface and powdery residue using mechanical methods with Zero dust vaccum technology followed with sealing the surface with one coat of approved exterior primer before application of exterior paint. The contractor should ensure complete covering of floors using tarpaulin / plastic sheet while taking up the work. The rate quoted shall be inclusive of charges towards all labour, material, transport , scaffolding, safety arrangements, Personal Protective Equipments (PPE), tools and plants etc. The Paint manufacturer shall inspect the work in every stage, submit inspection / field test report, certify the product / application and give 10 year Guarantee. Two or more coats over one coat of primer
Enamel painting for doors / windows / wall panels (two or more coats including a coat of primer) on both exterior and interior surface of wooden and steel joineries using approved colour, make and brand of synthetic enamel paint two or more coats over a coat of primer as per Annexure A.1.4. (Top coat enamel coverage not less than 8.83sqm per litre for two coats over a coat of primer as per manufacturers specifications). The contractor should ensure complete covering of floors using tarpaulin / plastic sheet while taking up the work. The work shall be executed as per the detailed specifications. The rate quoted shall be inclusive of charges towards all labour, material, transport, scaffolding, safety arrangements, Personal Protective Equipments (PPE), tools and plants etc. (Asian (Premium Gloss Enamel) / Berger Luxol High Gloss Enamel / ICI (AkzoNobel) Gloss Enamel / Nerolac / Nippon Hi Gloss Enamel).
JOINERY Fully Glazed Door with Patch Fittings Supply & Fixing of ALTERRA ALT 50 Frameless Glass Door (Single Leaf) with toughened glass and door accessiories Frameless door Rebate Profile all around the door. Rebated Door Frame size 50x54mm design. Hardware - Dormakaba junior Office Hinges(3 nos) ,Studio Gala Locks (1no) in aluminium silver (EV1) finish and Dormakaba TS 89 Slide Channel Door closer with (as per EN 1154) and saddle plate for fixing on the Glass door . Glass Mounted Sweep seal or Door Bottom Seal. In case of Glass overpanel OHP100-SG Over Panel Door profile to be used.The hardware should be suitable for Glass thickness of 10/12mm.The Profile finish shall be as per Approved Architects specifications.Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 1.5 mm Gauge thickness Excluding 20 Micron of Anodizing. Max Door Height - 2700mm. Max Door Weight - 80 Kgs Door of Size 1.20 m X 2.10m & 1.0m & 2.1m
Providing and fixing Automatic Sliding door operator, Make: DORMAKABA ES 200 (EASY) 6250 or equivalent product of HAFEE/ OZONE, compliant with future European standards and produced according to the guidelines for power-operated windows, doors and gates, BGR 232, the UVV and the VDE regulations. TÜV design tested for Durability of 1,000,000 Cycles, Manufactured according ISO 9001, tested according to the low voltage guidelines, CE Compliant, fulfils DIN 18650 standards for Padestrian Safety, for framed glass door application with DORMA ST-Flex Profiles Systems, modular design including internal cover and with 12.52 mm Laminated glass for 1 Nos sliding door panels and 1 Nos fixed panels, both sliding & fixed panels with DORMAKABA ST-Flex framed profile system with Interlocking Seals.Operator & Frame Finish should be Silver Anodised, with operator dimensions (H x D) : 100 x 180 mm and of length as required to suit the opening sizes as given below. DORMAKABA ES200 Operators are of very sturdy design with Self balancing Panel suspension system and with Anti-Jump fitting.The track profile should be separate from the main profile for enabling reduction in vibration insulation. Microprocessor-controlled control unit, Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force, reversing when obstruction is encountered, Class of protection IP 20 with SMPS for Power regulation. Activators- DORMAKABA Nemo Motion + Nemo Dual ( Safety & Motion ) Pack, EM Lock - Fail Safe with CableProgram Switch with Key. Max Panel Weight Carrying Capacity of 1 X 200 Kgs. The system shall have constant power supply 230V+ 5%, 50Hz, AC . The requirement in total is as mentioned below: Clear Opening width of 2500x 2400 mm(W X H)
For Frame : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters -Providing and Fixing colour anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS :733 and IS 1285, fixed with rawl plugs and scews or with fixing clips, or with expansion hold fasterns including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / Stainless steel screws, all complete as per architectural drawings and the directions of Engineer - in- charge. (Glazing and panelling to be paid for separatelly) For Shutters Anodised aluminium (anodised transport or colour anodized dyed to required shade according to IS 1868, Minimum andioc coating of grade AC 15)
Supplying and fixing of Tinted glass 8mm thick for glazed portion along with sun control fim of approved colour and make as required in Aluminum doors including removing the damaged with necessary fittings etc complete
Providing and fixing 6 mm thick fibre cement board over existing aluminium/ wooden frame partition
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
ACCESSORIES Providing and fixing Stainless steel butt hinges (heavy weight) 100x60x2.5 mm IS : 12817 marked
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing Powder coated minimum thickness 50 micron aluminium tubular handle bar
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-incharge. With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing Factory made single extruded WPC (Wood Polymer Composite) solid door/window, clerestory windows & other Frames/Chowkhat of frame size 65 x 125 mm also Factory made single extruded WPC (Wood Polymer Composite) solid plain white colored board of 25 mm thick neatly fixaed to the door frame with necessary accessaries and hardware as required neatly and complete. Factory made single extruded WPC (Wood Polymer Composite) solid plain white colored board of 25 mm thick
Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete : 250x20x6 mm
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS:3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately). ( Including FRAME)
Single leaf door - 1.00 x 2.10 m
Single leaf doors - 1.20 x 2.10 m
Shaft door (450mm x 1200mm)
Providing and Fixing Casement UPVC Ventilator by Aluplast / AMD or approved equivalent make made of (small series) frame 60 x 45 mm ( Frame 119396 ) having wall thickness of 2.2 ± 0.2 mm and reinforcement should be at 1.2mm thickness , Glass should be pin head 4mm louvers type with neccessary hardwares etc, all complete as per manufacturer's specification and direction of Engineer-in-charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing & fixing Toughened glass of 12 mm thickness below the SS handrails with nesseccary SS studs / screws and etc..as per the drawing
STRUCTURAL GLAZING Semi unitized Structural Glazing System Scope: Designing the Semi unitized structural glazing system as per design intent and as per approved drawings, preparation of shop drawings, supply, fabricate the panel with the specified glass on the child frame at factory, erect the system on erected extruded main frame & Transom fixed on supporting system at site as per approved shop drawings at all floor levels and for all heights. Designing, providing and fixing frame supporting system, the framing system (i.e. Main & Child frame) to support Vision panels (Insulated Glass) / Spandrel panels either with Monolithic Glass / laminated glass or Laminated M-sandwiched composite panel (ACP),/openable Top hung window panels/ punched strip windows to any shape & profile, smoke seal, flashing including gaskets, sealants necessary accessories, as part of the system on a continuous framing supported between floors as detailed below and as per the specification for external facade system. Design the split framing semi unitized glazing system in case of Punched windows with vision panel proposed with either Insulated/Monolithic Glass as specified maintaining groove width shall not be more than 16 mm both in horizontal and vertical. Conducting the test for the materials involved in the system, field test on the erected system at site as per the test criteria set out in the specification of External Facade system. Submission of methodology for the Materials and assembly (Mock up & field test) supported by the copy of relevant codes & Standards and the same shall be got approved by the Engineer incharge prior to testing. Protection of the System and Materials till handing over to the Engineer In charge, removal of the unwanted materials, broken glass, Screws, bolts, Nuts, Packing Materials, debris etc., regularly and keeping the premises neat and clean at all times.
Coordinate the details of the façade cleaning system during the preparation of shop drawing and incorporate such details in the shop drawing submitted for approval of Engineer In charge. Maintaining the system by means of periodical inspection at site (bi-monthly) and checking the system and Materials involved in the system during Defects liability period (this will not relieve the contractor from the condition laid down in the contract under defects liability period) to ensure that the system and all materials are free from any defects during this period. Providing the Guarantee for the entire External Façade system to the specified period in an approved format supported with Back to back guarantee from the specialized Material supplier like Glass, Aluminum composite panel, Gasket, Sealant, Hardware etc. complete as directed by Engineer In charge. I.DESIGN: a. Design: Design pre-assembled aluminum Semi unitized Structurally glazed Panel with continuous framed panels / Strip window / Punched window system with split mullion to any shape and profile to satisfy the structural design criteria (Minimum wind pressure shall be 200 Kg/Sqm) as per IS code or relevant international code) (Test pressure shall be 1.5 times of the design wind pressure) and fixed at horizontally / vertically / sloped / curved position etc. as shown in the approved drawings by using Aluminum extrusions, Glass, Spacer tape, Gasket, Sealant etc. as specified.
Contractor shall be responsible to determine the maximum design wind pressure and lateral forces, moments, stresses etc. applicable for the system. Negative / suction pressures if determined as per IS 875 and Lateral forces as per code IS 1893 shall make allowances as described in the code for corner effects on the system. System shall be designed with Air Pressure equalization chamber and concealed continuous gutter vertically and horizontally at all levels as self drainage barrier to achieve water tightness besides providing EPDM Gaskets on the frame and EPDM Gasket / Sealant on the external groove as air and water barrier. b. System: System shall be designed to satisfy the structural design criteria specified with self-bearing modular elements supported between floors (Supporting span of minimum 3.20 meter with 2 transom connection on each mullion) in the case of structural glazing and split mullion supported between RC Members, EPDM Gaskets on the frame and Gasket/sealant on the groove to prevent the system from Air & water penetration ,double adhesive spacer tape, backer rod, sealant, supporting brackets (Resistance to design wind pressure), Separator Gaskets for Bi-Metallic Corrosion, Pressure equalization chamber in the system, built-in continuous internal drainage gutter for collection and facility at lowest floor level to drain out penetrated water, in built adjustability to accommodate thermal expansion, thermal movement and movement due to any other forces etc.
System shall be designed with Gasket/Sealant on the external groove with colour anodized aluminum holder around the panel to the required width and thickness as per design as Dead load support to the Glass panel. Non Staining sealant between glass & aluminum holder around the panel shall be provided. Glazing the panel with child frame shall be done only at factory at the controlled atmosphere to erect the panel on erected extruded aluminum main member and transom with supporting system at site fixed on the RC surface. The Mullion and sill / head Transom flush on inside of the facade. Intermediate transoms shall be provided keeping 2 to 3mm recessed from the inner face of the mullion. Joints between mullion and transom shall be filled with weather sealant on the inside. All transoms shall have uniform in depth on the inner face of the system. Full size mullion shall only be used in all cases including peripheral members, peripheral members shall have sub frame (sash) on both sides in such way to hold the glass on one side and flashing / peripheral flashing on the other side. Vertical in-situ glazing shall not be carried out during construction/erection stage. System shall be designed in such a way that the outer surface of insulated glass unit, monolithic glass unit and any type of metal panel shall be in the same plane or as per approved drawing. Aluminum shim shall be used for level adjustment of bracket but more than 20 mm is not acceptable. If more than 20 mm bracket shall be designed according to site condition. Aluminum cleat shall be used for fixing the glazing shall be minimum size of 50 mm long and spaced at 450 mm as maximum and each cleat shall have minimum 2 SS screws and the screws shall be soaked with weather sealant.
c. Movement: System shall be designed to accommodate movement due to any force including lateral/dynamic pressure movement, horizontal & vertical building movement panels and on the framing system with support brackets, gaskets and fastening devices. System shall be designed to accommodate the size and shape of the glass panel as per the approved drawings including approved modifications as may be required during execution as well as all other incidental forces and stresses likely to be experienced under service conditions, i.e. Lateral force, Dead weight and Thermal expansion due to building movement both vertical and horizontal etc. The supporting system shall consists of Brackets / Clamps, fastening straps, nuts, bolts, rivets, washers and other fastening materials etc. Extruded sections shall be designed to accommodate Insulated Glass Unit (IGU) / Monolithic (Single) Glass and Aluminum composite panel as per the approved shop drawings. Extruded aluminum sections shall be 63400 (H9) grade conforming to IS 8147, finished with AC25 grade Architectural quality electrolytic colour anodic coating of approved colour conforming to IS 1868.
d. Glass: Supply of glass either Insulated glass, Double or Monolithic glass as per the options given in Schedule of quantities to the respective place to fix the glass on the system. Fixing the glass shall form part of the system cost quoted under respective items. Spacer for Insulated glazing unit shall be aluminum extruded profile and finished with AC 25 grade electrolytic colour anodic coating of black colour conforming to IS 1868 and filled with dry desiccant. Primary sealant shall be Poly-isobutylene (PIB) and Secondary seal shall be structural silicon sealant of DC 995 (one part) or DC 983 (two parts) of Dow corning or approved equivalent. Make and thickness of Inner pane glass shall be the same make as outer pane glass of IGU/DGU. However all the glass panes are shall be heat strengthened and the protection of glass as specified shall be responsible of the Bidder/Processor. Processing of Glass: Details of the processor and their facilities should be submitted to the Employer/PMC/Architect for approval. Insulated glazing unit shall be processed only by the approved Processor. All glass panes used in the glazing shall be heat strengthened conforming to ASTM C 1048. No tong marks shall be allowed in the processed glass. Necessary test certificate shall be produced by the processor to confirm the adherence of the parameters set out in the codes and standards. New substrate glass shall only be used for coating and to ensure the same, a certificate shall be produced by the contractor. Making necessary arrangement to inspect the Glass processor by the representative of Employer, PMC and Architect (one representative from each as minimum) during the progress of glass processing.
Glass Manufacturer shall ensure that only new substrate glass is used for coating and necessary inspection procedure shall be adopted to eliminate the incidence of Nickel sulphate (NIS) inclusion on the float glass used for coating and to ensure the same, a certificate from glass Manufacturer shall be obtained by the contractor and submit the same to Engineer-in-charge. Contractor shall arrange for obtaining necessary clearance from the processor for the inspections of the glass processing plant during the progress of glass processing and to carry out the random test (Minimum 3 nos) at the glass processor lab by Engineer-in-Charge. It shall be the responsibility of the contractor to make sure that the glass shall be processed as per specification and it shall be conforming to the criteria of the respective codes and standards. The contractor shall have to submit certificate from the glass processor that the glass processing has been done as per specification and codal provisions has been observed and such copy of codes shall be made available for verification of Engineer In charge. Processor shall provide removable Safety clips on each corner of glass and provide self adhesive plastic sheet to the required thickness on the external surface of the glass as a safety measure prior to packing to avoid breakage of glass in the corners during transit, free from scratches and this safety clip shall be retained till the glass is taken for Glazing in to the frame at factory and plastic sheet shall be retained till handing over the project. Glazed panel with broken or Chipped off glass at the edges and with any scratch on the surface of the glass shall not be allowed to use in the Facade and found any such damages in the glazed panel even after glazing / erected in place shall be rejected and shall be replaced with new one after the approval of installation methodology by Engineer In charge
e. Gaskets: Providing and fixing weather barrier to ensure the air & water tightness at minimum 3 stages barrier and to ensure that the system is thermally broken systems in addition to the Non staining weather sealant on the exposed screws. The first barrier exposed to weather condition shall be Elastomer silicon synthetic rubber manufacture by oven process at different stages conforming to BS or equivalent IS. The properties of Elastomer silicon synthetic rubber such as hardness, tensile strength elongation compression test & ozone resistance shall be in accordance with BS 903 & BS 903A minimum hardness (shore A) of Elastomer silicon synthetic rubber shall be 65 to 75 Deg and the weather strip with in the system for unexposed shall be Elastomer EPDM (Ethylene Propylene Dinine Monomer) synthetic rubber and its properties like hardness, expanded density (Specific gravity) compressive set, water absorption, skin surface, cell structure, ozone resistance, low temperature includes work shall be in accordance with ASTM D – 1056 and minimum hardness ( Shore A ) shall be 61/71 Grade.
f. Sealing: Design bite and thickness of structural sealant to withstand 3 times of the stress caused by the design wind pressure specified above and to ensure the same, the design calculation of sealant manufacturer shall be submitted along with shop drawing. Necessary materials as proposed in the shop drawing such as Extruded member with finish, glass and any other material required by the Sealant manufacturer shall be supplied to them to carryout the test as per relevant codes & standards in order to validate the bite and thickness designed by them. Contractor shall obtain the test certificate from Sealant manufacturer and submit the same along with shop drawing and supported by the copy of relevant codes and standards. Contractor shall ensure that the bite and thickness of sealant as designed & determined by calculation, verified and tested by Manufacture's is followed in the shop drawing and the same shall be adopted for the glazing at factory after the approval of shop drawing. Field test shall be conducted for adhesion of sealant with in the quoted rate.
Supplying and fixing the Sealant as per specification and Double Adhesive spacer tapes for glazing the panel at factory. Spacer tape shall be open cell of code no. V 2200 of Nortan Grind well make or approved equivalent, Jointing / Sealing of the glazed panel at factory shall be done with Non structural (weather) sealant / Non staining sealant of DC 991 HP of Dow corning make or approved equivalent with Polyurethane baker rods of Supreme make or approved equivalent. Acetoxy sealant shall not be used for Structural Glazing application. In general, providing and fixing the Structural and non Structural (weather) sealant shall be as follows:
Shop / Factory Sealants:
i) Structural sealant shall be DC 995 (one part) or DC 983 (Two part) of Dow corning make or approved equivalent.
ii) Non-Structural (weather) sealant shall be DC 991 HP of Dow corning make or approved equivalent.
Field Sealants:
i) Structural Sealant shall be DC 995 (one part) of Dow corning make approved equivalent.
ii) Non-Structural (weather) sealant shall be DC 991 HP of Dow corning make or approved equivalent.
g. System Supports : Providing and fixing the supporting system with Brackets / Clamps including fastening straps, nuts, bolts, rivets, washers etc. as per design requirement and as per approved shop drawing. Brackets / Clamps shall be of hot dip galvanized steel and fastening materials shall be Non - magnetic Stainless steel 300 series - 316 grade of Hilti make or approved equivalent. Galvanizing thickness shall be in accordance with IS 2629 and 4759. Providing and fixing serrated plates or serrated washer wherever required as per the system requirement and as shown in the approved shop drawing. Shim thickness beyond 20mm is not permitted. Shims shall be similar material, preferably with aluminum, not more than 20mm thick and if the variation is beyond 20 mm, the bracket shall be designed accordingly with fastener.
h. Smoke seal: Providing and fixing Smoke seal / Fire stop using extruded aluminum channel / tray / sheet for continuous structurally glazed framing system with required thickness as per site and in general the thickness of channel / tray / sheet shall be 1.2 mm and to a width as required at transom level and below sill finish material (Natural stone / Plywood by interior) and it shall be 63400 (H9) grade conforming to IS 8147, finished with AC25 grade Architectural quality electrolytic colour anodic coating conforming to IS 1868 of approved colour. Aluminum colour anodized extruded channel / tray / sheet shall be supported with the help of Aluminum bracket as designed and this bracket to be fixed on the wall / RCC surface with necessary SS anchor bolt and fastener of Hilti make or approved equivalent.
This channel / tray / sheet shall be provided between Sill finish Material (under respective agency scope) and Curtain wall / structural glazing member at sill level and between RCC member face and structural glazing member at soffit level / false ceiling and etc. complete. All the Joints between the capping channel and any other finish material at both sill and soffit level shall be sealed with Intumescent sealant of 3M or Hilti make.
g. Flashing: Providing and fixing flashing on the unexposed area at required levels including peripheral of glazing and window as part of the system (applicable only for continuous structural glazing portion) made to profile (both horizontal & vertical) as shown in the approved drawings and the profile shall be made out of hot dip galvanized sheet 1.2 mm thick and galvanizing coating thickness shall be in accordance with IS 2629 & 4759 and all exposed flashing shall be 1.2 mm thick aluminum anodized / powder coated sheet shall be considered. In general, the flashing shall be provided to the entire length of Curtain wall / structural glazing portion horizontally at all floor levels, vertically and at terrace level with a overlap of 100 to 125 mm in plan and the joints shall be sealed with weather silicon sealant and with recessing anchoring system soaked and SS fastening devices in sealant of Hilti make or approved equivalent.
Also, the flashing shall be provided at parapet top below the coping to drain the water during any seepage through the sealant joints with overlap of 100 to 125 mm in plan with sealant at joints to make sure that no water leakage through coping / flashing joints.
h. Insulation on spandrel panel: Providing and fixing Mineral wool slab - 60 Kg/cum - confirming to EN 13501-1) and having 'K' value of 0.035 w/Mok - 50 mm thick - Thermal Rock of Rockwool India & Middle East make on the spandrel panel area i.e, behind the ACP / glass and for smoke seal at sill level. These wool should be covered with Black tissue factory pressed - 0.50 mm thick (Nominal Mass - 60 Kg/cum) to conform Non combustibility Class - fire rating to BS 476 - part 7 & IS 3808 and fixed by using Aluminum Angle / channel of required size as base and the wool shall be tied with 22 gauge G.I. wire in criss-cross manner into Aluminum angle / tray to the structure in addition to the G.I wire the black anodized aluminum flat of 25 mm wide and 2 mm thick spaced not more than 300 mm shall be provided to hold the insulation in position and shall be covered with 1.0mm thick G.I sheet with exterior grade powder coated finish.
The aluminum flat shall be fixed over aluminum tray having minimum fold 25 mm on all four sides by using 2 Nos of pop up rivet on each side with same colour of flat. Rock wool should be fixed to the main aluminum frame work between mullion & transom on each side with the gap of 25 to 30 mm from the inner surface of the glass (i.e behind the spandrel panel glass area). The measurement shall be made only between mullion & transom on each side of the inner surface of system.
j. Top hung Openable window Hardwares: Providing and fixing the hardware's for the shutter with heavy duty self balancing stainless steel friction hinges, corner transmission, detachable restrictor stay assembly and Multi point locking with heavy duty mechanism (minimum 9 points including corner locking point), handle with key at centre of the transom having a ceremony. Handle / cremony shall be made out of aluminum die cast with powder coat finish - 65 microns, matching to the transom profile colour. Rate shall include the shutter frame as designed to accommodate the Hinge, stay arm and multi point lock, EPDM gaskets, fastening materials including all other necessary materials etc. Hinge shall have thermoplastic asymmetric end cap to ensure weather tight sealing at the ends.
Rate shall exclude cost of Glass and main frame, but include cost of sub frame for shutter and the frame to be designed to fix all the hardware's specified like heavy duty self balancing stainless steel friction hinges of Model no SPT 26, Corner Transmission Model no 9312, corner locking point model no 9313 and restrictor stay arm assembly model no SRD 8 with release key of model no R 7437 of Securestyle (UK) make or pre approved equivalent make and Multi point lock (minimum 9 point) and handle / cremone size of 110 x 27mm with key of Model no 610 K of Alualpha make or pre approved equivalent make. Shutter will have a provision for hold open option and to restrict the opening not more than 200 mm and to keep the vent weather tight while closing the shutter. Compressible Gaskets shall be designed to ensure the air and water tight including noise control while the shutter is closed in position and the gasket shall be silicon synthetic rubber of required strength. Rate shall include for providing master key - 3 sets (floor wise) & Grand master key - 3 sets (building wise) for openable with necessary coding engraved on the keys etc., complete..
k. Provision: System design in total, shall have the provision to fix the Door integrating with glazing system with necessary structural supports cladded with specified materials and necessary hardware's etc. complete and fixing the doors shall be form part of the over all system. Note: Door item shall be operated as specified in Bills of quantities.
1. Swing / Openable door: Designing, providing and fixing Aluminum framed door as per the specification given in the BOQ with necessary accessories and hardware's etc. of Gaze make or approved equivalent make.
l. Visual mock up: Providing and fixing full scale visual mock-up with minimum 3 bays with openable window, ACP cladding, smoke seal and other special architectural features etc., to establish the actual system design prior to proceeding with full scale production of the materials involved in the system. Conduct a water test on the installed visual mock up system, (only water using hose real to the specified pressure) and submit the test result of the system for review. Rate shall include for any improvements required on the system based on the test result by the Glazing contractor.
l. Visual mock up: Providing and fixing full scale visual mock-up with minimum 3 bays with openable window, ACP cladding, smoke seal and other special architectural features etc., to establish the actual system design prior to proceeding with full scale production of the materials involved in the system. Conduct a water test on the installed visual mock up system, (only water using hose real to the specified pressure) and submit the test result of the system for review. Rate shall include for any improvements required on the system based on the test result by the Glazing contractor.
m. Field Test: Conduct Field test at site on the installed glazing system as per the criteria set out in the specification of the external facade system and as per the Methodology described in ASTM 501-2. Test shall be carried out in the presence of Employer/PMC/Architect. Methodology for carrying out the test shall be submitted to Architect for approval prior to testing. The results shall be recorded and the reports shall be submitted to the Engineer in charge for approval. If Field test fails, contractor shall submit the rectification methodology to correct the defects as per the performance data set out in the Specification of external facade system and as per the methodology described in the relevant code for the approval of PMC/Architect .Defects, if any noticed shall be rectified to the satisfaction of Engineer In charge.
n. General : System design in total, including Aluminum extruded frames, type & thickness of Glass pane, Aluminum sleeves at connections, inserts, EPDM Gaskets / Silicon rubber, Adhesive tapes, Sealant, Supporting system / bracket including fastening and anchoring system & Materials specified in the schedule and the system details as shown in the tender drawing are only tentative and is meant to set out a general outline of the Proprietary system and minimum requirements/ properties of the system and component parts.
The general guidelines governing the system design and performance parameters as set out in the Specification relating to External Façade System and the contents therein. Since the External Façade system in terms of Design, materials, all fixing details, methodology of execution are proprietary in nature, the onus of the design and Performance requirements, shop drawing, execution etc. satisfying the design intent and specification of external facade system including conducting the site survey prior to and after preparation of shop drawing and accommodating the site conditions in the system at appropriate levels etc. lies solely with the Contractor.
p. Mode of Measurement: Length and breadth of the superficial area of the finished work shall be measured centre to centre of the grooves on the external surface viewed externally correct to a centimeter under the respective items. Areas shall be calculated in a square meter correct to two places of decimal.
q. Rate. Quoted rate shall include the cost of all materials and labour involved in all the operations as specified above, specified in the external facade system, to execute the work as per approved drawings / shop drawings including, scaffolding, infrastructure facility, tools and plants etc. necessary for execution of the respective item for all height and for all floor levels, Item measurable in sqm. Rate shall include the cost of field test, visual mock up, supplying & fixing of glass, fixing of window hardware, but rate shall exclude the cost of Insulation on spandrel, supply of doors, supply of hardware for top hung window which will be measured separately and paid under respective item given below.
Semi unitized system with Vision panel (System with Glass): Designing, providing and fixing Semi Unitized structural glazing vision panel & vision on spandrel panel structurally held in position by Structural sealant and factory fabricated with Aluminum adaptor of suitable size in order to satisfy the structural design criteria specified above. In general, the system comprising Aluminum anodized extruded frames & Adapters supported on the brackets (spanning 3.2 M as minimum), Toggle cleats, HDG brackets & SS anchors and bolts, flashing etc. with Insulated glass of 26 mm thick having 6 mm thick Reflective coated glass on # 2 surface with ST 467 green of Saint Gobain make or Meadow Green SN 49/38 of Asahi Make as outer pane and 12 mm airgap and 8 mm thick glass uncoated clear as inner pane of same make. Both panes are shall be heat strengthened.
Rate shall exclude the cost of Offsite proto type test, supply of top hung window hardware's with window subframe and insulation, which will be measured and paid separately under the respective item below. Rate shall include for supplying and fixing of glass, fixing of Top hung window hardware's with shutter frame, aluminum mullion and transom, visual mock up and field water test etc.
Semi unitized system with Spandrel panel (System with Glass): Designing, providing and fixing Semi Unitized structural glazing vision panel & vision on spandrel panel structurally held in position by Structural sealant and factory fabricated with Aluminum adaptor of suitable size in order to satisfy the structural design criteria specified above. In general, the system comprising Aluminum anodized extruded frames & Adapters supported on the brackets (spanning 3.2 M as minimum), Toggle cleats, HDG brackets & SS anchors and bolts, flashing etc. with Monolithic glass having 6 mm thick Reflective coated ST 467 green of Saint Gobain make or Meadow Green SN 49/38 of Asahi Make. All the panes are shall be heat strengthened.
Rate shall exclude the cost of Offsite proto type test, supply of top hung window hardware's with window subframe and insulation, which will be measured and paid separately under the respective item below. Rate shall include for supplying and fixing of glass, fixing of Top hung window hardware's with shutter frame, aluminum mullion and transom, visual mock up and field water test etc.
Semi unitized Glazing with Punched / Strip window System (with Glass): Designing, providing and fixing Semi Unitized structurally glazed punched / strip window system with structurally held in position by Structural sealant and factory fabricated with Aluminum adaptor of suitable size in order to satisfy the structural design criteria specified above. In general, the system comprising Aluminum anodized extruded frames & Adapters, aluminum sub frame & L - Angle around the windows, Toggle cleats, Aluminum flat around the window (For windows at PEB location) HDG brackets & SS anchors and bolts, flashing & smoke seal around the window etc. with Insulated glass of 26 mm thick having 6 mm thick Reflective coated glass on # 2 surface with ST 467 green of Saint Gobain make or Meadow Green SN 49/38 of Asahi Make as outer pane and 12 mm airgap and 8 mm thick glass uncoated clear as inner pane of same make. Both panes are shall be heat strengthened.
Rate shall exclude the cost of Offsite proto type test, supply of top hung window hardware's with window subframe and insulation, which will be measured and paid separately under the respective item below. Rate shall include for supplying and fixing of glass, fixing of Top hung window hardware's with shutter frame, aluminum mullion and transom, visual mock up and field water test etc. Also rate shall include the cost of aluminum sub frame with L - angle, weather sealant and Intumescent sealant, providing visual mock up and conducting field water test.
Hardware for top hung window: Quote extra rate over & above the Curtain wall glazing / window item for designing and supplying of hardware's for top hung openable outward shutter having Heavy duty Multi point lock with required points based on the window panel size and handle with or without key with detachable handle of Model no 610 K / 670 of Alualpha make or approved equivalent make, locking point - Typhoon lock of kinlong make, SS friction hinges of Model no SPT 26, Corner Transmission Model no 9312, corner locking point model no 9313 and restrictor stay arm assembly model no SR 8 with release key of model no R 7437 of Securestyle (UK) make or approved equivalent make and as per particular specification. Rate shall exclude cost for supplying and fixing of glass and main frame, but include cost of hardware's and sub frame for shutter. System to be designed to with stand design wind pressure of 200Kg/Sqm confirming to IS 875 part 3 and other load parameters specified and other load parameters specified as per IS / Relevent international codes.
Insulation for Spandrel: Quote extra rate over & above the Curtain wall glazing / window item for designing and supplying Insulation with Back pan having Mineral wool slab - 50 Kg/cum - confirming to EN 13501-1) and having 'K' value of 0.035 w/Mok - 50 mm thick - Thermal Rock of Rockwool India & Middle East make confirming to ASTM 177, 518 / IS. 3346) laminated between factory pressed Black glass tissue and the insulation slab shall be covered both side with 1.0mm thick G.I sheet with exterior grade powder coated sheet with fold around to a height of 25mm minimum to fix the stiffener flat and as thermal insulation to be fixed behind Spandrel area / ACP Cladding area as mentioned. All the edges between tray and frame to be sealed with Non-Staining weather silicon sealant of approved make. System to be designed to with stand design wind pressure of 200Kg/Sqm confirming to IS 875 part 3 and other load parameters specified and other load parameters specified as per IS / Relevent international codes.
Supply and installation of Noise S.T.O.P Fabrisorb Wall Panel – Thickness 25 mm and Size – Custom made as per site measurement upto 1200 mm x 2400 mm. Core is made of Rigid Fibreglass insulation 96 kg/m3 with tissue facing on both sides. Edge Hardened Fabric Acoustic Panels have no internal frame. Fabric wrapped around panels using Fire Retardant Adhesive. (Fabric is made of 100% Polyester – Class A Fire Treated with Flammability as per ASTM E84 Class 1 or A Width 54 inches, Weight- 375 Grams/Metre ±5%, Abrasion Resistance 80000 Cycles, Colour Fastness Wet:4 , Dry: 5, Colour Matching, Batch to batch variations in shade may occur within commercial tolerances. Anti- Microbial / Anti-Fungal AATCC 147. Maintenance - Daily dusting & vacuum cleaning, weekly wet cleaning). Acoustic Properties - NRC 0.80 with Type A Mounting. ( AHU ROOM )
Providing and laying Granite stone flooring / skirting in single size or in combination of different sizes as per approved drawings with not less than 18 mm thick mirror polished granite of approved colour, shade and texture with cement slurry spread at the rate of 4.4 kg of cement per sqm over an average thickness of 20mm cement mortar 1:4 (1cement : 4 coarse M-sand) including finishing the joint with white cement and matching pigments with approved shade from approved sourse all complete as per direction of Engineer in charge. Rate shall include for preparation of base surface & finished the surface, protection with gypsum/POP layer over plastic sheet and removing the same before handing over, work at all levels, as directed. ( FLOOR ) With not less than18mm thick Granite stone slab area 0.50 Sqm and above of single slab Paradiso, SilverPearl, Sable brown, Ivory fantasy, Tan brown, juprano, steel grey, lavender blue pearl white,chikku brown, viscon white, pearl grey, kashmir white or equivalent shades ( BASIC COST 185 - 200 / SFT)
Providing and laying Granite stone flooring / skirting in single size or in combination of different sizes as per approved drawings with not less than 18 mm thick mirror polished granite of approved colour, shade and texture with cement slurry spread at the rate of 4.4 kg of cement per sqm over an average thickness of 20mm cement mortar 1:4 (1cement : 4 coarse M-sand) including finishing the joint with white cement and matching pigments with approved shade from approved sourse all complete as per direction of Engineer in charge. Rate shall include for preparation of base surface & finished the surface, protection with gypsum/POP layer over plastic sheet and removing the same before handing over, work at all levels, as directed. ( SKIRTING ) - ( BASIC COST 185 - 200 / SFT)
Providing and laying Antiskid Vitrified floor tiles of size 600 x 600mm, 9mm thick of 1st quality conforming to IS : 15622 of approved make in all colours, shades, laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Coarse M-sand) and filling the joints of 3mm spacer with laticrite epoxy grouting and matching pigments etc. all complete as per Particular Specification and as directed by Engineer incharge. Rate shall include for preparation of base surface & finished the surface, protection with gypsqm/POP layer over plastic sheet and removing the same before handing over work, and tile spacer etc., at all levels, as directed. ( Toilets ) ( BASIC COST 70- 80 / SFT)
Providing and fixing Ist quality Vitrified wall tiles 1200 x 600mm conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse M-sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.(Toilets) ( BASIC COST 80-90/ SFT)
Providing and fixing Ist quality Vitrified wall tiles 1200 x 600mm conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse M-sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.(Toilets) ( BASIC COST 80-90/ SFT)
Providing and fixing Granite stone in risers of steps, skirting and dado in single size or in combination of different sizes with not less than 18 mm thick plolished granite of approved colour, shade and texture, from approved sourse over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse M-sand ) as per approved pattern / design and jointing with grey cement slurry @ 3.3 Kg. per sqm. including pointing with filler compound or approved equivalent, to matching shade as per Manufacturer's Specification, including edge chamfering and polishing the chamfered edge to give highly smooth surface, & groove to the specified size of 2nos - 3mm @ 25mm c/c from the edges, rubbing and polishing complete. curing, protection, scafolding and preparation of base surface etc. complete as per direction of Engineer in charge. Rate shall include for protection with gypsum / POP layer over plastic sheet and removing the same before handing over,work at all levels, as directed. With thickness not less than 18 mm Granite stone slab area up to 0.60 Sqm Paradiso, SilverPearl, Sable brown, Ivory fantasy, Tan brown, juprano, steel grey, lavender blue pearl white,chikku brown, viscon white, pearl grey, kashmir white or equivalent shades. (BASIC COST 185 - 200 / SFT)
Providing and fixing Acrylic solid surface counters for Toilet wash basin / Pantry sink in Dark shade from approved manufacturer, counter to a minimum width of 600mm and to a specified height along with moulded wash basin sink to shape and with 200mm depth facia, the thickness of solid surface for counter top shall be 12 mm, the back splash and facia shall be 6 mm thick. but in general the solid surface top shall be placed over the RCC counter of required thickness and it shall be measured and paid separately under relevant items .Rate shall be inclusive of providing any cutouts in the counter for accommodate the water supply inlet and drainage outlet connections and fittings etc.Mode of measurement : Measured in Square metre 12 mm thick
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse M-sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine M-sand, including necessary excavation, levelling & dressing & finishing the top smooth.
WATER PROOFING WATER PROOFING TREATMENT SYSTEM FOR THE ROOF TERRACE out involving the following items, sequences and specifications. a) Polymer modified mortar :- Resurfacing of the substrate with Sika Latex (or MIXBOND SBR of FABCHEM, Rheomix 141 of BASF or Nitobond SBR of FOSROC) polymer modified cement mortar (Cement: M-sand ratio : 1:3 with a Water (Mixed with Sika Latex) cement ratio of 0.4-0.45), with a minimum thickness of 20 mm, to get a levelled surface. The dosage of Sika Latex will be 4 kgs per bag of cement. The rate should be inclusive of bonding coat with cement and latex mix of ratio 1:1 over the cleaned surface before application of mortar. b)Treatment to rain water mouth / Khura- making opening for fixing the rain water pipe with a diameter of the opening should be more than 25cm around the rain water pipe to be fixed. The new rain water pipe to be fixed to the opening after installing swellable acrylic based PU water bar around the pipe, fixing the rain water pipe to the opening made and filling the gap between the rain water pipe and the opening with non shrink grout without any gap, applying a layer of cementitious water proof coating over the rainwater floor mouth (The rate also inclusive of applying a layer of cementitious coating Cement : SBR 1:1 ratio over the wall floor junction before applying coving) and finishing the surface neatly.
c) Providing gola / coving 75x75 mm in cement concrete 1:2:4 admixed with 4 Ltr of SBR latex for 50 kg of cement (1 cement : 2 coarse M-sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 admixed with 4 Ltr of SBR with 50 kg of cement (1 cement : 3 fine M-sand) as per standard design. The rate also inclusive of applying a layer of cementitious coating Cement : SBR 1:1 ratio over the wall floor junction before applying coving. d) Supply and applying PU moist cured- Supplying and laying single component PU system using spray application only with MC-HYPERDESMO or equivalent product of SIKA / BASF/ ASIAN PAINT / FOSROC is a one component polyurethane fluid which cures with the humidity in the atmosphere. It produces a highly elastic membrane with strong adhesion to many types of surfaces. It is based on pure elastomeric hydrophobic polyurethane resin plus special inorganic fillers, which result in excellent mechanical, chemical, thermal, UV and natural element resistance properties. Apply with airless spraying in two, at least, coats with minimum total consumption of 1.5-1.8 kg/m2 or as specified by the manufacturer. The rate inclusive of necessary surface preparation to receive the waterproofing coating etc., complete.
e)Ponding test by storing water for a minimum depth of 20 cm and the water to be retained for not less than 48 hours or as required by engineer in charge to ascertain any leakage. Necessary repair / grouting to be done free cost to arrest any leakage observed. f)Geotextile:- Supply and apply a polyester based geotextile protection fleece. Product: Sarnafelt® 300 or equivalent approved by IITM. Product requirements: density ≥ 300 g/m2; thickness 2.4 mm; tensile strength ≥ 430 N/50mm; elongation at break ≤ 100 %; tear strength ≥ 250 N; puncture resistance ≥ 1600 N; cone drop: 13 mm. g)Providing and laying light weight concrete of grade not less than M2.5 using expandable polystyrene aggregate to maintaining adequate of density 800-900 kg/ cum and same shall be laid to maintain slope to drain the rain water over the geotextile (not less than 1 in 80).
The minimum cement contnent shall not less than 250 Kg/cum. The mix design shall be approved by the engineer incharge. Minimum thickness of the concrete shall be 5cm. h)Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 9.5 mm) manufactured by ABC or equivalent with SRI (solar refractive index) > 78, solar reflection >0.70 and emittance >0.75 on 30 mm thick cool mortar as per manufacturer specification on sloped surface of terrace, laid on water resistant cement slurry prepared in the ratio of 1:3 ( 1 cement and 3 abc plus powder and add 3% Nano Acryl by volume) and grouting the joints (>3mm) with abc Grout and PPF (Poly Propylene Fiber) in the ratio of 2 to 3 gm PPF per kg of abc Grout including wetting (by using a piece of sponge) the grouted surface by abc Nano Clear in the ratio of 100 ml in two liter water. , including providing skirting upto 300 mm height along the parapet wall in the same manner.
OHT Water Proofing Finishing with water proofing plastering of polymer modified mortar of CM 1:4 (1 Cement : 4 fine sand / M sand) of 20 mm in two coats ( each coat of 8+12mm thick) admixed with Nitobond SBR @ 6lts per bag of cement including applying PU solvent free waterproof coating using solvent free food grade Hyperdesmo-2k-w or Mariseal 300 with roller or brush in two coats with consumption per coat of 0.7kg/Sqm for vertical surface and 1.4kg/Sqm per coat for floor area.The rate is inclusive of surface preparation of tank walls & floor and If required neccessary cement grouting including Cement Slurry admixed with Flowcable 50 – Non-shrink grout additive @ 250gms per Cement bag including all materials and labour charges etc. complete as per direction of Engineer Incharge.
TOILET Water Proofing Polymer modified mortar:-Resurfacing of the substrate with Sika Latex (or MIXBOND SBR of FABCHEM, Rheomix 141 of BASF or Nitobond SBR of FOSROC) polymer modified cement mortar (Cement: M-sand ratio : 1:3 with a Water (Mixed with Sika Latex) cement ratio of 0.4-0.45), with a minimum thickness of 20 mm, to get a levelled surface. The dosage of Sika Latex will be 4 kgs per bag of cement. The rate should be inclusive of bonding coat with cement and latex mix of ratio 1:1 over the cleaned surface before application of mortar. The rate inclusive treatment to drainage line by making opening for fixing the rain water pipe with a diameter of the opening should be more than 25cm around the rain water pipe to be fixed. The new rain water pipe to be fixed to the opening after installing swellable acrylic based PU water bar around the pipe, fixing the rain water pipe to the opening made and filling the gap between the rain water pipe and the opening with non shrink grout without any gap, applying a layer of cementitious water proof coating over the rainwater floor mouth (The rate also inclusive of applying a layer of cementitious coating Cement : SBR 1:1 ratio over the wall floor junction before applying coving) and finishing the surface neatly.
Over the plastered surface Supplying and applying ( MIXGUARD HR-5 or equivalent product of SIKA/ FOSROC/ BASF) cold applied elastomeric water proof membrane over the prepared surface, prepare a base surface stabilizing primer (MIXPRIME AC100 @ 2 : 1 : 3 (MIXPRIME AC100 : WATER : OPCEMENT) and apply directly (@ 1KG/SQM) along with MIXMAT GFM-50 at an overlapping of 50mm minimum After a curing period of 3-4 hours prepare and apply MIXPRIME AC @ over at a consumption of 250ML/SQM. After curing of 3-4 hours apply a coat of MIXGUARD HR – intermediate elastomeric water proof coat at consumption of 0.5KG/SQM. After a curing time of 4-5 hours apply MIXGUARD HRXtra - Micro fibre reinforced high tensile top coat at consumption of 0.5KG/SQM. Leave 72 hours time for complete system curing. Total build up DFT of the system will be 1700 microns.
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure, such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm dia
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2.5 Rectangular shape 600x450 mm internal dimensions
Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately).
Galvanized Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing HPL cladding below sheet work of approved pattern and colour as required neatly and complete.
Providing expansion joint in RCC floor slab for 40mm width using polyurethane sealent on the top and bottom for a depth of 20mm each and packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying poly sealent with necessary spatula etc., complete complying with standard specifications and as directed (FOSRAC/SIKA/BASF)
Hire charges for providing temporary barricading around the site using GI corrugated sheet (to a height not leass that 6m). The GI corrugated /plain sheets of 0.35mm thick shall be fixed to the framework made out of 50mm dia MS pipe for vertical strut placed at about 3m centre to centre with required bracing using 40mm dia MS pipe placed about 2m centre to centre and fixing diagonal middle braces using 25mm dia MS pipe forming a rigid frame work as per the architectural drawing and direction of Engineer-in-charge. The barricade shall remain in the same location till the completion of the new work construction project. No additional charges shall be paid for the extended period of contract. The rate quoted shall be including cost of conveyance of all required materials to work site, erecting, removing and disposing the same after completion of work, cost of J bolts washers, cement concrete bed 45cm x 45cm x 75cm in CC 1:2:4 and labour charges etc., complete as per direction of Engineer-in-charge.
METAL GRID FALSE CEILING Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm andecondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle ofsize 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mmcenter to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Supplying and fixing U-shaped precast drain with cover of size 630x570x500mm with M-40 or higher grade manufactured by M/s Super Precast & Infrastructure or equivalent approved brand.
Supplying and laying precast size of 600x300x75mm saucer drain over 50mm tk mortar bed in side of the road and wherever required in main gate as per direction of Engineer - in- charge.
Providing and laying 80mm thick factory made cement concrete interlocking paver block M-40 grade of made block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over on 50mm thick M-sand filling / Quarry dust with machine compaction well etc. all complete as per direction of Engineer - in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 550mm x 100mm x 1000mm)
SANITARY INSTALLATIONS Providing and fixing white vitreous Bowl type wash basin with necessary sanitary fittings such as 20 mm dia C.P Pillar cock tall and Dlx Braided hose 600mm long of standard pattern, including cutting and making good the walls and labour charges etc. complete. * Basic Cost = washbasin Rs.7000 + GST , C.P.Pillar cock Rs.2450+GST. * Approved Brand Hindware/parryware/jaquar make or equivalent * Ref Model - Italian collection- Amazon min- (Cat No-91093), C.P Pillar cock tall (Model No-F400005 W/Extn Body CP)
Providing and fixing wash basin (counter top or counter bottom) with making good the walls etc. complete. White Vitreous china wash basin 550mm excluding cost of fittings. * Basic Cost = Rs.1484 + GST * Approved Brand Hindware/parryware/jaquar make or equivalent * Ref Model - Oval type 460x342x155mm / Square type 515x380x120mm / Circular 445x445x 195mm
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
Providing and fixing of CP Health Faucet , including all necessary fittings etc. complete as per direction of Engineer-in-charge. * Basic Cost = Rs.950 + GST * Approved Brand Hindware/parryware/jaquar make or equivalent * Ref Model -Model -Hindware Make , Cat No F160023
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineerin-charge.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm
Providing and fixing CP brass paper holder without Cover Plate with CP Brass Screws and etc. complete as per the direction of Engineer In- Charge. * Basic Cost = Rs.1170 + GST * Approved Brand Hindware/parryware/jaquar make or equivalent * Ref Model - (Hindware Make - Model - Rubbic - Cat. No. F870008
Providing and fixing of CP Brass Soap dish with CP Brass Screws and etc. complete as per direction of Engineer-in-charge. (Metro / Parryware)
Providing and fixing white vitreous extended wall mounting water closet of size 64x36x73 Cm and approved shape with necessary fittings, nuts, bolts and gasket etc. complete as per the direction of Engineer in charge. * Basic Cost = Rs.12000 + GST * Approved Brand Hindware/parryware/jaquar * Ref Model - (Cat No-92509-S-30 Water Closet, Seat cover with attached ceramic flushing cistern white colour)
Providing & fixing white vitreous china flat back half stall Urinal (inbuilt spreader) of size 600 x 370 x 390 mm with fittings, standard size C.P. brass flush pipe and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: * Basic Cost = Rs.5150 + GST * Approved Brand Hindware/parryware/jaquar make or equivalent * Ref Model -Model -Flat back Eureka - Hindware make Cat.No-60020
Supplying and fixing CP brass long body two-way bib cock with flange , approved by the Engineer-in-Charge of 20mm dia nominal bore etc. complete. * Basic Cost = Rs.1900 + GST *Approved Brand Hindware/parryware/jaquar make or equivalent * Ref Model - Hindware make Model- Fluid, Cat No -F400003
Supplying & fixing of approved make wash basin sensor faucet with necessary CP flanges etc., complete. (Jaquar Make – SNR-CHR -51021)
Supplying and fixing approved make C.P. Robe hook with C.P. screws etc., complete. Fixed on the toilet door (Jaquar Make - ACN-1161N)
Providing and fixing of CP Brass Towel Ring Metro make with CP Brass Screws and etc. complete as per direction of Engineer-in-charge
Supplying and fixing CP towel rail of size 20mmx600mm long including fixing in position as directed (Metro/Parryware).
Supplying and fixing approved make paper dispenser with necessary fixing materials etc. (Jaquar Make – PTD-SAP-DT0106CS)
Supplying and fixing of Fully Automatic Hand drier of "NOVA-TECH" make fixed near wash basin etc complete.
Providing and fixing of stainless steel matt finished wall mounted Foldaway grab bar for Physical challenged safety handle of size 35x760mm long VIKING or equvalent
Providing and fixing of stainless steel matt finished wall mounted grab bar for Physical challenged safety support handle rail of size 25x600mm long. VIKING or equvalent.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
Providing and fixing C.P. brass long body bib cock with flange , 20mm dia nominal Bore etc. complete as per direction of Engineer-in-charge. * Basic Cost = Rs.1650 + GST * Approved Brand Hindware/parryware/jaquar make or equivalent * Ref Model - Hindware make - Model Fluid - Cat. No. 400002
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
Supplying and fixing of Glass rectangular signage board size of 10 inch and thickness of 20 to 55mm (for Toilets) with CP Brass Screws and etc complete as per the direction of Engineer In- Charge.
INTERNAL & EXTERNAL WATER SUPPLY WORKS Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work
25 mm nominal outer dia pipes
40 mm nominal outer dia pipes
50 mm nominal outer dia pipes
Providing & fixing Chlorinated plolyviny Chloride (CPVC) Pipes, having thermal stabilty for hot & cold wter supply, includign all CPVC plain & brass threaded fittings, i/c fixing the pipe with clampls at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and cost of cutting chases and making good the same including testing of joints, with thermal Insulation complete as per direction of Engineer in charge. Concealed work, including cutting chases and making good the walls etc.
15 mm nominal outer dia pipes
20 mm nominal outer dia pipes
25 mm nominal outer dia pipes
32 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 40 mm nominal outer dia pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : Internal & External
20 mm nominal bore
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore - Vertical
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc, not exceeding 80 mm dia.
Supplying and fixing brass air realease valve of approved make with ISI make including fixing in position, making holes, restoring the damaged portions to original position and applying jointing compound at threaded ends and testing etc. complete as directed. 25 mm dia
SEWERAGE & DRAINAGE WORKS Supplying, laying, jointing, testing and commissioning approved make UPVC pipes class III 6 Kg/cm2 with solvent cement joints confirming to IS 4985 for Wash basin, Sink, Washing machine & Urinal outlets. The quoted rate shall include necessary chisling in walls making good the same in C.M. 1:4, encasing the pipes in toilet sunken and under ground in M-15 as per specifications 100 mm thk. all around with necessary shuttering arrangement, necessary fittings viz.,elbows,tees etc.complete. 50mm dia
Supplying, laying and jointing hard PVC SWR pipes with PVC SWR specials such as tees, bends, door bend, door tee, elbow, unions, etc. with clamp testing the lines rectifying any leakages or defects etc. complete as directed by the Engineer in charge for soil, waste, vent pipe, etc. concealed or open at all levels including cost conveyance of all materials , labour charges, sundries etc. complete for internal work & external works exposed on walls as directed by the Engineer in charge.
75mm dia (6kg / sq.cm)
110mm dia (6kg / sq.cm)
160mm dia (6kg / sq.cm)
Supplying, laying, jointing, testing and comissioning of approved make PVC multifloor trap with cp grating, necessary PVC puddle flanges for floor trap inside toilet & required concrete encasing all around, complete. 110mm x 75mm
Providing and fixing PVC vent cowl to pipe already fixed as directed by Engineer in charge at all levels
75mm dia
110mm dia
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type With Sewer bricks conforming to IS : 4885
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse M-sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 Fine M-sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine M-sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse M-sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
Inside dimensions 455x610 mm and 45 cm deep for single pipe line With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth beyond 45 cm of brick masonry chamber : For 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
For 500x700 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
For 600x850 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine M-sand) including testing of joints etc. complete:
150 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
ELECTRICAL LT INSTALLATION AND ALLIED WORKS SUB HEAD - A:---- L.T. SWITCHGEAR
SUB HEAD -B : MCCBs / MCBs / ISOLATORs / STARTERs etc. Supply, Installation, testing and commissioning of of cubicle type floor mounting/wall mounting isolator panel. The rate shall be inclusive of suitable MS angle ion stand and suitable size enclosure with adopter boxes for cable termiantion,spread bar,etc.
25A DP MCB along with moulded front plate in GI anodized box
100A TPN Isolator (MCCB type) with enclosure for ups /VRF
63A TPN Isolator (MCCB type) with enclosure for ups /VRF
40A TPN (MCB type)
16ADP MCB with STEEL ENCLOSURE
63A TPN RCCB 300MA IP66 with metal power coated steel enclosure for VRF
SUB HEAD -C : DISTRIBUTION BOARDS VTPN 8 WAY (Vertical TPN) MCCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type VTPN 8 way MCCB DB comprising of the following : INCIMER: 63A TPN MCCB 16 KA – 1No. as incomer with ELM OUTGOING: 40A TP MCB 10kA (C-Curve) – 4 Nos.,25 A TP MCB 10kA (C-Curve) – 4 Nos.as outgoings. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc.
LPDB - 6 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following : INCIMER: 63A 4P MCB 10kA with all necessary connected accessories – 1No. 32A DP RCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING: Each 32A DP RCBO outgoing consist of 6nos.6\16\20 A 10KA SP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc.
LDB - 6 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following : INCIMER: 40A 4P MCB 10kA with all necessary connected accessories – 1No. 25A DPMCB WITH 25A DP RCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING: Each 25A DP RCBO outgoing consist of 6nos.6\16\20 A 10KA SP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc.
PDB - 6 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following : INCIMER: 63A TPN MCB 10kA with all necessary connected accessories – 1No. 32A DP RCBO 100 mA – 3 Nos. as individual phase incomers OUTGOING: Each 40A DP ELCB 100MA WITH 40A DP MCB outgoing consist of 6nos.6\16\20 A 10KA SP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc.
UPS DB - 6 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following : INCIMER: 63A TP +2N MCB 10kA with all necessary connected accessories – 1No. 32A DP RCBO 300 mA – 3 Nos. as individual phase incomers OUTGOING: Each 40A DP RCBO outgoing consist of 6nos.6\16\20 A 10KA SP MCB in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc.
DB - 4 WAY MCB INCOMER DB: BASEMENT-Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 4way MCB DB comprising of the following : INCIMER: 63A TP +2N MCB 10kA with all necessary connected accessories – 1No. OUTGOING: 4nos.6\16\20 A 10KA DP MCB in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc.
SPN DB : Supply, fixing, testing and commissioning of the Single door type compartmental 8 way MCB DB comprising of the following : INCIMER: 1no - 16/40A DP MCB, 1 No. OUTGOING: 6 Nos 6\16\20a 10 KA MCB
LDB-STREET LIGHT: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 4 way MCB DB comprising of the following : INCIMER: 1no - 63A TPN MCB, 1 No. 0-24 Hrs. timer with contactor OUTGOING: 2nos - 16/63A TP EL+MCB, 6nos - 6/10A DP EL+MCB With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc.
DB - TPN MCB INCOMER DB: SERVER ROOM-Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 4way MCB DB comprising of the following : INCIMER:25A TP +2N MCB 10kA with all necessary connected accessories – 1No. OUTGOING: 4nos.6\16\20 A 10KA SP/ DP MCB in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc.
SUB HEAD -D :CABLES AND TERMINATION For all items in section-D, the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same
Supply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/aluminium armored & un armored conductor cable partly laid in cable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided
3.5 Core 300 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 35 Sq.mm XLPE Aluminium armoured Cable
4 Core 25 Sq.mm XLPE Aluminium armoured Cable
4 Core 16 Sq.mm XLPE COPPER armoured Cable
4 Core 10 Sq.mm XLPE Aluminium armoured Cable
4 Core 10 Sq.mm XLPE Copper armoured Cable
4 Core 6 Sq.mm XLPE Copper armoured Cable
3 Core 6 Sq.mm XLPE Copper armoured Cable
Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits (copper sockets for copper cables and Alu. Sockets for alum. Cable)
3.5 Core 300 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 35 Sq.mm XLPE Aluminium armoured Cable
4 Core 25 Sq.mm XLPE Aluminium armoured Cable
4 Core 16 Sq.mm XLPE Aluminium armoured Cable
4 Core 10 Sq.mm XLPE Aluminium armoured Cable
4 Core 10 Sq.mm XLPE Copper armoured Cable
3 Core 6 Sq.mm XLPE Copper armoured Cable
SUB HEAD -E :TRENCHING AND EXCAVATION Excavating the ground for a Depth of 0.75 Mtrs for LT cables with required width for laying the LT Cables. After filling the excavated trench with sand of 150mm before and after laying cable Including supply,erecting brick laying over the cables This excavation will be measured for each route only- not for each cables
Supply, laying of 100mm dia HDPE Pipe flexible layed /clamped in the existing wall/ground with suitable supports for street light cable
Supplying, fixing, HT/ LT cable route markers with 10 cm x 10 cm x 5mm. thick CI plate with inscription thereon, bolted / welded to 35mm x 35 mm x 6 mm. angle iron , 60 cm. long and fixing the same in ground as required. The cable route marker shall be fixed at both the ends of cable at joints and at 100 Mts. spacing for straight runs.
Supply,Erection, construction of man hole chamber (cable pull chamber pit) of 1060 x 1060 x 1000mm outer dimension. A masonry structure of wall thickness of not less than 230mm shall be constructed to a depth of 1000mm and heavy duty SFRC cover shall be used to cover the pit. 6 Nos minimum Hume pipes of 150mm dia will be placed in walls as per drawing on three sides. .
SUB HEAD -F :WIRING WIRING - CIRCUIT CUM POINT WIRING The rates for all point wiring items shall also include supplying and fixing of the Conduits, conduit specials, bushes and other fittings,Approved GI saddles and grouting the same for exposed conduit work,2 mm thick Outlet boxes and junction box,All fixing accessories such as clips, brass screws etc,All work & materials necessary for wiring a point circuit of any length from the Final Distribution Board to connector via switch and shall include the circuit wiring also except where identified.
Primary Light / Fan Point Wiring: Supply, wiring, connecting & commissioning of 3Runs 1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded HR-FRLSH-LF copper wires in 1.8mm thick MS conduits fixed on ceiling partly and 1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with moulded front plate in GI anodised manufacturer's mounting box-Flat switches with indication fixed flush with the wall complete with all accessories including 3 plate ceiling rose.NOTE: Above false ceiling when it is open wiring it should be of MS conduit
Secondary Light Points: The secondary light points will have to be wired from the primary light point as mentioned above.
Lighting Circuit Mains: Supply and laying of 3 Runs 2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded HR-FRLSH-LF copper wires in 1.8mm thick MS conduits fixed on ceiling partly and 1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point.
TWO-WAY POINTS SITC of Concealed Point wiring (from Switch board) including Concealed Circuit Wiring (from DB to switch board) for two way like staircase points after cutting grooves on wall/ RCC, neatly filling the grooves with cement mortar, making good thereof, etc. using 3 x 1.5 Sq. mm. heavy duty PVC insulated copper conductor stranded cable (1 for earthing),2 Nos. Modular 2-way switch complete with non metallic inner & outer plates, suitable metal boxes, etc,IS marked (IS 9537 Part-3) suitably sized heavy duty rigid concealed MS conduits (20mm min), Saddles, junction boxes, bends, other accessories, ceiling roses, etc.
Ceiling Fan Points: Supply,installation,testing and commissioning of ceiling fan points same as Primary Light Point Wiring but for ceiling fan points including supplying and fixing concealed type fan hook box and supply and fixing of electronic type 300W fan step regulator with moulded front plate in GI anodised manufacturer's mounting box fixed flush with the wall complete with all accessories as required as per the site conditions.
Ex Fan Points: Supply,installation,testing and commissioning of Ex-fan points same as Primary Light Point Wiring but for exhaust fan points including supplying and fixing one no 6A switch with indicator in switch board and one no 6A socket near Ex fan location in wall with moulded front plate in GI anodised manufacturer's mounting box fixed flush with the wall complete with all accessories as required as per the site conditions. in MS conduits
Emergency Lighting Circuits: Supply and laying of 3 Runs 1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded FRLS copper wires in 1.8mm thick MS conduits fixed on ceiling partly and 1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from ELDB to Emergency Light fittings.
Primary Light / Fan Point Wiring: Supply, wiring, connecting & commissioning of 3Runs 1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded FRLS copper wires in 1.8 mm thick PVC conduit with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with moulded front plate in GI anodised manufacturer's mounting box fixed flush with the wall complete with all accessories including 3 plate ceiling rose.
Secondary Light Points: The secondary light points will have to be wired from the primary light point as mentioned above.
Providing and fixing/ laying of conduit and wires for Light point wiring with 1.5 sq. mm PVC insulated, FRLS, copper conductor (stranded) 1100V grade wires alongwith earthing in 25mm dia. medium duty PVC concealed conduit system including providing and fixing one no. 10 Amp single pole modular switch grid plate mounted with moulded cover plate in zinc chromate passivated GI box suitable for modular switch, complete in all respect (wiring & conduiting up to switchboard not included in item cost), for controlled by 2 nos. 2 way switch. Including making zaries in the wall and finishing the same
Lighting Circuit Mains: Supply and laying of 3 Runs 2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded HR-FRLSH-LF copper wires in 1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point.
SOCKETS Supply, Installation, testing and commissioning of 1 no 6A switched socket and with moulded front plate, GI anodised enclosure, and mounting box in the wall(concealed/open)and other associated accessories including chasing embedding rough plastering as required as per the site conditions for FF all typical floors power points.
Supply, Installation, testing and commissioning of 1 no 6/16A universal switched socket and with moulded front plate GI anodised enclosure in the wall/floor(concealed/open and other associated accessories including chasing embedding rough plastering as required as per the site conditions for F/F and all typical floors power points.
Supply, Installation, testing and commissioning of 2 no 6A UPS switched socket and 2nos6a switches and with moulded front plate, GI anodised enclosure, and mounting box in the wall(concealed/open)and other associated accessories including chasing embedding rough plastering as required as per the site conditions for power points.
Supplying and fixing 25 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Supply, Erection,Testing and commissioning of 32A 3Phase Metal clad plug and socket with 32 A TP MCB as control with enclosure,Plug top cover and connected accessories . Legrand cat no 056614
Supply, Erection,Testing and commissioning of 20A 1Phase Metal clad plug and socket with 20 A TP MCB as control with enclosure,Plug top cover and connected accessories . Legrand cat no 056614
Wiring to the 6/16A 5Pin or 6Amps UPS/Raw power socket using 3C of 2.5 sq mm multi strand PVC insulated Copper conductor (FR-LS) in suitable size MS pipe in open system above false ceiling and concealed system in below false ceiling in wall / column
Wiring to the 6/16A 5Pin UPS/Raw power socket using 3C of 4 sq mm multi strand PVC insulated Copper conductor (FR-LS) in suitable size MS pipe in open system above false ceiling and concealed system in below false ceiling in wall / column etc.
Supply, fixing of 'POPUP BOX : 6M - 2 Nos 6/16A Switch with Socket
Supply & Laying of 2R 4 sq.mm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires 20mm dia 2 mm thick MS conduit with all accessories as reqd. (From DB to 6/16A Power Sockets / 20A Metal clad plug & sockets.).
SUB HEAD -G :LIGHT FITTING Supply of 2'X2' architectural decorative Recess mounted CLEAN ROOM FITTING LED with endorsed lens on each LED and LEDs should be arranged in four rows with 45 deg tilt anlge to cut the glare: CRCA powder coated housing with ABS plastic top cover for better aesthetic finish and high efficient PMMA diffuser on the wall, electronic driver duly wired upto terminal block, Wattage ≤ 30W Luminaire lumen≥ 3000lm, LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and system Efficacy of > 100lm/W, Colour Temperature-4000K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 80, Life of LED as per L70 > 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<10%, Power factor>0.95, Inbuilt Surge protection in CM ≥ 3.0KV, Driver Voltage range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard also driver shall be capable of auto restart post auto shut off if the voltage greater 325V, Electrical Safety with Class 1 Insulation, Luminaire luminous Efficacy≥100lm/W. Driver shall be potted driver and both driver and luminaire shall be BIS compliance. driver shall be potted driver and both driver and luminaire shall be BIS compliance. Driver shall be compatible for auto cut off and restart with deviation to operating voltage also the ripple shall be less 5%.CAT REF.NO :LCTOR-40-CDL OR EQVT
Supply of LED downlighter compatible for cell ceiling with system wattage not more than 18W SQUARE and luminaire lumens not less than 1800 lumens. The system efficacy shall be > 100 lm/W. The housing shall be die-cast aluminium with diffused optics with polycarbonate diffuser for better distribution of light. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of > 150lm/W, Colour Temperature-4000K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 80, Life of LED as per L70 > 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<10%, Power factor>0.95, Inbuilt Surge protection in CM ≥ 2.5KV, LED Driver with Voltage range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard, Electrical Safety with Class 1 Insulation. Driver shall be potted driver with three terminals of P,L,E and both driver and luminaire shall be BIS compliance. Driver shall be compatible for auto cut off and restart with deviation to operating voltage also the ripple shall be less 5%.
Supply of surface LED downlighter system wattage not more than 12W luminaire lumens not less than 1800 lumens. The system efficacy shall be > 100 lm/W, cut out dia shall not greater than 85mm. The housing shall be die-cast aluminium with deep recessed optics with low glare and reflecter shall be matt black in color. Luminaire shall be compatible to access/replace the LED moudle without removing the trim from the ceilng. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of > 130lm/W, Colour Temperature-4000K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 90, Life of LED as per L70 > 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<10%, Power factor>0.95, Inbuilt Surge protection in CM ≥ 2.5KV, LED Driver with Voltage range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard, Electrical Safety with Class 1 Insulation. Luminaire shall be BIS compliance.Driver shall be compatible for auto cut off and restart with deviation to operating voltage also the ripple shall be less 5% CAT REF.NO :WIPRO LD90-231-XXX-65-XX OR EQL
Supply of RECESSED LED downlighter system wattage not more than 18W CIRCULAR RECESS and luminaire lumens not less than 1800 lumens. The system efficacy shall be > 100 lm/W, cut out dia shall not greater than 85mm. The housing shall be die-cast aluminium with deep recessed optics with low glare and reflecter shall be matt black in color. Luminaire shall be compatible to access/replace the LED moudle without removing the trim from the ceilng. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of > 130lm/W, Colour Temperature-4000K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 90, Life of LED as per L70 > 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<10%, Power factor>0.95, Inbuilt Surge protection in CM ≥ 2.5KV, LED Driver with Voltage range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard, Electrical Safety with Class 1 Insulation. Luminaire shall be BIS compliance.Driver shall be compatible for auto cut off and restart with deviation to operating voltage also the ripple shall be less 5% CAT REF.NO :WIPRO LD90-231-XXX-65-XX OR EQL
Supply of IP65 4' LED luminaire with special application luminaire shall be designed to provide undisrupted lighting for dusty and humid indoor application. The luminaire shall be with all-weather polycarbonate housing and highly efficient electronics with LED system to offer long useful life even in adverse application and environmental conditions. The luminaire shall be with Co-extruded polycarbonate housing and mounded end caps. The system wattage shall be < 36W with system lumens of > 4400 lumens and system efficacy of > 100 lm / W. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of > 150lm/W, Colour Temperature-6500K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 70, Life of LED as per L70 > 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<10%, Power factor>0.95, Inbuilt Surge protection in CM ≥ 4.0KV, Constant Current - Constant Voltage LED Driver with APFC Construction, LED Driver Voltage range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard, Electrical Safety with Class 1 Insulation.
Supply, Installation, including assembling, testing and commissioning of Wall mounted light fitting with 9W or 10W LED lamps and sutable drivers for Mirror light fitting.
Supply, Erection, testing and commissioning of Cove/Strip light with 1 x 20W EACH 5M LED COOL white with driver and with all accessories and interconnecting with 3 core 1.5 sqmm PVC insulated multistrand wires and accessories as required.Crompton cat no LST20CDL/BL/WW
Orient Electric 10W LED Inverter Emergency Batten (White, Square)
Suspended linear in sleek design comes with multiple dimensions SUSPENDED LINEAR CROMPTON LCLP54-36-CDL
Supply, Installation, testing and commissioning of 1200mm sweep BLDC Ceiling fan and fixing the same with extended rod from roof, required clamps,bolts,fan hook , screws ,hardwares as required as per the site condition -BEE 5 Star rated white colour double ball bearing including 2 Module modular stepped regulator
Supply and fixing of Bulk head fitting of PHILIPS make CAT: Philips 10 W WT202W LED6S CW PSU S2 PC Endura LED Bulkhead, 6500 K (or) Crompton cat ICBH10 OR equivalent in the lift shaft.
Supply, Installation, testing and commissioning of heavy duty motor totally enclosed with die cast aluminium rotor mounted on two ball bearings 300 mm dia1400 RPM single phase Exhaust fan with die cast Al body and CRCA steel blades and minimum air delivery of 1710 cum/hr. and fixing the same including making hole to suit the size of ex.fan and fixing the same in the wall with wooden blocks, screws ,hardware as required as per the site condition
Supply and installation of 3w EXIT / toilet double sided signage LIGHT 180 min back up polite auto glo ip 44 or eqvt with CABLE and 5a pin incl hanging arrangement cat no LED EM(S)
50MM Dia GI Pipe Wall bracket WITH Terrace lighting/Wall FLOOD Lighting WITH 50W led Crompton LIGHTLFLE-50-CDL- SECURITY AND OFFICE TERRACE FOR HVAC PANEL SERVICING
Supply, fixing ,testing and commissioning of AC chargeable emergency lamp with 2x4W led lamps with all connected accessories -PROLITE Self contained rechargeable emergency light 2x4watts with battery 12v 2.3 AH 120 MIN BACKUP -PEL LED LTBL With Cable and 5a pin
CABLE TRAYS Supply and erection of following size 2mm thick Ladder type, Pregalvanized, cable trays and cable tray of rolled GI Sheet, supports out sections, pipes, plates, etc. including welding, anchor bolts, threaded down rods(for 300 mm trays only), supply of necessary anchor bolts and grouting etc. including breaking walls, floors, etc. for structures as required including supply of all GI hardware materials, all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-charge.The rate shall include supply & fixing of MS Grip bolts in columns/beams/walls/ceiling etc.as required & including drilling also. Rod supports shall be of galvanized full threaded rods of sizes 8,10 & 12mm dia for fixing to anchor fastener, anchor bolts.The length of the full threaded rods for the purposes of quoting shall be 1200 mm & includes nuts & washers and supports shall be at a min.distance of 1Mtr.The rate will include all required bends, tees, vertical up & downs, radius bends and other applicable accessories shall be factory fabricated, complete & as required. The rate shall inclusive of necessary theaded rods,nuts & bolts, making clamp in the Z perlin/Truss, cable tray clamps etc,(8 mm threaded rod shall be provided at every alternative purlin appx. 2 mtr length)
300 x 50mm x2mm Ladder type cable trays
150 x 50mm x2mm Ladder type cable trays
Supply and fixing of Perforated Cable tray with horizontal & vertical bends, reducers, Tee's, cross over , suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr . incl cover for vertical areas The rate shall inclusive of necessary theaded rods,nuts & bolts, making clamp in the Z perlin/Truss, cable tray clamps etc,(8 mm threaded rod shall be provided at every alternative purlin appx. 2 mtr length)
450 mm width X 62.5 mm depth X 2.0 mm thickness
300 x 50mm x1.6mm
100 x 50mm x1.6mm
SUB HEAD -I :RACEWAYS & JUNCTION BOX RACEWAYS :Supply, installation & fixing of the following size of Raceways made out of 2,mm thick galvanized sheet steel with Rate shall be inclusive of all Civil works for concealing, floor finish, Curing, etc.
100x38X2mm GI Race ways floor trunking Including required under floor access outlet, under floor cross overs, under floor vertical access units, single compartment as specified incl joint sleeves
200x38X2mm GI Race ways floor trunking Including required under floor access outlet, under floor cross overs, under floor vertical access units, single compartment as specified incl joint sleeves
JUNCTION BOX :Supply, installation & fixing of the following size of junction boxes made out of 3 mm thick galvanized sheet steel junction boxes with top SS cover good finishing Rate shall be inclusive of all Civil works for concealing, floor finish, Curing, etc.
110 mm X 50 mm
210 mm X 50 mm
310 mm X 50 mm
SUB HEAD - J :UPS AND INVERTER Supply & testing of 3 KVA INVERTER 3Ph-in/3ph-out with 30Min backup with necessary mounting arrangement etc., Complete wiring required between the Inverter and it's battery banks & Battery Stands. The cost shall be inclusive of Structural steel supports etc.,
SUB HEAD - K :EARTHING EARTHING : Supply, Installation, testing and commissioning of earth plate of size 1200x1200x12mm CI Plate earth electrode at a depth 3000 mm in an earth pit filled with salt and charcoal mixed with sand in alternate layers of 150mm each up to a height of 3000mm from bottom. including supply and fixing of 38mm dia perforated GI pipe funneling for watering purpose including construction masonry. Heavy duty SFRC cover shall be used to cover the pit, Manhole cover size 450X450 mm as per IS 3043.
Supply, Installation, testing and commissioning of earth plate of size 600 x 600 x 3mm copper plate earth electrode at a depth 3000 mm in an earth pit of 450 x 450 x 350mm filled with salt and charcoal mixed with sand in alternate layers of 150mm each up to a height of 3000mm from bottom. Two copper flats of size 25 x 3 mm shall be braced to this copper plate throughout the overlapping length with the copper plate and brought to the surface of the earth pit. This plate shall have provision for connecting wires or flats as the case may be. A suitable size of 25/ 38mm dia GI pipe shall be provided up to bottom of the earth pit. This GI pipe shall have provision for watering through a funnel. A masonry structure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit.
Supply and laying of following copper flats laid in open / buried underground / concealed manner with necessary clamps, SMC insulators, screws, interlinks etc. for earthing .
50X10 mm GI . Flat for panel cable tray Body earthing
25X6mm GI . Flat for panel cable tray Body earthing
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required
10 SWG Cu. Wire for Gland earthing
8 SWG Cu. Wire for DBs earthing
25X6mm Cu Flat for earthing
SUB HEAD - L :STREET LIGHTING The rate includes excavation and foundation for erecting the referred street light pole as required at site and inclusive of necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. each arm with light- The pole shall be grouted inside ground pit (cross section 600 x 600 mm) with cement concrete 1:2:4 with necessary GI ‘A’ class pipes (not less than 38 mm dia, NB) to facilitate pulling of cables. Separate pipes shall be provided for incoming and outgoing cables. The cement concrete shall be protected from premature drying by curing for at least seven days after pouring. All concrete surfaces from 150 mm below ground level to top shall be finished smooth with cement mortar 1:4.-pole height above ground -7-m-top 70mm,bottom 130mm,thickness 3mm,with base plate size220x220x16mm-4nos foundation bolts,700 mm length 24mm dia.
Supply, erection, testing and commissioning of SOLAR street light fitting with 1x50W LED lamp, driver, fixed on 7m (above ground) swaged MS hexagonal poles confirming to IS1161, -Swaged and 1.5 m angle arm - Single arm conventional bracket for mounting fitting ,bracket assembly on to the pole top by means of angular rings , foundation base plate,ribs,4 fixing bolts (600mm anchoring bolt with 90 degree bend, including red oxide paint 24mm rod with 2nos PL Washers and 3nos nuts) anchoring bolt, cable entry pipe, poles treated for corrosion protection, earthing arrangement, excavation and back filling, finish to be of approved colour. Entire application shall confirm to IS2713 for Tubular Steel Poles for Overhead Power lines including numbering of poles. coil earthing etc. The pole shall be painted with one coat of primer and two coats of enamel paint, with 1Mtr long 25mm dia 'B' class G.I. Pipe as earth electrode with charcoal ,Salt with 10SWG copper wire interconnected with street light pole. cable entry G.I pipe of 2.5" dia. as per Drg and Technical Specification.- Philips ROAD FLAIR GEN 4.0 SOLAR equivalent approved make
Supply, erection, testing and commissioning of street light fitting with 1x50W LED lamp same as above item but with Double Arm
FLOOD LIGHT: Supply , Fixing, testing and commissioning of Integral flood light luminaire single piece pressure die cast aluminium housing, toughened glass cover with IP 65 protection with 1 x 45W led lamp for with driver and fixing the same on the outer column with necessary fixing hardwares as required as per the site condition. etc., (Crompton cat no LSFO 45 CDL OR equivalent)
Facade Lighting: Supply and erection of plinth / peripheral wall / Pole mounted 72W weather proof FLOOD LIGHT with necessary DRIVER etc.all complete for enlightens the elevation of the building. The scope includes construction of necessary plinth to the required height of Architect / Consultants and all other connected civil / other such work. The scope also includes providing necessary mounting brackets, lamp pilferage arrangement etc. to the satisfaction of the Architects / Building Managers.Assymmetical flood light fitting with IP: 65,
Supply and fixing of weather proof loop in loop out box made out MS sheet steel enclosure with 4Way 20A rated terminal block for the above landscaping , Terrace, post top light fittings with necessary fixing hardwares required as per the site condition.
SUB HEAD -- M -SAFETY EQUIPMENTS: Supply and laying of LT 2mm thick electrolytic grade rubber mat as per ISI IS 15652-2006 of size 2000x1000 mm in front of the LT panel boards.
FIRE EXTINGUISHER Supply, erecting and connecting a 6 KG ABC fire extinguisher powder type properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of fires (A, B & C).
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher with gun metal cap , nozzle,with initial fill properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of fires (A, B & C).to TAC norms
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer.
Supply, erecting and connecting laminated shock treatment chart both in English and local language directly fixed in the glazed frame on to the wall with necessary screws on all four corners.
Fire and emergency signage Boards( Fire escape directions, First aid charts, First aid box indications, safe material handling procedures, Fire assembly area indications etc,)
Supply of 1100 V Tested Gloves with Box
Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in local language and English
SUB HEAD -- N -MISC ITEMS:
Supply, Fabrication, Erection of structural steel including 2 coats of red oxide primer & 2 coats of approved enamel paint .Items including all channels and angles, suspension supports, steel plate, anchor bolts, cross angles, brackets, etc. including grouting, welding, tools, tackles as required etc. The payment shall be made for the actual quantities measured. This item shall be operated for tray supports in cable trenches, cable trays, Mounting frames for panels and DBs., vertical tray supports et,panel, busduct supports
WALL/POLE mounted cable junction boxes
Supply and laying of 25mm dia 2mm thick MS Conduit with all connected accessories.
Supply and laying of 32mm dia 2mm thick MS Conduit with all connected accessories.
Supply and laying of 40mm dia 2mm thick MS Conduit with all connected accessories.
Supply and laying of 50mm dia 2mm thick MS Conduit with all connected accessories.
Supply and laying of 20mm dia Heavy duty PVC Conduit with all connected accessories.
Supply and laying of 25mm dia Heavy duty PVC Conduit with all connected accessories.
Supply and laying of 32mm dia Heavy duty PVC Conduit with all connected accessories.
Supply and laying of 50mm dia Heavy duty PVC Conduit with all connected accessories.
Supply and laying of 25mm dia 2mm thick GI Conduit with all connected accessories. FOR flame proof lighting class A
Supply & Erection of Cable Tags as per the Cable Schedule.
SUB HEAD -- O -LIASIONING Liaison with the Chief Electrical Inspector to Govt., /CEA for preparation of Working drawings etc., obtaining approval for drawing.Preparation of completion Report, Arranging for Inspection and attending to defects report and preparation of as fitted drawings and obtaining Safety Certificate from CEIG /CEA for commissioning. Liaison with the Chief Electrical Inspector to Govt., for issue of Safety certificate approval for energisation. clearance from DEPARTMENTS.The works executed as built drawings need to be submitted in the blue print of A1 size in 4 Sets of hard copy and two set sets of soft copy in CD.The necessary statutory fees/charges will be paid by the client against demand advice.
SUB HEAD -- P - NETWORKING, MOLEX MAKE Supply and laying of Cat 6A 4Pair UTP Cable (Box of 305 Mtr) with all connected accessories for DATA-blue ( Molex )
Supply and Fixing of Cat 6A 48Port Unloaded Jack Panel for data
Supply and Fixing of Cat 6A UTP Jack for Data -Blue Color for Rack Side
Supply and Fixing of Cat 6A UTP Jack for Data -Blue Color for Workstation Side
2Port Wall Plate Square Type Face Plates WITH BACK BOX
1Port Wall Plate Square Type Face Plates with back box
Cat 6A stranded Patch cord 1 Meter - Blue for Rack side
Cat 6A stranded Patch cord 2 Meter - Blue for WS side
Supply and laying of 25mm dia Heavy duty PVC Conduit with all connected accessories.
Cat 6A 4Pair Shielded net work Cable for connectivity BLUE
VOICE CONNECTIVITY Supply and laying of Cat 6A 4Pair UTP Cable (Box of 305 Mtr) with all connected accessories for VOICC
Supply and Fixing of Cat 6A UTP Jack for Voice -Yellow Color at Rack Side
Supply and Fixing of Cat 6A 48Port Unloaded Jack Panel for Voice
Cat5e UTP 48-port Non-Shutter Patch Panel, loaded ,resources (EBPAX) Side
Supply and Fixing of Cat 6A UTP Jack for Voice -Yellow Color at User End
Supply and Fixing of Cat 6A , stranded Patch cord 1 Meter - Blue for Rack side
Supply and Fixing of Cat 6A , stranded Patch cord 2 Meter - Blue for User End
Cat.3 50pr UTP Cable 305m/reel Grey_CMR
Hookup Wire-100 mtr
FIBER BACK BONE CABLING Supply and laying of 12 core OFC fiber Single mode
10 Pair DB
Cat5e UTP 50 Port Telephone Patch Panel
Supply and Fixing of Supply and fixing 50 port voice panel IP with all connected accessories-
Supply and laying of High speed low loss shielded Data communication cable to form the backbone data communication network cable in a 20mm dia Heavy duty PVC Pipe running in the existing Built in trench / Cable tray/inside the panel etc. with necessary fixing accessories as required as per the site condition.
Digital TV outlet and with moulded front plate GI anodised enclosure in the wall and other associated accessories including chasing embedding rough plastering as required as per the site conditions for TV- MK-K3552DABWHI-POINT
Supply and laying RG 11 Coaxial tinned copper conductors with suitable Medium FRLS 20mm dia PVC conduit pipes along with necessary accessories for T.V cables
Voice 3 u 150 pair with TTB frame and 40 pair krone module
4 port quadrilateral face plate
10 pair raiser cable armoured
42U Rack Frame/800X1000/Steel/NRS/ CKD Assembled/Casters Type 3/Black,Levellers,19" Adopter Kit/42U/Closed/Door/100X150/2/Black,Glass Door/800/42U/NRS/Black,Metal Door/800/42U/NRS/Black,Side Panels/1000/42U/Vented/NRS/Black,Server /IT Rack mount power distribution unit, 1Ph, 230V, 32A, 50/60Hz, Zero U standard with 12 X Indian Round Pin 5/15A, 16A MCB X 2 Circuits- PDU Rating 7.3KVA/Bottom feed-3Mt/ Black/ Inlet Plug Not Installed,Horz. Cable Organiser/1U/ Channel On Front,Shelf/1000/Black,Shelf/Key Board/19"Rty/1000/Black,Mounting Hardware-CR (Pack of 20),ITE / Server Rack Air Circulation module/Tower Mount/360CFM.
HDMI Cable 5 M Full HD
VGA MALE TO MALE CABLE 5 M
Audio Video Network POPUP box DESKTOP HYDRAULIC
HDMI 2 X 8 Switcher Cum Splitter With Remote - 2 Input 8 Output - 3D Full HD
Temperature monitor equipment for server room and UPS room
Timer for server room and UPS room
Note : The system should be with built -in-SIP server ready to connect any third party SIP phones
Supply, Installation, testing and commissioning of 48 port POE switch as per specification for IP phones, Fiber patch cord along with trans-receiver including all accessories
Supply, installation, testing and commissioning of Riser cable consisting of multiple /50 core or solid copper conductors of 24 AWG size insulated with expanded polyethylene covered by a PVC skin and inner shielding for grounding. The core shall be covered by a layer of plastic tape and overlaid with a corrugated PVC plastic. The cable shall be as per the specifications laid down in the tender including termination and all required accessories
LIGHTNING PROTECTION & EARTHING SYSTEMS AIR TERMINAL Supply of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) , OBO Type No. RD 8/ALU I (5450 08 6)
Supply of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance OBO Type No. 177 30 M8(5207 46 0 )
Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. OBO Type No. 165 MBG 8-10 ( 5218 70 0)
Providing of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts . OBO Type No.251 8-10 ( 5312 03 5 )
Providing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. OBO Type No. 172 AR ( 5218 92 6 ) Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ). OBO Type No. 249 8-10 ST ( 5311 50 0 )
Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod : Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IS/IEC 62305) 4Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. OBO Type No. 101 VL 4000 ( 5401 99 5 ).
Accessories : System consist of Fang Fix with base and clamp, on the top air terminal is erected. OBO Type No. F-FIX 16 ( 5403 20 0 ).
Down Conductor Supply of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) , OBO Type No. RD 8/ALU I (5450 08 6)
Supply of conductor holder for sidewall- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance OBO Type No. 177 30 M8(5207 46 0 )
Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer OBO Type No. 271 8-10 ( 5317 40 1 )
Enclosure for Test joint: RoHS Complied, IP66, 6mm², 500V, IK08, UV resistant, Halogen free Thermoplastic junction box ,installation of cables either directly through the 7 x M25 seals, polypropylene,Light grey. Overall Dimensions: 114mm X 114mm X57mm, Internal Dimensions: 100mm X 100mm X 48mm OBO TYPE : T 60 (2007 061)
Lightning counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. OBO Type No. LSC I+II ( 5091 72 2 )
Earthing Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx:70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding. OBO Type No. 5052 DIN 30X3 ( 5019 34 4 )
Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. OBO Type No. 255 FL30 FT (5314 53 4 )
Providing of flat conductor holder suitable for FL 30. Installed with 2 hexagonal bolts.OBO Type No. 166 LS 70 (5226570)
Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. OBO Type No.356 50 ( 2360 05 5 )
Supply & installation of CPRI tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 14.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 ( OBO Type No. 14 3000 CCER)& is provided with universal clamp made of SS to connect rod with flat conductor ( OBO Type No. 14 25 RTC) . Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested(OBO Type No.OEC 2 25) . The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system (OBO Type No.UFE) .
FIRE ALARM & PA SYSTEM Supplying & installing of Addressable analogue photo electric type UL listed multi sensor smoke detectors with dualcheminiser solid state design, indicating lamp, mounting base and inbuilt fault isolation facility etc.,(above & below false ceiling / true ceiling)
Supplying & installing of Addressable analogue type Heat Detectors with solid state design with sensing elemant combination of fixed type and rate of rise temperature indicating LED mounting base etc. as per detailed specification.
Supply & Installation of UL listed response indicator with all required accessories.
Supply & Installation of UL listed Control trip module with all required accessories for VRF units.
Supply & Installation of Fault Isolation module . Vendor to quote for this Item if smoke detector does not have inbuilt fault isolation facility.
Supply and Installation of addressable analogue dual type UL listed electronic hooter cum Strobe.
Supply and Installation of addressable analogue type UL listed type manual call points/push button stations with hammer,chain & all required accessories.
Supplying, installing, testing and commissioning of 24W wall mounted type speakers
Supplying, installing, testing and commissioning of 6W ceiling speakers
Supply & Installation of 2 core of 1.5 Sq.mm armoured cable. (red colour)
Supplying, installing, testing and commissioning of approved make flexible multi core 1.5 sq.mm control cable
Supplying and laying of 25mm dia PVC conduit with necessary fitting like elbow, collars etc
Supply, Erection, Testing & Commissioning of Micro processorcontrolled 'Main Fire Alarm Control Panel' UL Listed, with dual stage alarm facilities like hooter, fire/fault indicators, audio-visual signals battery,battery charger, central processing units, video display and with Intigrated Digital Voice Evacuation and 2 way Communication Fire Fighters System capable to supervise of all the speaker circuits, with required number of zone control as given below and accessories required to complete the system. The equipment shall be of same make as panel. DVC shall offer minimum one fire man's telephone circuit & one speaker's circuit. DVC shall be with in-built digital microphone & fire man's telephone hand set.
2 -Loop panel
Digital Voice Evacuation & 2 way communication fire fighter system 2 Zone Console
FIRE EXTINGUISHERS (INTERNAL ) Supplying, installing and commissioning first aid fire fighting appliances with signages.
ABC Multipurpose - Capacity : 6Kg.
CO2 - Capacity : 2Kg.
CO2 - Capacity : 4.5Kg.
DCP - capacity : 6kg
Mechanical Foam- 9ltr
SIGNAGES Providing and fixing in position the signages " FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of 3' x 4'. 1)ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATION. 2)EVACUATE THE OCCUPANTS BY USING THE FIRE EXITS & EMERGENCY EXITS ONLY. ASSEMBLE AT VARIOUS ASSEMBLY POINTS 3)IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING THE NEAREST/SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER 4)BE CALM, DO NOT GIVE ANY ROOM FOR PANIC, WALK, DO NOT RUN 5)IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, STAY IN YOUR PLAN AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM
Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, complete with mirror fasteners. - RO 1)ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM. 2)INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: 3)IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER…….. 4)FIRE FIGHTING AGNECY ------------------------------- 5)PHONE : ----------------------- 6)FAX : ----------------------------
Fire and emergency signage Boards( Fire escape directions, First aid charts, First aid box indications, safe material handling procedures, Fire assembly area indications etc,) The signages should be battery backup with self illumination
Providing and installing of Fire Evacuation Plan with route in rectangular Acrylic sheet with ss bolt of size 600 x 450mm & 2 to 3mm thick
HVAC Supply, installation, commissioning and testingof High Precision package type DX air cooled unitwith top/ side discharge, air cooled condenser with fan and motor, with filter section, EC motor with plug type axial fan, air cooled condenser coil with anti corrosive paint, twin scroll compressor motor set with R 407 C refrigerant, condensate drain pan, in built data logger, power monitor relay, liquid receiver, thermostatic expansion valve, vibration absorber for compressor, HP/ LP cutouts, Water detector sensor, fire tripping relay, in built auto sequencing program, micro processor panel, digital display, programmable control and recording unit, alpha numeric display, function keys, cursor keys, free programmable keys, multi color LEDs, Humidifier, Heater, battery back up supply at 24 V/ 50 cycles/sec etc. The unit shall be suitable for operation on 415 V, 3 phase supply. The display panel shall display date, time, actual & set values, fault timing values,. Controls shall be suitable for linking to Building Automation System Modbus open protocol.
Capacity 70 KW (20 TR) temperaure 20 +/- 0.8 deg C, Relaitve humidity 50% +/- 5% RH.
Capacity 45 KW (14 TR) temperaure 20 +/- 0.8 deg C, Relaitve humidity 50% +/- 5% RH.
Masonry pedastals for air cooled condenser unit
Supply and laying of 18/19G copper refrigeration piping with all fittings should be long bend (no elbow) with proper insulations, supports, nylon tape wrapping etc
34.9 mm copper pipe
28.58 mm copper pipe
22.2 mm copper pipe
15.6 mm copper pipe
Supply and laying of ALUMINIUM SHEET ducting, complete with anchor fasteners and GI supports, bracings as required, nut, bolt & gasket etc
22 G ducting:
20 G ducting:
Supply and installation of powder coated Aluminium Supply air grills and return air outlets:
Supply air grille with damper
Return air grille w/o damper - continuous type
Supply and installation of powder coated Aluminium fresh air damper and cowl:
Supply and installation of fusible link type fire damper: Frames 18 G Aluminium Louvres 20 G Aluminium
Supply and laying of thermal insulation of duct with anti microbial insulation of 19 mm thick, density not less than 20 Kg/cum, class 0 fire rating as per BS, low thermal conductivity and excedllent water vapor diffusion prevention and laminated with 26 G Aluminium foil:
SITC of standalone type hiwall units complete with indoor unit, outdoor unit, angle bracket for ODU support, interconnecting copper refrigerant piping (approx. of 10 M) with nitrile rubber insulation, PVC drain piping (approx. 10 M length), cordless remote controller, 220V stabilizer to be wall mounted, electrical wiring and all other necessary accessories.
Conference Room 2 TR - R410A refrigerant -(5 star rating)
Server Room 2 TR - R410A refrigerant -(5 star rating)
Sample Room 2 TR - R410A refrigerant -(5 star rating)
Office - - R410A refrigerant -(5 star rating)
AC outdoor Unit stand
Refrigeration piping (suction + liquid) each
Inter connecting wiring of copper
Installation
Supply and laying of fresh water and drain piping for the units, with PVC piping of 4 Kg rating, complete with bends, fittings and supports
25 NB (Drain)
Supplying and fixing of acoustic lining of wll and ceiling of AHU rooms with 50mm thick density 14 kg/Cum armasound board with aluminium foil lamination friction fixed in 610mmx610mm frame work made of 50mmx50mm made out of 0.60mm thick GI sheet U shaped channel and covered with reinforced fibre glass tissueand finished with 0.80mm perforated aluminium sheet etc. Complete as per the specification
CCTV Passive and Active Components- Security Monitoring Supply and Installation of following items with necessary connections/terminations
5MP IR Dome IP CAMERA 2.8mm WDR H.265 POE--HC30W45R3
5MP bullet IP camera HC30WB5R2 OR EQVT WITH INTRUSION DETECTION MONITORS
NVR, 16-Channel, H.265, 4K 12 MP, 4 SATA, 16 PoE, No HDD-HEN16204
Hard disk - AV 2TB
Cisco SG350 - 8 Port poe with SFP Slots with SFP Module
CAT6 UTP 4P CABLE-305M BOX
6 core Armoured Cable Single mode laid in suitable Flexible HDPE corrugated sleeving pipe INCL erecting in underground at 750mm depth
6 Port DIN Rail Mount LIU Loaded
LC/PC 1.5M LSZH OS2 Patch Cord
Outdoor enclosure IP66 with Internal wiring , Surge Protector , Terminal Blocks & MCB
Samsung DB32E 32 Inch Slim & light signage Professional display with , HDMI Interfaces
Supply, erection, of 6m (above ground) hot dip galvanised poles for fixing camera confirming to IS1161, - bracket for mounting camera ,bracket assembly on to the pole top by means of angular rings , foundation base plate,ribs,4 fixing bolts (600mm anchoring bolt with 90 degree bend, including red oxide paint 24mm rod with 2nos PL Washers and 3nos nuts) anchoring bolt,cable entry pipe, poles treated for corrosion protection, earthing arrangement, excavation and back filling, supplying and laying cables through Hensel make weather proof junction box as required. finish to be of approved colour.Entire application shall confirm to IS2713 for Tubular Steel Poles including numbering of poles. The pole shall be painted with one coat of primer and two coats of enamel paint,with 1Mtr long 25mm dia 'B' class G.I. Pipe as earth electrode with charcoal ,Salt with 10SWG copper wire interconnected with pole
Mounting arrangement for Fixed cameras
3 Core 6 Sq.mm PVC Copper armoured Cable in suitable flexible HDPE corrugated sleeving pipe erected u g at depth of 750mm INCL TERMINATION,mcb isolators,with required accessories
6 u rack with accessories for NVR
RCC REINFORCED V TRUFF erected over undergound cable
Supply, Erection and Commissioning of S Phase input, S phase output UPS 1 KVA APC MAKE, online with 30 Minutes Battery backup (Maintenance free dry type batteries) with full protective devices in-built. & battery rack also. on line double conversion with BCB 12V 26 AH- SMF Battery with 30 min backup-3 nos-Exide-rack plus interlink cables +dc cables+AC Cables switches
Fiber Splicing, Testing Documentation
testing and commissioning, documentation, software installation,
P Subramani and Co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .