Tender Value
₹16.2 L
EMD Value
₹32,400
Closing Date
1 Jun 2020, 6:00 pmClosed
CWE (ARMY) SECUNDERABAD
CWE (ARMY) MUDFORT COMPLEX, SECUNDERABAD- 500003
PROVISION OF 20 KW SOLAR ENERGY POWER PLANT AT HQ TASA AND PROVISION OF ROOF TOP SOLAR PV GENERATION WITHOUT BATTARY AT AOC CENTRE UNDER GE(U) SECUNDERABAD
2020_MES_313442_2
CWE(S)/UTILITY/TOKEN-21 OF 2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Secunderabad
As per NIT
6 documents required · 6 mandatory
₹500
GE(Utility)Secunderabad
₹32,400
Yes
16 Jul 2020
27 Apr 2020
4 Jun 2020
27 Apr 2020
1 Jun 2020
8 May 2020
Amount
Design, procure, erect install, test and commission including connecting to local utility grid; Grid connected solar photovoitaic plant of 20 KW capacity (roof top) including solar photovoitaic Module, DC cabling, Module Mounting Structures, Combining Boxes, Lightning Protection of SPV modules and other accessories, string inverter, consisting of following main componenets: - Poly Crystaline Silicon Solar Photovolaic minimum of 315Wp, not less than 20KW capacity, having efficiency 16.28% min under standard conditions, form fill factor more than 0.74, plant performance ratio > 75% , made of high transmitivity glass front surface and it shall give high encapsulation gain ( transmittance above 90% and bending less than 0.3%). The electrical parameters of SPV modules under standard test condition of irradiance 1000 W/sqm2, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under Max Peak Power Pmax > 315W Voltage at Max Power :>38.81V Current at Pmax: >8.12 A Short Circuit Current : > 8.84 A Open Circuit Voltage: >45.94 Module Efficiency: > 16.28% .
(a) Rated outputof the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed. (b) It shall perform satisfactority in RH 85% with temperature up to +85 degree C and should withstand wind of 150 kmph on the surface of panel. (c) PV modules shall be warrented for their output peak watt capacity, and it shall not fall of its initial value below 90% in first 10 year end and 80% after the end of 25 years. (d) Each module shall have RFID tag encapsulated with solar cell bearing following details: Name of manufacture of SPV Module, Name of Manufacturer of solar cell and module) country of Origin ( both cell and module) Peak wattage, Im, Vm and fill factor of the module IV curve of module. (e) The temperature coefficient of the module shall not be more than 0.50% degree celcius.
(f) PV modules must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID. (g) It shall also be in confirmity to latest minimum technical specification issued by MNRE from time to time. Modules should be of 72 cell configuration and should be of MNRE approved companies/agencies in category/ rating 'SA-1A' . (h) Provision of earting and earth strip/ cable etc for earth of solar Pvmodule/ array etc as per latest IS/MNRE norms to be provided and cost of the same is deemed to be included in the item and no extra amount will be paid to the contractor on this account. (i) Both cell and SPV modules shall be made in India and must conform to DSR norms of MNRE (j) The minimum net annual generation shall be 1450 units per kilowatt. Make: Vikram solar, Waaree, TATA, ADANI, RENEWSYS
DC Cables & AC Cables: Suitable size of XLPE insulated tinned copper cable of solar grade, 1100 volt and UV resistant for putdoor installations confirming to IEC 60227/15694 & 60502/ is 1554 (Pt& I&II) of minium size 6sq.mm All cables and connectors for use of installation shall be of solar grade which can withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt,burial and attack by moss and microbes for 25 years ans voltage as per latest IEC/IS. All the cables/wires shall be provided with UV resistant printed ferrules for DC side .The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. The AC cables along with AC DB with necessary arrangement to Connect with the existing power supply to be done. The size of XLPE LT cable To be got approved by Engineer in charge. Suitable electronic smart meter To be fixed to measure generation of electricity. Cable batch no,drum no, IS code and size and make shall be metioned on every one meter or as per OEM practice .The wiring of the module interconnection shall be in suitable size UPVC/HDPE pipe. The cost of interconnecting DC copper cable, and earth work for trenches suitable to accommodate solar grade cables from SPV module upto inverters are included in the item. Make: Lapp, Havells, Polycab, Leoni, Siechem
Module Mounting Structure: Design, procure, fixing, support structure made of hot dipped galvanisized iron with min 85 micron thickness including necessary PCC foundation and associated work and fixing mounting arrangement suitable for SPV modules so as it can withstand wind speed of 150km per hour. The array mounted structure has to be so designed that it occupies minimum space without sacrificing the output of SPV panels, Nuts, bolts,mounting structure including module mounting structure shall have to be adequately protected from atmosphere and weather prevailing in the area. All the modules fixing fastners shall be of stainless steel of grade SS316.The module mounting structure to be fixed tilt to optimise the maximum generation in a year. MMS design shall be supported with stadpro report and submitted for the approval of the acepting officer. Cost of all equipments, copper strip up to earth test point and earthing etc are included in this item. The cost of sufficient earthing for lightning protection is included in this included in this item and no extra payment will be made to the contractor on this account.
String Inverter: Procure, fixing, testing and commissioning of 20KW -1 No 50+3 Hz (min) 3 phase 460 volt, THD< 3%, at nominal power inverter suitable to convert DC power of solar PV module/arry/ to AC for further feeding to grid confirming to IEC 61683 for efficiency, IEC 62109 or equivalent for safety and IEC 62093 for reliability. The input DC technical specification of 10 KW inverter are as under: Input (DC) DC V oltage Range: 575-850 V Max DC Voltage:1000 V Max DC Current : 82.0 A Output AC Nominal Power : 20 kW Max output power : 20 kW Nominal AC current : as per standards Nominal oUTPUT vOLTAGE: 460V Output Frequency : 50/60 Hz Harmonic Distortion current : < 3% Efficiency : 98.3% Standby operation consumption (feed in) : < 20 W
Operating temperature up to 85 degree centigrade . The inverter shall have minimum IP 65 protection, ground fault monitoring, grid monitoring , protection against anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and temperature . The inverter shall adjust voltage and frequency levels to suit the grid . The inverter shall be selfcommulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. Maximum Power Point Tracker(MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximum the energy drawn from the PV array. The inverter shall be suitable nos of protected inputs (as per design) and outgoing shall be protected by Surge protections (MOVs) .The inverter shall be provided with protection class I (IEC 62103) .The inverter should have MODBUS, PROFIBUS, ETHERNET comn ports .The inverter shall include appropriate self protection and self diagnostic feature to protect itself and the PV array from the damage in the event of the inverter componant failure or from parameters beyond the inverters safe operating due to internal and/or external causes. Inverter shall have protection arrangement against ground leakage faults, over voltage, ( SPD) & over current. Inverter should interfaces with Ethernet, RS485, irradation and temperature sensor, Auxilary equipment and power supply, external stop signal. Should have residual monitoring system. The inverter should have provisions of Galvanic isolation, antiislanding. Inverter must have the feature to work in tandem with other similar inverter and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. Make: ABB , SMA, Refusol, Fronius, Power One,Kaco,Delta
Note : 1. The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables lightning arressters etc complete. 2. The contractor shall submit complete scheme including electrical diagram of the work , schematic diagram, SPV module layout, Civil work viz etc complete as per SECI latest guidelines as applicable IEC and IS to the GE for approval with in one month of date of commencement of the work.
Design, procure, erect, install, test and commission including connecting to local grid i.e online solar photo voltaic roof top plant of capacity 2 KW including solar PV modules, DC cabling, Module mounting structure all as per latest SECI-MNRE guidliness and directions consisting of following main components:- (a) Mono crystaline silicon solar photo valtaic modules 250 WP x 8 Nos, connected seriously to get output not less than 2 KW capacity having efficiency as 16% minimum under standard conditions, plant performance ratio greater than 75% , made of high transmitivity glass front surface and it shall give high encapsulation gain (transmits above 90% and bending less than 0.3%). The parameters of modules under standard test conditions of irradiance 1000W/Sqmm, AM 1.5 spectrucm and temperature 25 degree Celsius shall be as under. (i) Maximum power - 250 W. (ii) Voltage at maximum power 31.5 vots. (iii) Current at maximum power 7.94 Amps. (iv) Open Circuit voltage - 3.8 volts. (v) Short circuit current - 8.75 Amps. (vi) Tolerance + 3%. (vii) Module efficiency - 16%. (b) It shall perform satisfactory on RH 85% with temperature upto 85 degree C and should withstand wind of 150 KMPH on the surface of the panel.
(c) PV module shall be warranted for the output peak watts capacity and it shall not fall of its initial value below 90% in first 10 years end and 80% after the end of 25 years. (d) Each module shall have RF ID tag encapsulated with solar cell bearing details of - Name of manufacturer of PV module, solar cell, month & year of manufacturing, country of origin, peak wattage, Imax, Vmax and fill factor of module including the test certificate issued by IEC indicating unique serial number and model. (e) PV module must confirm to latest edition of IEC 61215 - IS 14286. In edition the module must confirm to IEC 61730 part -I & II for construction and testing and safety qualifications and confirming to IEC 62804 PID. (f) Suitable size of DC cables PVC insulated tinned copper cable of 1100 volts grade and UV resistant confirming to IEC 60227 - 15694 and 60502 - IS 1554 (Part -I & II). (g) Provn of earthing and earth strip/cable etc, earth of solar PV module/Array etc as per latest IS - MNRE norms to be provided and cost of the same is deemed to be included in the item and no extra amount will be paid to contractor on this account to the contractor.
Supply and fix, test and connect sine wave solar inverter of suitable capacity to meet 2KW, 50 Hz, 3 Ph to convert DC power solar PV modules to AC for further feeding to grid.
Design, procure and fixing support structures made of hard dipped galvanized with minimum 85 micron thickness including necessary PCC foundation and associated work (if required) and fixing mounting arrangement suitable for SPV modules so as it can withstand wind speed of 150 KMPH. The array structures as to be so designed that it occupies minimum space. The mounting structure shall have to be adequately protected from the atmosphere and weather prevailing in the area. All the fastners shall be of stainless steel of grade SS316. The module mounitng structures to be of manual seasonal till of 0 to 40 degree to provide maximum generation.
omsai thermax engineers
sandhya enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .