Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.9 LAccepted-AOC J 7 SAKET SAKET SOUTH DELHI DELHI 110017 | SOUTH DELHI | DELHI | 110017 | L1 | Accepted-AOC L1 | |
| 2 | L2₹73.2 L+₹6.4 L (9.50%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹75.9 L+₹9.0 L (13.5%)Rejected-AOC 47 C MODEL TOWN EXTENSION LUDHIANA PB | LUDHIANA | PUNJAB | 141001 | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹1.0 L
Closing Date
16 Sept 2024, 12:00 pmClosed
Executive Engineer Drainage Division Sangrur
Executive Engineer Drainage Cium Mining Division Sangrur
ESTIMATE FOR CONSTRUCTION OF VR BRIDGE AT RD 82000 OF LEHRAGAGA MAIN DRAIN
2024_WR_115931_1
39/2023-24
Open Tender
Civil Works
Item Rate
45 days
Sangrur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
₹1.0 L
27 Nov 2024
16 Jan 2024
16 Sept 2024
16 Jan 2024
16 Sept 2024
16 Jan 2024
Amount
Earth work in excavation of foundation of structure as pper drawings and techhnical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil by mechanical means for depth upto 3m
Earth work in excavation of foundation of structure as pper drawings and techhnical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil by mechanical means for depth 3m to 6m
Providing cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregates 40mm nominal size mechanically mixed, placed in foundation ncluding supply, carriage, loading and unloading of material from an approved quarry complete as per drawing and technical specifications and compacted by vibration including curing for 14 days
Providing and Laying plain cement concrete M-15 in open foundation including supply, carriage, loading and unloading of material from an approved quarry complete as per drawing and technical specifications
Providing and laying RCC M-30 in open foundation with batching plant, transit mixer and concrete pump including supply, carriage, loading and unloading of material from an approved quarry complete as per drawing and technical specifications
Providing and laying RCC M-25 in open foundation with batching plant, transit mixer and concrete pump including supply, carriage, loading and unloading of material from an approved quarry complete as per drawing and technical specifications
Providing and laying Reinforced cement concrete M-30 in sub structure height up to 5 m using batching plant, transit mixer and concrete pump including supply, carriage, loading and unloading of material from an approved quarry complete as per drawing and technical specifications.
Furnishing and placing RCC Grade M-30 using batching plant, transit mixer and concrete pump for solid slab super structure including centering and shuttering height upto 5 m including supply, carriage, loading and unloading of material from an approved querry complete as per drawing and technical specification.
Furnishing and placing RCC Grade M-40 using batching plant, transit mixer and concrete pump for solid slab super structure including centering and shuttering height upto 5 m including supply, carriage, loading and unloading of material from an approved querry complete as per drawing and technical specification.
Providing and laying reinforced cement concrete M-25 in sub structure height upto 5 m using batching plant, transit mixer and concrete pump including supply, carriage, loading and unloading off material from an approved quarry complete as per drawing and technical specification
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Providing and laying jointing, fixing, testing ISI marked G.I Pipe (as per IS 1239) B class including cost of specials such as tees, bends, sockets, elbows etc, cutting, threading and testing in trenches in the ground complete (100 mm i/d)
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with grating 150x150mm, cover and frame clear opening 300x300 mm and outer size 330x330 mm and chamber including cost of all brick work etc complete in all respect
Providing and filling expansion joint with sealing compound as per drawings and technical specifications with coarse sand and 6m percent bitumen by weight
Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement 2mm covered with sealant complete as per drawing and specifications
Filling stone or spalls into crates and hand picking including supply of boulder stone and carriage approved from quarry, loading and unloading in all respect
Compaction of earthwork in 20 cm layers, dressing, watering, rolling of earth as per PWD specifications in all respect.
Removal/ Clerance of slush from we drain by mechnical means
Disposal/Carriage of slush using hydraulic excavator and tippers i/c cutting and loading in tippers and transporting to the embankment location with all lifts and leads of 2 km.
Providing weep holes in Reinforced cement concrete abutment, return wall with 100 mm dia PVC pipe through the full width of the structure with slope of 1V:20H towards drawing face complete as per drawing and technical specifications
Drainage spouts complete as per drawing no SD/205 and technical specification with 0.5 meter long GI 100 mm dia drainage GI light grade pipe (for Bridges)
Weaving of MSA wire crates netting 15cm x 15cm mesh i/c binding sides and partitions including supply of MSA wire 4mm dia as per PWD specifications.
Providing and laying of filter media with granular material/stone crushed aggregates satisfying the requirement laid down in clause 2504.2.2 of MORTH specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment to the full height compacted to a firm conditions including supply and carriage of materials from approved quarry complete as per drawing and technical specifications as per specifications.
Hazard marker sign board 300*900 mm rectangular as per IRC 67-2012 with high intensity micro prismatic grade retro reflective sheeting as per ASTM D 4965 09 and IRC 67 2012, fixed over 4mm thick aluminum composite material (ACM) sheeting having skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200mm c/c to back support frame of 25*25*3mm angle iron supported on a square hollow steel section post 60*60*3.2mm conforminh to IS 4923 firmly fixed to ground including foundation, concrete M-25 of size 0.45*0.45*0.60m for verticle post complete as per clause 801 of MORTH specifications
Cautionary sign board 900x900x900mm triangular Using high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.42to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 .
Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as per IS code IS 458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc
Excavation in soil (any type) using hydraulic excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity incluidng cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections including all lifts and combined lead upto 30m in all respect
Rehandling of earthwork using hydraulic excavator and hydraulic tractor trolly complete in all respect with lead 0- 450 m
Dismantling of brick work in cement sand mortar / lime mortar including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. & staking the serviceable material with all lifts & lead of 100 metre (By Mechanical Means)
Removing Hume pipes from existing bridge
G C CONSTRUCTION
MANMOHAN SINGH CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .