| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.0 LAccepted-AOC | 1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | 2₹26.2 L+₹22,738.11 (0.87%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹28.5 L+₹2.5 L (9.74%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹29.0 L+₹3.0 L (11.5%)Rejected-Finance 24 A RAGHBIR MARG NEAR 22 NO PHATAK PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹30.1 L+₹4.2 L (16.0%)Rejected-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | 5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
5 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
REPAIR REPLACEMENT OF UNSV SUBMAIN DB METER BOX BUS BAR CHAMBER AND ALLIED E M SERVICES AT OLD CANTT UNDER AGE E M GE N PATIALA
2021_MES_494121_1
GE(N)/PAT-60/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
PATIALA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹98,000
Yes
2 Feb 2022
11 Dec 2021
7 Jan 2022
11 Dec 2021
5 Jan 2022
22 Dec 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and directed.
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for providing river sand as in sand cushioning to under ground cable including punning down of sand in layers complete all as specified and as directed
supply and laying un-reinforced precast concrete cable cover class LV, Type 2, with peak size 300mmx180mmx40mm. complete all as specified and directed.
M&L for making bore below the road(any type)/pcc/ for crossing the GI pipe light grade 40 mm dia for cable protection and fill the putty on both sides of the GI pipe after crossing the armoured cable to avoid the water inside complete all as specified and directed.
M&L for galvanized steel tubing 40 mm light garde (ISI marked) inreplacement of old damaged steel GI pipe for protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed. Make : Tata/Jindal/Surya
M&L for FIXING/PASSING/LAYING of XLPE cable on/in wall or through hard standing. cutting of suitable size slot on walls or laid in pcc or cemented floors, with all necessary fittings.and making good the disturbed surface with cementing work complete all as specified and directed. NOTE:- 1.cost of demolition of pcc/hard standing, removal of extra concrete scrape and re-conditioning the surface with same material included in quoted rate 2.Length of GI pipe(if used) measured and paid seperately.
Supply , laying , jointing and testing in replacement of u/s XLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sq mm 4 Core with aluminum thimble of same size complete all as specified and directed.
Supply , laying , jointing and testing in replacement of u/sXLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sq mm 4 Core with aluminum thimble of same size complete all as specified and directed.
Supply and fixing in replacement of u/s metal plug and socket single pole and neutral with a two pin and earth plug and socket alongwith one single pole MCB of 20 Amp concealed in wall complete all as specified and directed.
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 4 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 2 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as specified and directed. Note1: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost. Note2 : Two runs of 4 sqmm cable alongwith one run of 2 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 4 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as specified and directed. Note: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost. Note2 : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 10 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 6 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as specified and directed. Note1: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost. Note2 : Two runs of 10 sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
Supply and fixing for sub main wiring Four single core PVC insulated and unsheathed cable with 10 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 6 Sqmm 2 core PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as specified and directed. Note1: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost. Note2 : four runs of 10 sqmm cable alongwith two run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
S/Fixin replacement of old MCB DB SPN 12 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed.
S/Fix in replacement of old MCB DB SPN 8 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed.
S/Fix in replacement of old MCB DB TPN 4 Way factory made IP 43 protection class metal double door with Shrouded Neutral Bar & Pan assembly with connecting link complete including Provision for fixing one MCCB upto 125A complete all as specified and directed. (MCCB will be measured and paid separately under respective items of sch A):-
S/Fix in replacement of old MCCB DB TPN 4 Way vertical type factory made IP 43 protection class metal double door with Shrouded Neutral Bar & Pan assembly with connecting link complete including Provision for fixing one MCCB upto 125A complete all as specified and directed. (MCCB will be measured and paid separately under respective items of sch A):-
S&F in replacement of old MCCB Fixed type 100 Amp 3P 16 Ka for fixing in DB complete all as specified and directed.
S&F in replacement of MCB SPN 40 Amps 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB . (DB will be measured and paid separately under respective items of sch A)
S&F in replacement of MCB SP 5 to 32 Amps 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB . (DB will be measured and paid separately under respective items of sch A)
S&F in replacement of MCB TPN 63 AMPS 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB . (DB will be measured and paid separately under respective items of sch A)
M&L in replacement of old/damaged earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
M&L for replacement of old damaged PVC Meter Box of suitable size for single phase LT meter. door with 1 Nos of transparent glass of suitable for visibility of meter fixed on door with suitable arrangemnets. meter box shall be fixed in wall and necessary chiseling and meke good of wall to be included in quoted cost.NOTE:-To fix the meter box required disconnecting and refixing of connections to be included in quoted rate.
M& L for preparation of old steel surfaces including welding of LT Panel/bus bar chamber/Jn boxes/metalic meter box with the help of welding machine, after filing nuts,bolts,etc. including locking arrangement and applying one coat of synthetic enamel ivory paint(Smoke grey) to steel surface after disconnecting the electrical connections and reconnection the same at various sites by taking safety precautions after painting complete as specified and directed by Engr-in-Charge.
Arun enterprises
The Rahul Vig
MAHESH KUMAR SINGLA CONTRACTOR
Jawandha Enterprises
Shivam Engg and fabricators
UNITED ENGINEERING CORPORATION
Arneja Builders
Aman Enterprises
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .