| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹48.2 LAccepted-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹57.7 L+₹8.6 L (17.5%)Rejected-AOC | L-2 | Rejected-AOC Being L-2 | |
| 3 | L-3₹60.7 L+₹11.5 L (23.5%)Rejected-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L-3 | Rejected-AOC Being L-3 | |
| 4 | L-4₹61.0 L+₹11.8 L (24.1%)Rejected-AOC 32 GRAND SQUARE DANAPUR CANTT PATNA PIN 801503 | PATNA | PATNA | BIHAR | 801503 | L-4 | Rejected-AOC Being L-4 | |
| 5 | L-5₹62.9 L+₹13.8 L (28.1%)Rejected-AOC | L-5 | Rejected-AOC Being L-5 |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
31 Oct 2022, 6:00 pmClosed
CWE (SUbs) Mumbai
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
SPECIAL REPAIRS TO SENIOR SAILOR MESS (BLDG NO- P-144) AT INS HAMLA
2022_MES_548897_1
8431/E8
Open Tender
Civil Works
Item Rate
270 days
HAMLA
Refer tender documents
8 documents required · 8 mandatory
₹1,000
GE (NW) BHANDUP
₹1.5 L
Yes
9 Dec 2022
31 Aug 2022
2 Nov 2022
31 Aug 2022
31 Oct 2022
18 Oct 2022
Amount
Demolition of cement concrete unreinforced of any type any level and at any position and removal of the demolished material outside MD land complete all as specified.
Taking down cement plaster of any description in any position including racking out joints making key scrubbing down with water etc. and removal of debris out side MD land.
Rendering 5mm thick in (1:3) cm on fair faces of ceiling and other RCC surface of any location and finishing even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick in (1:6) CM on fair faces of brick work or concrete surfaces of walls and finishing even and smooth without using extra cement complete all as specified and directed.
M & L for 20mm (15+5) thick rendering in Cm 1:4 using WPC @ 2% by weight of cement on brick work or concrete surfaces; surfaces finished even and fair with out using extra cement complete all as specified Note : Water proofing compound shall be measured & paid seperately.
Supply only integral water proofing compound.
M&L dismantling of cement concrete unreinforced of any type any level and at any position ensure that structure is at least 3 days old, Bonding Agent Bond coat with a mixing ratio of 1:2 (one part of Shalicryl and two parts of cement). The applied bonding agent should be in tacky condition before topping. Repair mortar Bond coat with a mixing ratio of 1:2 (one part of Shalicryl and two parts of cement) Repair Mortar with a mixing ratio of 1:2:4 (one part of Shalicryl, two parts of cement and four part of sand) applied in specified area.• After the application of Repair mortar to keep the surface moist for 12 - 24 cement complete all as specified Note : Shali Crete (Acrylic polymer Coating) shall be measured & paid seperately as supplied only.
Supply only Shali Crete (Acrylic polymer Coating) water proofing compound.
Demolition of brick work built in CM incl. taking out roots of vegetation if any at any position and removal to out side MD land all as directed by Engr-in-Charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6m mean radius built in CM(1:6) complete all as specified all as directed by Engr-in-Charge.
M &L PCC 1:3:6 type C2 (using 40mm graded stone aggregate) 75mm thick as in plinth protection finished even and fair using extra cement compete all as specified and as directed by Engr-in-Charge.
Taking down Aluminium chawkhats or frame (w/o taking off shutters from the frames) but not exc 1.50 each all as directed by Engr-in-Charge.
Taking down chowkats without taking off shutters of any type from the frame area n. exc 1.50 Sqm each complete all as specified and directed.
Taking down chowkats without taking off shutters of any type from the frame exc.1.50 Sqm and not exc. 4.00 Sqm complete all as directed by Engr-in-Charge.
Taking down shutters of any description exc. 1.00 Sqm & n.exc 2 sqm and refixing in the same opening complete all as directed by Engr-in-Charge.
S&F IInd class hard wood plain solid straight chowkats and framed rebated on the solid rounded put togeather with glue pinned at joints complete all as specified and as directed by Engr-in-Charge.
S&F 2nd class HW 35mm thick glazed and skeleton shutters, open rebated and pepared to receive glass, gauze, etc with sash bar, edges of framing plain, chamfered or rounded, fitted with cut or mitred beads for securing glass, gauze etc sizes of members of shutters as specified in SSR part-1 section 8, clause 8.24 (a); all as specified. ISI marked.
S&F plain framed pannelled shutters of 2nd class HW 35mm thick with panel of 12mm thick ply wood(BWR Quality) and styles as per IS 1003(part-I) all as specified. ISI marked.
S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
M&L painting with synthetic enamel paint of two coats over a coat of pink primer on new wooden surfaces of any description exc. 10 Cm width or girth including preparation of surfaces complete all as specified and as directed by Engr-in-Charge.
M&L applying one coats of synthetic enamel paint on old wooden surfacesof any desccription exc. 10cm width or girth incl. preparation of surfaces complete all as specified and as directed by Engr-in-Charge.
M&L for MS hold fasts size 25x6mm FI and similar articles confirming to Fe-290 Gde E-165 fixed to chowkats complete all as specified and as directed by Engr-in-Charge.
M&L providing PCC 1:2:4 type B1 (using 20mm graded stone aggregate) cement concrete in bed blocks for hold fasts complete all as specified and as directed by Engr-in-Charge.
S&F stainless steel butt hinges medium weight 100mm long complete all as specified and as directed by Engr-in-Charge.
S&F aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed by Engr-in-Charge.
S&F alluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alluminium alloy and fixed of length of bolt 300 mm complete all as specified and as directed by Engr-in-Charge.
M&L extruded aluminium alloy handles, fabricated type, anodised 150mm size complete all as specified and as directed by Engr-in-Charge.
Dismantling stone slabs or pcc tiles of any description or thickness in steps, landing, flooring and similar work laid, bedded and pointed in cement mortar complete complete all as specified and as directed by Engr-in-Charge.
M&L for 20 to 25mm machine cut kota stone slab in single piece with round nosing with three numbers of serration as in treads of steps for staircase laid over cement screed bed and jointed with grey cement slurry mixed with pigment to match the shade of of the slab including rubbing and mirror polishing and including over 15mm thick screed bed or bedding layer in CM1:4 complete all as specified and as directed by Engr-in-Charge.
M&L for 18 to 20mm machine cut kota stone slab as in riser of steps, skirting, dado and pillar, cills and jambs laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with beewax polishand including 15mm thick screed bed or bedding / backing layer in CM1:4 complete all as specified and as directed by EIC
M&L machine cut kota stone slab flooring 20 - 25mm thick 450/550x550/600mm over 20mm cement screed in CM 1:6 laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including mirror polishing complete all as specified and as directed by Engr-in-Charge.
M&L Marble work other than white or black/Baroda green 18 to 20 mm thick (table rubbed and polished) in cooking platforms, jambs and like over and including provision of 20mm thick cement mortar (1:4) including pointing in colour cement (1 :2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed.
M&L Providing edge moulding to 18-20mm thick Marble stone of counters vanities etc or similar including machine polishing to edge to give high gloss finish etc. complete all as specified and as directed by Engr-in-Charge.
S&F aluminium section in doors/windows/ventilators ,any type, powder coated in approved colour (Thickness of powder coating not less than 50 micron), aluminium section (medium weight of series 'B') or section as directed by Engineer-in-Charge, cut to size, jointed together with cadmium plated steel screws including rubber and aluminium beading or gasket for aluminium sections for fixing glass/XPM jali / aluminium wire cloth and all necessary fittings such as hinges, handles, rollers, screws, plugs etc. as required all as per relevant IS, provisions and approved manufactures etc. all as specified and directed Notes : (i) Weight of aluminium sections shall only be measured. (ii) The supply only rate of bakelite sheet glass pane,wire mesh, aluminium wire cloth will be measured separately.
Supply only sheet glass 4.8 mm thick in glazing complete as specified and directed.
Supply only 4mm thick figured glass/pin headed type ordinary quality fixed in aluminium ventilator all as specified & as directed by EIC.
Supply only Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples
S&F aluminum anodised grill DG- 102 ( 10 mm x 7.5mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed.Note : (i) Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE.(ii) Minimum thickness of anodizing shall be 15 microns.
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed.
S&F solid PVC door frame(chowkhat) of size 50mmx47mm made out of 5mm plain dark colour PVC sheet reinforced with MS square tube etc complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top& bottom rails. MS frame shall be covered with heat moulded plain dark colour PVC 'C 'Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain dark colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail& bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with suitable PVC sheet beading and joined together with solvent cement, etc fixed to frame complete all as specified and directed.
S&F in repairs floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor of 140mm size complete all as specified and as directed by Engr-in-Charge.
Supply only PVC flushing cistern 10 ltrs capacity high/low level with inlet, ball valve, float and handle including brackets complete all as specified and as directed by Engr-in-Charge.
M&L for cement concrete Type E2 1:5:10 (using 40 mm graded stone aggregate) as in lean concrete complete all as specified and directed
M & L for special treatment for sunken portion of WC's, Bath, toilet, kitchen etc executed in following stages :- Stage 1: Providing 15mm thick plaster in CM 1:3 mixed with water proofing chemical of Dr.Fixit or Shalicrete 'R' of STP Ltd in the proportion/quantity all as per manufacturer's instructions. State 2 : Primer-Mix Tarfelt LM of STP Ltd (diluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfaces. Stage 3 : Application of 1st coat of Tarfelt LM of STP Ltd (without dilution with water) @ 1Kg/Sqm by brush all as per manufactuer's instructions. Stage 4: Laying fyber glass cloth (weight not less than 50gram/ Sqm) over the 1st coat while the coated surface is still sticky. Stage 5: After 6 to 7 hours interval, apply second coat i.e. final coat of Tarfet LM of STP Ltd (without Dilution with water) @ 1kg/ Sqm by brush as per manufacturer's instructions. Stage 6: Providing 10mm thick protective plaster in CM 1:3 mixed with STP No. 1 @ 250ml/50 Kg cement all as per manufacturer's instructions. Stage 7: Carryout ponding test for 48 hours to ensure water tightness of repaired sunken portion. NOTES :(i) Mode of measurement: Actual area treated (floor and adjoining walls) will be measured and paid. (ii) The above treatment shall be got executed through authorised applicator of manufacturer and necessary authenticated documents on account of above shall also be produced by the contractor.
S&F in repairs vitreous china wash down water closet pan (padestal pattern), white complete including seat cover and connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specified and directed.
S&F in repairs vitreous China squatting pan, 'orrisa' pattern WC of size 580 x 440 mm white with integral foot rest (excluding flushing cistern and flush pipe but including 'P' or 'S' trap and provision of lime concrete bedding in repairs. Note:- For item No. 46 & 47 flushing cistern and flush pipe will be measured and paid under supply only rate.
M&L Wash basin, Vitreous China white (Flat back) 630 x 450mm including brackets,, pinning in ends of brackets or erecting stand including fixing of waste pipe and pillar type etc ( Suppy of pillar tap and waste pipe shall be measured separately) complete all as specified and directed.
Supply only pillar tap 15 mm bore cast copper alloy chromium plated fancy type complete all as specified and directed.
Supply only waste fitting of 32 mm bore, brass, chromium plated for glazed ware wash basin etc
M&L in repairs stop valves 15mm bore dia, cast copper alloy fancy type, chromium plated with long shank and cup concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs bib tap 15mm bore fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for unions complete all as specified and directed...
S&F 15mm size PVC connection with PTMT nuts 450mm length complete all as speified and directed.
S&F in repairs chromium plated shower roses 125mm size with or without swivel joint including fixing to steel pipe or union etc.
S&F in repair CP brss Tubular towel rail with hook 20 mm dia 600mm long between flanges of fixed with and including chromium plated brass screws and wooden/plastic screws. complete all as specified and directed.
S & F 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 PVC bends including all necessaryfixed complete to walls, ceilings or in floors etc.
S & F in repairs cast iron Nahani trap in floors with grating including jointing to waste pipe of 100 mm dia in cement concrete type B1 (1:2:4).
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc complete all as specified and directed.
M&L PCC 40mm thick type B0, 1 : 2 : 4 (12.5 mm graded aggregate) in sub flooring complete all as specified and directed..
Material and Labour non skid coloured ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not excceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6.
M&L glazed ceramic jointless coloured tiles in vertical surface 450 x 300 x 7mm set and jointed in neat cement slurry over and including provision of backing layer 10mm thick in CM 1 : 3 complete all as specified and directed.
Taking up or down 15 mm bore GI tubing from wall, floor, ceiling.
All as per item No 63.00 here in above but 20 mm bore
All as per item No 63.00 here in above but 40 mm bore but 40 mm bore
S&F GI tube medium grade of 15 mm bore with all fittings and fixed complete to walls and ceilings or laid in floors etc
All as per item No 66.00 here in above but 20 mm
All as per item No 66.00 here in above but 40 mm
Taking down cast iron soil waste pipe (any size or patterns) moulding all fittings heads, shoes, bends etc. (Measured over all as fixed along the concrete line over fittings and accessories).
S&F 100mm dia spun cast iron pipe jointed with cement joint and fixed to walls including cutting of holes wherever required complete all as specified and directed.
S&F 100mm dia CI bends including cutting of holes complete all as specified and directed.
S&F 100mm dia CI branch pieces, double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches and cutting of holes, with cement joints complete all as specified and directed.
S&F CI cowl 100mm dia complete all as specified and directed.
S&F 75mm dia CI spun cast iron pipe jointed with cement joint and fixed to walls including cutting of holes wherever required complete all as specified and directed.
S&F 75mm dia CI bends including cutting of holes complete all as specified and directed.
S&F 75mm dia CI branch pieces, double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches and cutting of holes with cement joints complete all as specified and directed.
S&F CI cowl 75mm dia complete all as specified and directed.
M&L for preparation of new plastered walls surfaces & applying two coats of chemical waterproofing treatment (601 raincoat of pidilite or equivalent) on wall & chajja, terrace & parapet wall, such as Flexcoat, Beckcoat, Exshield etc or equivalent including filling of cracks in walls/concrete with " Crack-X" of pidilite or equivalent complete as per manufactures instructions, all as specified and directed.
M&L for complete removal of existing treatment over wall surfaces including washing / rubbing down with water of wall and applying two coats of chemical waterproofing treatment (601 raincoat of pidilite or equivalent) on wall & chajja, terrace & parapet wall, such as Flexcoat, Beckcoat, Exshield etc or equivalent including filling of cracks in walls/concrete with " Crack-X" of pidilite or equivalent including preperation of old surfaces complete as per manufactures instructions, all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper with roller over one coat of alkali resistant primer including application of 3mm wall care putty for smooth finish.etc complete all as specified and directed .
M&L for complete removal of existing treatment over wall surfaces including washing / rubbing down with water of wall and applying two coats of oil bound distemper over a coat of primer including application of 3mm wall care putty for smooth finish.etc complete all as specified and directed .
M & L for preparation of new plastered surfaces on ceilings and applying two coats of oil bound distemper with roller over application of 3mm putty complete all as specified and directed.
M&L for complete removal of existing surfaces on ceiling and applying two coats of oil bound distemper with roller over application of 3mm putty complete all as specified and directed.
Dismantling of boarding ,any description and in any position complete all as specified and directed
M&L for 18/19mm thick prelaminated particle board with teak wood beading, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
M&L for 2nd class hardwood moulding n. exc 6 sqcm as in cornices, picture rails and the like such as in prelaminated particle board complete all as specified and directed.
S&F continous (piano) hinges, mild steel, bright finish or electro-galvanised complete all as specified and directed.
S&F 150mm size hasp & staple, aluminium anodised, safety type, including bolt to hinge plate and fixed with screws complete all as specified and directed.
M&L in repairs Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted & fixed in position all as specified of 2000 ltrs capacity complete all as specified and directed.
M&L in repairs Ball valve high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete 25mm dia complete all as specified and directed.
M&L Nipple suitable for HDPE water tank (minimum weight 25mm - 65 gms) 25mm bore dia complete all as specified and directed
S&F in repairs 40 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed by Engr-in-Charge.
S&F in repairs 25 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed by Engr-in-Charge.
S&F 20mm dia aluminium alloy curtain rail fixing with bracket, stops, rollers etc complete all as specified and directed.
M&L for post construction anti- termite treatment along the external wall below concreate or masonary apron using chemical emulsion @2.25 litre per linear metre including drilling and plugging holes with cement mortar 1:2 to match the existng floor etc complete all as specified and directed.
M & L for post construction anti - termite treatment at points of contact of wood work using chemical emalsion (in oil or kerosene based solution ) @ 0.5 litre per hole by drilling 6 mm dia holes at a down ward angles of 45 degree at 150 mm centre to center and sealing the same with white cement and making good to the existing surfaces etc complete all as specified and directed.
M&L for post construction anti- termite treatment of soil / concreate under existing floor along the floor and wall junction using chemical emulsion @ 1 litre per hole 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floor etc complete all as specified and directed.
Chipping, removing carefully loose/damaged concrete incl plastering (total thickness upto 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breaker without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on reinforcement bars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. Note: (1) Anchoring of reinforcement bars will be measured and paid seperately under item No 107. (2) This item is applicable for additional bars requied in the existing RCC structures.
M&L for Anticorrosive treatment to reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application complete all as specified and directed.
M&L for providing Polymer Bonding Agent of Make M/s. Krishna Conchem (MONOBOND) OR Fosroc (NITOBOND-SBR) OR equivalent brand of Dr. Fixit,as approved by the GE followed by flexible polymer based putty ( 1cement: 1.2 finesand :20% polymer by weight of cement : water as required ) on cracks after cutting the cracks to a 'V' shaped groove upto 10 mm wide and 10 mm deep in structural RCC members , finished with spatula etc. complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 40mm in thickness) with prebatched, prepacked, single component ready to use microconcrete from M/s. Krishna Conchem (Molith MC) or equivalent of Dr. Fixit as approved by GE at any level and at any lead or lift as directed including prefabricated water tight formwork centering, scaffolding, also including mixing, laying, levelling, finishing, curing etc as per manufacturer's specifications complete all as specified and directed.(Note : Reinforcement only shall be measured and paid separately).
M&L for building up the profile of structural members using polymer modified mortar from M/s. Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 20mm thickness including levelling, profiling etc complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified from M/s Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr. Fixit, exceeding 20mm thick and not exceeding 40mm thick in two layers each of equal thickness including levelling, profilling etc complete all as specified and directed.
M&L for anchoring & welding reinforcement bar in existing RCC member by providing holes of minimum 10d depth for bars upto 16 mm dia and grouting in position with locfix (fosroc), including drilling of holes, cleaning etc. complete all as specified and directed, Note:-reinforcement will be measured and paid for separately.
Demolition of RCC Chajjas, slabs, beams and similar work by chiselling and cutting the reinforcement all as directed.
S & F premoulded FRP chajjas with 2 to 2.5 mm FRP thickness on both sides with manglore clay type finished with 150 mm drop on front, sides and 60 mm collar on back side including fixed flat iron 50x5 mm with bolts nut (Hold fast type) necessary fixtures complete all as directed.
Demolition of the existing brick coba treatment over roof slab completely including throughly cleaning complete all as specified and Removal of the demolished material to outside MD land.
M&L for PCC 1:2:4Type B0 (using 12.5 mm graded aggregate) with 2% water proofing compound by weight of cement or as per manufacturer's instructions water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface making rounded or chamferred on edges and including formwork etc all as specified and directed.
Supply and Application of 5 Layer SHR waterproofing Coating system on leaking concrete surface by thorough surface preparation followed by one absorption coat of thermacool WP 51, nano-tech modified. UV resistant elastomeric clear coat having min 50% solids, then overcoating with 2 coats of thermacool WP51+cement mixture as waterproofing coat having +450% elongation. Tensile strength min 2 2 MPa and then top-coated with 2 Coated with 2 Coats of thermacool 0.3 C pure acrylic based. UV resistant, non- yellowing bio-organism resistant (anti-fungal, anti-bacterial) solar IR heat reflective coating conforming to BIS STD is 17218:2019 with pull off adhesion 2.8 Mpa passes 2000 hrs accelerated durability test, suitable for all types of cementations surfaces, white colour matt surface coverage 3.25 sqm/Ltr/2 coat, DFT 100-120 microns using brush, roller airless spray gun as applicable. The product should have been tested at IIT or NABL approved Lab and application is to be done by thermacool approved applicator only
M&L for Mirror polishing on old marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete all as directed.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for reuse or credit and making good distrubed surface of wall, floors etc all as specified and directed.
Taking down main switches DBs with sheet metal enclosure 2/4/6/8 way SPN/TPN/DBs,Meter Boxes etc all as specified and directed.
Taking down of existing ceiling fans, opening / dismantling of fan& fan blades, cleaning, servicing,oiling, greasing, carrying out repairs such as replacement of capacitors, bearings, bushes, canpoy, condensor, clamp, safety pin, rubber bush and reassembling the fan & fan blades,, connecting up, testing and re-fixing of the same ceiling fan of any sweep including provision of new cable from ceiling rose/ connector to fan and spray painting of ceiling fan with two coats of synthetic enamel paint after prepartion of surfaces,complete all as specified and directed
Taking down of existing exhaust fan 300 mm size (12") A C single phase 230 Volt and deposting the same to MES store yard complete all as specified and directed
M & L for point wiring complete with proper colour coding using 1100 volts grade, 1.5 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good the same in CM 1:3 to match with existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also inclduifng 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for one light point/fan/bell point controlled by one one way switch, complete all as specified and directed
All as per item No 118.00 here in above but for one 5 pin socket 5 Amps on same board complete all as specified and directed.
All as per item No 118.00 here in above but for one 5 pin socket outlet 05 Amp independent board complete all as specified and directed
M & L for point wiring complete with proper colour coding using 1100 volts grade, 2.5 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good the same in CM 1:3 to match with the existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc. also inclduifng 2.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for one 5Pin,6/16Amps,Socket outlet independent,complete all as specified and directed
Supply & fixing ceiling rose , surface /PVC/polycarbonate, isolated body 3 terminal complete .
Supply & fixing modular fan regulator,120W- 1 module
Supply & fixing switch modular type 6 Amp single pole one way 230V completed
Supply & fixing switch modular type 16 Amp single pole one way 230V completed
Supply & fixing socket modular type 6 Amp 2/3 pin single pole one way 230 V complete
Supply & fixing socket modular type 16 Amp 2/3 pin single pole one way 230 V complete
Supply & fixing Modular white cover plate with frame 8/6 Module
Supply & fixing Modular white cover plate with frame 3 Module
Supply & fixing Modular white cover plate with frame 1/2 Module
Supply & fixing modular Metal Flush box 6/8 Module
Supply & fixing modular Metal Flush box 3 Module
Supply & fixing modular Metal Flush box 1/2 Module
Supply and fixing integrated sleek extruded LED channel with acrylic cover 20 watt with white light including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected. Make :Havells cat part No. LHEXBLP7PN1W020 or any equivalent of Crompton/Philips/Shakti
Supply and fixing integrated sleek extruded LED channel with acrylic cover 10 watt with white light including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected. Make :Havells cat part No. LHEXACP5IN1W010 or any equivalent of Crompton/Philips/Shakti
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers, suitably embedded in wall(include wall cutting for hole) with provisioning of 23/0.0076 flexible three core wire for electrical connections from ceiling rose to fan all as specified and directed.Make :Crompton/Havells/Orient or any equivalent specifications make as approved by the GE.
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces.
M&L for sub main wiring complete two run of size 2.5 sqmm PVC insulated ,unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable ,drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good in CM 1:3 to match with the existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 2.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continous earth wire connected to common earth dolly and mains, complete all as specified and directed. Note: Three run 2.5 Sqmm PVC cable and one run of Casing Caping & conduit will be measured as "one unit"length.
M&L for sub main wiring complete two run of size 4.0 sqmm PVC insulated ,unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable ,drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good in CM 1:3 to match with the existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 4.0 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continous earth wire connected to common earth dolly and mains, complete all as specified and directed. Note: Three run 4 Sqmm PVC cable and one run of Casing Caping & conduit will be measured as "one unit"length.
Supply and fix in repairs sheet metal enclosure powder painted MCCB DB TPN 415 Volts 4 way double door vertical type with 200 Amps rated bus bar din rail neutral link with suitable for MCCB as incomer and concealed in wall all as specified and directed. Make : Havells cat part No-DHDLVDRWGOFO04 or equilant Schnider/Siemens/Standard
Supply & fix sheet metal enclosure powder coated for MCB DB SPN 12 way 240 volts double door with din rail and bus bar including making good to the disurbed surface matching with the existing complete alla s specified and directed.
Supply & fix sheet metal enclosure powder coated for MCB DB SPN 8 way 240 volts double door with din rail and bus bar including making good to the disurbed surface matching with the existing complete alla s specified and directed.
Supply & fix sheet metal enclosure powder coated for MCB DB SPN 2 way 240 volts Single door with din rail and bus bar including making good to the disurbed surface matching with the existing complete alla s specified and directed.
Supply and fix MCCB 415 volts 16 KA Four pole 63 Amps fixed type complete all as specified.
Supply and fix MCB TPN 415 volts 40 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Supply and fix MCB SPN 240 volts 32 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Supply and fix MCB SPN 240 volts 40 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Supply and fix MCB SP 240 volts 6 to 32 Amps breaking capacity 10 KA 'B' Series rating complete all as specified and directed.
Supply and fix MCB SP 240 volts 40 Amps breaking capacity 10 KA 'B' Series rating complete all as specified and directed.
M & L for cutting chases for concealed water tubing not exc 10cm girth, pinning in making good to facing and pointing in cement mortal 1:3 complete all as specified and directed. Including fixed flat iron 50x5 with screw bolts
Supply & fixing street light of capacity 15 watt with IP 65 protection for external outdoor lightning including provision of GI supporting pipe 25mm dia with 45° angle bend with clamps and bolts to be fitted on wall all as specified and directed by the Engineer-in-Charge. Make :Havells cat part No. ENDURAPEARLSL15WLED757SASYTOPCMP or any other equivalent of Bajaj/Crompton/Shakti
Material and labour for earthing complete with GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to GI earth strip 32X6 mm by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe 40 mm dia medium grade including testing on completion all as specified and directed.
S R INFRASTRUCTURE
Vishal Builders
M/S Kumar Enterprises
KAJAL CONST.
the bhimani group of companies
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .