| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.0 LAdmitted-Finance GP RAM COLONY AMRITSAR JALANDHAR 144103 | AMRITSAR | AMRITSAR | PUNJAB | 144103 | L1 | Admitted-Finance | |
| 2 | L2₹48.6 L+₹2.5 L (5.51%)Admitted-Finance VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L2 | Admitted-Finance | |
| 3 | L3₹50.4 L+₹4.3 L (9.42%)Admitted-Finance CHOMO JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | AAR KAY BEE ENTERPRISES L1 | M/s Sahib and Company L2 | LABH SINGH AND SONS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in SOFT/LOOSE soil complete, all as specified & directed. | 80 | Square Metre | 115 ₹9,200 | 60 ₹4,800 Lowest | 500 ₹40,000 |
| 2.00 | Excavation over areas in SOFT/LOOSE soil not exceeding 1.50 metre deep and getting out complete, all as specified. | 80 | Cubic Metre | 145 ₹11,600 Lowest | 230 ₹18,400 | 400 ₹32,000 |
| 3.00 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified & directed. | 24 | Cubic Metre | 90 ₹2,160 | 80 ₹1,920 Lowest | 600 ₹14,400 |
| 4.00 | Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified & directed. | 55 | Cubic Metre | 130 ₹7,150 Lowest | 160 ₹8,800 | 500 ₹27,500 |
| 5.00 | M&L for PCC type D-2 (1:4:8), using 40 mm graded crushed stone aggregates as in filling & mass concrete, complete all as specified & directed. | 7 | Cubic Metre | 3,850 ₹26,950 | 3,800 ₹26,600 Lowest | 6,000 ₹42,000 |
| 6.00 | M&L for PCC type B-2 (1:2:4), using 40 mm graded crushed stone aggregates as in filling & mass concrete, complete all as specified & directed. | 45 | Cubic Metre | 5,520 ₹2,48,400 Lowest | 6,200 ₹2,79,000 | 6,000 ₹2,70,000 |
| 7.00 | M&L for Reinforced cement concrete, type A-1 (1:1½:3), (nominal mix) , as in in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified. | 25 | Cubic Metre | 6,850 ₹1,71,250 Lowest | 6,900 ₹1,72,500 | 8,000 ₹2,00,000 |
| 8.00 | M&L for Reinforced cement concrete, type A-1 (1:1½:3), (nominal mix), as in beams, cantilevers, bressumers, lintels over 1.5 metre clear span and the like complete all as specified and as directed. | 15 | Cubic Metre | 6,950 ₹1,04,250 Lowest | 7,500 ₹1,12,500 | 8,000 ₹1,20,000 |
| 9.00 | M&L for Reinforced cement concrete, type A-1 (1:1½:3), (nominal mix) , as in columns, pillars, piers, posts and struts complete all as specified and directed. | 25 | Cubic Metre | 7,150 ₹1,78,750 Lowest | 7,500 ₹1,87,500 | 8,000 ₹2,00,000 |
| 10.00 | Supply only water proofing compound, ISI marked, complete all as specified & directed. | 100 | Kilogram | 71 ₹7,100 Lowest | 80 ₹8,000 | 120 ₹12,000 |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
6 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sachin Kumar IDSE EE GE AF Adampur
Military Engineer Services AF Stn Adampur 144103
PROVN OF HIGH WALL ENCLOSURE OPPOSITE TO MAIN GATE, PROVN OF RAISED PLATFORM FOR GUARD NEAR MAIN GATE AND CERTAIN REPAIRS TO ROOF AND MISC WORKS IN DOMESTIC AREA AT AFS ADAMPUR
2025_MES_729967_1
GE(AF)/ADM/T-60 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
Under GE AF Adampur
As per NIT Documents
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹98,000
Yes
14 Nov 2025
9 Sept 2025
7 Oct 2025
9 Sept 2025
6 Oct 2025
23 Sept 2025
9 Sept 2025 - 22 Sept 2025
Amount
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in SOFT/LOOSE soil complete, all as specified & directed.
Excavation over areas in SOFT/LOOSE soil not exceeding 1.50 metre deep and getting out complete, all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified & directed.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified & directed.
M&L for PCC type D-2 (1:4:8), using 40 mm graded crushed stone aggregates as in filling & mass concrete, complete all as specified & directed.
M&L for PCC type B-2 (1:2:4), using 40 mm graded crushed stone aggregates as in filling & mass concrete, complete all as specified & directed.
M&L for Reinforced cement concrete, type A-1 (1:1½:3), (nominal mix) , as in in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
M&L for Reinforced cement concrete, type A-1 (1:1½:3), (nominal mix), as in beams, cantilevers, bressumers, lintels over 1.5 metre clear span and the like complete all as specified and as directed.
M&L for Reinforced cement concrete, type A-1 (1:1½:3), (nominal mix) , as in columns, pillars, piers, posts and struts complete all as specified and directed.
Supply only water proofing compound, ISI marked, complete all as specified & directed.
M&L for Brick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified & directed.
M&L for Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces of concrete, complete all as specified and as directed.
M&L for Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished surfaces of concrete, complete all as specified and as directed.
M&L for Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surfaces of concrete, complete all as specified and as directed.
Taking down existing water proofing treatment (any no. of layers) from RCC roofs including cleaning the surface including flashings and junction of parapet etc. with wire brushing & water to the entire satisfaction of EIC, complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm graded stone crushed aggregate, laid to slope as directed by Engineer in Charge over RCC roofs as padding, complete all as specified and directed.
Cleaning the surface and made free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expantion contraction. Cutting the grooves with suitable cutter machine in "v" groove filled with Repair mortar/Microconcrete/General purpose grout as recommended proportionaly as per recommendation of manufacturer.Making of Gollas at all the corners with Polymer modified mortar(1:4 Cement:sand with 3.5% Acylic of cement weigth) and " Supplying and applying High build elastomeric waterproofing coating based on pure, hydrophobic polyurethane, cold applied of spray / brush applied, membrane with an elongation of 280% and tensile strength of 2.7 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88 % solid content. The system includes final base preparation, epoxy primer 1:1(Resin:hardner) application with 100 % water dilution and Pure polyurethane application in 2 coats with a total min consumption of 1.25 Kg per SQM and glass fibre mesh of 2.5mmx2.5mm needs to be sandwiched b/w two coats complete all as specified and directed. NOTE: Application should be done with Graco sprayer by a company authorised applicator.
Cleaning the surface and made free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expantion contraction. Cutting the grooves with suitable cutter machine in "v" groove filled with Repair mortar/Microconcrete/General purpose grout as recommended proportionaly as per recommendation of manufacturer and applying FOSROC nitoproof 650PU over a priming coat of FOSROC Nitoproof WB primer or equivalent product of asian paints, M/s MC Bauchemie/ CIPY/SIKA/ Pidilite/ DR Fixit/ Thermax STP/ Berger Paints applied as per manufacturers instructions. Further provide a polypropylene/ polyster non woven geotextile fabric of 150 GSM. Followed by cement screed 15mm in CM (1:4) in slope, over that 20mm thick teracotta burnt tiles are laid. while laying the tiles, care should be takeb to see that joints are throughly filled with FOSROC Nitotile grout polymer based joint mortar or equivalent product of asian paints M/s MC Bauchemie/ CIPY/SIKA/ Pidilite/ DR Fixit/ Thermax STP/ Berger Paints as per manufacturers instructions compete all as specified and directed. NOTE: (i) Brick tiles should be measured and paid separately. (ii) Application should be done with Graco sprayer by a company authorised applicator.
M&L for 20 mm thick teracotta burnt tiles bedded over 15 mm thick cement mortar (1:4), and joints grouted with FOSROC Nitotile grout polymer based joint mortar or equivalent product of asian paint M/s MC Bauchemie/ CIPY/SIKA/ Pidilite/ DR Fixit/ Thermax STP as per manufacturer instructions complete all as specified and directed.
M&L for mild steel work such as joist, angle or tee sections, fixed independently without connecting plates etc. (Cut to ordinary length i.e within 20mm of the length indicated) quality confirming to Fe-290-Gde E-165, complete all as specified and as directed.
S&F Rolled mild steel as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, quality confirming to grade Fe-290-Gde E-165, complete all as specified.
S&F Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections of grade Fe 410-W (Grade E-250), complete all as specified.
S&F mild steel anchor bolts for fixing gusset plates dia of each bolt exc 20 mm but n exc. 25 mm complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Mild steel TMT bars 5 mm and over up to and including 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified.
Granite jet black shade, 15-18 mm thick,as in step, jambs, cooking platform and like, machine cut, machine polished, bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified and directed.
Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified.
M&L for Glazed ceramic coloured tiles not less than 7mm thick, area of each tile exc. 1.00 Sq.m but n. exc. 1.50 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 10 mm thick bedding layer in cement mortar (1:4), complete all as specified and as directed.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified & directed. NOTE: WPC will be measured and paid for separately under respective item of BoQ.
M&L for Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed).complete all as specified. (b) Two coats of exterior acrylic emulson over and including a coat of water based exterior primer complete all as specified.
S&F, uPVC pipes 110 mm external dia, type-A, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed as Rainwater pipes, IN REPAIRS, complete all as specified and directed.
S&F, uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 110 mm external dia, IN REPAIRS, complete all as specified and directed.
M&L for cutting of existing uPVC/PVC pipe of any dia for lowering pipes during roof treatment, complete all as specified and directed.
Taking down cement plaster of any description on brick walls or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.d
Dismantling wrought iron mild steel works or of any description in any position not otherwise specfically provided complete all as specified and directed.
Demolition of mud phuska in roofs of thickness not exceeding 200 mm including leaping plaster complete all as specified
Dismantling brick tiles in roof laid dry and pointed in cement mortar complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified
NOTE: (i) Roof treatment must be done from authorized applicator only. (ii) MOU needs to be signed between the company and the applicator. (iii) The applicator must be on payroll of company. (iv) Contractor shall procure the roof treatment material after approval of make from GE in three equal parts, 1st part within 15 days of commencement and rest 2 parts at equal intervals or earlier if required and to be kept in Engr in Charge Custody
M/s Sahib and Company (BID ID -3444098)
LABH SINGH AND SONS (BID ID -3443150)
stage.html
html • 0.04 MB
technical_817234.pdf
techsummary_817234.pdf
finance_817234.pdf
BOQ Comparative Chart
xlsx
cancelled_1.pdf
pdf • 0.15 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
Tender602526.pdf
Tender Documents • 1.27 MB
BOQ_817234.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .