Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance NOT FOUND | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
2 Sept 2021, 6:00 pmClosed
GE (AF) SIRSA
GE (AF) SIRSA
AMC FOR FIRE FIGHTING AND FIRE ALARM SYSTEM , AMC FOR LIFT PASSENGER AT SMC BUILDING AND NEW ATC AND REPAIR / MAINTENANCE OF FIRE FIGHTING ALARM SYSTEM AT AF STN SIRSA
2021_MES_466187_1
GE/SRA/T-40 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
273 days
GE (AF) SIRSA
As per Tender Documents and NIT
3 documents required · 3 mandatory
₹500
Yes
GE (AF) SIRSA
₹26,000
Yes
7 Sept 2021
7 Aug 2021
4 Sept 2021
7 Aug 2021
2 Sept 2021
20 Aug 2021
7 Aug 2021 - 17 Aug 2021
Amount
Annual Maintenance Contract for Fire Fighting System, Fire Alarm & Fire Detection System at ATC, complete all as specified and as directed comprising of the following :- Fire Fighting System :- (a) Fire Fighting Panel - 01 No. (b) Jockey Pump 10 HP - 01 No. (c) Electric Driven Pump 75 HP - 01 No. (d) Diesel Engine Driven Pump 75 HP - 01 No. (e) Fire Hydrant Landing Valve - 16 No. (f) Hose Box - 10 No. (g) Branch Pipe - 10 No. (h) Hose Reel Drum - 10 No. (j) Hose 15 Metre Long - 10 No. (k) Fire Hydrant Stand Post - 06 No. (l) CI Sluice Valve 80mm - 05 No. (m) Fire Brigade - 01 No. (n) CI Non Return Valve 100mm-05 No. (o) CI Foot Valve 100mm - 03 No. (p) MS ERW Pipe 150mm - 185 RM (q) MS ERW Pipe 100mm - 209 RM (r) MS ERW Pipe 80mm - 95 RM (s) GI Heavy Duty Pipe 80mm - 12 RM (t) GI Heavy Duty Pipe 40mm - 190 RM (u) GI Heavy Duty Pipe 25mm - 160 RM (v) Sprinkle Glass Tube type - 92 No. (w) Sprinkle Glass Tube Upright type- 59 No. Fire Detection & Alarm System :- (a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 05 No. (c) Smoke Detectors - 58 No. (d) Heat Detectors - 58 No. (e) Manual Call Point - 14 No. (f) Control Module - 59 No. (g) Fault/ Short Circuit Isolator - 05 No. (h) Remote Response Indicator - 116 No (j) PVC Conduit Pipe 25mm - 850 RM (k) Copper Flexible wire - 1660 RM (Note- Old U/S part will be replaced and paid seperatelly under respective item)
Annual Maintenance Contract for Fire Alarm & Fire Detection System at WSA, complete all as specified and as directed comprising of the following :- Fire Detection & Alarm System :- (a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 05 No. (c) Smoke Detectors - 58 No. (d) Heat Detectors - 58 No. (e) Manual Call Point - 14 No. (f) Control Module - 59 No. (g) Fault/ Short Circuit Isolator - 05 No. (h) Remote Response Indicator - 116 No. (j) PVC Conduit Pipe 25mm - 850 RM (k) Copper Flexible Wire - 1660 RM (Note- Old U/S part will be replaced and paid seperatelly under respective item)
Annual Maintenance Contract for Lift of 08 Passenger/ 544 Kg at ATC as per Terms and Conditions given as follows :- (a) Servicing of Lift at Regular Intervals and as Frequently as the Company deems necessary based on the Age, Nature and Condition of the Elevator and take all Reasonable Care and Maintaining of Lift Equipment in Safe and Proper Working Condition. (b) Carry out the Servicing Work as required whenever possible on a Day including Sundays & Holidays and during Regular Working Hours. (c) Replenish the Gear and Motor bearing with necessary Manufacturer recommended Lubricants whenever necessary and All Parts of the Lift will be checked, cleaned and lubricated to keep them, both Mechanically and Electrically in Perfect Working Condition. Replacement of Unserviceable Parts will be included in Quoted Unit Rate. (d) Carry out according to its Standards Customary Annual Safety Test to Examine All Safety Devices. (e) Lift AMC will be as per Terms and Conditions of SCHINDLER Company. (f) Contractor has to submit AMC within 20 Days after Acceptance of Tender. If the Contractor fails then necessary Recovery will be made as per Terms and Conditions of the Contract. NOTE : Contractor is responsible for Working and Inspection of Registration for the Year 2019-20 of Lift by Lift Inspector Cum Executive Engineer, Electrical Inspectorate, Haryana - Hisar is included in Quoted Unit Rate.
Annual Maintenance Contract for Lift of 06 Passenger/ 408 Kg at SMC as per Terms and Conditions given as follows :- (a) Servicing of Lift at Regular Intervals and as Frequently as the Company deems necessary based on the Age, Nature and Condition of the Elevator and take all Reasonable Care and Maintaining of Lift Equipment in Safe and Proper Working Condition. (b) Carry out the Servicing Work as required whenever possible on a Day including Sundays & Holidays and during Regular Working Hours. (c) Replenish the Gear and Motor bearing with necessary Manufacturer recommended Lubricants whenever necessary and All Parts of the Lift will be checked, cleaned and lubricated to keep them, both Mechanically and Electrically in Perfect Working Condition. Replacement of Unserviceable Parts will be included in Quoted Unit Rate. (d) Carry out according to its Standards Customary Annual Safety Test to Examine All Safety Devices. (e) Lift AMC will be as per Terms and Conditions of JOHNSON Company. (f) Contractor has to submit AMC within 20 Days after Acceptance of Tender. If the Contractor fails then necessary Recovery will be made as per Terms and Conditions of the Contract. NOTE : Contractor is responsible for Working and Inspection of Registration for the Year 2019-20 of Lift by Lift Inspector Cum Executive Engineer, Electrical Inspectorate, Haryana - Hisar is included in Quoted Unit Rate.
S& F in repairs Automatic Rescue device with mother board suitable for lift complete all as specified and directed by eingneer-in-charge.
S& F in repairs fire hydrant landing valve type A single head outlet of 63 mm dia complete all as specified and directed by eingneer-in-charge.
S & F in repairs Hose Box made of 18 gauge MS steel of min size 800mx600m250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside box complete all as specified suitable to house 02 Nos hose reel drum 02 Nos Gun metal nozzle complete all as specified and directed by eingneer-in-charge.
S & F in repairs Branch pipe gun metal 63mm instantaneous inlet made threaded outlet 15mm bore nozzel short complete all as specified and directed by eingneer-in-charge.
S & F in repairs of Hose reel Drum suitable for hose pipe of size 63 mm and up to all as specified and directed by eingneer-in-charge.
S & F in repairs 63 mm dia Hose 15 mtr long canvas hose including taking down existing complete with male female coupling complete all as specied and directed by eingneer-in-charge.
S & F in repairs ,Fire hyderant stand post 80mm dia GI/MS flanged type 1.5 m height single outlet confirming to IS 908 complete all as specified and directed by eingneer-in-charge.
Supply ,fixing ,testing & installation of CI sluice valve flanged of class PN 1.6 ISI marked with gun metal spindal , brass nuts and cast iron wheels jointiting material size 80 mm dia ,in repairs complete all as specified and directed by eingneer-in-charge.
Supply ,fixing & testing of Cast Iron Non Return Valve size 80 mm dia including taking down existing Cast Iron Non Return Valve , complete all as specified and directed by eingneer-in-charge.
S & F in repairs Fire brigade connection consisting of four way 63 mm dia instaneous complete all as specified and directed by eingneer-in-charge.
S & F in repairs CI foot valve 100 mm dia both side complete all as specified and directed by eingneer-in-charge.
S & F in repairs Sprinkle glass tube type complete all as specified and directed by eingneer-in-charge.
S & F in repairs Sprinkle glass tube upright type complete all as specified and directed by eingneer-in-charge.
Supply , fixing , testing and commissning of Fire alarm control panel compiling(FACP) per loop including taking down existing panel complete all as specified and directed by eingneer-in-charge.
Supply ,fixing , testing and commissning of Smoke detector addreseble type with base with self built intelligence as per IS 11360 including taking down existing detector, complete all as per specified and directed by eingneer-in-charge.
Supply ,fixing ,and commissning of Heat detector addreseble type with base with self built intelligence as per IS 11360 ,including taking down existing detector complete all as specified and directed by eingneer-in-charge.
Supply ,fixing , testing & commissioning of addressable manual call point/pill station resettable type with base including taking down existing manual call point/pill station complete all as specified and directed by eingneer-in-charge.
Supply ,fixing , testing & commissioning in repairs of control module with base complete all as specified and directed and directed by eingneer-in-charge.
Supply ,fixing , testing & commissioning in repairs of intellegent addressable fault / short circuit Isolator with base complete all as specified and directed by eingneer-in-charge.
Supply ,fixing & testing in repairs of remote Response Indicator complete all as specified and directed by eingneer-in-charge.
Supply & fixing in repairs , Isolators suitable for fire system requires as per site all as specified and directed by eingneer-in-charge.
Supply & fixing in repairs, Storb hooter with all fitiing complete all as specified and directed by eingneer-in-charge.
BS BUILDERS
shiv shanker enterprises
Continental Engineers and contractors
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .