| 1 | L-2₹2.3 L+₹51,829.89 (29.0%)Accepted-AOC ARA P O GANESHPUR DIST LATEHAR PIN 829202 | LATEHAR | JHARKHAND | 829202 | L-2 | Accepted-AOC As per Recommendation of TC and Approval of Competent Authority | |
| 2 | L-1₹1.8 LRejected-Finance | L-1 | Rejected-Finance As per Recommendation of TC and Approval of Competent Authority |
Tender Value
₹1.8 L
EMD Value
₹2,300
Closing Date
13 Jun 2022, 5:00 pmClosed
Staff Officer (EnM) M- S Area
Office Of the General Mannager M-S Area, Bachra 829201
Work of Power Re- arrangement and hightining of pole for crossing of weigh bridge no 12 Due to Low height cement pole also DG shifting with it s Earthing arrangement from Road side to JBVNL Transformer under Magadh OCP M-S Area
2022_CCL_245207_1
GM(M-S)/SO(EnM)/e-NIT/22-23/08
Open Tender
Electrical and Maintenance Works
Item Rate
4 days
Magadh OCP
Please Refer NIT
4 documents required · 4 mandatory
₹2,300
31 Jan 2023
30 May 2022
14 Jun 2022
30 May 2022
13 Jun 2022
30 May 2022
30 May 2022 - 6 Jun 2022
Amount
Erection of metallic pole of length above 10mtr and upto 12 mtr in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.
Erection of angle Iron/channel iron cross arm on wood/RCC/PCC/steel tubular or Rail pole for 4 wire system.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .for lighting purpose
Erection of angle Iron/channel iron cross arm on wood/RCC/PCC/steel tubular or Rail pole for 2 wire system.
Supplying and erection of 100 mm X 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required .
Supplying and erection of 100 mm X 110 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply of 6 SWG G.I wire
Erection of G.I wire no-6/8 SWG including binding etc.as required
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2x1.5
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying,installing,testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC Fuses, connections, earthing etc. 100 Amps
Total impact of GST for the purpose of CTC
M/S T K ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_253316.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .