| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹29.1 LAdmitted-Fee/PreQual/Technical/Finance | -17.80% | ₹29.1 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹32.7 L+₹3.5 L (12.1%)Admitted-Fee/PreQual/Technical/Finance | -7.84% | ₹32.7 L+₹3.5 L (12.1%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹34.5 L
EMD Value
₹70,900
Closing Date
19 Sept 2026, 2:00 pmClosed
Executive Engineer
Electrical Division No.II, HPPWD, U.S. Club, Shimla-01.
Replacement of burnt damaged main panel sub panel and armoured cable in APMC at Parala Tehsil District Shimla.
2026_PWD_142827_1
ED.II.TA.NIT.26-27-2580 dt. 05-09-2026
Open Tender
Electrical Works
Percentage
90 days
Parala Mandi
Please refer to tender documents. Eligibility criteria is mentioned at page No. 7-8, 9-10 of GCC. Documents mentioned in eligibility criteria must be uploaded to qualify the bid.
7 documents required · 7 mandatory
₹2,000
₹70,900
22 Sept 2026
10 Sept 2026
21 Sept 2026
10 Sept 2026
19 Sept 2026
10 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying installation testing & commissioning of Main L.T. Panel ACB 800 amps 440 volts with tinned copper busbar (TTA) IS- 61439 compliance 800A, 4P, 50kA, with Microprocessor Based Release having Inbuilt O/L, S/C & E/F Protections (Ics=100% Icu), Trip Contact floor mounted main LT Panel Enclosure cubicles designed verified assemblies completely as per IEC 61439 protection having from 3 B construction duly tested with 1K 10 shall be aestheic design dust damp & vermin proof shall be moudular extendable and shall have maintaince friendly construction shall have fully compartmentalized bolted construction shall be metal clad sheet steel enclosed cubicle floor mounting type suitable for indoor installation shall have structural steel frame work as per IEC 61439 part 1 & 2 shall have integral base frame with bottom cable entry having removable glands plates . the panel shall be made out of GI sheet steel & CRCA sheet steel .The CRCA steel parts shall be powder coated with RAL 7035 powder colour after proper tank chemical treatment Gasketing shall be done properly to prevent any ingress of dust & vermin etc protection for 1/2/3 phase submain as outgoing and including LED indicating lamp as reqd complete as per Techanical specification is given below in all respect. Make:-L.K ABB/Schneider, Siemens, Legrand, (TTA) IS- 61349 Compliance. | |||||
| 1.01 | Incomer | - | - | - | - |
| 1.02 | ACB 800A 4P 50KA TMR With O/L & S/C Protection-1Nos | - | - | - | - |
| 1.03 | Spreader Link ACB 800A 4P- 2 nos | - | - | - | - |
| 1.04 | RHOM Ext.- 1 Nos | - | - | - | - |
| 1.05 | SPD Type 1+2 3Phase- 1Nos | - | - | - | - |
| 1.06 | A.T.S. 800A 4P- 1Nos | - | - | - | - |
| 1.07 | Indication Lamps LED Type RYG- 4 Nos | - | - | - | - |
| 1.08 | Indication Lamps LED Type Blue- 2Nos | - | - | - | - |
| 1.09 | Control SP MCB 6A -6 Nos | - | - | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.57 MB
GCC.pdf
Tender Documents • 5.26 MB
BOQ_212142.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .