Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC ACCEPTANCE |
| 2 | L2₹1.4 Cr+₹76,135.70 (0.55%)Rejected-Finance | ₹1.4 Cr+₹76,135.70 (0.55%) | L2 | Rejected-Finance L2 |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
8 Mar 2025, 6:00 pmClosed
COL SAIKAT DE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO KAMAOV COMPLEX P 494 AT BSG GOA INS HANSA UNDER GE (NW) VASCO
2025_MES_695041_1
85920/E8
Open Tender
Civil Works - Buildings
Item Rate
270 days
CWE NAVY VASCO
AS PER TENDER DOC
9 documents required · 9 mandatory
₹1,000
Yes
GE (NW) VASCO
₹2.2 L
Yes
21 Mar 2025
27 Jan 2025
10 Mar 2025
27 Jan 2025
8 Mar 2025
17 Feb 2025
Amount
Chipping loose concrete and Exposing existing RCC columns,beams,slabs,lintels,pardi etc.including plaster beyond main reinforcement carefully by means of chisel and hammer or mechanically including necessary double scaffolding ,erecting horizonal platforms at working levels to collect the debris, proping with top and bottom runners as directed stacking the debris in the compound as directed and caring away the same outside the premises etc. complete.
RELIEVING STRUCTURAL MEMBERS Relieving structural members such as column,beam and slabs of their superposed loads partially or fully by provison of adjustable steel props, frames etc. including providing necessary timber runners,bracing , jacking up arrangement all complete to the satisfication of Engineer in charge(Removing and redoing of brickwork, if required ,shall be paid separately.
Chipping of existing loose,damaged concrete from RCC members of all affected RCC Columns,Beams, Slabs and Chajjas on External and internal facades etc beyond main r/f.(if requried in the opinion of the Consultant),carefully with chisel and hammer providing and applying ' Rusticide SS' Rust passivater or equivalent as specified in the Brand Names to existing r/f bars including wire brushing of reinforcement,cleaning washing of concrete etc complete as directed.Providing and applying two coats of rust preventor slurry made out of " Polyalk Fixoprime"or equivalent as specified in the Brand Names and cement in proportion 1:1:5 to existing r/f bars as directed complete.Providing and applying bonding coat of slurry made out of "Polyalk EP" or equivalent as specified in the Brand Names and cement in proportion 1:1 to concrete and e/f substrates complete as directed Providing and applying "Polyalk EP" or equivalent as specified in the Brand Names,Polymer modified cement mortar in Required proportion(1:5:15) to RCC members including hand packing,curing and making the surface rough for plastering.
FILLING AND REINSTATING OF SEPARATION CRACKS
FILLING AND REINSTATING OF SEPARATION CRACKS Opening the Separation cracks at the Juction of RCC and Masonry where ever directed and instructed into "V" Grooves 2" to 3" from the either side of the cracks by carefully marking the areas to be opened up using a cutting machine and skillfully Chiseling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete Substrata and masonry wall with water jet to the surfaces thus prepared to the entire satisfication of the Consultant as instructed and directed.
Moistening the cracks ,providing and applying primary/bonding coat of slurry made of "Polyalk EP" and cement(or equivalent as specified in the list of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed.Filling the cracks /Grooves by Providing and applying "Polyalk EP" Polymer modified cement mortar (or equivalent as specified in the list of Brand names) in Proportion of 1:5:15 (Polyalk EP: Cement:Graded sand/quart/sand ) on the prepared surfaces and finishing it in the level with the existing plaster including hand packing curing and making the surface similar to the external plastering using wooden floats/punch etc.complete as per specified and directed.
Drilling holes of required size upto 16mm Diameter and up to 50mm depth in concrete and cleaning the same as directed.
Providing and fixing 12mm diameter aluminium/PVC injection nipples and securing the same as diected & Providing and injecting cementitious grout using CEBEX-112 additive of 'Fosroc' at the rate of 225 grams per bag of cement and usng suitable mechanical gun/pump including mixing etc complete.
Providing & fixing epoxy dipped shear keys of 10mm dia and 4" to 6" length in columns before jacketing Micro concreting as per Consultants instructions and directions.
Providing,cutting,bending and fixing Additional Reinforcement in postion steel reinforcement of specified required sizes and shapes in the form or main rebars, stirrups & rings,distrubtion rebars tec.and tying them to shear connectors using GI Binding wire.The additional rebars should be coted with TWO coats including Anti Corrosive protective coating &dry sand to be sprinkles on second coat including tying with Annealed Binding wires,providing cover blocks of appropriate sizes etc complete as specified and instructed by the Consultants.
Providing and laying super fluid Microconcrete -Roffe crete repairs (or equivalent as specifed in the list of Brand names) in beam bottoms, columns,slab etc including mixing with 5mm to 10mm size aggregates waterproof ply wood/steel plate shuttering,pouring,temping,Consolidating,curing etc complete as per Manufacture's specification and Consultants instructions.The item shall be paid on actual consumption of Micro concrete.
Providing and laying in slabs,beams,pardi,RCC wall etc postion of RCC M-30 design mix grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying and the cost of centering,shuttering form work,finishing and excluding reinforcement,including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete,improve workability without imparing strength and durability as per direction of Engineer-in charge.The Mix design as per particular specifications shall be got approved by Enginner -in charge before execution of the item. The rate shall include cost of all specified materials and operations at all levels and heights,including the cost of centering ,shuttering and form work excluding reinforcement which shall be paid under relevent item (Note:- Cement content considered in this item @ 300 kg/cum as per IS 456 table showing minimum cement content.No extra will be paid nor any amount will recovered on account of variation of cement in mix design as per specifications for controlled
Post completion NDT report based on the item catered in Sl No 1 to 10 of BOQ or otherwise merntioned , a certificate has to be furnished alongwith detailed post NDT report certifying structural strengthening carried out and repair work carried out as desired and technically acceptable report has to be vetted and certified by IIT/NIT as approved by the CWE and detailed structural repair of specific strength to be provided as required by GE / Engineer in Charge Note: Following has to be catered while quoting the rates for item sl no 1 to 10:- (a) After complete execution of these items post NDT of all structural members catered has to be done by the contractor. (b) While execution it is to be kept in mind that desired strength of the structural members should be maintained. (c) Complete report should be submitted for all the structural members catered.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
S&F PVC Rain Water Pipe 150 mm dia including all fittings, head , shoes, branches all as specified fixed in wall including joint with PVC adhesive
S&F for PVC plain bends 150 mm bore complete all as specified and as directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed in floors/ walls.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
S & F in repairs 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam,tee, angle, channel or flat sections) confrming to Fe 410-W including cleats,distance pieces etc
S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam,tee, angle, channel or flat sections) confrming to Fe 410-W including cleats,distance pieces etc
Demolition of reinforced Cement Concrete in any description and in any position not specifically provided for (roofs, floors(other than ground floors), beams, staircases, landing, chajjas and similar suspended work) complete all as specified and as directed.
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with ANF (Board) edge tiles with Armstrong 24mm exposed grid. The tiles should have Humidity Resistance (RH) of 90%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 34%.The tile shall be laid on Armstrong Prelude38 with 24 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15.34Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. The Tile & Grid system used together should carry a 10 year warranty all as directed by Engineer in Charge.
Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) with all aluminium hardware as specified.
Taking down chowkat or frames exc 1.5 sqm but n. exc 4 sqm each (w/o taking ofF shutters from the frame ) complete with all aluminium hardware as specified.and directed.
M&L complete removal of existing treatment and Preparation of Old wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer.
S&F powder coated (minimum thickness of powder coated 50mm micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete architectural drwaings and the direction of Engr-in-Charge. NOTE : (a) Item shall be paid as per actual weight of aluminium section. (b) The rate shall be inclusive of the locking arrangments including required builder harware complete packing with silicon gel around contacting surface of aluminium work including matching the existing surface area
S&F powder coated aluminium Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters (openable/sliding) for doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tabular section /appropriate Z section and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dis and size including necesarry filling up the gaps at junctions i.e at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium section shall be smooth, rust free staringht ,mitered and jointed mechanically wherever required incluidng cleat angle aluminium snap beading for glazing /panelling, CP brass/stainless steel screw all complete as per architectectural drawings and the direction of Engineer-in-Charge.
NOTE : (a) Glazing shall be measured seperately (b) Item shall be paid as per actual weight of alumimium secion (c) The rate quoated shall be inclusive of neoprene beading glazing clips, screw etc as required which shall not be (d) The rates shall be inclusive of the locking arrangments including required builder hardware complete packing with silicon gel around contacting surafce of aluminium work and including matching the existing surface area
S&F Powder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including standed aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick all as per manufacturer's instructions complete all as specified and directed
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam colour PVC sheet on back face,including 20 mm thick PVC lining around all 4 edges of shutter, supplying & fixing in frame at site as per specification & drawing all as specified and directed.
S&F Factory made 100% solid wood plastic(WPC) Decorative Door Frame,single rebate of size 75mm x 50mm made from wood plastic composite(single extruded process) material with density 780 Kg/Cum complete all as specified and directed.
M&L 12 mm thick Prelaminated particle board, exterior grade, prelaminated both sides with decorative choice lamination & other side balancing white lamination, fixed with screws to timber/aluminium frame work in cupboard shutters, partitions, shelves, pelmet boxes or narrow widths and similar work.
S & F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section
S & F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section
S&F butt hinges medium weight stainless steel 100 mm size
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised.
Aluminium alloy, anodised, sliding door bolt 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
Aluminium alloy, anodised, sliding door bolt 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed in repairs
S & F in repairs of floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of vover plate 140 mm
S & F Aluminium alloy wire mesh, 0.45 mm dia of wire and average width of aperture 1.40 mm and fixed with stainless wire staples in repairs complete all as specified.
S & F in repair Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads.
S&F 4mm thick sheetglass ordinary quality exceeding 0.5 sqm each pane complete all as specified.
S&F aluminium (die cast) body door closer hydraulically regulated designation No 3, universal type suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed in repairs
Dismantling/Taking out existing hessain base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled as directed by Engr-in -charge.
Providing 10mm thick plaster in CM (1:4) mixed with 3% integral water proofing compound over roof top surface incl filling all cracks by forming groove of 5mm x 5mm finished to even & smooth w/o using extra cement. Note :- Integral water proofing compound will be measured and paid seperately
M&L for applying evenly & priming with oil bound bituminius primer at 0.4Ltr per sqm for water proofing treatment complete all as specified.
M&L for APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified.
Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified.
M&L 25 mm thick Cement concrete type B1, 1:2:4 (using 20 mm graded granite stone aggregate) in roof for maintaining proper slope to avoid waterlogging all as specified and directed.
M&L 100 mm thick Cement concrete type B2, 1:2:4 (using 40 mm graded granite stone aggregate) in flooring/ hard standing complete all as specified.
M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in subbase,plinth protections, finished even and smooth w/o using extra cement complete all as specified.
Dismantling of stone slabs and tiles of any description or thickness in floors/dado etc laid bedded and pointed in any mortar complete all as specified.
M&L 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite complete all as specified and directed.
M&L Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified.
Sand filling under floors or in foundations including watering and consolidation complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
M&L Coloured Non skid ceramic tiles light/dark shade 7 to 8 mm thick (Square/rectangular) area of each tile exeeding 0.18 sqm but not exe 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over & incl 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
All as per item No. 59 but as in skirting/dado but over 10 mm thick rendering over CM 1:4 complete all as specified.
M&L Virified Ceramic tiles light/dark shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors laid over & incl 15 mm thick screed in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of floor complete as directed by Engineer-in-Charge.
All as per item No. 61 but as in skirting/dado but over 10 mm thick rendering over CM 1:4 complete all as specified.
M & L Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over & incl 15 mm thick screed bed in CM 1:4 complete all as specified and as directed.
M&L coloured Glazed ceramic tiles in vertical surfaces 300 x 200 x7 mm/ 450 x 300 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & incl.10 mm thick rendering in CM 1:4.complete all as specified and as directed.
M&L 2 mm thick homogenous PVC tiles/ sheets, laminated & coloured, marbled mosaic or mottled finish, laid with ap proved rubber based adhesive in floors complete all as specified.
Dismantaling water tanks and removing to store exc 500 but n. exc 1000 ltrs complete all as specified.
Dismentaling water tanks and removing to store exc 250 and n.exc 500 ltrs complete all as specified.
S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position inc 20mm bore PVC float valve all as specified and directedin SSR Pt I complete all as specified.
S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position inc 20mm bore PVC float valve all as specified and directedin SSR Pt I complete all as specified.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia complete all as specified.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 25 mm dia complete all as specified.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 20 mm complete all as specified.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 25 mm complete all as specified.
S&F in repairs fancy type chromium plated 15 mm bore stop valve/angle cock cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repair Wash basins 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe(32 mm) but including waste fittings complete all as specified.
S&F PVC valveless, syphonic action type flushing cistern, low level , white, with inlet ball valve, float and handle including brackets 10 litres capacity complete all as specified.
S&F in repairs Vitreous China wash down water closet pan (Pedestal pattern) white complete incl seat and cover, flush pipe incl all joints complete all as specified.
S&F in repair 15 mm bore chromium plated two way bib cock with wall flange in hindware /jaquar or equivalent.
S&F for hand shower (Health faucet) dia 8mm 1 mtr long flexible tube and wall hook Cat No ALD 573 of Jaquar or equivalent in Parko/Kohler complete all as specified.
S&F in repairs Soap dish, of material brass with glossy finish,Cat No. BA-45 of Prayag or equivalent complete all as specified.
S&F in repairs Aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges .
S&F in repairs Vitreous China half stall urinals, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, magnum urinal spreader, pointing around urinal back in cement; flush pipe, grating and Union for discharge pipe.
S & F in repairs chromium plated 15 mm bore Push taps cast copper alloy high pressure screwed for iron/CPVC pipe for urinal complete all as specified and directed.
PVC Connections 15mm size with PTMT nuts of length 600 mm complete all as specified.
S&F in PVC (SWR) floor trap 75 mm, plain with CP grating including joining with solvent cement complete all as specified.
Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms) 32mm bore complete all as specified.
S&F in repair 15 mm bore, chromium plated bib taps cast copper alloy with crutch or butterfly handle screwed down for iron/PVC pipe complete all as specified & directed.
S&F in repair 15 mm dia fancy type pillar taps, long neck, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed as in repair complete all as specified.
S&F in repair Brass Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union alongwith arm 225mm and flange complete all as specified.
S&F grating round 125 mm size of PTMT (min weight 40 grms) complete all as specified.
S & F Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified.
Demolition of stone /boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified.
Pre - cast cement concrete masonry with Grade C-5.0, (20mm graded stone aggregate) with solid blocks wall built in cement mortar 1:6 complete all as specified.
Taking down cement plastering at any description on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed.
M&L rendering 5 mm thick in CM 1:3 in ceiling finished even and smooth (without using extra cement) complete all as specified.
M&L Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid seperately.
Supply only water proofing compound complete all as specified.
M&L rendering 15 mm thick in CM 1:6 on concrete solid block wall internal surface finished even and smooth without using extra cement complete all as specified.
M&L Preparing new plastered ceiling surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling complete all as specified.
M&L Preparing new plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall complete all as specified.
M&L complete removal of existing treatment and Preparing old plastered ceiling surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling complete all as specified.
M&L complete removal of existing treatment and Preparing old plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall complete all as specified.
M & L for preparation of new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm all as specified and as directed.
M & L for preparation by complete removal of existing treatment of painted walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm all as specified and as directed.
M&L for preparation of steel surface and applying one coat of red oxide zinc chrome primer and two coats of Epoxy anticorrosive paint over 10 cm width or girth complete all as specified.
S& F in repair Ball brass valve, high pressure, with polythene floa thorizontal plunger type, IS-1703-2000 marked screwed to iron pipe or brass ferrule of size 25 mm bore complete all as specified and as directed.
M&L for providing and fixing stainless steel (Grade 316) railing made of hollow tubes , channels , plates, chain etc incl welding, grinding, buffing , polishing, and making curvature(wherever required) and fitting the same with necessary SS nuts and bolts complete , incl fixing the railing with necessary accessories and SS - fasteners, SS bolts ,etc of required size on the top of floor or the side of waste slab with suitable arrangement all as designed and as directed by engineer in charge
S&F 12 mm thick toughened glass as in SS railing windows, partitions automatic doors and similar works incl cutting to shape drilling holes required all as specified and as directed by engineer in charge
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets complete all as specified.
S/F 18 mm thick single side prelaminated woodgrain solid PVC sheet suitablely fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work with all fittings and locking arrangements as per direction and specifications.
Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of 100m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination ® 21056 Add for every complete all as specified.
Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit concealed in wall of as required size (not less than 20 mm in dia) ISI marked medium grade with all accessories of same grade fixed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing switch, socket, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per item No 114 here in before, but for one fan/exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per item No 114 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed
Supply and fix rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks including cutting and chisling ,pinning in ,making good as existing with PCC Complete as directed by engr-in-charge.
M & L for surface point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium duty, with all accessories of same grade, fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
M & L for sub main wiring with four runs of single core 10 Sqmm FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non metallic rigid PVC conduit medium grade of as required size (not less than 20 mm in width) with all accessories such as Tees, elbows, junction boxes etc, as required fixed concealed in wall along with Two run of 10 Sqmm single core FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Four runs of cable, Two run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit)
All as per item No 120 here in before, but two run of single core 6 sqmm and one run of 6 sqmm cables as earth continuity conductor all as directed.
All as per item No 120 here in before, but two run of single core 4 sqmm and one run of 4.0 sqmm cables as earth continuity conductor all as directed.
S & F in repairs modular Switch single pole one way 6 A, 240 V complete all as specified and as directed
S & F in repairs modular Switch single pole one way 16 A, 240 V complete all as specified and as directed
S & F in repairs Modular Socket outlet 2 in 1, 6 Amp , 240 volts, complete all as specified and as directed
S & F in repairs Modular Socket outlet 5A/16A, 5 in 1, 3 pin, flush type universal, 240 voltscomplete all as specified and as directed
Supply and fix Telephone socket with PVC box complete all as specified and directed
Supply and fix non metallic rigid PVC junction boxes 1 to 4 way 32 mm dia, concealed in wall/ceilling for TV/Telephone cable all as specified and directed
S & F in repairs Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 volts complete all as specified and as directed
S & F in repairs Modular Fan step regulator, 120W - 2 module all as directed.
Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed.
S & F in repairs 20/25 Amps motor starter switch with overload protection , ideal & safe for air conditioners , cooler , water pumps , refrigerators mixer , and all type of appliances Computers complete all as specified and directed by Engr-in-Charge.
S & F in repairs 20/25 Amp Power unit combo MCB Protected socket with top , ideal & safe for air conditioners , cooler , water pumps , refrigerators mixer , and all type of appliances Computers complete all as specified and directed by Engr-in-Charge.
S & F in repairs MCCB DB VTPN (MCCB +8 way O/G) double door, vertical type icluding provn for MCCB of upto 200/250 amps 36 KA breaking capacity 4 pole without MCB complete all as specified and as directed
Supply and fix in repairs MCCB of 200 A breaking capacity 36 KA , 4 pole thermal megnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB's complete all as specified and as directed.
S&F in repairs MCB DB TPN 6 way DB 415 V with 200 A rated bus bar double door type complete all as specified and as directed.
S & F in repairs MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed .
Taking down ceiling fan1200/1400 mm sweep of any make from its existing position after disconnecting of electric connection for carrying out repairs including servicing, overhauling, greasing etc after cleaning the body internally and externally with cleaning agent including renewal of minor spare parts such as split pins, cater pins, coupling bolt, capacitor holder, terminal adoptor, screws, nuts and washers etc and replacement of spare parts/accessories such as ball bearings, gun metal bushes, capacitor, canopy top and bottom, shackle clip assembly, rewinding of fan motor, painting and including hanging/ fixing back in existing location and making cable connections and testing for its satisfactory performance complete all as specified and directed.(Note: - Spate parts will be measured and paid seperately)
Supply and fix in repairs fan capacitor 2.5 / 3.15 mfd, 240 volts, 50Hz complete all as specified and directed.
Supply and fix in repairs only ball bearing suitable for ceiling fan/exhaust fan/air circulator/pedestal fan any type. (Make: M/S SKF/NBC) all as directed.
Supply and fix in repairs shackle clip assembly with rubber bush reel and nuts, bolts and washers suitable for ceiling fan of any sweep complete all as specified and directed.
Supply and fix in repairs PVC canopy top and bottom with tighten screw suitable for ceiling fan of any sweepcomplete all as specified and directed by engr-in-charge.
Supply and fix in repairs split pin as per sample suitable for ceiling fan all as directed by engr-in-charge
Supply and fix in repairs MS nut bolt with split pin as per sample and as directed by Engr-in-charge
Supply and fix in repairs down rod made of MS pipe medium grade 15mm dia of 300/450/600 mm long duly drilled holes both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to of down rod with two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Supply and fix copper conductor cable 3 core; 0.75 sqmm, PVC insulated, sheathed, flexible, multistranded,1100 volts grade for making connection to ceiling fan from ceiling rose complete all as specified and directed
Material and labour for painting to ceiling fan of any sweep complete body, blades and down rod with two coat of synthetic enamel paint similar to match with existing colour after preparation of surfaces by using electric spray machine including marking of MES Number with black paint complete all as specified and directed directed.
Material and labour for rewinding of ceiling fan motor of existing size of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns as existing,including cleaning the motor properly and applying varnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from ceiling fan motor complete all as specified and directed.
M &L for removing old unserviceable motor assembly from exhaust fan and fixing new exhaust fan motor assembly suitable of size 300/380 mm sweep and including nuts, washers, and testing complete all as specified and directed.
M &L for removing old unserviceable blade assembly from exhaust fan and fixing new exhaust fan blade assembly suitable of size 300/380 mm sweep and including locking nuts and testing complete all as specified and directed.
S &F in repairs louver of metallic frame with wings including nuts bolts and washers with size suitable as per item no 152 as directed by engr-in-charge.
S & F in repairs Energy efficient surface Mounted LED Luminaire 18 watts 4' long, with alluminium extruded body complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr all as directed.
S & F in repairs Energy efficient surface Mounted LED Luminaire 10 watts 2' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 mtr all as directed.
S & F in replacement of evironmental friendly, ultra modern, energy saving, LED panel square of size 2'X2' with unique slimmest recess cum surface panel, solution to provide variable cutout size for installation in recess of 36 watt and including removing old U/S,complete all as specified and directed.
Supply and fix in repairs Building Security LED fitting 90 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired and making cable connection all as specified and directed.
Supply and fix in repairs GI bracket pipe of size 32/40 mm dia medium grade of 1.0 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket pipe shall be fixed on wall/pole surfaces by providing suitable MS flat iron 32x6 mm clamps 2 nos of 25 cm long duly to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts,bolts & washers and removing of old unserviceable item complete all as specified and directed
Disconnecting all existing electric connection and taking down old existing cable fixed on old detoriated/rusted cable tray along with cable tray complete as directed by engr-in-charge. Note:- Each run of cable will be measured separately
S & F in rpeairs perforated cable tray made out of GI Sheet of 14 SWG thickness including cable tray cover and as per required depth hot dipped in various width sizes including accessories like couplar plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, complete all as specified and as directed.
Re-laying of serviceable cable of any core on new installed cable tray including suitable cable fixing arrangement ,necessary connection as existing of any size of any core complete all as specified and directed by engr-in-charge. Note:- Each run of cable will be measured separately
Dismantling the existing GI Central AC plant grill, duct with insulation by dismantling MS duct flange, unscrewing of nut, bolt and washer, removing the insulation material and keep the same in the safe custody and refix the same into the existing position by re-assembling incl replacement of new duct insulations, new fixing arrangement and re-fixing the grills complete after repair work complete all as specified and as directed.
Taking out serviceable/unserviceable Split (indoor / outdoor) / window AC from existing position carefully and re-fixing after renovation of building complete all as specified and directed by engr-in-charge.
M & L for Servicing of Split AC (indoor /outdoor) /Window AC making it in serviceable condition including Gas charging as per existing refrigerant gas and stand and necessary parts for split AC and window AC.
Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dence soil getting out and levelling of bottom surface to required level all as specified.
Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/disintegrated rock getting out and levelling of bottom surface to required level all as specified.
Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish to match the original finish all as all as directed by Engr-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick all as specified.
Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point.all as specified.
Supply and lay Double walled corrugated pipe (DWC ), heavy duty 110/95 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
Taking down old unserviceable LT UG cable from any description (trenches, walls,ceilings., etc) from various locations, Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 300 Sq mm, 4 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified.
Ditto all as per item No 171 here in before but of size 31/2 core 150 sqmm
Note for item No 171 to 172 :- 1. Excavation, Concrete cable protection cover, pipe, PCC work for road crossing / hard standing and Sand for cushioning will be measured and paid separately. 2. Cost of glands,aluminium cable lugs (eye lid/barrel / bottle neck type/ring type or any shape), new nut, bolt and washers of required size / description are deemed to include in this rate.
Supply and laying in repairs in trenches GI tubing light grade 100mm dia for road crossing/cable protection complete as required all as directed.
M & L for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials.
S & F in repairs HT / LT MS cable route indicator with two Nos of nut, bolt and washers and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the ground incl necessary earth work complete all as directed.
S & F in repairs LT Control panel board CPRI Approved, outdoor type,front openable door,floor mounted with one incomming suitable for MCCB of 630 Amps , alluminium busbar compartment and necessary outgoing compartment as per schedule,Provision of Main incoming MCCB switch of 400 Amps, and each out going feeders connected to busbar,dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 phase and neutral, 415 volts 50 Hz, AC supply,alluminium bus bar of 800 Amp rating for 3 phase and neutral 4 wire system duly insulated incl necessary connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at one earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour. Provision of connected incoming and out going items and accessories are comprising as below:-
Incoming :-
a) MCCB 4 Pole,630Amp 415V - 01 No
e) Indicator Lamps (LED type) showing R,Y, B phase - 01 set.
g) Angle iron base frame as reqd size as per above panel, total leg height 900 mm and grouting in side PCC 150 mm legs and made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.
h) M & L for necessary grouting as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job
Outgoing :-
a) MCCB 4 Pole,320 Amp 415V - 01 No
b) MCCB 4 Pole,100 Amp 415V - 06 No
c) MCB 4 Pole, 63 Amps 415 Volt -06 Nos
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
S & F in repair Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15 cm size all as directed.
M/s. R.S. LAWANDE (BID ID -3247724)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .