Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.2 LAccepted-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹78.6 L+₹2.5 L (3.26%)Rejected-Finance 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹81.9 L+₹5.8 L (7.56%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹81.9 L+₹5.8 L (7.60%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹92.7 L+₹16.5 L (21.7%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L5 | Rejected-Finance Not lowest bidder |
| Sl No | Description | Qty | Unit | Flint India L1 | Electromech Engineers L5 | Leo Network power systems L6 | M/S Kumar Contractors L7 | classic contriction co. L3 | UNIVERSAL ENGG CO L4 | Roy and Sons Infrastructures L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out /disconnecting of existing transformer of various capacites and deposited to E/M Yard from site by means of using suitable T&P all as directed by Engr-in-Charge. | 7 | Each Job | 8,000 ₹56,000 | 30,100 ₹2,10,700 | 2,500 ₹17,500 | 1,000 ₹7,000 Lowest | 8,000 ₹56,000 | 7,000 ₹49,000 | 8,000 ₹56,000 |
| 2.00 | Supply, installation, testing and commissioning of step down transformer out door type suitable for plinth mounting complete with standard accessories/fittings suitable for HT 11KV 3 Phase and LT 433 volts 3 phase 4 wire , Dyn-11, copper wound, with off load tap changer having voltage variation of ±7.5% in step of 2.5 % continuous rating of capacity 200 KVA with temperature rise shall not exceed 45° C for transformer winding and 40° C for top oil complete conforming to IS 1180 (Part 1) : 2014 Energy Efficiency Level - 3 for transformer including necessary suitable suze PCC plateform and comrrising of following fittings :-
(a) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing.
(b) Lifting lugs/hooks .
(c) Rating and terminal marking plate.
(d) Silica gel breather .
(e) Drain - cum - sampling valve (3/4)" nominal thread with plug
(f)Thermometer pocket with dial type thermometer.
(g) Oil filling inlet pipe with plug.
(h) Conservator with oil level gauge.
(j) First fill of oil up to appropriate level as recommended by manufacturer with fresh new oil.
(k) Type of connection arrangement : MS cable termination box on LT side and open bushing on HT side.
NOTE :- Plinth stone masonry platform as per manufacturer recommendations complete with standard fittings conforming to IS-1180 energy efficient and with ECBC Closset or latest IS complete all as specified and as directed. (Note:-Stone masonary platform will be measured and paid separately) | 1 | Each | 8,03,000 ₹8,03,000 | 7,86,000 ₹7,86,000 Lowest | 9,46,842 ₹9,46,842 | 23,00,000 ₹23,00,000 | 8,80,000 ₹8,80,000 | 8,82,000 ₹8,82,000 | 8,00,000 ₹8,00,000 |
| 3.00 | Supply, installation, testing and commissioning of step down transformer out door type suitable for plinth mounting complete with standard accessories/fittings suitable for HT 11KV 3 Phase and LT 433 volts 3 phase 4 wire , Dyn-11, copper wound, with off load tap changer having voltage variation of ±7.5% in step of 2.5 % continuous rating of capacity 250 KVA with temperature rise shall not exceed 45° C for transformer winding and 40° C for top oil complete conforming to IS 1180 (Part 1) : 2014 Energy Efficiency Level - 3 for transformer including necessary suitable suze PCC plateform and comrrising of following fittings :-
(a) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing.
(b) Lifting lugs/hooks .
(c) Rating and terminal marking plate.
(d) Silica gel breather .
(e) Drain - cum - sampling valve (3/4)" nominal thread with plug
(f)Thermometer pocket with dial type thermometer.
(g) Oil filling inlet pipe with plug.
(h) Conservator with oil level gauge.
(j) First fill of oil up to appropriate level as recommended by manufacturer with fresh new oil.
(k) Type of connection arrangement : MS cable termination box on LT side and open bushing on HT side.
NOTE :- Plinth stone masonry platform as per manufacturer recommendations complete with standard fittings conforming to IS-1180 energy efficient and with ECBC Closset or latest IS complete all as specified and as directed. (Note:-Stone masonary platform will be measured and paid separately) | 3 | Each | 9,56,000 ₹28,68,000 | 10,00,000 ₹30,00,000 | 10,75,796 ₹32,27,388 | 23,57,000 ₹70,71,000 | 9,80,000 ₹29,40,000 | 9,78,500 ₹29,35,500 | 8,50,000 ₹25,50,000 Lowest |
| 4.00 | Supply, installation, testing and commissioning of step down transformer out door type suitable for plinth mounting complete with standard accessories/fittings suitable for HT 11KV 3 Phase and LT 433 volts 3 phase 4 wire , Dyn-11, copper wound, with off load tap changer having voltage variation of ±7.5% in step of 2.5 % continuous rating of capacity 315 KVA with temperature rise shall not exceed 45° C for transformer winding and 40° C for top oil complete conforming to IS 1180 (Part 1) : 2014 Energy Efficiency Level - 3 for transformer including necessary suitable suze PCC plateform and comrrising of following fittings :-
(a) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing.
(b) Lifting lugs/hooks .
(c) Rating and terminal marking plate.
(d) Silica gel breather .
(e) Drain - cum - sampling valve (3/4)" nominal thread with plug
(f)Thermometer pocket with dial type thermometer.
(g) Oil filling inlet pipe with plug.
(h) Conservator with oil level gauge.
(j) First fill of oil up to appropriate level as recommended by manufacturer with fresh new oil.
(k) Type of connection arrangement : MS cable termination box on LT side and open bushing on HT side.
NOTE :- Plinth stone masonry platform as per manufacturer recommendations complete with standard fittings conforming to IS-1180 energy efficient and with ECBC Closset or latest IS complete all as specified and as directed. (Note:-Stone masonary platform will be measured and paid separately) | 1 | Each | 9,95,000 ₹9,95,000 Lowest | 12,70,000 ₹12,70,000 | 14,50,824 ₹14,50,824 | 25,64,000 ₹25,64,000 | 10,99,000 ₹10,99,000 | 11,05,000 ₹11,05,000 | 11,20,000 ₹11,20,000 |
| 5.00 | Supply, installation, testing and commissioning of step down transformer out door type suitable for plinth mounting complete with standard accessories/fittings suitable for HT 11KV 3 Phase and LT 433 volts 3 phase 4 wire , Dyn-11, copper wound, with off load tap changer having voltage variation of ±7.5% in step of 2.5 % continuous rating of capacity 400 KVA with temperature rise shall not exceed 45° C for transformer winding and 40° C for top oil complete conforming to IS 1180 (Part 1) : 2014 Energy Efficiency Level - 3 for transformer including necessary suitable suze PCC plateform and comrrising of following fittings :-
(a) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing.
(b) Lifting lugs/hooks .
(c) Rating and terminal marking plate.
(d) Silica gel breather .
(e) Drain - cum - sampling valve (3/4)" nominal thread with plug
(f)Thermometer pocket with dial type thermometer.
(g) Oil filling inlet pipe with plug.
(h) Conservator with oil level gauge.
(j) First fill of oil up to appropriate level as recommended by manufacturer with fresh new oil.
(k) Type of connection arrangement : MS cable termination box on LT side and open bushing on HT side.
NOTE :- Plinth stone masonry platform as per manufacturer recommendations complete with standard fittings conforming to IS-1180 energy efficient and with ECBC Closset or latest IS complete all as specified and as directed. (Note:-Stone masonary platform will be measured and paid separately) | 2 | Each | 10,71,000 ₹21,42,000 Lowest | 15,93,998 ₹31,87,996 | 16,12,474 ₹32,24,948 | 29,27,000 ₹58,54,000 | 11,95,000 ₹23,90,000 | 11,96,000 ₹23,92,000 | 12,85,000 ₹25,70,000 |
| 6.00 | Supply, laying, testing & commissioning in replacement of XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, PVC inner sheath, galvanized steel strip armoured and overall PVC sheathed electric power cables(heavy duty) with stranded aluminum conductor of cross sectional area 95 sqmm, 3 core, 11000 volts grade(Earthed) cable confirming to IS 7098 complete all as specified and directed. | 300 | RM | 1,255 ₹3,76,500 | 1,420 ₹4,26,000 | 981 ₹2,94,300 | 900 ₹2,70,000 Lowest | 1,159 ₹3,47,700 | 1,150 ₹3,45,000 | 1,070 ₹3,21,000 |
| 7.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard / dense soil for laying of cables/ for erection of poles/ for stay assembly etc complete all as specified and directed by Engineer-in-Charge. | 97 | Cum | 160 ₹15,520 | 300 ₹29,100 | 250 ₹24,250 | 100 ₹9,700 Lowest | 150 ₹14,550 | 160 ₹15,520 | 300 ₹29,100 |
| 8.00 | Supply and spread M-sand in trenches for cushioning of cable / in the yard of outdoor substations complete all as specified and directed by Engineer-in-Charge. (Note: Punned down thickness only shall be measured for the purpose of payment) | 53 | Cum | 800 ₹42,400 | 800 ₹42,400 | 900 ₹47,700 | 500 ₹26,500 Lowest | 850 ₹45,050 | 810 ₹42,930 | 1,000 ₹53,000 |
| 9.00 | Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer-in-Charge. | 67 | Cum | 60 ₹4,020 | 50 ₹3,350 Lowest | 150 ₹10,050 | 50 ₹3,350 Lowest | 50 ₹3,350 Lowest | 60 ₹4,020 | 60 ₹4,020 |
| 10.00 | Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge. | 30 | Cum | 60 ₹1,800 | 50 ₹1,500 | 150 ₹4,500 | 50 ₹1,500 | 120 ₹3,600 | 150 ₹4,500 | 40 ₹1,200 Lowest |
Tender Value
₹96 L
EMD Value
₹1.7 L
Closing Date
16 Jan 2026, 6:00 pmClosed
SHRI ANIL KUMAR, IDSE, SE, CWE
HQ CWE JHANSI
SPL REPAIR OF TRANSFORMERS OF VARIOUS CAPACITIES AT JHANSI CANTT
2025_MES_744977_1
CWE/JHA/J/TOKEN/88 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JHANSI
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
GE JHANSI
₹1.7 L
Yes
2 Feb 2026
17 Dec 2025
19 Jan 2026
17 Dec 2025
16 Jan 2026
8 Jan 2026
Supply, laying, testing & commissioning in replacement of XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, PVC inner sheath, galvanized steel strip armoured and overall PVC sheathed electric power cables(heavy duty) with stranded aluminum conductor of cross sectional area 95 sqmm, 3 core, 11000 volts grade(Earthed) cable confirming to IS 7098 complete all as specified and directed.
Supplying and laying in replacement of un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm for cable protection in trenches complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundations of pole/ stay assembly complete all as specified and directed by Engineer-in-Charge.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
Tenderdocuments88.pdf
Tender Documents • 1.38 MB
BOQ_834159.xls
BOQ • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .