Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st lowest₹16.3 LAccepted-AOC NASIBPUR SINGUR HOOGHLY | HOOGHLY | WEST BENGAL | 712101 | ₹16.3 L | 1st lowest | Accepted-AOC L1 |
| 2 | 2nd lowest₹16.4 LRejected-AOC | ₹16.4 L | 2nd lowest | Rejected-AOC L2 |
| 3 | 3rd lowest₹16.4 LRejected-AOC | ₹16.4 L | 3rd lowest | Rejected-AOC L3 |
Tender Value
₹16.4 L
EMD Value
₹32,742
Closing Date
28 Jan 2026, 1:00 pmClosed
SECRETARY, HOOGHLY ZILLA REGULATED MARKET COMMITTE
Administrative Building of Agricultural Marketing Department (2nd Floor), Rice Research Station, Chinsurah, Dist. Hooghly.
Supplying Installation and commissioning of Ten(10) nos. 9 Mtr Mini High Mast along with 6 nos 120 watt LED flood light arrangement at different market area under Hooghly Zilla Regulated Market Committee, Dist.-Hooghly.
2026_WBSMB_986226_1
40/HZRMC/2025-2026
Open Tender
Electrical Work/ Equipment
45 days
HOOGHLY
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,000
₹32,742
Yes
HOOGHLY ZILLA REGULATED MARKET COMMITTEE
7 Feb 2026
9 Jan 2026
30 Jan 2026
9 Jan 2026
28 Jan 2026
13 Jan 2026
13 Jan 2026
Supplying of swaged steel tubuler pole (IS 2713 Part II 1980) for the following designation and following dimesion. Designation 410 SP 30,overall length in mtr 9.0 approx W in Kg -113.suitable for 50 m/sec wind speed, with head frame, winch mounting bracket, luminaires carraige suitable to install 6 nos. luminaires in symmetrical arrangement [ Make- Utkarsh/Jindal/Bansal/Electro Pole][ 9M,125kg, 410-SP-29][I&W Schd.(E&M); I-5.3.E.1.14:P-108]
Erection of single Steel tubular pole of lenth as given below with /without sole plate& cap etc.in cc foundation (Proportion and dimension indicated below) having 600x600x150 mm thick cc (4:2:1) base block below the plate /pole with hard jhama metal including CC (6:3:1) muffing 0.30mts.dia and 0.30 mts. Above ground level including 3mm thick net cemented finish and GI earth bolt after making drilled holes etc.on pole and carriage the poleupto 1.6km from store to work site including filling up the excavated earth pit by shifted soil and ramming properly. UDMA(E&M); I-6a; Page-3
painting of steel tubular pole of lengths and no of coast of paint ,as given below with ready mixed paint/primer of approved make,and brand incl.preparation of surface by sand paper/emery paper,cleaning etc.for receiving fresh coat of paint.upto9 mtrs.long pole-i) 1st coat of aluminium paint over 1 coat of RO primer ii)2nd coat of aluminium paint (Blue&white)over 1st coat. Ref: PWD schedule 2014 ,H-2,7(A) [ udma; item-9 Page-4)
Supply of 120W LED Street light/flood light fittings New generation energy saving and environmental friendly long life versatile pressure diecast alluminium IP66 roadway luminaire with high power LED as light. CAT NO- HPPLLEDSL12060E or equivalent model of Havells/Philips/Crompton/Hpl [ Warranty 5 years] [ i&W Schd,E&M,I-5.3.F.11.0.4,page-112]
Laying of one No cable upto 35 sqmm in underground trench 460mm widex760mm average depth,with brick protection on top of the cable with 8(eight)nos bricks per meter,including filling the space between the brick and cable and also the trench with shifted soil,levelling up and restoring surface duly rammed Ref: PWD(ELECTRIAL) SCHEDULE 2017,F-2,1(A)
Supply of 2core 16 sqmm armoured Aluminium cable.(Finolex/Havells/Polycab/KEI)[ PWD-L4,K-10]
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting.200 x 150 x 100mm
Connecting the equipments to earth busbar including S&F GI (Hot Dip) wire of the size below on wall/flor with staples buried inside wall/floor as required and making connection to equipments with bolts,nuts,cable lugs etc as required and mending good damages Solid GI Wire no 6 SWG Ref:PWD(Electrical) Schedule 2017,G-2/5(a)(ii)
Connecting the equipments to earth busbar including S&F GI (Hot Dip) wire of the size below on wall/flor with staples buried inside wall/floor as required and making connection to equipments with bolts,nuts,cable lugs etc as required and mending good damages Solid GI Wire no 8 SWG Ref:PWD(Electrical) Schedule 2017,G-2/5(a)(iii)
Supplying and fixing compression type gland complete with brass gland,brass ring,rubber ring for dust and moisture proof entry of XLPE/PVC armoured cables as below.For 4 core up to 16 sqmm Ref:PWD (Electrical) schedule 2017,F-4/7(a)
Supplying & fixing earth busbar of galvanized (Hot Dip MS flat 25mmx6mm on wall having clearance of 6mm from wall incliding providing drilled holes on the busbar complete with GI bolts,nuts,washer spacing insulators etc as required.Ref: PWD (Electrical) Schedule 2017,G-2/4(a)
Finishing of the XLPE/PVC insulated armoured cable ends by crimping method incl supplying and fixing solderless socket(Dowels) type anticorrosive paste and jointing materials. 2 Core 16sq mm Ref: PWD (Electrical) Schedule2017,F-5/8(b)(iv)
Fixing outdoor type fluorescent/SV/MV light fitting on pole including bracket with 40mm x 10mm thick, MS clamp etc.and providing wiring with 2x1/1040 PVC insulated and sheathed wire (single core) from loop box at the base or pole to light fitting through pole & bracket (without control switch) including making connections & painting.Ref: PWD(Electrical) Schedule 2017,[Item-20c(a); Page c/3]
Supplying and fixing 240/415v MCB OF Breaking capacity 10 KA & C characteristics on din rail of existing DBs and necessary connection ------6-32 A SPN (standard) Ref: PWD (Electrical) Schedule 2017,D-7/8
Earthing with 50mm dia GI pipe 3.64mm thick x3.04mtrs long and 1x4SWG GI (Hot Dip) wire (4 mtrs long),13mm dia x80mm long GI bolts,double nuts,double washers incl.S&F 15mm dia GI pipw protection (1 mtr long) to be filled with Bitumen partly under the ground level and partly above ground level driven to an average depthof3.65mts below the ground level as below: by ISI-Medium GI pipe. Ref: PWD (Electrial) Schedule 2017,G-1/2(a)
Add CGST @ 9%
Add SGST @ 9%
Add Labour Cess @ 1%
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.15 MB
Tendernotice_2.pdf
PDF • 1.90 MB
BOQ_2407537.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid