Executive Engineer DWSS Moga
Room No. 313 3rd Floor Jhelum Chenab Complex DAC Moga
Prov. and laying of pipelines, installation of House connections and minor repairs in village Kokri Kalan, Block Moga-I, Distt. Moga
2020_WB_57966_1
PRWSSIP/2020/KokriKalan
Open Tender
Civil Works - Water Works
Item Rate
90 days
Village Kokri Kalan
Please refer Tender documents.
8 documents required · 8 mandatory
₹1
₹78,000
26 Mar 2021
28 Dec 2020
12 Jan 2021
28 Dec 2020
12 Jan 2021
28 Dec 2020
Amount
Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching powder solution/ Sodium Hypo Solution per hour under maximum delivery pressure upto 7 ka.cm 2 and suction lift not less than 1.5 m, as per DWSS standard specifications.( Zone-I And Zone-II)
Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects. (CSR item No. 28.90) (For Zone-II)
Repair of existing Pump Chamber
Existing Pump Chamber size 4.27x4.88M in Zone-III
Repair of existing Pump Chamber size 2.50 x 2.50 M (Zone-I )
Repair of existing Pump Chamber size 2.50 x 2.50 M ( Zone-II )
Repair of existing OHSR
Existing OHSR size 136 cum in Zone-I
Existing OHSR size 100 cum in Zone-II
Existing OHSR size 150 cum in Zone-III
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8. Zone- I & Zone- III =15+11=26 Nos
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7 & Analysis A-7 (Zone- I & Zone- III ) =24+8=32 Nos
Providing & fixing G.I. Barbed wire 2 ply (2 Strands of wire) conforming to IS: 278 fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8 Zone - I = 615 mtr Zone - II= 550 mtr Zone - III= 100 mtr 615+550+100= 1265
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3 ( Zone-I & Z0ne-II)
Repair of masonry gate pillar including plastering, pointing painting, and repair/piant of MS Steel Gate size 1.22mtr x 1.37 mtr etc. complete in all respects (For W/W site of Zone-II & Zone-III)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & inserting sheet, all carriage complete (with the approval of Engineer-in-charge) Class PN-1 as per ISI (CSR item 28.27) (A)
100 mm i/d Sluice Valve flanged
150 mm i/d Sluice Valve flanged
Repair of leakages in Existing pvc pipe lines including excavation, Bailing out water, D joint & re-filling, etc. complete in all respects
90 mm o/d pvc pipe
110 mm o/d pvc pipe
Deduct credit of old Sluice valves
Minor repair in existing household connection (by Providing & fixing washer (electric welded) in the 15mm union on existing water connection etc.), Where water connections were installed by consumers, but not as per DWSS specifications.
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE/GI pipe lines 15mm i/d=4.50 (2.5+2.0)mtr, including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 10mm i/d GM ferrule as per IS: 2692 and 3" i/d upvc clamp complete.
New Household Connections proposed On Existing / replaced Pipeline
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE/GI pipe lines 15mm i/d=4.50 (2.5+2.0)mtr, including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 10mm i/d GM ferrule as per IS: 2692 and 3" i/d upvc clamp complete.
New Household Connections on new pipe line
PVC Pipe Line 63mm o/d 6 kgf/sq.cm
PVC Pipe Line 90mm o/d 6 kgf/sq.cm
PVC Pipe Line 110 mm o/d 6 kgf/sq.cm
PVC Pipe Line 160mm o/d 6 kgf/sqcm
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
Dismantling of metallic road with bituminous coruse 50 to 75 mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respacts as per analysis A-26. NOTE:- Contractor shall quote rates only for dismantling mattle road and back filling with excavated earth, fully compacted. The restoration of the mattled road to its original condition will be done by the concerned department i.e. PWD (B&R)/PMB/Pnnchayti Raj.
Repair of Sign Board with paint and writing complete in all respect .
Connection of new pipe line with existing pipe lines including excavation, Bailing out water, D joint & re-filling, etc. complete in all respects.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .