Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹9.3 L+₹1.3 L (16.7%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹9.6 L+₹1.6 L (20.5%)Rejected-Finance | L3 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
30 Jan 2021, 6:00 pmClosed
GARRISON ENGINEER CENTRAL BANGALORE
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
MAINTENANCE REPAIRS OF DG SETS INCLUDING OTHER CONNECTED WORKS UNDER GE CENTRAL BANGALORE
2020_MES_338929_2
8913
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Bangalore
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER CENTRAL BANGALORE
₹20,000
Yes
11 Mar 2021
2 Jan 2021
1 Feb 2021
2 Jan 2021
30 Jan 2021
16 Jan 2021
2 Jan 2021 - 15 Jan 2021
Amount
Comprehensive maintenance/periodical maintenance/servicing and repair of standby Eco frendly/acoustic type DG set 100 KVA at 531 OR's Accn & Meerut Block of any make including 'A' check monthly & 'B' check 250 Hrs or 3 months which ever is earlier complete all as specified and as directed. Note :-1. Repair & maintenance should be carried out as per maintenance schedule prescribed in repair and maintenance manual thrugh qualified and experianced mechanic from the servicing centre who is conversant with the DG set and report should be submitted by the contractor.2. Rate quoted by the contractor includes the fixing charges for replacement of parts specified in relevant item here in after.3. The tenderer shall produce qualification and experiance cerificate of the mechanic to the Engineer in charge and approved personal only will be allowed to carried out the work. 'B' Check (i) Lubricant oil leaking(ii) Operation and repairs to lubricant oil leakage and cooling system leakage, rediator operation with coolant, hoses and connection, belt connection and tension. Fan hub drive pulley and water pump operation and cleaning of radiator cooling system.(iii) Leaking in air intake system, maintenance filter & air cleaner piping connection(iv) Fuel line and connection, fuel injection pump, cleaning of fuel tank for removing sediments(v) Leakage in exhaust system and exhaust restriction, drain out condensate trap, cleaning & maintenance of exhaust.(vi) Battery charging system & topping up electorlyte and maintenance of specific gravity.(vii) Cleaning of engine tightening of all nut, bolt, washer and unusual vibration.(viii) Checking to electric connection and smooth operation of generator control panel, greasing to all bearing and movable parts, measurements and recording winding insulation resistance cleaning up complete generator/alternator.
Supply only following parts of DG sets as specified under ser item No 1 i.e 100 KVA all as per recommendation of manufacturer and all as directed .Note:-Taking down & fixing charges will be included in SL No 1 . Supply only Fan belt set as per manufacture
Supply only Coupling main alternator
Supply only Fuel filter
Supply only Oil Filter
Fuel tank cleaning
Cleaning / Descaling of radiator internally and externally .
Servicing of self starter
All as per item No 1 above but capacity of DG Set 62.5 KVA at ASC Records(AT)
Supply only following parts of DG sets as specified under ser item No 9 i.e 62.5 KVA all as per recommendation of manufacturer and all as directed .Note:-Taking down & fixing charges will be included in SL No 9 . Supply only Fuel filter
Supply only Oil Filter
Fuel tank cleaning
Cleaning / Descaling of radiator internally and externally .
Servicing of self starter
Supply only Fan belt set as per manufacturer
All as per item No. 1 above but capacity of DG set 25/40/45 KVA at PH No-1, PH No-2 and ASC Records (AT)
Supply only following parts of DG set specified under ser item No 16 all as per recommendation of manufacturer & all as directed. NOTE:- Taking down & fixing charges will be included in Sl No 16. . Supply only Fuel filter
Supply only Oil Filter
Fuel tank cleaning
Cleaning / Descaling of radiator internally and externally .
Servicing of self starter
Supply only Fan belt set as per manufacturer
All as per item No. 1 above but capacity of DG set 30 KVA at Domlur, EME Wksp and Meerut Block.
Supply only following parts of DG set specified under ser item No.23 i.e 30 KVA all as per recommendation of manufacturer as directed .Note:- Taking down & fixing charges will be included in Sl No 23. Supply only Fuel filter
Supply only Oil Filter
Fuel tank cleaning
Cleaning / Descaling of radiator internally and externally .
Servicing of self starter
Supply only Fan belt set as per manufacture
All as per item No. 1 above but capacity of DG set 25 KVA at TB-IV(N) and PH No-1 College.
Supply only following parts of DG sets as specified under ser item No.30 i.e. 25 KVA all as per recommendation of manufacturer all as directed . NOTE:-Taking down & fixing charges will be included in SL item NO 30. Supply only Fuel filter
Supply only Oil Filter
Fuel tank cleaning
Cleaning / Descaling of radiator internally and externally .
Servicing of self starter
All as per item No. 1 above but capacity of DG set 15/20 KVA at Butchury, Baffle rang, ASC Records (South), Gill Stadium, Domlur Ph (100 MAP) and VOC/VNC .
Supply only following parts of DG set as specified under ser item No.36 all as per recommendation of manufacturer & all as directed. NOTE:-Taking down & fixing charges will be icluded in SL item No 36. Supply only Fuel filter
Supply only Oil Filter
Fuel tank cleaning
Cleaning / Descaling of radiator internally and externally .
Servicing of self starter
Supply only Fan belt set as per manufacturer
Dismantling DC dynamo/alternator of battery charging system 12/24V complete servicing including replacement of bushes, bearings, Carbon brushes, diodes any other minor parts required all as directed & fixing on engine testing/commissioning complete for any capacity of DG Set
Replacement of unserviceable contactor AC operated 4 pole 415 Volt suitable for DG Set 82.5 KVA to 100 KVA as per the existing type and model in the AMF panel complete all as specified and directed.
Replacement of unserviceable contactor AC operated 4 pole 415 Volt suitable for DG Set 40 KVA to 62.5 KVA as per the existing type and model in the AMF panel complete all as specified and directed.
Replacement of unserviceable contactor AC operated 4 pole 415 Volt suitable for DG Set upto 40 KVA as per the existing type and model in the AMF panel complete all as specified and directed.
Replacement of fuel pipe PVC metal braided all as per existing length fitted with benzo adopters to both sides with benzo bolts & washers.
Repair and Maintenance of existing canopy of eco friendly DG Set cleaning of internal & external parts, tightening of loose parts, replacing of unserviceable door locks and keys, replacing of damaged or burned inside sponge insulations complete all as directed.
Repair /replacement of PCB board of 15 to 100 KVA DG Set as per existing make and model complete all as specified as directed
Dismantling self starter of engine of DG set capacity 15 KVA upto 100 KVA & repairing the starter by replacing carbon brushes, bearings, solenoid coil, brush, brush holders complete rewinding,servicing refixing after repair, testing/commissioning complete all as directed by Engr-in-Charge.
M&L for repair battery charger of 12/24V 15Amps SCR controlled battery charger 12V /24V 15A with TRICKLE and BOOSTING facility, DC voltmeter, Ammeter, toggle switch etc in charge necessary connection from AC supply to Battery Charger and DC wiring to the battery with crocodile clip etc as required complete all as specified and as directed. Make : M/s. Naren or equivalent make as approved by Engineer in charge .
Replacement of Door hinges for DG Set canopy complete all as specified and directed.
Supply only engine oil 15W40 in sealed containers complete all as specified and diected.
Supply only coolent premixture in sealed containers complete all as specified and directed.
Supply only Fuel injector as per existing model of capacity 82 to 100 KVA DG Set.
Supply only Battery lead suitable for Battery 12 Volt 180AH alongwith copper lugs and colour of Red and Black for +ve and -ve with brass terminal.
Supply and fix digital voltmeter 0 to 500 volts including taking out unserviceable voltmeter complete all as specified and as directed. Make-MECO/L&T/IMP/SALZER
Supply and fix digital ampermeter 0 to 600 Amps including taking out unserviceable ampermeter complete all as specified and as directed. MECO / L&T/ IMP / SALZER
Supply and fixing in replacement of battery 12 Volts, upto 100 Ah as per the site requirement for DG Sets all as specified and directed. Make: Exide or equivelent as approved by GE.
M&L for repair to DG Set radiator of capacity 25 KVA to 45 KVA, cleaning,decaning,brazing, removing from Engine and refixing after testing complete all as directed.
M&L for repair DG Set radiator of capacity 62.5 KVA to 100 KVA, cleaning,decaning,brazing, removing from Engine and refixing after testing complete all as directed.
devan enterprises
M/S Bhagyawanticonstruction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .