| 1 | L1₹27.8 LAccepted-AOC NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | ₹27.8 L Quoted ₹29.4 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹30.7 LRejected-Finance HOUSE NO 97 MOHALLA AFGHANA GALI KRISHAN DWARA JAMMU | JAMMU | JAMMU | JAMMU AND KASHMIR | ₹30.7 L | L2 | Rejected-Finance Other than lowest bidder. |
| 3 | L3₹36.1 LRejected-Finance R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | ₹36.1 L | L3 | Rejected-Finance Other than lowest bidder. |
| 4 | L4₹38.0 LRejected-Finance 195 BALLABHBARI GUMANPURA GUMANPURA KOTA RAJASTHAN 324007 UDYAM RJ 17 0172124 | KOTA | RAJASTHAN | 324007 | ₹38.0 L | L4 | Rejected-Finance Other than lowest bidder. |
| 5 | L5₹39.6 LRejected-Finance | ₹39.6 L | L5 | Rejected-Finance Other than lowest bidder. |
| Sl No | Description | Qty | Unit | Sona Enterprises L4 | M/S RAVI KUMAR L2 | M/S BHAT ENGINEERS L3 | S S BUILDERS L1 | M/S ASHRAF HUSSAIN L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in hard / dense soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for laying of cables & foundation of poles, stay assembly, complete all as specified and directed by Engr-in-Charge. | 831.6 | Cum | 90 ₹74,844 | 100 ₹83,160 | 250 ₹2.1 L | 180 ₹1.5 L | 120 ₹99,792 |
| 2.00 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge. | 572.45 | Cum | 20 ₹11,449 | 50 ₹28,622.50 | 17 ₹9,731.65 | 10 ₹5,724.50 | 30 ₹17,173.50 |
| 3.00 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge. | 221.71 | Cum | 25 ₹5,542.75 | 50 ₹11,085.50 | 18 ₹3,990.78 | 10 ₹2,217.10 | 40 ₹8,868.40 |
| 4.00 | Taking out old unserviceable/serviceable un-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge. Note:- Serviceable un-reinforced concrete PCC cable cover kept in safe custody for reuse at site and unserviceable un-reinforced concrete PCC cable cover through in low lying area. | 19,000 | Nos | 0.5 ₹9,500 | 1 ₹19,000 | 1 ₹19,000 | 1 ₹19,000 | 10 ₹1.9 L |
| 5.00 | Laying only old reinforced PCC cable cover of any size as retrieved from serial item No- 04 above, complete all as directed by Engineer-in-Charge. | 5,000 | Nos | 0.5 ₹2,500 | 2 ₹10,000 | 1 ₹5,000 | 1 ₹5,000 | 10 ₹50,000 |
| 6.00 | M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge. | 14,000 | Nos | 10 ₹1.4 L | 20 ₹2.8 L | 36 ₹5.0 L | 3 ₹42,000 | 25 ₹3.5 L |
| 7.00 | M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge. | 230.85 | Cum | 270 ₹62,329.50 | 600 ₹1.4 L | 400 ₹92,340 | 100 ₹23,085 | 800 ₹1.8 L |
| 8.00 | S&F of galvanized iron pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate. | 24 | RM | 360 ₹8,640 | 600 ₹14,400 | 300 ₹7,200 | 200 ₹4,800 | 600 ₹14,400 |
| 9.00 | Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by Engr-in-Charge. | 1,980 | RM | 0.5 ₹990 | 1 ₹1,980 | 1 ₹1,980 | 1 ₹1,980 | 25 ₹49,500 |
| 10.00 | Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade 120 sq mm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as specified and directed by Engr-in-Charge. Make : Havells/Polycab/Plaza/Paramount or equivalent
Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items. | 30 | RM | 660 ₹19,800 | 851 ₹25,530 | 1,150 ₹34,500 | 1,000 ₹30,000 | 1,200 ₹36,000 |
Updated dates
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
6 Apr 2026, 6:00 pmClosed
GE 860 EWS
GE 860 EWS PIN-913860
REPAIR MAINT TO LT PANEL, FEEDER PILLAR BOXES, JUNCTION BOXES, MAINT REPLACEMENT OF MCCB, ACB AND CONNECTED WORKS SERVICES AND REPAIR MAINT REPLACMENT TO STREET LIGHT, SECURITY LIGHT, STREET LIGHT BRACKET, POLE PANTING VARIOUS SIZE OF LT UG CABLE
2026_MES_755498_1
8143/2026-27/E8
Open Tender
Civil Works
270 days
TANGTSE AND DURBUK
As per tender documents
9 documents required · 9 mandatory
₹500
GE 860 EWS Karu
₹1 L
16 May 2026
7 Mar 2026
8 Apr 2026
7 Mar 2026
6 Apr 2026
23 Mar 2026
Excavation in trenches in hard / dense soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for laying of cables & foundation of poles, stay assembly, complete all as specified and directed by Engr-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge.
Taking out old unserviceable/serviceable un-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge. Note:- Serviceable un-reinforced concrete PCC cable cover kept in safe custody for reuse at site and unserviceable un-reinforced concrete PCC cable cover through in low lying area.
Laying only old reinforced PCC cable cover of any size as retrieved from serial item No- 04 above, complete all as directed by Engineer-in-Charge.
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge.
S&F of galvanized iron pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by Engr-in-Charge.
Description all as srl item no 10.00 here-in-before but for cable size of 95 sqmm 3.5 core.
Description all as srl item no 10.00 here-in-before but for cable size of 70 sqmm 3.5 core.
Description all as srl item no 10.00 here-in-before but for cable size of 50 sqmm 3.5 core.
Description all as srl item no 10.00 here-in-before but for cable size of 25 sqmm 4 core.
Description all as srl item no 10.00 here-in-before but for cable size of 16 sqmm 4 core.
Description all as srl item no 10.00 here-in-before but for cable size of 16 sqmm 2 core.
Description all as srl item no 10.00 here-in-before but for cable size of 10 sqmm 2 core.
M & L for taking out unserviceable under ground cable of any size from trenches with brick protection for fault rectificaton and relaying the same after rectifying the defect or jointing complete all as specified and directed by Engr-in-charge Note : Excavation , earth work, PCC cover and sand shall be measured and paid separately under respective item
Supply and fix in replacement of cable jointing kit for 1100 volt (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70-150 sq mm all as specified and directed by Engr-in-charge. Make :3M/Raychem/Denson
Description all as per item Sl No. 19.00 here-in-before but of size 25 to 50 Sqmm
M & L for painting of LT Panel of any size and type by applying two coats of synthetic enamel paint super quality (Smoke grey) using spray gun after sraping old paint and and writing details of incoming and outgoing switch gear complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair off load change over switch 415 volt 50 Hz confirm to IS-13947-3 with enclosure and side handle of cap 400 Amp four pole including takind down old switch all as specified and directed by Engr-in-charge. Make Havells /C&S/Indoasian
Supply and fix in repair off load change over switch 415 volt 50 Hz conform to IS-13947-3 with enclosure and side handle of cap 200 Amp four pole including takind down old switch all as specified and directed by Engr-in-charge. Make Havells /C&S/Indoasian
supply and fixing in repair MCCB 100 amps capacity, 415 V, TPN, 25 KA including taking out US MCCB complete all as directed by Engr-in-Charge. Make Havells Cat part No. IHLASF0100 or equivalent in /L&T/C&S
Supply and fixing in repair MCCB 63 amps capacity, 415 V, TPN, 16/25 KA including taking out US MCCB complete all as directed ,Make Havells Cat part No. IHLASF0100 or equivalent in /L&T/C&S
S & F in repair MCCB, 4 pole, 400 Amps, 415 Volts , 36 KA adjustable thermal and magnetic setting complete all as directed by Engineer-in-Charge including taking down old and unserviceable one. Make : HAVELLS/ C&S/L&T
Description all as per item No.26.00 above here-in-before but of capacity 250 Amps 4 pole, 35 KA Make : HAVELLS/ C&S/L&T
Description all as per item No. 26.00 above here-in-before but of capacity 200 Amps 4 pole, 25 KA. Make : HAVELLS/ C&S/L&T
Description all as per item No. 26.00 above here-in-before but of capacity 100 Amps 3 pole, 25 KA. Make : HAVELLS/ C&S/L&T
Description all as per item No. 26.00 above here-in-before but of capacity 125 Amps 3 pole, 25 KA. Make : HAVELLS/ C&S/L&T
Supply, installing, testing and commissioning Factory made outdoor LT feeder piller box, double door type of suitable size, padestal mounted, CPRI approved totally enclosed, dust and vermin proof, Front and rear openable type made of 3.15 mm thick CRCA sheet and having proper locking arrangement duly painted to both internal and External surfaces with super enaleled paint over a coat of red oxide and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising of three phase aluminium busbarr of current carrying capacity 200 Amps and 01 No. 4 Pole 100 Amps MCCB for incoming ond outgoing connection mounted on angle iron legs of size 50 x 50 x 6 mm x 80 cm long embedded in PCC 1:3:6, including excavation / preparation of ground complete connecting UG cable with cable glands of suitable size Make :SMS Panels and Switch Gears/ Universal switch gears Control and equivalent
Supply, installing, testing and commissioning Factory made outdoor LT feeder piller box, double door type of suitable size, padestal mounted, CPRI approved totally enclosed, dust and vermin proof, Front and rear openable type made of 3.15 mm thick CRCA sheet and having proper locking arrangement duly painted to both internal and External surfaces with super enaleled paint over a coat of red oxide and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising of three phase coppere busbarr of current carrying capacity 400 Amps mounted on angle iron legs of size 50 x 50 x 6 mm x 80 cm long embedded in PCC 1:3:6, including excavation / preparation of ground complete connecting UG cable with cable glands of suitable size Make :SMS Panels and Switch Gears/ Universal switch gears Control and equivalent.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down unserviceable / defective street light fitting / Flood light fitting of any wattage alongwith mounting bracket, flat iron clamp, nuts bolts etc from overhead LT poles complete all as directed by Engr-in-Charge.
S&F of LED street light luminaire of 70 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge.
Description all as per item Ser No. 35.00 here-in-before but of capacity 35 Watt
S&F of LED flood light luminaire of 100 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge.
S&F of LED flood light luminaire of 200/210 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge.
S&F in replacement of street light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 40 mm dia size light grade complete with and incl 02 nos MS clamp made of MS flate iron of 50 x 6 mm size with nut, bolts, washer etc with and incl two coats of aluminum paint over a coat of red oxide primer, all as specified and directed by Engr-in-charge.
M&L for preparation old (exposed) painted surfaces of existing LT steel tubular street Light pole, struts including cross arms, clamps etc complete and applying two coats of aluminium paint over a coat of red oxide primer over the ground and making 30cm wide strip with black and yellow paint including numbering of HT/LT poles at a height of 1.5 mtr above ground level as per existing having 15mm width and 50mm bold letter complete all as specified and directed including Marking Red Stipn painting on HT Poles etc.
M&L 1.5 sqmm copper conductor twin core cable for connection of the street light with junction box / Over head LT line complete all as specified and as directed by Engineer-in-Charge.
M&L, in replacement, junction box outdoor type of size 280 X 170 X 130MM made out of Plastic sheet of thickness not less than 1.6 mm having hinged front opening door with two nos aluminium strip bus bar fitted on resin based insulator and flat iron fixing clamp of size 25mmX3mm and complete painted with two coat of synthetic enamel aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fixing in Repairs 30Watt LED solar street light fitting fixed to existing pole, including taking down old fitting, complete all as specified by Engr-in-Charge. Make: CG/Surya /Bajaj / Philips / Havells
S&F in Repairs 100AH, 12volt LMLA battery, suitable for long backup, including taking down old battery of any type, complete all as specified and directed by Engr-in-Charge. Make: Exide / Amaron / Power zone
S&F in repairs Solar light kit suitable for upto 30Watt solar lights, fixed in repair, all as specified and directed by Engr-in-charge. Make: CG/Surya /Bajaj / Philips / Havells
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.35 MB
Tender38143.pdf
Tender Documents • 0.31 MB
Tender18143.pdf
Tender Documents • 0.55 MB
Tender28143.pdf
Tender Documents • 0.69 MB
BOQ_846224.xls
BOQ • 6.77 MB
Download all tender documents and submit your bid