Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹21.0 LAdmitted-Finance 11 E 379 11 PUL PEHLL 110044 | SOUTH EAST DELHI | DELHI | 110044 | L1 | Admitted-Finance | ||
| 2 | L2₹24.8 L+₹3.8 L (18.2%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹26.4 L+₹5.4 L (25.9%)Admitted-Finance | L3 | Admitted-Finance |
Tender Value
₹27.8 L
EMD Value
₹55,603
Closing Date
10 Nov 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(E)/ELD-13/DDA
Executive Engineer (E), ELD-13/DDA, Near Hasanpur Bus Depot. Delhi.110092
SITC of 4 mtr poles for pathway lighting in various park under HD-6/DDA
2026_DDA_932587_1
43/EE/ELD-13/DDA/2026-27
Open Tender
Electrical Works
Percentage
60 days
As per NIT documents.
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹55,603
25 Nov 2026
31 Oct 2026
11 Nov 2026
1 Nov 2026
10 Nov 2026
1 Nov 2026
75 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, Fabrication and Installation of 4 mtr. high pole made out of 65 mm dia NB, B class G.I pipe ISI marked duly welded with MS base plate of size 300 mm x 300 mm x 12 mm thick with stiffener of size 130 mm x60 mm x 5 mm thick ,supplying and fixing of suitable size of bracket of B class G.I Pipe for mounting the light fitting on the pole, suitable earth stud on base plate , making suitable size hole in pole at suitable height of 3.4 meter from base plate for cable entry/exit, painting & numbering of pole, making suitable size hole in base plate for cable entry/exit into the pole and fixing the pole on the existing foundation with the nuts-bolts, washers etc. complete as required. | 85 | Each | 5,395 | ₹4,58,575 |
| 2 | Providing and laying in position1:1.5;3 ( 1 cement: 1.5 Coarse sand : 3 graded stone aggregate) reinforced cement concrete foundation of size 400 mm x 400 mm x 1200 mm deep (800 mm below ground level and 400 mm above ground level) for item no. 1 including excavation of earth, refilling, providing, cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm. dia-1350mm long (approx.) -8 Nos, and reinforcement ring of cold twisted bar of 8mm dia -1800 mm long (approx.) -9 nos, (with 150 mm spacing) including centring & shuttering as required with providing, fixing and positioning of one set of foundation bolts comprising of 4 nos., 16 mm dia, 750 mm long J-Type MS bolts (Threaded portion shall be galvanized) along with 3 nos. GI nuts and 2 nos. GI washers etc. per bolt and 1 no. anchor plate (3mm thick) of suitable size and providing 40 mm.(O.D) DWC/HDPE pipe ISI marked for cable entry & exit etc. complete as required. | 85 | Each | 6,290 | ₹5,34,650 |
| 3 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -50C to 50 C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency 85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 45 watt | - | Each | 1,744 | - |
| 4 | Supply & installation of pole connector box made out of Glass Reinforced Polyester Sheet Moulding Compound to IS : 13410-1992 grade S1 of approx. dimensions 240 mm(H) x 130 mm(W)x 95 mm (D) (all the corners of the box should be round & not pointed ones) suitable to mount on 40/50/65/80 mm dia GI pole with the following provisions/accessories mounting in box complete as reqd.
(i)2 nos. clamps made out of 19mm x 3 mm M.S. strip of suitable length for mounting box on the pole.
(ii) Water tight front cover with 2 nos. stainless steel hinges & 1 no. screw for tightening.
(iii)4 way, 220 V, 30 A, dough moulded connector (SMC with stainless steel inserts)
(iv) 5/6 amp. SPMCB 'C' Curve 10 kA---1 no.
(v) Suitable size hole at suitable location on rear/bottom wall for cable & wire entry.
(vi) Earthing bolt M6 x 20 mm | - | Each | 1,129 | - |
| 5Supply of following sizes of XLPE insulated & PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade confirming to IS :7098 (Part 1) i/c testing etc complete as reqd. | |||||
| 5.01 | 2C x 10 sq. mm | 3,200 | mtr | 191 | ₹6,11,200 |
| 6 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
a)3 x 1.5 sq. mm | 140 | mtr | 104 | ₹14,560 |
| 7 | Supplying and drawing following sizes of FRLS/HFFR, PVC insultated copper conductor, single core cable in the exisiting surface/ recessed steel/ PVC conduit as required. 1) 1x1.5 sq.mm DSR 2025(Electrical)-1.17.1 | 340 | mtr | 51 | ₹17,340 |
| 8 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal) | 2,000 | mtr | 289 | ₹5,78,000 |
| 9 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.
a)Upto 35 sq. mm | 2,600 | mtr | 47 | ₹1,22,200 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.43 MB
Tendernotice_2.pdf
PDF • 2.88 MB
BOQ_980034.xls
BOQ • 0.32 MB
Corrigendum43.pdf
PDF • 0.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .