Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAccepted-AOC | ₹4.2 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹4.4 Cr+₹21.3 L (5.12%)Rejected-AOC | ₹4.4 Cr+₹21.3 L (5.12%) | L2 | Rejected-AOC Accept |
| 3 | L3₹4.4 Cr+₹23.8 L (5.72%)Rejected-AOC | ₹4.4 Cr+₹23.8 L (5.72%) | L3 | Rejected-AOC Accept |
| 4 | L4₹4.5 Cr+₹31.6 L (7.59%)Rejected-AOC VPO MAJARI TEHSIL SHRI NAINA DEVI DISTT BILASPUR HP | ₹4.5 Cr+₹31.6 L (7.59%) | L4 | Rejected-AOC Accept |
| 5 | Rejected-Technical VILL PANOH PO CHOURI TEHSIL SUJANPUR DISTT HAMIRPUR H P | HAMIRPUR | HIMACHAL PRADESH | 174304 | - | - | Rejected-Technical Reject |
Tender Value
₹5.3 Cr
EMD Value
₹5.7 L
Closing Date
4 Oct 2023, 11:00 amClosed
EE JSV Division Bhoranj
EE JSV Division Bhoranj
C O of 1 No Percolation well with control room 1 No Sump Well 300000 ltrs cap 1 No main delivery tank 200000 ltrs. cap., P L Rising Main for Percolation well, P L gravity Main, Thrust block, Supplying and Errection of Submersible Pumping
2023_HPIPH_79276_1
EE.BHJ.tender-3503-3563 DT 21-09-2023
Open Tender
Civil Works
Item Rate
EE JSV Division Bhoranj
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,500
EE JSV Division Bhoranj
₹5.7 L
Superintending Engineer JSV Cirlce Hamirpur
9 Nov 2023
23 Sept 2023
4 Oct 2023
23 Sept 2023
4 Oct 2023
23 Sept 2023
28 Sept 2023
Amount
Percolation well:- Designing, Constructing, Testing & Commissioning ( to be approved by the competent authority) and Construction of Percolation well with 6.00 mtr internal diameter and 10.00 mtr depth below bed level and 6.00 Mtrs height above bed level ,having RCC Circular structure, Roofing with RCC slab, Walk way/passage CI Rungs inside the percolation from top to bottom and RCC stair case from ground level to top of percolation well including control pannel room over Percolation well with connecting path having arrangement of chain pulley of suitable capacity for lowering the pumping machinary, wire crate protection around the perculation well complete in all respects to the entire satisfaction of the Engineer-in-charge. The contractor shall provide 6 sets of approved drawing and design with one soft copy to the department. ( Data Sheet No.1 )
Excavation in foundation, trenches (for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chieselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposoited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts Excluding restoration metalled surfaces to its original condition( Will be paid Separately) & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-charge.
Providing and laying cement concrete 1:4:8(1cement:4sand:8 graded stone aggregate 40mm nominal size and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.
Providing form work with steel plated 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring,shuttering,strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for insitu-reinforced concrete and plain.
Vertical surfaces such as walls(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge and having arrangement for incoming water from upsteam side.
Providing and laying cement concrete 1:2:4(1cement:2sand:4 graded stone aggregate 20mm nominal size)and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:-
Foudation,footing base of column and the like mass concrete.
Providing, Laying mild or tor steel reinforcement for RCC. Work including bending binding and placing in position complete upto floor two level Tor steel in all leads and lifts.
C/O RCC Sump well/Tank:- Designing, Constructing, Testing & Commissioning (to be approved by the competent authority) RCC Circular under ground/partial under ground storage reservoir as per capacity given below at various stages/sites including excavation in foundation in all kinds of soil. including PCC (1:3:6) in foundation and M:30 design mix in bottom slab/raft ,walls and beams. And RCC (1:1.5:3) in roof slab/dome with provision of inspection path around the dome with all alied Civil Works such as c/o chamber for valves, refilling and disposing of surplus excavated earth with in all leads and lifts. The job also includes providing lowering, laying, erecting, hoisting and jointing of pipe assembly for inlet, outlet, overflow and scour pipe with bye pass arrangement consisting of GI / MS pipes special and valves of required classes and dia and all other accessories required such as MS ladders inside and outside, CI cowl type ventilator, SFRC manhole covers with frames of heavy duty with proper locking arrangement, water level indicator. The tanks shall be hydraulically tested for water tightness, All works shall be conforming to relevant IS code. The cost of valves,bulk meter/ flow meter shall be included in the rates of tanks .complete in all respects to the entire satisfaction of the Engineer-in-charge .The contractor shall provide 6 sets of approved drawing and design to the department including cost of site development required as per site conditions. ( Data Sheet No. 2)
C/O RCC Main Delivery Tank:- Designing, Constructing, Testing & Commissioning (to be approved by the competent authority) RCC Circular under ground/partial under ground storage reservoir as per capacity given below at various stages/sites including excavation in foundation in all kinds of soil. including PCC (1:3:6) in foundation and M:30 design mix in bottom slab/raft ,walls and beams. And RCC (1:1.5:3) in roof slab/dome with provision of inspection path around the dome with all alied Civil Works such as c/o chamber for valves, refilling and disposing of surplus excavated earth with in all leads and lifts. The job also includes providing lowering, laying, erecting, hoisting and jointing of pipe assembly for inlet, outlet, overflow and scour pipe with bye pass arrangement consisting of GI / MS pipes special and valves of required classes and dia and all other accessories required such as MS ladders inside and outside, CI cowl type ventilator, SFRC manhole covers with frames of heavy duty with proper locking arrangement, water level indicator. The tanks shall be hydraulically tested for water tightness, All works shall be conforming to relevant IS code. The cost of valves,bulk meter/ flow meter shall be included in the rates of tanks .complete in all respects to the entire satisfaction of the Engineer-in-charge .The contractor shall provide 6 sets of approved drawing and design to the department including cost of site development required as per site conditions. ( Data Sheet No. 3)
Providing ,Laying, jointing and testing in trenches of GMS pipe butt welded 95% joints butt welded & 5% Flanged joints pipes including cost of flanged bends of all degrees conforming to IS 1239- 2004 (Medium Class) with upto date ammendements ) as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube.The butt welded joints as per table below duly welded in three layers (one inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes confirming to BIS 1364 (with upto date ammendments).The laying of pipe shall include all operation such as cutting, welding, jointing, providing & fixing of fabrication of bends, tees, etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. Negative tolerance in thickness and mass/weight will not be accepted.The pipe shall be factory galvanized as per IS: 4736-1986 (with up to date ammendements) with zink coating not less than 400 gms/sqm. (earth work in trenches to be measured and paid separately ) ( Data Sheet No. 4)
G.I Pipe 150 mm (Medium Class)
Providing welding and fixing of M.S. flanges @ 5% of joints, conforming to following tables as per IS 6392-1971 (Latest with up to date amendments) and welding of MS flanges with GMS/GMSERW pipes in two layers on both faces i.e two layer on outer faces and one layer on inner faces to make the joint leak proof (The cost of proving and layer of GMSERW pipes to be measured and paid for separtely). The welding of flanges shoild conform to IS 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364, the thicthness of gasket not less than 3.00 mm conforming to IS 2712-1998. The work shall be done as per entire satisfactio of engineer in charge with in all leads and lifts.
M.S Flanges 150 mm dia. table -5
Providing circumferential butt welded joints by electrical arc welding to below mentioned dia with DPT testing and wall thickness GMSERW pipe welded in three number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore)-CITOJET/ES/ESAB make, conforming to IS 814-1991 including Die pentration test, at site of work complete in all respects, including manual/machanical handling of pipe in all leads and lifts, including DPT and coating of two coats of anticorrosive bituminous paint to the entire satisfaction of Engineer in charge.
GMS Pipe 150 mm diameter
Providing and fixing double flanged C.I Non return valve of Leader/Kirloskar make to rising main confirming to BS:5312-1986 as per class given below and capable of with standing 16.32kg/cm2 seat pressure with upto date ammendments.
150 mm dia PN 1.6 with MS Flange Table -5
Providing and fixing double flanged C.I Sluice valve of Leader/Kirloskar make to rising main confirming to BS:14846-2000 as per class given below and capable of with standing 16.32kg/cm2 seat pressure with upto date ammendments. 150mm dia PN 1.6 with MS Flange Table -5
Providing and fixing screwed C.I. Air release valve 40 mm dia single ball type approved make confirming to BS 1452-90 with upto date ammendments as per class -PN 1.0 to with stand a seat pressure of 11.22 Kg/cm2. in rising main.
Providing, laying, jointing and testing in trenches of Galvanized MSERW flanged/butt welded pipes including cost of flanged bends of all degrees conforming to IS/ISO:3183-2012 with steel grade L-390 or X-56 ( with upto date ammendements )having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube.The M.S. flanges are to be provided 5% of total joints and remaining 95% joints with butt welded joints as per table below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in three layers (one inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes confirming to BIS 1364 (with upto date ammendments). 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe shall include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees,valves etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. ( Data Sheet No. 5)
200 mm dia wall thickness 4.80mm L -390 (X-56) Gravity Main
Providing and welding M.S. flanges at suitable point, conforming to following tables as per IS 6392-1971 (Latest with up to date amendments) with plain end MSERW pipe in three layers (one inner and two outer) with pipes at both ends to make the joint leak proof (The cost of providing and laying of GMSERW pipes and butt welded joint to be measured and paid for separately). The welding of flanges should conform to IS: 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364 including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00mm conforming to IS 2712-1998. The work shall be done to the entire satisfaction of Engineer in Charge with in all leads and lifts.
M.S Flanges 200 mm dia. table -5
Providing circumferential butt welded joints by electrical arc welding to below mentioned dia with DPT testing and wall thickness GMSERW pipe welded in three number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore)-CITOJET/ES/ESAB make, conforming to IS 814-1991 including Die pentration test, at site of work complete in all respects, including manual/machanical handling of pipe in all leads and lifts, including DPT and coating of two coats of anticorrosive bituminous paint to the entire satisfaction of Engineer in charge.
GMSERW Pipe 200 mm diameter 4.80mm thick
Providing and fixing double flanged C.S Sluice valve of approved make to rising main confirming to BS:1868-API-600 as per class given below and capable of with standing 104.00Kg/cm2 seat pressure with upto date ammendments.
200mm ASA- 600 Table-38
Providing and fixing screwed C.I. Air release valve 80mm dia double ball type approved make confirming to BS 1452-90 with upto date ammendments as per class -PN 1.0 to with stand a seat pressure of 11.22 Kg/cm2. in rising main.
SUBMERSIBLE PUMPNG MACHINERY:-Supply & Installation of 3 star rated enrgy efficient Submersible pumping set of KSB/Calama/ WPIL/ Crompton/BS/ SABAR/ Oswal/ Kirloskar make conforming to latest relevant BIS Code 8034:1976. The pump should be fitted with bronze impeller or suitable alloys suitable for handling Clear water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP & 2900/1450 rpm of reputed make conforming to BIS 9283-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, erection clamps , cable, clips, depth gauge, double loop earthing, NRV, Sluice valves and actuated valves of approved class including errection charges etc. The work should be completed to the entire satisfaction of the Engineer-in – Charge. The HP are indicative.Since the re-survey and re-design of proposal/scheme is to be carried out by the lowest bidder, the design/drawings so approved by the competent authority after finalisation of design and drawings,any variation in HP and other accessories etc.The rate shall be worked out on prorata basis after approval of the competent authority and payment will be made accordingly.The rates shall be for complete Job to run the machinery in proper working. and should meet with the requirements. (Ist stage) For detailed design parameters/ requirements are given in Below. ( Data Sheet No. 6)
Booster stage 1 2 sets (1 working & 1 standbye) of discharge 16.13 LPS each and total Head :- 49.00 Metre.
Gaseous chlorination system
Supply, installation commissioning and testing of auto Gaseous Chlorination Plant at MS Tank. Vacuum operated pressure feed gaseous chlorinator of Chloromax/Capco/Capital makes for Chlorination of water by direct feeding to water main consisting of the following :- Chlorinator capable to deliver 0-1000 gm/hr of chlorine gas comprising of spring opposed inlet valve, valve, now meter remote ejector assembly with built in check valve, vacuume tubing, vent tubing and injection assembly complete in all respect. ( Refer Data sheet No.7 for further detail)
Supply and installation of UV system complete in all respect including all leads and lifts as per the direction of Engineer-in-charge.( Refer Data sheet No.8 for further detail)
SS RANA CONSTRUCTION PRIVATE LIMITED
HILL CONSTRUCTION AND ENGINEERING CO. SOLAN
MS Kamal Dev Sharma
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .