| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹5.2 L+₹46,350 (9.79%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹5.9 L+₹1.2 L (24.7%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹5.9 L+₹1.2 L (25.7%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹6.2 L+₹1.5 L (31.0%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
7 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
CERTAIN REPAIRS/REPLACEMENT OF MCBs, DBs, SUBMAIN WIRING AND EARTHING AT 8 FBSU, AF STATION AWANTIPUR
2020_MES_361676_1
GE (AF) AWA -11/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹17,000
Yes
18 Aug 2020
17 Jul 2020
10 Aug 2020
17 Jul 2020
7 Aug 2020
31 Jul 2020
60 days
Amount
Takingdown submain wiring of any size including casing caping terminated in batten by disconnecting the same from main board/ switch and keeping aside in safe custody and making the surface good, complete all as specified and directed.
Takingdown submain wiring of any size from existing conduit terminated in batten by disconnecting the same from main board/ switch and keeping aside in safe custody and making the surface good, complete all as specified and directed. Note:- Conduit shall not to be taken down.
Submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4sqmm complete drawn in and including casing caping of suitable size and its accessories along with 1x 4sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and as directed. Note :- 2 +1 run of 4Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4sqmm complete drawn in existing conduit with 1x 4sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and as directed. Note :- 2 +1 run of 4Sqmm cable shall be measured as one running metre.
Submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6sqmm complete drawn in and including casing caping ISI marked of suitable size and its accessories along with 1x 6sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified. Note :- 2 +1 run of 6Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6sqmm complete drawn in existing conduit along with 1x 6sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and as directed. Note :- 2 +1 run of 6Sqmm cable shall be measured as one running metre.
Replacement of existing DB's double door with new factory made load line DB's double door made out of CRCA mild steel sheet with insulating material like polyester epoxy coated surface mounting 4 way TPN 415 volts, vertical type, surface mounting with suitable busbar, neutral link and earth link suitable for MCCB TP as incomer and MCB SP/TP as out going complete with and including one No. MCCB 100 Amps, 3 pole,25 kA fixed type for incoming, complete all as specified and as directed.
Replacement of existing sheet metal enclosure with new sheet metal enclosure DB TPN 4 way, double door, 415 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB TP/TPN as incomer and MCB SP as outgoing, complete all as specified and as directed.
Replacement of existing sheet metal enclosure with new sheet metal enclosure DB SPN 4 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and as directed.
Replacement of existing sheet metal enclosure with new sheet metal enclosure DB SPN 8 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and as directed.
Replacement of existing sheet metal enclosure with new sheet metal enclosure DB SPN 12 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and as directed.
Replacement of existing sheet steel plug & socket with new sheet steel plug & socket DB's SP with metal clad 2 pin & earth plug and socket SPN, 20 Amps, 230 volts AC, concealed type, complete with & including one MCB SP, 20 Amps, 10 kA, including grouting in wall and making good to disturbed surfaces to match existing, complete all as specified and as directed.
Taking down MCBs of any size from existing DB's, complete all as specified and as directed.
MCB SP, 10-32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, complete all as specified and as directed.
MCB SPN, 32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, complete all as specified and as directed.
MCB SPN, 40-63 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type,complete all as specified and as directed.
MCB TPN, 40-63 Amps, 415 volts, 10 kA rupturing capacity, 'C' curve type, complete all as specified and as directed.
CFL 36 watt 4 pin type, complete all as specified and as directed.
Earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4mm dia bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20mm bore from bottom of earth pit to top of electrode and 20mm GI pipe light grade for earth wire protection complete with earth pit in plain cement concrete 1:2:4, type B0 using 12.5mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete 1:2:4, type B-I , using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Sch 2009 Part-I, and as directed . Note:- Earthing to be done for replacement of existing earthing. The materials retrived from earthing shall be credited to contractor.
Note :- An amount of Rs. 4,465.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
MS Ghulam Hassan and Sons
FG CONSTRUCTION
M/S ABBAS M. ENTERPRISES
M/S BASHIR AHMAD AND SONS
BHAT CONTRACTORS AND GENERAL ORDER SUPPLIERS
M/S SHAH RAOUF
ORISON ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .