| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | L1 | Accepted-AOC Ok | |
| 2 | L2₹29.7 L+₹4.6 L (18.1%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹36.4 L+₹11.3 L (44.8%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹37.5 L+₹12.4 L (49.2%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹38.6 L+₹13.5 L (53.7%)Rejected-Finance SPECIAL 1 INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 | JODHPUR | RAJASTHAN | 342003 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
4 Apr 2022, 6:00 pmClosed
GE E/M BASE HOSP DELHI CANTT
GE E/M BASE HOSP DELHI CANTT-110010
REPAIR/ REPLACEMENT OF UNSERVICEABLE SPARES OF COOLING TOWERS, AHUS, PUMPS AND REWINDING OF ITS MOTORS AND REPAIRING OF NORMAL OUTDOOR UNIT WITH VRF BASED OUTDOOR SYSTEM AND CONNECTED MISC E/M WORKS AT BASE HOSPITAL DELHI CANTT-10
2022_MES_510719_1
GE/BH-81/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE E/M BASE HOSP DELHI CANTT
Class D Category c(i)
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSP DELHI CANTT
₹94,000
Yes
10 Aug 2022
28 Feb 2022
6 Apr 2022
28 Feb 2022
4 Apr 2022
14 Mar 2022
Amount
Taking out the filter from AHU up to 1000 CFM to 13000 CFM cleanning coil with suitable chemical and jet of water pressure with pump and remove all the scale and foreign material deposited in side the coil followed with air pressure to sweep up all the particles and ensure thorough flow of air over the cooling coil complete all as specified and directed for any capacity of AHU and refixing the air filter after cleaning.
M&L for repairing/ servicing AHU Fan Motor of following capacity, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of size & discription to match with existing including insulating materials, varnishing, drying, replacement of both driven end & non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed:-
5 HP/ 5.5 HP AHU fan motor, Make-Kirloskar, Cromton Greaves, Model-1622 TOP
7.5 HP AHU fan motor, Make- Kirloskar, Bharat Bijlee, ABB, Model-KI 1325 & M2BA 132S4
10 HP AHU fan motor, Make- ABB, Model-M2BA 132M-4, SMC-4 & HX-132SM64
Taking up or down 40 mm bore MS pipe from trenched/ wall surfaces or in any position complete all as specified and as directed.
All as per item No 3.00 here-in-before but of pipe 50 mm bore.
All as per item No 3.00 here-in-before but of pipe 65 mm bore.
All as per item No 3.00 here-in-before but of pipe 80 mm bore.
All as per item No 3.00 here-in-before but of pipe 100 mm bore.
All as per item No 3.00 here-in-before but of pipe 125 mm bore.
All as per item No 3.00 here-in-before but of pipe 150 mm bore.
Supply and lay MS pipe condenser water or cooling tower piping of MS 'C' class 40 mm dia confirming to IS-1239 and IS- 3589 both revised till date as required and as specified and complete with bends, reducers tees, supports vibration pipe supports,structures shall be painted with 2 coats of synthetic enamel paint over a coat of red oxide primer and complete all as specified & directed.
All as per item No 10 here-in-before but of pipe 50 mm bore.
All as per item No 10 here-in-before but of pipe 65 mm bore.
All as per item No 10 here-in-before but of pipe 80 mm bore.
All as per item No 10 here-in-before but of pipe 100 mm bore.
All as per item No 10 here-in-before but of pipe 125 mm dia.
All as per item No 10 here-in-before but of pipe 150 mm bore.
M&L for taking out Cooling Tower Motor of following capacity, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of size & discription to match with existing including insulating materials, varnishing, drying, replacement of both driven end & non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed:-
2 HP Cooling Tower Motor
3 HP Cooling Tower Motor
5 HP Cooling Tower Motor
S&F in repair all accessories corroision proof PVC Filling, inlet louvers, drift, PVC eliminators,PVC water distribution chamber and nozzeles (self rotating sprinklers) GI nut bolt (included float valve)and all fitting complete all as specified & directed. Note:- (a) The spray system should be work satisfactory even with 50% reduced flow of water. (b) The induced draught cooling tower should be operate according to the counter flow principle. (c) Cooling tower specification for PVC filling (Delta make) (i) Capacity - 90 TR (ii) model - 5161 (iii) water Flow - 290 USGPM (iv) Water in - 97.5° F (v) Water out - 90° F (vi) Design wet bulb temp - 83° F (vii) Max approach for Cooling Tower - 5°F
S&F in repair all accessories corroision proof PVC Filling, inlet louvers, drift, PVC eliminators,PVC water distribution chamber and nozzeles (self rotating sprinklers) GI nut bolt (included float valve) and all fitting complete all as specified & directed. Note:- (a) The spray system should be work satisfactory even with 50% reduced flow of water. (b) The induced draught cooling tower should be operate according to the counter flow principle. (c) Cooling tower specification for pvc filling (Delta make) (i) Capacity - 35 TR (ii) model - 5132 (iii) water Flow - 125 USGPM (iv) Water in - 97.5° F (v) Water out - 90° F (vi) Design wet bulb temp - 83° F (vii) Max approach for Cooling Tower - 5°F
Dismantling of existing AHUs of any size and capacity from AHU room with cutting and removing of existing water chiller pipeline and valves and deposted to MES store yard of AGE E/M BHDC complete all as specified and directed.
Supply, installation testing, commissioning of outdoor type all weather Air Handling Unit 4400 CFM & 35mm static installed on anti vibration pads and supports as per OEM recommendation with inbuilt dampers (For Supply, Return, Fresh Air and Exhust Ducts) with following equipments and its specifications- MAKE : ZECO/ CITIZEN/ LOYDDS AHU CAPACITY – Air Handling Unit should be capable to deliver 6800 CFM at 35mm Static Pressure. CASING – The housing / casing of Air Handling unit shall be of double skin construction. Casing frame work shall be of extruded aluminum section with thermal break barrier aluminum profiles. Thermal Break Double skin panel shall be made of outer skin 0.8mm pre coated GI sheet and inner skin 0.6mm plain stainless steel sheet, insulation in both skin should be 45mm thick CFC free puff injected insulation of 40KG/ cubic meter density. Panel should be screwed to the frame work with soft gasket to make air tight joint. Suitable doors with powder coated hinge shall be provided for access to maintenance. Low leakage of AL constructed volume control dampers with should be providing for Return Air/ Fresh Air/ Exhaust Air/ Supply Air.
FAN – FC fan motor should be provide with direct couple arrangement. as per OEM recommendation . Fan Dia :- 450 Fan RPM :- 642 Fan oultet velocity :- 9.95 M/S Shaft absorbing power :- 2.01 Motor Rating :- 3.7 KW Motor Pole :- 4 pole HEATER :- 9 kw FILTER – Synthetic (non Woven type) Efficiency of pre -filters (EU-4) :- 90 % down to 10 micron SAFTY :-Limit Switch – fan section all doors should be provided with fitment of limit switch and lamps.Fan section door should be providing with wire guard to protect any casual entry inside the AHU.Fan suction port should have diffusion plate. AHU CONTROL PANEL : Supply, installation testing, commissioning of AHU control panels with following specifications:- MCB for AHU, MCB for Contractors for controlling temperature and heater bank, Temperature controller with sensors, Contactors etc all as recommended and specified by OEM.
Supply only, in replacement heating element capacity 3 KW, ISI marked and making electric connections and taking down old unserviceable heating elements, complete all as directed. Make : Daspass/ Theata
S&F in repair 50mm thick box type Pre-Filter (EU-4) Synthetic media type flange type (non woven type ) efficency - 90% down to 10 micron with complete all fitting for AHU and 50 mm wg static pressure with rod support fabrication with GI/Aluminium frame, suitable for AHU of make fedders lloyd all complete as specified & directed. Make for filter :- Athlete/ AAF/ Fredenberg
S&F in replacement Absolute HEPA filter of size 830 x 550 x 690mm having rated flow 2000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed. Make - Thermadyne / Spectrum / Puromatic / Athlete
S&F in replacement Absolute HEPA filter of size 610x610x305mm having rated flow 2000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed. Make - Thermadyne / Spectrum / Puromatic / Athlete
S&F in replacement Absolute HEPA filter of size 610x305x305mm having rated flow 1000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed. Make - Thermadyne / Spectrum / Puromatic / Athlete
S&F in replacement Air filter for Air cooled type package type (Blue star pakage Unit Model : DPA1322R2) Suitable for 22 TR air Conditioners of material Non woven polyster media enclosed by HPDE mesh filter size should be (H x w) 1250 mm x 658 mm of grade G3 complete all as specified and directed.
S&F in repair Air filter for Air cooled type package type (Blue star pakage Unit Model : DPA1983R2) Suitable for 11 TR air Conditioners of material Non woven polyster media enclosed by HPDE mesh filter size should be (H x w) 828 mm x 577 mm of grade G3 complete all as specified and directed.
S&F in repair Air filter for Air cooled type package type (Blue star pakage Unit Model : DPA2642R2) Suitable for 16.5 TR air Conditioners of material Non woven polyster media enclosed by HPDE mesh filter size should be (H x w) 933mm x 457mm of grade G3 complete all as specified and directed.
Excavation in trenches not exc 1.50 mtr wide or 10 sqm on plan, 1.50 mtr for manholes & sewage lines, drain, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and directed.
M&L for removing excavated soil to a distance exc 500 mtr and not exc 1.0 km and depositing where directed complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6M mean redius built in cement mortar 1.6 including demolition of old brick complete all as specified and directed.
M&L rendering 15mm thick in cement mortar 1.4 on other than fair faces of brick surfaces of walls finished the surface fair and even without using extra cement complete all as specified and directed.
Supply & charge the refrigerent R - 407 Gas complete all as specified and directed. (Make:- Mafron/ Freon/ Floron)
Supply & charge the refrigerent R - 410 Gas complete all as specified and directed. (Make:- Mafron/ Freon/ Floron)
Supply, assembly and erection in replacement 24 Gaug GI sheet with C & SS rectangular/ square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete including necessary MS Channels, gurder supports as approved by Engr-in-Charge including making of hole in any type of wall and making good with plastering work, masonry work and necessary MS channel supports complete all as specified and directed
Supply & erection in replacement 25 mm thick nitrile duct thermal insulation with Aluminium foil, non-fibrous, fire retardant, closed cell, tri- dimensional, chemically cross linked polyethylene foam, confirm to class O' for fire propagation and class 1 for surface spread of flame & factory laminated aluminium foil complete all as specified and as directed.
Supply and fixing in replacement air volume control damper with connected accessories, made out of 22 Gauge GI sheet with flap and operatig handle complete all as specified and as directed.
Supply and fixing fire proof double layered canvas cloth connection for AHU outlet including inspection opening complete with flanges made out of 22 GSS Sheet on both side for connection to AHE and duct complete with nuts, bolts complete all as specified and directed.
M&L for insulation of 40mm bore MS pipe with PUF slab 30 mm thick with applying bitumainous compound and GI cladding with 26 guage GI sheet etc cmplete including taking down existing PUF insulation all as specified and directed.
All as per item No 42 here-in-before but of pipe 50 mm bore.
All as per item No 42 here-in-before but of pipe 65 mm bore.
M&L for insulation of 80mm bore MS pipe with PUF slab 40 mm thick with applying bitumainous compound and GI cladding with 26 guage GI sheet etc cmplete including taking down existing PUF insulation all as specified and directed.
Supply only in replacement of ball bearing NU205EP with metal housing complete all as directed. Make : TATA/ SKF
Supply only in replacement of ball bearing P-206 with metal housing complete for AHUs of different capacity all as directed. Make : TATA/ SKF
Supply only in replacement of ball bearing P-207 with metal housing complete for AHUs of different capacity all as directed. Make : TATA/ SKF
Supply only in replacement of ball bearing P-208 with metal housing complete for AHUs of different capacity all as directed. Make : TATA/ SKF
Supply only in replacement of ball bearing P-209 with metal housing complete for AHUs of different capacity all as directed. Make : TATA/ SKF
S&F in replacement of ball bearing No 6201, incl dismantling of old unserviceable bearing complete all as directed. Make : NBC/ SKF/ MNR/ TATA
S&F in replacement of ball bearing No 6202, incl dismantling of old unserviceable bearing complete all as directed. Make : NBC/ SKF/ MNR/ TATA
S&F in replacement of ball bearing No 6203, incl dismantling of old unserviceable bearing complete all as directed. Make : NBC/ SKF/ MNR/ TATA
S&F in replacement of ball bearing No 6204, incl dismantling of old unserviceable bearing, complete all as directed. Make : NBC/ SKF/ MNR/ TATA
S&F in replacement of ball bearing No 6205, incl dismantling of old unserviceable bearing, complete all as directed. Make : NBC/ SKF/ MNR/ TATA
Supply only in replacement of un-armoured 10 Sqmm (nominal area), PVC insulated, 4 core, unsheathed and stranded copper conductor cable, ISI marked and making all electric connections, complete all as directed.
S&F in repair 3 pole power contactor 415 V, type MNX 70 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed. Make- SIEMENS/ L&T/ BHARATIA CUTTLER HAMMER
S&F in repair 3 pole power contactor 415 V, type MNX 50 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed. Make- SIEMENS/ L&T/ BHARATIA CUTTLER HAMMER
S&F in repair 3 pole power contactor 415 V, type MNX 25 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed. Make- SIEMENS/ L&T/ BHARATIA CUTTLER HAMMER
Supply only in replacement of thermal over load relay range 20-33 Amps, with built in single phase preventer, direct/ separate mounting on contactors, as required, with and incl taking down of unserviceable relay and making all electric connection, complete all as directed. Make : L&T/ Schneider Elect/ Siemens/ C&S/ Legrand
All as per Srl item No 60 here-in-above but 14-23 Amps capacity.
All as per Srl item No 60 here-in-above but 9-15 Amps capacity.
All as per Srl item No 60 here-in-above but 1.4 - 2.3 Amps capacity.
M & L for Panting of complete water cooled central AC plant and DX type AC plant, compressor, GI pipe lines, valve, pump sets, cooling tower, AHU pipe lines and chiller pipes etc complete all as specified and directed.
3 x 12.5 TR AC plant
3x 12 TR AC Plant
4 x 15 TR AC plant
3 x 30 TR AC plant
S&F in replacement, of MCCB 100 Amp, 3 pole thermal magnetic relese based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed. Make- Siemens/ L&T/ Schneider Elect/ C&S
S&F in replacement, of MCCB 200 Amp, 3 pole thermal magnetic relese based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed. Make- Siemens/ L&T/ Schneider Elect/ C&S
S&F in replacement, of MCCB 400 Amp, 3 pole thermal magnetic relese based with breaking capacity 50 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed. Make- Siemens/ L&T/ Schneider Elect/ C&S
S&F in replacement, of MCB 63 Amp, - pole thermal magnetic relese based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed. Make- Siemens/ L&T/ Schneider Elect/ C&S
RUCHIKA ENGG.WORKS
Vishal Traders
Saini Enterprises
INDO CONSTRUCTION
M/s Birja Nand
sony engineering works
M/S Rohit Enterprises
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .