Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | Admitted-Finance |
| 2 | Admitted-Finance NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical NOT QUALIFIED |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
19 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE ARMY BANGALORE
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
MAINT/REPAIR/REPLACEMENT OF EXTERNAL ELECTRIC NETWORK HT AND LT INSTALLATION/NETWORK UNDER GE (CENTRAL) BANGALORE
2020_MES_377981_1
86007/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bangalore
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (Central) Bangalore
₹40,000
Yes
HQ CWE ARMY BANGALORE
16 Nov 2020
16 Sept 2020
21 Oct 2020
16 Sept 2020
19 Oct 2020
7 Oct 2020
16 Sept 2020 - 25 Sept 2020
25 Sept 2020
60 days
Amount
M&L for filtration of transformer oil off load at site using hot oil filtration at site using oil fitration plant on mobile van, testing of oil should be carried out before filtration and after filtration and also checking the acidity of oil with acidity test kit before and after filteration to with stand for one minute for 2.5mm gap on 45 KV volts on testing, and connecting the transformer on load for its smooth functioning tranformer of capacity 100 KVA to 350 KVA, all as specified and directed. Note: 1 Top up transformer oil to till conservators desired level,to be measured and paid seperately Note : 2 Necessary test certificate of oil testing to be submitted by the contractor, Quoted rated inclusive of all necessary arrangment of filteration plant, empty barrels for storage of drain out oil etc as reqd at site.. complete all as directed.
Supply and top up/replacement transformer oil having with high viscosity and di-electric strength to with stand for one minute for 2.5mm gap on 45 KV volts on testing equipment. complete all as directed. Make : Electrol /Transoil /HP/ BP/poweroil.
M&L for servicing/cleaning of transformer by opening Top cover, replacement of top cover gasket with new corksheet not less than 6mm thick, replacement of gasket of LT and HT bushes, replacement Brass studs of LT / HT connection with porceiline bushes, including replacement of washer, check nuts & Rubber gasket to arrest leakage of oil etc as required at site for transformer capacity upto 350 KVA complete re-fixing and making existing electrical connections and testing of trasformer on existing connected load for its smooth fuctioning all as dircted by Engr-in-charge at site.Note : LT /HT studs with studs/stumps porcelain bushes and nut, washers etc will measured and paid separately if required.
250 KVA to 315 KVA
100 KVA to 200 KVA
Supply only non-metal part HV bushing complete with packing for tranformer of capacity up to 315 KVA and for working pressure 11000 Volts complete all as directed.
Supply only non-metal part LV bushing complete with packing for tranformer of capacity up to 315 KVA 11000/0.433 KVand for working pressure 11000 Volts complete all as directed.
Supply only Brass studs/stumps bushing with brass nuts as per site requirement for LV side complete with packing for tranformer of capacity up to 315 KVA complete all as directed.
Supply only Brass studs/stupms bushing with brass nuts as per site requirement for HV bushing complete with packing for tranformer of capacity up to 350 KVA 315 KVA complete all as directed.
Supply & fill Blue colour Silicagel for transformer breather as per site requirement for tranformer of capacity up to 350 KVA complete incl taking down of old silicagel in breather complete all as directed.
Supply & fix Silicagel breather for transformer with packed silicagel unit as per size and capacity at site requirement for tranformer of capacity up to 350 KVA complete,incl taking down of old breather complete all as directed
Supply and fix cable jointing kit for 11 KV grade (Earthed) cable for out door end termination Hot shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured AL conductor cable of size 50 to 95 sqmm connected up to existing terminal and including taking out old one. complete all as directed.
Supply and fix heat shrink straight through jointing kit for 11 KV (Earthed) grade cable complete with jointing material and accessories suitable for 3 core XLPE armoured AL conductor cable of size 50 to 95 Sqmm including taking out old one. complete all as directed.
Supply and lay mild steel galvanised pipe light grade for protection & passing of LT/HT cable fixed to poles / wall /laid under floor /roads complete,including fittings /clamps as required at site all as specified for size 150mm bore dia.Note: Clamps, nuts& bolts etc will be measured and paid under revant item.
Earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6.00mm thick buried directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to earth using GI Strip 32mm x 6mm by means of of nuts, bolts and washer and check nuts of GI or steel all as shown in electrical plate No:3 connected to main HTstructure / Panels /equipments including necessary earth work and excavation and including PCC chamber with 1:3:6 type C-2 and cover using steel sheet 3mm thick with handlle and frame of angle iron 25x25x5mm, GI medium grade 25mm bore pipe for watering common salt chorcoal, funnel wiremesh and earth test point terminal block & testing on completion all as specified and including dismantling of old earthing material. complete all as directed.
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in gound or drawn in conduit/pipe or fixed on pole or any other indicated situation for loof earthing etc as required 32x6mm GI strip incl taking down of old unserviceable strip. Complete all as directed.
Supply and fix 11 KV ,400 Amps ,out door 3-phase Triple pole Group operated (GOD) in replacement of triple pole ,mechanically operated mechanism mounted on steel frame and insulators, operating from ground level with GI Pipe 25 mm dia heavy duty & handle,fixed on 2- Pole structure type horizontally mounted single break conforming to IS-1818-1961, includind taking down old one complete all as specified Make: Jaipuria / Pactil/SKI.
Supply and fix 11 KV pin type insulator Porcelain,vitrous,white, brown or green insulator incl one galvanised mld steel spindle ,two galvanised washers and one galvanised iron nut,150 mm hight,150mm dia for 11000 volts grade including taking down of old U/S insulators and nuts all as specified and directed Make:Jaipuria / Pactil/SKI.
Supply and fix Drop out fuse11 KV assembly, expulsion type fuse single pole of current rating up to 50 Amps, mounted on 2 x insulator and steel frame,to connect with GOD with jumping wires and to outgoing HT cables. complete all as directed.
Supply and fix cross arms, MS channel,angle section bracing supports, clamps and back plates fabricated from structural steel section, including nuts, bolts, washers, welding work, bending cold or hot drilling holes for bolts in any shape or size as indicated and icluding of one coat of primer , one coat of finishing paint complete all as directed.
Supply and fix HT lightning arrestor expulsion type 11000 volts grade metal oxide type with 65 KA discharge capacity complete as per IS-3070 Part one III and IEC 1994 with all fittings and connections ,transmission class, including taking down of old unserviceable L/A complete all as directed.
Supply and fixing under ground cable route indicating slab of size 60cm length, 30 cm width, and 10cm thick, casted in PCC 1:3:6 and words "MES UG HT Cable 11KV" engraved to both side including arrow mark towards end point and slab grouted in ground 30cm deep in PCC 1:4:8 complete complete all as directed.
Supply and fixi Danger notice board of 1.6mm thick mild steel sheet, painted vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT 11000 volts,of size 25 x 20 cm size conforming to IS 2551 incl taking down old one complete all as directed
Supply and fix compression /crimping type (R,Y,B) three coloured sleeves tubes for conductors jointing / jumper connections including treatment with conducting jelly complete all as directed
Supply only HT Fuse wire tinned copper and working pressure 11000 volt grade of.following capacity. Complete all as directed
Current carring capacity 05 Amps
Current carring capacity 10 Amps
Taking out worn out/damaged/unserviceable PVC insulated underground cable armoured, heavy duty with aluminium conductors of any size, 11000V grade from trench/duct/ pole/ wall/pipes/rooftops etc. complete all as specified and directed.
Supply and laying jointing,testing & commissioning in trenches,fixed on pole/drawing through pipes, HT UG Cable XLPE insulated,screened,PVC beded galvanised steel strip or wire armoured electric cable heavy duty with stranded aluminium conductor 11000 volts grade,95 sqmm cross sectional area 3-Core complete all as directed. Make: Havells / plolycab / plaza
M& L laying on under ground cable,un reinfoced precast concrete cable cover,class HV, type-1 with flat,slab of size 300mmx180mmx40mm.laid on flat across the cable the cable lenth complete all as directed
Excavation in trenches in hard/dence soil,not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr in depth and geting out in hard/dense soil complete all as directed.
All as per Item No 27 but depth exc 1.5m but not exceeding 3m complete all as directed
Returning filling in including spreading, leveling, watering and well ramming in layers not exe. 25 cm. complete all as directed
Removing exacavated surplus excavated material to a distance exceeding 50m and depositing where directed at a level not exe. 1.5 m above the starting point. complete all as directed
M & L for supply River sand and spread and levelling in layer n exc 25 cm thick for cable in excavation. complete all as directed.
M & L Taking out existing stone aggregate and kept aside for re-spreading after cleaning, removing grass, vegetation etc including levelling the ground, raming & finally spreading new graded coarse stone aggregrate 63mm size complete all as directed.
M&L for painting the chain link fencing and steel sections with a coat of primer & two coats aluminium paint over it complete including preparation of old painted surfaces complete all as directed
M & L Dismantling of old unserviceable concrete poles/struts of any size. complete all as directed
M & L for Supply and erect steel tubular swaged poles Type - 410 SP-55 11 meter long complete with cast iron base plate, finial taper plug, bolts, nuts & screws all as specified and : Note:Earth work and PCC work in foundation/pole coping will be measured and paid separately under relevant items.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded hard granite stone aggregate) in foundations for pole or in filling complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20 mm graded hard granite stone aggregate) as in coping complete all as directed
Cutting the existing road/hard standing etc of any description of surface and excavation in trenches 30cm wide and 60 cm depth for laying of UG electric cable and all as directed. (The rate includes returning, filling, watering and ramming in layers and making good the surface as the existing after laying of electric cables). Complete all as directed.
M&L for cleaning scrapping prepairing the old steel surface of trasformer any description with two coat smoke grey enamal paint Complete all as directed
100 to 200 KVA Capacity
250 to 350 KVA Capacity
M&L for Dismantling and refixing the existing out/in door any type and capacity transformer rewinding with super enamelled copper conducting wire, DPC/Strips as per the existing out/indoor type transformer 100 KVA to 350 KVA,including connections for tap changer with winding,and removing of existing unserviceable burnt/damaged,defective HV/LV windings of transformer and provision of insulating material such as cotton tape impregated paper,PVC sleeves,bakelite or fibre seperators and seperating meterial betweem coils,varnish,nuts,bolts,sleeves and HT/LT tapes etc,as required and fixing coils in core assembly in position complete all as Specified & directed for installation and connecting the existing load for proper functioning in all respect. Note: Enamelled copper winding measured and paid separately
Supply only enameled copper wire/copper stip (DPC) or as per existing for HV side (11KV) transformer coil. Complete all as directed.
Supply only enameled copper wire/copper stip (DPC) or as per existing for LV side (0.433 KV) transformer coil. Complete all as directed.
SREE VARU ELECTRICALS
B5BUILDING SOLUTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .