| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹28.4 L+₹27,825 (0.99%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹32.9 L+₹4.8 L (17.2%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹37.5 L+₹9.4 L (33.4%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹38.8 L+₹10.7 L (38.2%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 Dec 2019, 6:00 pmClosed
CWE (AF) Gurgaon
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-110010
REPAIR MAINTENANCE OF EXTERNAL WATER SUPPLY AND ALLIED WORKS AT AF STN GURGAON UNDER GE AF GURGAON
2019_MES_303391_1
CWE/GGN/G-39/2019-20
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Gurgaon
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹90,000
Yes
12 Feb 2020
3 Dec 2019
30 Dec 2019
3 Dec 2019
27 Dec 2019
20 Dec 2019
3 Dec 2019 - 27 Dec 2019
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 m depth and n.exc 1.5 m wide for laying of pipes/cables etc and getting out complete all as specified and directed.
M & L for Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Taking up or down CI Pipes including all fittings such as spigot and socket ends, bends, elbows tee etc laid complete in trenches all as specififed of sizes :-
80mm bore
100mm bore
150mm bore
200mm bore
300mm bore
Taking up, 100mm bore, DI water mains (including all fittings) with spigot and socket ends and rubber tytan joints including removing out joints complete all as specified and directed.
Supply, Laying and Testing of cast iron pipes with spigot and socket ends and centrifugally cast class LA, in any length, laid in trenches complete all as specified and directed of following sizes :-
80mm bore
100mm bore
150mm bore
200mm bore
300mm bore
M&L for, 100mm bore, DI water mains (including all fittings) with spigot and socket ends and rubber tytan joints Class K9 in any length laid in trenches complete all as specified and directed.
Taking up or down steel tubing and connections including all fittings such as bends, elbows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :-
15mm bore
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
100mm bore
S & F in repair steel tubing and connections including all fittings such as bends, elbows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :-
15mm bore
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
100mm bore
S & F in replacement Gun metal Gate valve with iron wheel head screwed both ends complete all as specified and as directed of sizes :-
40 mm dia
50 mm dia
20 mm dia
25 mm dia
S & F as in repair check valve heavy duty of gun metal both end threaded and leaf spring loaded vertical type including removing unserviceable foot valve from the suction pipe of the pump set complete all as specified and directed of following sizes :-
100 mm dia
80 mmm dia
50 mm dia
S & F in replacement CI non return valve complete all as specified and directed of following sizes :- .
150 mm dia
100 mm dia
80 mmm dia
50 mm dia
M & L for Cutting existing CI or steel tubing of any size for alterations or additions and screwing complete all as specified and directed.
Demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of black synthetic enamel paint over one coat of primer etc. complete all as shown on drawing NO TD/2004/26 Sh 1/1 to 1/3 and complete all as specified and directed for the following sizes:-
900mm x 750mm x 900mm
900mm x 600mm x 1000mm
S & F in replacement Cast Iron sluice valve, class PN- 1.6 with flanged and drilled ends any pattern including necessary jointing and jointing materials complete (with rubber gaskets, bolts and nuts etc) complete all as specified and directed by Engr in charge including taking down the old worn out sluice valve complete all as specified and directed for the following sizes :-
150 mm dia
100 mm dia
80 mm dia
Supply only high strength Calcium Hypochlorite based granular chlorination chemical having 60% to 70% available chlorine granuler must contain appropriate quantities of disinfectants/corrosion inhibitors to prevent encrustation/scaling in distribution, packed in 40/45 Kg plastic Drum. Make :- DECLIBAC TECHNOLOGIES, PURI CHLOR BY RAYALASEEMA, POTTER & WATTS, BRIOZING or equivalent as approved by GE
M&L for Cleaning of underground RCC reserviour(sump) at undermentioned pump house, by draining out stored water completely with mud, pumping out and throwing away manually with buckets and cleaning of inner surface of bottom and walls of sump after removing complete accumulated sludge/mud, dirt etc and scraping all inner surfaces with steel wire brush and finally washing with fresh water two times, disinfecting the reserviour with 2% solution of potassium permanganate, two coat of white wash inside of the sump and two coat of snowcem paint to the out side of the sump including writing date of cleaning with white synthetic enamel paint complete all as specified and directed for the following sizes :- Note : The underground RCC sump shall be cleaned within 24 hrs, till the time contractor shall be made alternate arrangement for supply of water to the troops timely.
180000 Gallons capacity at Tejas main pump House
100000 Gallons capacity at Tejas main pump House
100000 Gallons capacity Semi Underground sump at PH No 7
50000 Gallons capacity at PH No 2 & PH No 7
33000 Gallons capacity at Gurugram Bagh & Guard Room
M&L for Cleaning of RCC overhead reserviour of undermentioned capacities at 21 Metre staging by draining out stored water completely cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/mud, dirt etc with steel wire brush and finally washing with fresh water two times, disinfecting the reserviour with 2% solution of potassium permanganate and two coat of white wash all around surfaces of inside of the OHT including writing date of cleaning with white synthetic enamel paint and removing sludge, scale mud etc. complete all as specified and directed for the following sizes :-
100000 Gallons at PH No 7
50000 Gallons at PH No 2
S&F, in repair, cast iron, water meter, Bulk enclosed Dry Dial type both end flanged, confirming to IS-2373, including rubber gasket joint at both ends for 100mm bore with nuts, bolts & washers and fixed in existing DI pipe line by cutting and providing flange on both side complete all as specified and directed.
Disconnecting, dismantling the defective three phase induction motor 415 Volts 50 Hz of centrifugal pumpset 1440 RPM and re-winding with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material, varnish,bearing, connection plate and all other petty items required to make motor functional and re-assembling the motor including installation, commissioning and testing on full load all as specified and directed. Notes :- (a) Transportation charges from installation to contractor's workshop and back after repair are deemed included in the rate quoted in the item. (b) Cost of nuts, bolts, washers, connection plate, grease lubrication to bearing bushes etc are deemed included in this rate. (c) Old dismantled winding wire will be contractor’s property for which credit shall be affected as per schedule of credit.
For motor of capacity 60 HP
For motor of capacity 40 HP
For motor of capacity 25 HP
For motor of capacity 20 HP
For motor of capacity 10 HP
For motor of capacity 7.5 HP
For motor of capacity 5 HP
For motor of capacity 3 HP
For motor of capacity 2 HP
Disconnecting, dismantling of Centrifugal monoblock pumpset of capacity as following of 1440 RPM and dismantling of defective parts such as Impeller nut , gland , impeller key, gland packing, water deflector, bush bearing sleeve, gaskets, volute stud and nuts , suction and delivery flange and stud and nuts, gland bolts and nuts Gun metal impeller etc and all other petty items required to make pump functional and re-assembling the pump with motor including installation , commission and testing on full load complete all as specified and directed by Engg-in-charge. Notes:- (i) Transportation charges from installation to contractor work shop and back after repair are deemed included in the rate quoted for the above item. (ii) Cost of nuts, bolts, washers,, grease lubrication to bearing bushes etc are deemed included in this rate.
For motor of capacity 60 HP
For motor of capacity 40 HP
For motor of capacity 25 HP
For motor of capacity 20 HP
For motor of capacity 10 HP
For motor of capacity 7.5 HP
For motor of capacity 5 HP
For motor of capacity 3 HP
For motor of capacity 2 HP
S & F in replacement MCB TP 'C' Series of capacity 40 Amp,3 phase, AC complete all as specified and as directed by the Engineer-in-Charge.
S & F in replacement MCB TP 'C' Series of capacity 63 Amp,3 phase, AC complete all as specified and as directed by the Engineer-in-Charge.
S & F in replacement MCB TP 'C' Series of capacity 100 Amp,3 phase, AC complete all as specified and as directed by the Engineer-in-Charge.
S & F in replacement FASD starter suitable for motor of capacity of 15 HP, 3 phase, AC, 415 Volt with single phase preventer Make- L&T or equivalent complete to be fixed in existing LT panel all as specified and as directed by the Engineer-in-Charge.
S & F in replacement FASD starter suitable for motor of capacity of 25 HP, 3 phase, AC, 415 Volt, complete with single phase preventer, Make- L&T or equivalent complete to be fixed in existing LT panel all as specified and as directed by the Engineer-in-Charge.
S & F in replacement FASD starter suitable for motor of capacity of 40 HP, 3 phase, AC, 415 Volt, complete with single phase preventer , Make- L&T or equivalent complete to be fixed in existing LT panel all as specified and as directed by the Engineer-in-Charge.
S & F in replacement FASD starter suitable for motor of capacity of 60 HP, 3 phase, AC, 415 Volt, complete with single phase preventer , Make- L&T or equivalent complete to be fixed in existing LT panel all as specified and as directed by the Engineer-in-Charge.
S & F in replacement FASD starter suitable for motor of capacity of 10 HP, 3 phase, AC, 415 Volt, complete with single phase preventer, Make- L&T or equivalent complete to be fixed in existing LT panel all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement of flat submersible 3 core 6 Sqmm cable PVC insualted, unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
Lifting and lowering submirsible pump motor with the help of machine/ hydra/chain pully block with sufficent manpower including taking submersible cable dismantling and reconnecting the pipe line including replacement of worn out/ rusted/old nuts & bolts, gasket with new proper size . Job includes cutting, welding any rusted pipe and flanges for safe working of submersible pump with motor of capacity UPTO 25 HP Note:- During lifting/lowering of pump motor from borewell if falls in the borewell then contractor will arrange to take out the pump motor without any extra cost.
M&L for CI fittings for flanged pipes upto 150 mm bore ,bends ,cross Tee any type any radius and straight connecting pieces complete all as specified and directed by Engr in charge.
M&L for repairing unserviceable submersible pump to make the pump functional, Servicing of defective submersible pump of following capacity by dismantling the pump & removing unserviceable parts and assemble the pump properly after replacements of unserviceable parts complete all as specified and as directed. Note:- (a) The quoted rates are inclusive of transporting the pump from bore well site to repair work shop & back to site. (b) The quoted rates are inclusive of any spare required including seal, bearing/bush of pump to make the pump functional irrespective of item in this schedule.
For motor of capacity 25 HP
For motor of capacity 15 HP
For motor of capacity 12.5 HP
For motor of capacity 10 HP
For motor of capacity 5 HP
M & L for rewinding of submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried, rewinding the motor using required gauge of super enamelled copper winding wire. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable for the pump of following capacity complete all as specified and directed.
For submerible motor of capacity 25 HP
For submerible motor of capacity 15 HP
For submerible motor of capacity 12.5 HP
For submerible motor of capacity 10 HP
For submerible motor of capacity 5 HP
Supply and fixing in replacement of flat submersible 3 core 10 Sqmm cable PVC insulated unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
S & F in replacement GI Coloumn pipe of bore 50 mm and 6 meter length with flange of size 50 mm dia and 5 mm thick duly screwed as well as welded on both ends , lowering and fixing into the borewell by using nuts, bolts , gasket and washers complete all as specified and diected by Eng-in-charge. Note:- Cost of welding of flange nuts,bolts & gasket is included in the unit rate.
S & F in replacement GI Coloumn pipe of bore 80 mm and 6 meter length with flange of size 80 mm dia 6 mm thick duly screwed as well as welded on both ends , lowering and fixing into the borewell by using nuts, bolts , gasket and washers complete all as specified and diected by Eng-in-charge. Note:- Cost of welding of flange nuts,bolts & gasket is included in the unit rate.
Supply and fixing in replacement of fully automatic star delta starter suitable for 15 HP submersible/monoblock pump motor set AC 440V 50 Hz with single phase preventer over current, short circuit protection built in voltmeter, ammeter complete with sheet metal enclosure including fixing/mounting and dismantling old unservicable all as directed and specified. Make L&T/ BCH/Siemens
Supply and fixing in replacement of fully automatic star delta starter suitable for 25 HP submersible/monoblock pump motor set AC 440V 50 Hz with single phase preventer over current, short circuit protection built in voltmeter, ammeter complete with sheet metal enclosure including fixing/mounting and dismantling old unservicable all as directed and specified. Make L&T/ BCH/Siemens
M&L for rectification of defective run lead joing by burning out lead joint in position including recovering lead and making new lead joint all as specified including bailing out water coming from defective joints by means of electric/diesel driven pump set, testing of the joint under full working pressure for the following CI Pipe lines all as directed by Engineer-in-charge.
200 /150mm dia
100/80 mm dia
M&L for rectification of defective rubber gasket flanged joints including replacing rubber gasket, bolts, nuts and washers for the following CI/MS pipe line.
200/150 mm dia
100/80 mm dia
M/s GANJOO AND CO
Saini Enterprises
PARKASH ENTERPRISES
blue max associates
Ridhi engineers and builders
Goyal Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .