| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.4 L+₹3.4 L (20.3%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹21.0 L+₹4.0 L (23.8%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹22.7 L+₹5.7 L (33.9%)Rejected-Finance | L4 | Rejected-Finance L4 |
Tender Value
₹30.6 L
EMD Value
₹61,300
Closing Date
11 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHISIANA
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (AF), BHISIANA, PIN-151201
Repair/Replacement/Maint of LT Distribution system alongwith allied Works in Tech Area at AF Stn Bhisiana
2021_MES_412633_1
GE/BHI-41/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) BHISIANA
Please Refer Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) BHISIANA
₹61,300
Yes
25 Feb 2021
14 Jan 2021
13 Feb 2021
14 Jan 2021
11 Feb 2021
28 Jan 2021
60 days
Amount
Dismantling/disconnection of LT connections from ACB by taking down proper shutdown, opening the ACB (Panel) installed at various locations for servicing, overhauling all moving contacts, fixed contacts, tripping coil including testing the insulation value of moving and fixed contacts and cleaning the carbon from contact point with petrol etc and greasing oiling the all moving parts including testing all meters/relay such as under voltage relay and servicing,shut trip coil etc including reassembling the ACB and testing after completion of work all as directed by Engr-in-Charge. Note : Complete servicing and maintenance will be carried out at site only
M & L for scrapping/cleaning of outer surfaces (with scrapper and wire brush) of Voltage Stablizer/Isolation Transformer and spray painting the finished surface with two coats of best quality synthetic enamel paint over one coat of red oxide primer complete including writing of MES No all as directed by Engineer-in-Charge upto 400 KVA capacity transformer of any Make/Shape/Size.
Material and labour for preparation of old steel surfaces including welding work of doors of panels/feeder piller/Jn box, hinges with locking arrangement and applying one coat of synthetic enamel ivory paint/(Smoke grey) to steel LT Panel/bus bar box and junction boxes surface after disconnecting the electrical connections and reconnecting LT cables after painting, complete as specified and directed by Engr-in-Charge.
S&F steel tubular swaged pole including taking down for steel tubular swaged poles type 410-SP-31 (09 mtr long) with mild steel base plate of size 30cmx30cmx6mm thick, welded at bottom and cap finial taper plugs, bolt, nuts and screw as specified and fixed in true vertical position complete. Note :- (a) Excavation earth work, foundation concrete shall be measured and paid separately under respective items. (b) Poles shall be painted with two coats of black bituminous paint throughout internally and externally up to planting depth. The remaining portion of the exterior surface shall be painted with two coats of aluminium paint over a coat of red oxide primer.
M&L for PCC 1:4:8 Type D2 using 40mm graded aggregate for base foundation complete all as specified and directed by Engr in Charge.
M&L for PCC (1:3:6) type C-1 with 20 mm gradded stone aggregate for copping of poles Pedestal (PCC) or complete all as specified and directed by Engr in Charge.
M&L for stretching the ACSR conductors from the poles of any size/type, with the help of T&P, taking all safety precautions complete all as specified & directed by Engr-in-Charge.
M&L for Trimming the trees branches from OH line upto 3 mtrs including cleaning the site and removing of tree branches from site complete all as directed by Engr-in-Charge.
S&F PVC line separator for LT OH line suitable for 3 phase of capacity 1100 volts complete all as directed by Engr-in-Charge.
Supply and fix in replacement danger notice board/plate of 1.6mm thick mild steel sheet vitreous enameled white with letter, figures and conventional skull and bones in signal red colour and fixed with MS clamps, nuts and bolts of approved size of HT 25 x 20 cm size.
Supply and fix in replacement for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 32x6 mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type C-1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting book made out of 6mm dia bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as directed.
M&L for taking down unserviceable LT UG cable any type from trenches and removing the fault and relaying of LT UG cable after rectifing the fault including relaying and making cable in serviceable condition of 1100 V grade UG cable of size from 185 to 240 Sqmm, 3½ core. Note : (a) Striaght throuigh joints measure and paid seaprately. (b) Excavation, Returning, filling, removal, sand cushioning & brick protection will be measured and paid separately.
M&L for taking down unserviceable LT UG cable any type from trenches and removing the fault and relaying of LT UG cable after rectifing the fault including relaying and making cable in serviceable condition of 1100 V grade UG cable of size from 70 to120 sq mm, 3½ core. Note : (a) Striaght throuigh joints measure and paid seaprately. (b) Excavation, Returning, filling, removal, sand cushioning & brick protection will be measured and paid separately.
M&L for taking down unserviceable LT UG cable any type from trenches and removing the fault and relaying of LT UG cable after rectifing the fault, including relaying and making cable in serviceable condition of 1100 V grade UG cable of size from10 to 50 sq mm, 2 to 4 core. Note : (a) Striaght throuigh joints measure and paid seaprately. (b) Excavation, Returning, filling, removal, sand cushioning will be measured and paid separately.
Excavation in trenches not exc. 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sqm on plan and getting out in soft/loose soil.
Returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25 cm as directed.
Removing excavated material (soil) n.exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for providing Fazilka River sand as in sand cushioning to under ground cable including punning down of sand in layers as specified and as directed.
M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed.
M&L for removal and relaying of old bricks recover against item No. 12, 13 & 14 and after rectifying the fault of UG cables complete all as specified.
M&L for making bore below the road for crossing the 100mm dia GI pipe for cable protection and fill the putty on both sides of the GI pipe after crossing the armoured cable to avoid the water inside complete all as specified and directed by Engr-in-Charge.
All as per item No 21 above but GI pipe dia 80mm.
All as per item No. 21 but GI pipe dia 50mm.
M&L for galvanized steel tubing 100 mm dia medium garde (ISI marked) for protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
All as per item No.24 above but having size 80 mm.
All as per item No. 24 above but having size 50 mm.
Taking down LT cable 1100 Volts grade heavy duty UG cable XLPE/PVC of size from 120 sqmm, 3½ core.
Taking down LT cable 1100 Volts grade heavy duty UG cable XLPE/PVC of size from 70 to 95sq mm, 3½ core.
Taking down LT cable 1100 Volts grade heavy duty UG cable XLPE/PVC of size from 25sqmm 4 core.
Supply , laying, jointing and testing XLPE insulated screened armoured heavy duty electric cable with aluminium Conductor 1100 volts grade of size 25 Sq mm 4 Core with aluminum thimble of same size complete all as directed.
Supply , laying, jointing and testing XLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 Sq mm 3.5 Core with aluminum thimble of same size complete all as directed.
Supply, laying, jointing and testing XLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 Sq mm 3.5 Core with aluminum thimble of same size complete all as directed.
Supply, laying, jointing and testing XLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 120 Sq mm 3.5 Core with aluminum thimble of same size complete all as directed.
S&F Single core insulated multi stranded copper conductor cable unsheathed 1100 Volts 2.5 Sqmm complete all as specified and directed by Engr in charge .
Supply and Fix PVC Sintex Box (200mm x250mm) having 04 Nos of aluminium Bus Bar mounted on insulator with the help of nut, bolts, clamps including single pole MCB of 6 Amps, 2.5 sqmm copper conductors cable 3 core for connection of incoming and outgoing cables complete all as specified and directed by Engineer-in-Charge.
M& L for time light Switches of Capacity 65 Amps digitial timer box with contactor rating 65 Amp TP, Digital timer and MCB 65 Amp TPN, out door type, mounted on GI angle iron frameof size 25x25x4mm grouted in cement concrete, including necessary excavation and earth work, connection of LT UG cable complete all as specified and directed by Engr-in-Charge.
M&L for Cable jointing Kit for 1100 Volts Grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 sqmm, Indoor/Outdoor type complete all as directed at site.
All As per Item No. 37 above but for cable of size 70 & 95 Sqmm.
All as per Item No. 37 above but for cable of size 120 Sqmm.
Supply and fixing in replacement of Aluminium Thimble of size:-
S&F in replacement of MCCB 400 Amps, 4 Pole 36 KA with adjustable thermal & magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
S&F in replacement of MCCB 315 Amps, 4 Pole 36KA with adjustable thermal and magnetic setting settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 250 Amps, 4 Pole 25 KA with adjustable thermal settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 200 Amps, 4 Pole 25 KA with adjustable thermal settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 160 Amps, 4 Pole 25 KA with adjustable thermal settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 125 Amps, 4 Pole 25 KA with adjustable thermal settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
Material and labour for preparation of old steel surfaces including and applying alternatively in yellow and black one coat of synthetic enamel black paint to steel tabular, pole upto 1 mtr height from ground level and remaining with two coats aluminium paint to LT pole including numbering of pole with black paint complete as specified and directed by Engr-in-Charge.
M&L for checking of earth resistance on monthly basis for each earthing with the help of earth resistance tester, taking earthing result along with the user rep and proper record shall be made by the concerned JE E/M and one skilled tradesmen and one helper deputed by the contractor alongwith travelling convenyance for the tradesmen, including minor repairs (no new items) deemed inclusive in the quoted rates at both technical and domestic area at Bhisiana AF Station and checking and balancing of electrical loads of Bldgs in Technical area of all DBs and LT Panesl by diconnecting the incoming and outgoing cables and connections of these cables with the help of thimble as per site requirement, dressing of wires inside of DBs with the help of cable tie including closing of LT Panels and DBs doors with the help of nuts and bolts including welding drilling etc deemed inclusive in the quoated rates complete all as specided and directed by Engr-in-Charge. Note: Penalty shall be imposed for each job @ Rs50/- for delyaing the checking of earthing within the one day for one earth complete all as directed by the Engr-in-Charge.
DIAMOND SALES COROPORATION
M/s Luxmi Constructions
Rasvinderpalandco
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .