Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC 368 PHASE 4 SAS NAGAR MOHALI 160059 PB | MOHALI | SAS NAGAR | PUNJAB | 160059 | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹22.9 L+₹1.9 L (9.29%)Rejected-AOC 96 SECTOR 16 A CHANDIGARH 160015 | CHANDIGARH | CHANDIGARH | 160015 | L2 | Rejected-AOC Quoted L2 | |
| 3 | L3₹23.7 L+₹2.8 L (13.3%)Rejected-AOC BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L3 | Rejected-AOC Quoted L3 |
Tender Value
₹24.8 L
EMD Value
₹49,660
Closing Date
7 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) Chandigarh
GE(AF) Chandigarh PIN-160003 C/o 56APO
PROVN OF CERTAIN INFRASTRUCTURE AT AF STATION CHANDIGARH UNDER GE (AF) CHANDIGARH
2023_MES_594444_1
GE(AF)/CHD/T-07/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Chandigarh
All as per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹49,660
Yes
7 Jul 2023
10 May 2023
13 Jun 2023
10 May 2023
7 Jun 2023
24 May 2023
10 May 2023 - 17 May 2023
Amount
Surface excavation n. exc. 30cm deep and averaging 15cm deep and getting out soft/ loose soil all as specified and directed.
Excavation in trenches in soft/ loose soil n. exc. 1.5m deep and n. exc. 1.5m wide for foundations, laying pipe line, cable etc. or n. exc. 10sqm on plan for shafts, wells, cesspits, manholes, pier holes etc. and getting out complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25cm thick with soils complete all as specified and directed.
Removing excavated soil n. exc. 50m and depositing where directed at a level n. exc. 1.50m above the starting point complete all as specified and directed.
Removing excavated soils exc. 500m but n. exc. 1.5 KM and depositing where directed complete all as specified and directed.
Sand filling under floors or in foundations in 25cm thick layers including watering and consolidation complete all as specified and directed.
Excavating in post holes (or similar holes) in soft/ loose soil each n. exc. 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm complete all as specified and directed.
M&L for hardcore of broken stone of gauge not exceeding 63mm, deposited, spread and leveled in layers not exceeding 15cm thick, watering and ramming to a true surface complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using mechanically crushed stone aggregate as in foundations, filling and mass concrete etc. complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using mechanically crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L for providing cement concrete (1:2:4) type B-1 using mechanically crushed stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed.
M&L for RCC (1:1½:3) type B-1 using mechanically crushed stone aggregate as in foundations, including rafts, footings, plinth beam etc. complete all as specified and directed.
M&L for RCC (1:1½:3) type B-1 using mechanically crushed stone aggregate as in columns, pillars, posts etc. complete all as specified and directed.
M&L for RCC (1:1½:3) type B-1 using mechanically crushed stone aggregate as in beams, roof beams, lintels exceeding 1.5m span complete all as specified and directed.
M&L for RCC (1:1½:3) type B-1 using mechanically crushed stone aggregate as in slabs supported on walls, beams & columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 using graded mechanically crushed stone aggregate for hold fast blocks, including necessary form work for rough finished surfaces etc complete all as specified.
Supply only integral water proofing compound.
M&L brickwork with sub class 'B' bricks straight or curved on plan exc. 6m mean radius, built in cement mortar (1:4) complete all as specified and directed.
M&L brickwork with sub class 'B' bricks straight or curved on plan to any radius as in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for rough finished surface of concrete complete all as specified and directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions etc. for rough finished surface of concrete complete all as specified and directed.
Use and waste of form work to sides and soffits of lintel & lintel beams for rough finished surface of concrete including supports, overhangs etc. complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surface of concrete complete all as specified and directed.
Supply and fixing, stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to steel frames with tinned tacks or galvanized wire staples or fixed to wooden frames with first class hard wood beads complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over cut to length bend to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.90mm dia complete all as specified and directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D complete all as specified and directed.
S&F push pull or manual type steel rolling shutters 1.25mm thick without ball bearing including top cover, anchoring rod, hasp and staple and treated with one shop coat of red oxide primer including erected in position as indicated complete all as specified and directed.
S&F factory made steel windows with side hung shutter including box type hinges, steel handles (fabricated of Z-section 100mm long & welded/ riveted to shutter in lieu of locking handle), steel peg stay, 2 Nos. tower bolts on each leaf duly welded, with glazing bars, complete all as specified and directed.
S&F factory made steel windows with side hung shutter including box type hinges, steel handles (fabricated of Z-section 100mm long & welded/ riveted to shutter in lieu of locking handle), steel peg stay, 2 No. tower bolts on each leaf duly welded, without glazing bars, including flat iron 12 x 3mm for securing wire mesh complete all as specified and directed.
S&F ornamental and intricate design framed work in grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F mild steel round bars 10mm dia, MS flats etc. to be fixed as strengthening/ Tie bars for chain link fencing conforming to Fe-290 Gde E-165 complete all as specified and directed.
Supply only MS galvanised chain fencing, any size or type (4mm dia galvanised steel wire of mesh size 100mm x 100mm, fixed to MS post by means of screw to flat iron) complete all as specified and directed. Note: - Flat iron shall be measured and paid vide item No. 32.00 here-in before.
S&F rolled mild steel roof trusses (framed), trussed purlins, crane gantries, rails & fastenings & heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Gde Fe 410-W (Gde-E-250) quality-A complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour as approved having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F 1.6mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
S&F mild steel screw bolts (machine made) 10mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut of length exc. 5cm but n. exc. 10cm complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on fair face of brick work or concrete surfaces of walls finished even and fair complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surface in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:4) on ceiling finished fair and even all as specified and directed.
M&L for 100mm thick plain cement concrete (1:4:8) type D-2 using graded mechanically crushed stone aggregate in sub base of flooring all as specified and directed.
M&L for 40mm thick PCC (1:2;4) type B-1 using mechanically crushed stone aggregates as in path, floors etc. and finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 50mm thick PCC (1:3:6) type C-1 using mechanically crushed stone aggregate laid in alternative as in plinth protection including finished the surface fir and even & complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
M&L for 20-25mm thick machine cut Kota stone slab as in flooring, steps of stair (treads), set with neat grey cement slurry, laid over and including 20mm thick cement and sand mortar (1:6) screed bed/ bedding layer, jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
M&L for including preparation of new plastered or un-plastered surface of walls and applying two coats of cement base paint complete all as specified and directed.
M&L for preparation of new plastered surfaces on walls and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and directed.
M&L preparation of new or previously untreated surface of brick/ concrete of any description, not otherwise described over 10cm width or girth and applying two coats of plastic emulsion paint over a coat of priming paint plaster coat complete all as specified and directed.
M&L for preparation of new plastered surface of ceiling and applying two coats of oil bond distemper over a coat of chalk whitening complete all as specified and directed.
M&L preparation of new steel surfaces of any description not otherwise described over 10cm girth or width and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F glass dividing strips, 3mm thick inserted in position, conform to design, and width of strips is 38mm complete all as specified and directed.
M&L for point wiring complete with single core multi stranded Copper conductor cable of size 1.5 sqmm PVC insulated FRLS unsheathed 1100 volt grade in and including non metallic PVC conduit of size 19mm dia or higher including Tee, junction, bends etc concealed in wall/ fixed on ceiling and including MS modular boxes of suitable size for housing modular switches, sockets etc including 1.5 sqmm green PVC insulated wire for earth continuity for one light/ fan/ exhaust fan complete.
M&L for point wiring complete with single core multi stranded Copper conductor cable of size 1.5 sqmm PVC insulated FRLS unsheathed 1100 volt grade in and including steel conduit of size 19mm dia or higher including Tee, junction, bends etc concealed in wall/ fixed on ceiling and including MS modular boxes of suitable size for housing modular switches, sockets etc including 1.5 sqmm green PVC insulated wire for earth continuity complete:-
One light/ fan/ exhaust fan point controlled by one way switch
One three pin 5 amp socket outlet multipurpose on independent board
One three pin 5 Amp switch socket cum on same board.
All as per item No. 56.00 above but with 2.5 sqmm cable insulated for 3 pin 15 amp multipurpose outlet including 2.5 sqmm PVC insulated copper wire for earth continuity on independent board complete.
S&F switch flame proof rotary type with termination box in LM6, 16A, single pole 250V all as specified and directed.
S&F flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P plus earth complete all as specified and directed.
S&F exhaust fan, flameproof steel body AC single Phase, 230V of size 380m sweep with, blades and frame and louvers complete all as specified and directed.
S&F wiring for circuit/ submain wiring along with earth wire with two single core 2 x 4 Sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper FRLS conductor in and including PVC concealed conduit including one run of continuous PVC insulated FR copper multi stranded copper cable of size 1 x 4 Sqmm earth wire for earth continuity conductor complete all as specified and directed. Note: Two runs of 4.0 Sqmm multistranded cable and one run of 4.0 Sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
S&F switch piano, flush type, single pole, one way, 5 Amps, 230 volts all as specified and directed.
S&F socket outlet, 2 in 1, 5 Amps, 230 volts flush type all as specified and directed.
S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and directed.
Supply, fix, connecting and testing MCB single pole (MCB SP), 6 to 32Amps, 240 volts of rupturing capacity 10kA, C curve type complete all as specified and directed.
Supply, fix, connecting and testing MCB SPN, 40 to 63 Amps, 240 V of rupturing capacity 10kA, C curve type complete all as specified and directed.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, SPN, 8 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
S&F LED light fitting 1 x 16 watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S&F LED lights fitting 1 x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cm × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR (Part-I) duly connected to earthing test point all as specified or indicated including necessary excavation and earth work in any type of soil, 20mm bore medium grade GI pipe for watering, 40mm dia medium grade GI protection pipe, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1 reinforced XPM of weight not less than 4 Kg Sqm and testing on completion complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to using galvanised iron strip 25mm × 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including necessary excavation and earth work in any type of soil, 20mm bore medium grade GI pipe for watering, 40mm dia medium grade GI protection pipe, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1 reinforced XPM of weight not less than 4 Kg Sqm and testing on completion complete all as specified and directed.
Supply, fix, commissioning and testing BEE 5 star rated 2 TR hi wall split unit indoor & outdoor unit complete including making hole for passing copper pipes and drain pipe with copper pipe from indoor to outdoor, copper wound compressor of suitable size including stand for outdoor unit and extra copper pipe as per site requirement with insulation on pipe with cordless remote control and inbuilt air ionizer and plasma filter for better indoor air quality complete all as specified and directed. Make: HITACHI/ DAIKIN/ O-GENERAL/ CARRIER.
S&F 5 KVA capacity voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and directed. Make: V-Guard model No. AULTEN 5 KVA 4000W 150V-280V Heavy duty or equivalent from AE, APLAB, ANDREW YULE, VOLINA.
S&F rigid non-metallic PVC conduit 25mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and directed.
Supply and laying galvanized iron tubing 50mm bore light grade with all fitting laid in trenches, fixed on wall/ floor etc all as specified and directed.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding techique and necessary machine including HDPE pipe of up to 150mm dia suitable for 0.4 mpa working pressure all as specified and directed.
Supply, laying in trenches clean dry sand to required width and depth at bottom and top of cable including spreading, levelling, punning for laying/ cushioning of cable all as specified and directed. Note: Punned thickness only will be considered or payment.
Supply and laying burnt bricks, old size, sub class 'B', laid flat abutting each other, perpendicular to cable with width equal to width of brick laid in trenches for protection of cable all as specified and directed.
Supply, fixing, connecting, testing and commissioning of LT cubical panel of size 1000mm x 800mm x 400mm, factory made, compartment type, dust and vermin proof (IP-55) outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15mm thick (14 SWG) CRCA Sheet duly powder coated and grouted with 50mm x 50mm x 6mm angle iron frame, 120cm long angle iron legs on PCC foundation with cement concrete PCC (1:2:4) and front & rear double door type inclusive locking arrangement & two coat of supper enameled first grade quality over red oxide primer with provision of all incoming/ outgoing cable entries along with hanging provision, suitable size of double compression type cable gland for incoming & out going cable marking of cable with marked MCCB of Bldg all as specified and comprising the following:-
Anil Kumar Gupta
L-7 Primewave Communications
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .