11845-IRUMPANAM TERMINAL
CIVIL WORKS AT IPS1 STATION
22000040-HD-11845
22000040-HD-11845
Open Tender
Unknown (Unspecified Location)
₹0
₹70,000
3 Mar 2023
21 Feb 2023
3 Mar 2023
3 Mar 2023
21 Feb 2023 - 3 Mar 2023
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | SPLY AND LAYG OF PCC 1:2:4 | SPLY AND LAYG OF PCC 1:2:4 — PROVIDING AND LAYING PLAIN CEMENT CONCRETE OF FOLLOWING GRADE WITH 20MM AND DOWN SIZE GRADED AGGREGATES FOR BED BLOCK FOR BRICK WALLS, FOUNDATIONS, FLOORS, APRONS, PITS, DRAINS& ANY OTHER CONCRETING WORK AS PER HPCL REQUIREMENT INCLUDING ANY REQUIRED SHUTTERING, MACHINE MIXING, TAMPING, RAMMING, CURING, ETC ALL COMPLETE AT ALL LEVELS AS PER SPECIFICATIONS, DRAWINGS, JOB PROCEDURES ETC AND INSTRUCTIONS OF HPCL ENGINEER-IN-CHARGE. PCC 1:4:8 In addition to above, The scope includes PCC in foundations, footings, retaining walls, slabs, pavements etc. Proportions for preparing PCC for all ingredients shall be calculated as volumes.All the material used in the works shall confirm to the specifications as described in the technical specifications and scope of job. | - | Cubic Meters |
| 2 | SPLY CONST OF BRICK | SPLY CONST OF BRICK — PROVIDING AND CONSTRUCTING FIRST CLASS BRICK MASONRY IN SUB STRUCTURE AND SUPER STRUCTURE FOR ALL DEPTH AND HEIGHT, INCLUDING SCAFFOLDING, CURING ETC. (EXCLUDING PLASTER) COMPLETE AS PER SPECIFICATIONS, DRAWINGS AND AS DIRECTED BY HPCL EIC. BRICKS TOBE USED OF MINIMUM CRUSHING STRENGTH 35 KG/CM2. CEMENT SHALL BE EITHER 43 GRADE OPC OR PPC FLY ASH BASED OF HPCL APPROVED MAKE. 230 MM THICK IN CM 1:6 Supply and providing burnt brick masonry work in cement mortar 1:4 with approved quality 3rd class bricks (Compressive Strength lies between 35 - 70 kg/cm2 and absorption between 22-25%) including transportation of bricks to site, supply of all materials for the job, Labour, water, curing etc., of specified thickness, all complete as per the specifications and instruction of Engineer in charge. | - | Cubic Meters |
| 3 | CHIPPING /DISMANTLING | CHIPPING /DISMANTLING — DISMANTLING OF STONE/BRICK MASONRY/RCC/PCC WORK, ALL TYPES OF EXISTING FLOORING, SLAB TARFELT LAYERS ETC. AT ALL HEIGHTS / DEPTHS, SORTING OUT SERVICEABLE AND UNSERVICEABLE MATERIALS, STACKING THEM SEPARATELY WITHIN A LEAD OF 50 M INCLUDING ALL LABOR, TOOLS FOR DISMANTLING ETC., COMPLETE. | - | Cubic Meters |
| 4 | PROVIDING 20 MM OF | PROVIDING 20 MM OF — PROVIDING 20 MM THICK EXTERNAL SPONGE FINISH CEMENT PLASTER 1:4 (1 CEMENT : 4 SAND) AS PER ARCHITECTURAL SHAPES MARKED IN THE DRAWINGS, AT ALL DEPTHS AND HEIGHTS IN TWO COATS OF 12MM AND 8MM. 2ND COATING 8MM SHALL BE FINISHED WITH SAND FACED PLASTERING ON FACES OF WALLS, PILLARS, PROJECTION, BANDS, CORNICES, FINS, SILLS, KERB WALLS OF COMPRESSOR SHED, DG SHEDS ETC., INCLUDING RAKING OUT JOINTS IF ANY LEFT OUT, NECESSARY DABBING, CURING, SCAFFOLDING, PROVIDING CHICKEN MESH AT JUNCTIONS OF COLUMNS, BEAMS ETC., COMPLETE AT ALL HEIGHTS AS PER SPECIFICATION AND DRAWINGS, SECOND LAYER WITH WATER PROOFING COMPOUND | - | Square Meters |
| 5 | PROVIDING EXT. WATER | PROVIDING EXT. WATER — HEAVY DUTY REINFORCED ACRYLIC WATER PROOF COATING FOR TERRACE NEEDS TO BE CARRIED OUT AS PER THE TECHNICAL SPECIFICATIONS OF THIS TENDER. WORK INCLUDES SUPPLY AS WELL WEATHER PROOFING WORK UNDER GUIDANCE OF ASIAN PAINTS/DR.FIXIT PERSONNEL. Please ignore auto genearted . Plastering to be carried out on Roof top of Substation, Control room and Guest House as required by using dense mortar, which is cohesive and had waterproofing properties. To get good bonding between new & old plaster surface, an elastomeric liquid shall be used. Surface Preparation: Roof surfaces to be cleaned thoroughly. Loose particles/Old loose felt to be removed from Gutters (all sides of roof), adjoining parapet walls and roof extension areas etc. complete. No dust or No major undulations shall be ensured over the prepared surface. Earth, grass, plants and debris if any found are to be removed and entire area cleaned before laying of membrane. Scope also to include removal of existing treatment or tiles, prepare the surface suitable for taking new treatment. Sloped surfaces to be prepared with CM 1:4 Mix for receiving the new treatment. Shifting all debris to un-objectionable areas as instructed by Engineer in charge Party should quote their rates by considering dismantling of existing treatment where ever necessary on the terrace of these Buildings.Heavy Duty Rein forced Acrylic Water Proof Coating for Terrace needs to be carried out. Heavy duty terrace waterproof coating system should be composed of specially developed highly elastic & resilient acrylic polymers, properly selected & graded fillers, lightfast & weather durable pigments, micro-fibres, additives & best quality fungicidal in water medium. Three-layer system with coats in different colours ensuring proper build-up of the thickness, making it a reliable waterproofing system. Dry film thickness of 1 to 1.25 mm after three coat application must be achieved. Crack bridging - Bridging of cracks up to 2 mm width. Material should have higher tensile strength, tear resistance & bond strength with cementations substrates. Coating should be form highly elastic & resilient coating so helps to withstand the structural movements. Coating should be Resistant to UV & weather conditions. Coating should be Abrasion resistant - No additional protective coating is required for roof subjected to foot traffic. Substrate should be non-toxic in nature Drying time between each coat should be 6 to 8 hrs and curing for 7 days. Seven days after application of weather coat, it should be checked for its adhesion to the substrate by marking a square of 5 cm x 5 cm, for every 200 sq. m of the area. Thickness of the dry film will be checked with the help of Vernier-Callipers. Conduct ponding test by filling water up to 50 mm height for 48 hours to ensure leak-free terrace. All corners, gaps, joints, protrusions & outlets shall be coated with two extra coats. Full proof waterproofing of parapet walls also needs to be carried out. Fibre mesh that is embedded or sandwiched between the coats. Fibre mesh to be installed after the first Coat only. Vendor has to supply water proofing material of Asian Paints (APL) & Dr. Fixit (DFL) make only. Vendor has to carry work in strict technical supervision under water proofing expert from Asian Paints or Dr. Fixit only. The Contractor needs to carries out application as per Membrane data sheet or as recommended by Asian Paints (APL) & Dr. Fixit (DFL). The application of the Membrane should be subject to satisfactory pre-inspection and post inspection by the representative authorized by APL/DFL and when installed in accordance with the technical specifications provided by APL/DFL. | - | Square Feet |
| 6 | HIRING OF JCB | HIRING OF JCB — PROVIDING & OPERATION OF JCB FOR MISCELLANEOUS JOBS ON RENT BASIS, AS & WHEN ADVISED BY HPCL. PAYMENT TO BE MADE ON PER HOUR BASIS. | - | Hour |
| 7 | MANUAL EXCAVATION | MANUAL EXCAVATION — MANUAL EXCAVATION: MANUAL EXCAVATION IN ALL TYPES OF SOIL EXCEPT SOFT ROCK AND HARD ROCK INCLUDING OBSERVING ALL NECESSARY PRECAUTIONS, TOOLS, TACKLES, DEWATERING, MANPOWER ETC, ALL COMPLETE AS PER INSTRUCTIONS OF SITE ENGINEER. THE EXCAVATED SOIL IS TO BE STACKED IN HEAPS AT A DISTANCE OF AT LEAST 1M OR THE DEPTH OF THE TRENCH, WHICHEVER IS GREATER, FROM THE EDGE OF THE TRENCH.BACK FILLING: BACK FILLING WITH SOIL FROM HEAPS OBTAINED DURING EXCAVATION INCLUDING SPREADING IN LAYERS NOT EXCEEDING 200 MM, WATERING, IF REQUIRED MANUAL COMPACTING BY RAMMING ETC, ALL COMPLETE AS PER INSTRUCTIONS OF SITE ENGINEER. | - | Cubic Meters |
| 8 | SPLYAND PAINTING OF | SPLYAND PAINTING OF — PROVIDING AND APPLYING 2 OR MORE COATS OF ENAMEL PAINT OF APPROVED MAKE OVER ONE COAT OF APPROVED PRIMER WITH NECESSARY SCAFFOLDING/LADDER, SURFACE PREPARATION, SCRAPPING, SAND PAPERING AS DIRECTED FOR PLASTERED, STEEL, WOODEN SURFACE. RATE TO BE APPLICABLE TO ALL HEIGHTS AND LEVELS, SURFACES AND TEXTURES AND CLEANING PAINT SPOT AFTER COMPLETION OF THE JOB. Please ignore auto generated : Providing two coats of primer and two Coats of Exterior Grade Emulsion paint subjected to the dilution specified by manufacturer. Paint shall be having VOC (Volatile Organic Compound) content not more than 50 grams / lit of approved shade to metallice structures, pipings & Fire water lines as & when required as per manufacturers specifications & as directed by Engineer In Charge | - | Square Meters |
| 9 | SPLY AND APLY OF PAINTING | SPLY AND APLY OF PAINTING — INTERIOR PAINTINGSCOPE OF JOB: SUPPLY, PROVIDING AND APPLYING TWO COATS OF FIRST QUALITY INTERIOR GRADE ACRYLIC EMULSION PAINT (OF REPUTED MAKE) INCLUDING SURFACE PREPARATION FOR THE INTERIOR SURFACES OF OLD TELECOM BUILDING, METERING ROOM, BATTERY ROOM AND STORE. THE SCOPE ALSO INCLUDES SUPPLY OF ALL RELATED MATERIALS, MANPOWER, BRUSHES, MIXING TOOLS, TACKLES ETC. SECOND COAT SHALL BE APPLIED AFTER COMPLETELY DRYING OF THE FIRST COAT, AS DIRECTED BY HPCL SITE ENGINEER. Please ignore auto generated . Providing two coats of primer and two Coats of Exterior Grade Emulsion paint subjected to the dilution specified by manufacturer. Paint shall be having VOC (Volatile Organic Compound) content not more than 50 grams / lit of approved shade to all external surfaces including scaffolding, preparation of the plaster surfaces as per paint manufacturers requirements, crack filling with approved filler material, curing etc. complete as per manufacturers specifications & as directed by Engineer In Charge | - | Square Meters |
| 10 | SPLY AND APLY OF PAINTING | SPLY AND APLY OF PAINTING — INTERIOR PAINTINGSCOPE OF JOB: SUPPLY, PROVIDING AND APPLYING TWO COATS OF FIRST QUALITY INTERIOR GRADE ACRYLIC EMULSION PAINT (OF REPUTED MAKE) INCLUDING SURFACE PREPARATION FOR THE INTERIOR SURFACES OF OLD TELECOM BUILDING, METERING ROOM, BATTERY ROOM AND STORE. THE SCOPE ALSO INCLUDES SUPPLY OF ALL RELATED MATERIALS, MANPOWER, BRUSHES, MIXING TOOLS, TACKLES ETC. SECOND COAT SHALL BE APPLIED AFTER COMPLETELY DRYING OF THE FIRST COAT, AS DIRECTED BY HPCL SITE ENGINEER. Please ignore auto generated . Providing two coats of primer and one Coat of Interior Grade Emulsion paint subjected to the dilution specified by manufacturer in VVSPL - IPS1. Paint shall be plastic acrylic emulsion paint having VOC (Volatile organic compound) content not more than 50 grams / lit of approved colour and shade to internal surfaces including making up all the holes and cracks including staging, scaffolding, etc. all complete as specified and directed by the Engineer in Charge | - | Square Meters |