Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹12.7 LAccepted-AOC | L-1 | Accepted-AOC Tender accepted due to lowest and quoted reasonable rates | |
| 2 | L-2₹16.4 L+₹3.7 L (28.8%)Rejected-Finance R O SKERBUCHAN TEH KHALTSI LEH LADAKH 194106 | LEH LADAKH | LADAKH | 194106 | L-2 | Rejected-Finance Higher side quoted amount |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
3 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Khumbathang
CWE Khumbathang
REPAIR/MAINT OF EXTERNAL WATER SUPPLY NETWORK AND OTHER ALLIED WKS AT LAMAYURU, KHALTSI, HANUTHANG, ACHINATHANG, BATALIK, AND BIAMAH IN THE AOR OF AGE BR-II KHALTSI UNDER GE KHUMBATHANG
2022_MES_556301_1
80051/99/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Khaltsi
As per tender and NIT doc
8 documents required · 8 mandatory
₹500
GE Khumbathang
₹36,000
23 Nov 2022
7 Oct 2022
4 Nov 2022
7 Oct 2022
3 Nov 2022
21 Oct 2022
Amount
Excavation in trenches exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point.
Returning, filling including spreading leveling watering and well ramming in layers not exceeding 25mm in any type of soil complete all as specified and directed.
M&L for Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I. (Note:-Punned thickness shall be measured and paid)
Supply and laying un reinforced precast concrete cable cover class LV, type I, flat, size 250 mm x 150 mm x 40 mm complete all as specified.
Supply, laying and testing in repair GI tubing 20mm dia galvanized medium grade laid in trenches including all necessary fittings clamps etc complete and connecting to existing system incl taking down old pipe complete all as specified and directed.
All as per Srl item No.6 here-in-before but 25mm dia pipe
All as per Srl item No.6 here-in-before but 40mm dia pipe
All as per Srl item No.6 here-in-before but 50mm dia pipe
All as per Srl item No.6 here-in-before but 80mm dia pipe
Supply, laying and testing in repair GI tubing 15mm dia galvanized medium grade fixed to walls and ceilings or laid in floors including all necessary fittings clamps etc complete and connecting to existing system incl taking down old pipe complete all as specified and directed.
All as per Srl item No.11 here-in-before but 20mm dia pipe
All as per Srl item No.11 here-in-before but 25mm dia pipe
M&L for construction of block masonary (size of block 20cmx10cmx10cm) valve pit of size 600mmx600mmx600mm (internal dimensions of chamber) , by providing 10cm thick foundation concrete in PCC 1:3:6(M-10, nominal mix) and using with one brick thick wall in CM 1:6 including plastering internally 15 mm thick in CM 1:6 and flush pointed externally as the work proceed in the same maotar complete with 3.15 mm thick MS sheet cover, angle iron frame of grade Fe-310-O or Fe-410-O using (40x40x6mm) handle, locking arrangment, earth work in any type of soil including returning, filling and removal of surplaus soil to a distance not exc. 50 mtr and painting to cover with to coats of synthetic enamal paint over a coat of red oxide on steel surface injcluding preparation of surface all as specified and as directed.
All as per Srl item No.14 here-in-before but valve pit of size 450mmx450mmx450mm (internal dimensions of chamber)
S&F in repair Ball brass valves 20mm bore, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
S&F in repair Gun-metal, globe or gate valves, 50mm bore with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
All as per Srl item No.17 here-in-before but for 40mm dia pipe
All as per Srl item No.17 here-in-before but for 25mm dia pipe
All as per Srl item No.17 here-in-before but for 20mm dia pipe
S&F in repair CI sluice valves 80mm bore with flanged ends operating wheel and brass spindle class PN-1.6 including rubber or fibre board gasket, MS nut and bolts 16 mm dia of suitable length complete all as specdified and as directed.
S&F in repair CI sluice valves 50mm bore with flanged ends operating wheel and brass spindle class PN-1.6 including rubber or fibre board gasket, MS nut and bolts 16 mm dia of suitable length complete all as specdified and as directed.
M&L for Lagging to 25mm bore pipes used in water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 provided with chicken mesh wire netting 25 gauge, 20mm mesh with 0.01mm aluminium foil
All as per Srl item No.23 here-in-before but for 20mm bore pipe
Taking down, disconnecting carefully and transportation to workshop for repair of electric submersible motor of size 02 HP to 12.5 HP, 415 volts 50 Hz, 3 phase. Complete all as specified and as directed.
M&L for rewinding, servicing and testing of 415 volts 50 Hz, 01 HP to 02 HP submersible motor, and re-fixing, connecting in existing position, the minor parts i.e. nut, bolts, washers etc. to be included in servicing cost Complete all as specified and as directed.
M&L for rewinding, servicing and testing of 415 volts 50 Hz, 03 HP to 05 HP submersible motor, and re-fixing, connecting in existing position, the minor parts i.e. nut, bolts, washers etc. to be included in servicing cost Complete all as specified and as directed.
M&L for rewinding, servicing and testing of 415 volts 50 Hz, 10 HP to 12.5 HP submersible motor, and re-fixing, connecting in existing position, the minor parts i.e. nut, bolts, washers etc. to be included in servicing cost Complete all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to galvanized earth strip of size 32mmX6mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, strip protected by dia 40 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggregate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result complete including taking out of existing earthing all as specified.
All as per Srl item No.29 here-in-before but using galvanised earth lead wire 4.0mm dia.
S&F in replacement MCCB 160 Amps,4 pole, 415 volts, 36 KA rupture capacity with release adjustable thermal & fixed magnetic setting complete all as specified and as directed.
S&F in replacement MCCB 100 Amps,4 pole, 415 volts, 25 KA rupture capacity with release adjustable thermal & fixed magnetic setting complete all as specified and as directed.
S&F in repair exhaust fan, steel body, AC single phase, 230 V of size 300 mm sweep with blades and frame and louvers.
S&F in repair 3 layer PP-R Polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV of 25 mm bore stablished and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass thereaded polypropylene random fittings to be laid in trenches/wall/floor complete all as specified and directed. Note all connected fittings like elbow,tee,reducer coupler will be count in RM
S&F in repair Changeover switch on load of capacity 200 Amps, 415 volt, 4 pole, with metal enclosure box, including replacement of incoming and outgoing cable connectiones with aluminium conductor cable, lugs, nuts ,bolts etc.
S&F in repair Changeover switch on load of capacity 125 Amps, 415 volt, 4 pole, with metal enclosure box, including replacement of incoming and outgoing cable connectiones with aluminium conductor cable, lugs, nuts ,bolts etc.
S&F in repair submersible flat black pvc cable of size 2.5 Sq.mm, 4 core copper conductor as per IS 694. complete all as specified and as directed.
Supplying and laying in replacement synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
S&F in replacement of DOL starter MK-1, 5 HP for submersible motor, 415 volts, 50 Hz, 3 phase, complete all as specified and directed.
Supply , laying , connecting & testing in repair XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 70 sq. mm 3.5 core incl taking down old cable complete all as specified and directed.
All as per Srl item No.40 here-in-before but cross sectional area 50 sq. mm 3.5 core
All as per Srl item No.40 here-in-before but cross sectional area 35 sq. mm 3.5 core
All as per Srl item No.40 here-in-before but cross sectional area 25 sq. mm 3.5 core
All as per Srl item No.40 here-in-before but cross sectional area 16 sq. mm 4 core
M&L for cleaning the under ground water storage tank (inside surfaces only) of capacity 50000 Ltrs by scraping, scrubbing (without damaging the tank surfaces) with coir brushes and removing all deposits/scales, algae formations, silt/other sticky or foreign materials from adhering tank surfaces and washing inside surfaces of tank with approved bleaching powder solution and finally recleaning with fresh plain water to remove any trace of bleaching powder all as specified and directed by Engr in charge. Note: Item rate includes necessary disconnection and reconnection of pipelines before and after cleaning of the tank where required.
Supply, installation, commissioning and testing of LT feeder piller box of size 900x1200x300 mm, indoor cubical type, floor mounted, CPRI approved vermin proof factory made of CRCA Sheet 3.15 mm thick and MS angle of size 50x50x6mm having suitable legs, 2 ft long, grouted on PCC foundation of hight not less than 30 cm from the ground level, both side openable with locking and key arrangement with two Nos pad lock 50 mm make Godrej/Harison, powder coated with three phase, 415 volts, 50 Hz, AC supply all as directed by Engr-in-Charge and comprising of the following:-
Deduct Credit for Demolished/Dismantled material Rs (-) 41,220.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
SONAM ANGCHOK
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .