Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 5 1351 MARKANDEYA NAGAR EAR GAJULARAMARAM ROAD HYDERABAD RANGAREDDI TELANGANA 500055 | MEDCHAL MALKAJGIRI | TELANGANA | 500055 | Accepted-Technical Bidder meets eligibility criteria |
Tender Value
₹2.2 L
EMD Value
₹4,323
Closing Date
2 Mar 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(EP-MM) BEZH
O/o Sr. Chief Engineer (Electrical) BSNL Electrical Zone, Room no- 601, 6th Floor, BSNL Bhavan, Adarsh Nagar, Hyderabad
Renovation EI and fans, rewiring of point wiring, Circuit wiring providing light fitting, ceiling fans, exhaust fans, kitchen chimney at IQ suites and IQ kitchen at Chikkadpally
2026_BSNL_267953_1
96/EE(EP-MM)/CEE/BEZH/ 2025-26 dated 19.02.2026
Open Tender
Electrical Works
Item Rate
60 days
Hyderabad
Please refer Tender documents.
14 documents required · 14 mandatory
₹590
AO (Cash), BSNL, office of CGMT, Telangana Circle
₹4,323
8 Apr 2026
19 Feb 2026
3 Mar 2026
19 Feb 2026
2 Mar 2026
19 Feb 2026
19 Feb 2026 - 26 Feb 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer (EP-MM), % Sr. CE (E), BEZ, Hyderabad.
Name of Work: Renovation EI & fans, rewiring of point wiring, Circuit wiring providing light fitting, ceiling fans, exhaust fans, kitchen chimney at IQ suites and IQ kitchen at Chikkadpally.
NIT No: 96/EE(EP-MM)/CEE/BEZH/ 2025-26 dated 19.02.2026
Name of the Bidder/ Bidding Firm / Company :
Sl. No. DESCRIPTION OF ITEM Item Code / Make Qty Unit Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Basic unit price exclusive of all taxes & Charges FF Packing % FF Packing Amount CGST % CGST Amount SGST% SGST Amount IGST % IGST Amount All-inclusive Unit Cost (5+7)+[(9+11) or 13] Total price inclusive of all charges (3 x 14) Amount of Input tax Credit (ITC) to be availed [(9+11) or 13] Total Amount of Input tax Credit (ITC) to be availed (3 x 16) Unit price excluding ITC amount (net unit cost) (14-16) Total price inclusive of all levies and charges but excluding ITC (net total cost) HSN for goods and SAC for services
###0;###0 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel /PVC conduit including dismantling as required. (a) Group B 111 22 pts Excess(+) Full Conversion INR
###0;###0 Supplying and fixing 20/18W 4' LED Patti type fitting suitable for operation on 240V, 50Hz, AC supplying including interconnections, testing etc., as reqd. 112 8 Nos Excess(+) Full Conversion INR
###0;###0 Supplying and fixing 9/10W 2' LED Patti type fitting suitable for operation on 240V, 50Hz, AC supplying including interconnections, testing etc., as reqd. 113 4 Nos Excess(+) Full Conversion INR
###0;###0 Supplying and fixing 9/10W Fancy type LED fitting suitable for operation on 240V, 50Hz, AC supplying including interconnections, testing etc., as reqd. 114 4 Nos Excess(+) Full Conversion INR
###0;###0 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B. 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019). THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 115 4 Nos Excess(+) Full Conversion INR
###0;###0 Supplying and fixing of 8" dia exhaust fan of plastic body suitable for operation on 240V, 50Hz, AC supplying including providing and fixing louvers, interconnections, testing etc., as required.. M/s Havells Ventil Air DX or similar superior make. 116 4 Nos Excess(+) Full Conversion INR
###0;###0 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 2x1.5 sq.mm + 1x1.5 sq.mm earth wire. 117 50 Mtrs Excess(+) Full Conversion INR
###0;###0 b) 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 118 50 Mtrs Excess(+) Full Conversion INR
###0;###0 c) 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 119 40 Mtrs Excess(+) Full Conversion INR
###0;###0 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16A modular socket outlet and 15/16A modular switch, connections etc., as reqd 120 8 Nos Excess(+) Full Conversion INR
###0;###0 Supplying and fixing of 3 pole 32 Amps Power Contactor with 1no NO auxiliary contactor suitable for operation on 415V, 50Hz, AC supply, in a suitable MS Enclosure including interconnections, testing, etc., as required. ( For Controlling the Split AC unit and Geyser with Door Key card switch) 121 4 Jobs Excess(+) Full Conversion INR
###0;###0 Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc., as required. a) 5/6 A Switch 122 46 Nos Excess(+) Full Conversion INR
###0;###0 b) 3 pin 5/6 A Socket Outlet 123 14 Nos Excess(+) Full Conversion INR
###0;###0 c) Neon Indication lamp Red Modular M/s Anchor Roma or SS make 124 14 Nos Excess(+) Full Conversion INR
###0;###0 d) 32A DP Main switch with key ring tag M/s Anchor Roma or SS make 125 4 Nos Excess(+) Full Conversion INR
###0;###0 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plat etc., as required. 126 4 Nos Excess(+) Full Conversion INR
###0;###0 Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches in recess etc., as required. a) 8 Module (125mm x 125mm) 127 6 Nos Excess(+) Full Conversion INR
###0;###0 b) 12 Module (200mm x 150mm) 128 5 Nos Excess(+) Full Conversion INR
###0;###0 Supplying and fixing of 90cm 1350m3/hr filter less auto clean kitchen chimney with touch/motion sensor operation suitable for operation on 240V, 50Hz, AC supplying including providing exhaust Aluminium pipe, interconnections, testing etc., as required. M/s Elica or ss make 129 1 Job Excess(+) Full Conversion INR
###0;###0 Supplying and fixing of15 Litres storage type water heating Geyser, the tank made up of Copper material with High temperature cut off suitable for operation on 240V, 50Hz, AC supplying including interconnections, testing etc., as required. 130 4 Jobs Excess(+) Full Conversion INR
###0;###0 Providing and fixinig of circular type 12W LED light fitting (LED Downlighter) having luminous flux 1125 lumens minimum suitable for ceiling mounting as reqd. (M/s Crompton smart Linea/ SS make) 131 9 Nos Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select, Excess (+), Less (-)
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.32 MB
BOQ_311705.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .