Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.4 L+₹2.6 L (16.3%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹19.5 L+₹3.7 L (23.6%)Rejected-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹23.3 L+₹7.5 L (47.3%)Rejected-AOC | L4 | Rejected-AOC Other than L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
24 Sept 2020, 6:00 pmClosed
Shri TKM Rambhal, EE
GE (West) Mathura Pin-281001
Repair/Maint of heating appliances like Geyser and solar water heater under GE (W) Mathura
2020_MES_372809_1
8300/959/E8
Open Tender
Civil Works
Item Rate
335 days
Mathura Cantt
As per tender documents
9 documents required · 9 mandatory
₹500
GE (West) Mathura
₹50,000
Yes
12 Oct 2020
28 Aug 2020
25 Sept 2020
28 Aug 2020
24 Sept 2020
12 Sept 2020
Amount
M&L for attending daily complaints in repairs and maintenance of geysers, solar water heater lodged by the users complete to make serviciable condition with skilled electrician (Geyser & solar water heater) at Mathura Cantt and obtaining signature from users complete all as directed at site by Engineer-in-charge. Note:- (a) The minor complaints (non functioning of geyser, replacement of thermostate, indicators, flexible wire, bib cock, stop cock, PVC connections, plug top, MCB, Socket, ) should be competed within 24 Hrs by deploying required manpower. (b) Major complaints like leakage of tank relocation of geyser, glass wool replacement, assembly replacement should be completed within 48 Hrs. (c) The rates quoted for the item shall be deemed to include the cost of labour for replacement of any stores whenever required. The materials will be measured and paid as supply only under relevant items of this schedule. (d) Contractor fails to attend the complaints of normal nature within 24 Hrs and urgent nature within 2 hrs he shall be lavied penalty of Rs 500/- per complaint per day. (e) Nature of complaints either urgent or normal shall be decided by the Engineer-in-charge. (f) Contractor either himself or his accredited agent shall collect the day to day complaint slip from concern JE in the morning daily and deposit the same after complaince.
Dismantling of Storage water heater of any capacity, any make from walls for servicing by opening base plate assembly and de-scaling of inner tank, inlet outlet piping, including tightning of all electrical connections from socket/ MCB/ DB to heating element, setting of thermostate (temp setting should not be more than 70 degree centigrade) water connections from inlet to outlet including hot water tap and testing complete all as specified & directed. Note:- Replacement of heating element, Assembly, unserviciable inner tank will be measured & paid separately.
Supply only Heating element 1.5KW as per sample triangle three net base for geyser complete all as specified and directed.
Supply only Heating element 1.5KW as per sample circle type push/ thread model for geyser complete all as specified and directed.
Supply only Heating element 1.5KW as per sample majesty type for geyser complete all as specified and directed.
Supply only Heating element 1.5KW as per sample banana bend type for geyser complete all as specified and directed.
Supply only Heating element 2.0KW as per sample banana bend type for geyser complete all as specified and directed.
Supply only Heating element 2.0 KW for geyser as per sample complete all as specified and directed.
Supply only themostate suitable for 25/50 liters geysers complete all as specified and directed.
Supply only indicating bulbs red & green complete set suitable for 25/50 liters geysers complete all as specified and directed.
M&L for in replacement of glass wool complete all as specified and directed.
Supply only plug Top 20 Amps complete all as specified and directed. Make : Anchor/ Havells/ Legrand
M&L for in replacement of steel tank made out off sheet steel electric welded of capacity 25 liters including gasket, mounting bolts complete all as specified and directed.
M&L for in replacement steel tank made out off sheet steel electric welded of capacity 50 liters including gasket, mounting bolts complete all as specified and directed.
M&L Base plate assembly made out of steel/ copper base with steel tubes for fixing thermostate and element with heavy duty suitable for 25/50ltrs electric water heater complete all as specified and directed.
Supply and fixing hold fastner for fixing of geyser 25/50 liters capcity including nuts and washers complete all as specified and directed.
Supply only PVC insulated copper conductor 1100 volts grade circular cable of size 2.5 sqmm (50/.025) 3 core complete all as specified and directed.
Supply only single pole and neutral enclouser with a two pin and earth plug and socket complete with DBOXx MCB 25A protected power unit complete all as specified and directed. Make- Havells Cat Part DHDUCDP0253016-25 or equivalent make- Legrand/Phillips.
Supply only socket 03 pin 16 Amps complete all as specified and directed.
Supply only switch flush type polycorbonate body, single pole, one way 16 Amp complete all as specified and directed.
Supply only 15mm bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified and directed. (Minimum weight 15mm- 90gms/20mm- 125gms).
Supply only PVC Connections with steel reinforced for hot and cold water circulation 300mm long with nuts and washers of size 15mm dia complete all as specified and directed.
Supply only PVC Connections with steel reinforced for hot and cold water circulation 600mm long with nuts and washers of size 15mm dia complete all as specified and directed.
M&L for Laying of GI tubing medium grade on floors/walls/roof including all necessary fittings of size 15mm dia including taking down old complete all as specified and directed.
M&L for hot water pipe duly insulated with glass wool and aluminium cladding 25mm bore with weather proof joints and fixing with clamps for connection from hot water storage tank to pipe connection to bath/kitchen complete all as specified and directed.
M&L for Laying of GI tubing medium grade on floors/walls/roof including all necessary fittings of size 20mm dia including taking down old complete all as specified and directed.
M&L for laying of CPVC pipe as per IS : 15778 tubing SDR11 on floors/walls/roof including all necessary fittings of size 25mm dia including taking down old complete all as specified and directed.
S&F in repair male Brass threaded adopter of 20mm dia complete all as specified and directed.
M&L for in replacement of assembly bottom cover (Inspection cover) split type made of iron sheet duly painted with two coats of synthetic enemel paint over a one coat of red oxide primer complete all as specified and directed.
M&L for in replacement of bottom cover for outer body made out of MS sheet of same guage and size duly painted with two coats of synthetic enamel paint of existing geyser colour over a one coat of red-oxide primer complete all as specified and directed.
M&L for replacement of Solar Plate Evacuated Tube Collector for 100 ltr capacity and fixing new Solar plate with all new steel nut bolts of suitable size, replacement of gasket of all flange joints, replacement of hot water to hot water tank complete all as specified and directed.
M&L for replacement of Solar Flat Plate Collector for 100 ltr capacity and fixing new Solar plate with all new steel nut bolts of suitable size, replacement of gasket of all flange joints, replacement of hot water to hot water tank complete all as specified and directed.
M&L for replacement of Solar Flat Plate Collector for 200 ltr capacity and fixing new Solar plate with all new steel nut bolts of suitable size, replacement of gasket of all flange joints, replacement of hot water to hot water tank complete all as specified and directed.
M&L for replacement of Solar Plate Evacuated Tube Collector for 200 ltr capacity and fixing new Solar plate with all new steel nut bolts of suitable size, replacement of gasket of all flange joints, replacement of hot water to hot water tank complete all as specified and directed.
M&L for replacement of Solar Flat Plate Collector for 300 ltr capacity and fixing new Solar plate with all new steel nut bolts of suitable size, replacement of gasket of all flange joints, replacement of hot water to hot water tank complete all as specified and directed.
M&L for replacement of Solar Flat Plate Collector for 500 ltr capacity and fixing new Solar plate with all new steel nut bolts of suitable size, replacement of gasket of all flange joints, replacement of hot water to hot water tank complete all as specified and directed.
M&L for replacement of Solar Plate Evacuated Tube Collector for 500 ltr capacity and fixing new Solar plate with all new steel nut bolts of suitable size, replacement of gasket of all flange joints, replacement of hot water to hot water tank complete all as specified and directed.
Supply only heating element 3.0 KW single phase for Solar Water Heater complete all as specified and directed.
M&L for laying XLPE isulated cable armoured 1100 volts grade, cross sectional area 10sqmm 2 core aluminum conductor on wall / floors including taking down old complete all as specified and directed.
Taking down of ceiling fan 1200/1400 mm of any make & capacity from any height and removing its blades keep aside and refixing the same after repair/ overhauling/rewinding complete all as specified and directed.
All as per item No 40.00 (here- in -bofore) but exhaust fans of sweep 450/375/300/230mm complete all as specified and directed.
M&L for rewinding of ceiling fan motor size 1200/1400mm sweep with super enamelled copper conductor of suitable size, meet to original specification & speed including varnishing, heating etc including taking out old copper wire before rewinding complete all as specified and directed.
M&L for metal filling on shaft, grainding, including rewinding ceiling fan of motor size 1200/1400mm sweep with super enamelled copper conductor of suitable size, meet to original specification & speed including varnishing, heating etc including taking out old copper wire before rewinding complete all as specified and directed.
M&L for metal filling on shaft, grainding, including rewinding exhuat fan of motor size 230/275/300/375mm sweep with super enamelled copper conductor of suitable size, meet to original specification & speed including varnishing, heating etc including taking out old copper wire before rewinding complete all as specified and directed.
M&L for rewinding of exhaust fan/wall mounting fan motor size 380/450 mm sweep with super enamelled copper conductor of suitable size, meet to original specification & speed including varnishing, heating etc including taking out old copper wire before rewinding complete all as specified and directed.
All as per Items No 45.00 (here-in before) but of size 230/300mm sweep complete all as specified and directed.
Supply only ball bearing of suitable size (6201/6202/6203) Make -SKF/TATA/NBC complete all as specified and directed.
Supply only bush of suitable size complete all as specified and directed.
Supply only capacitor 2.5 Mfd 230 Volts complete all as specified and directed.
Supply only capacitor 4.0 Mfd 230 Volts complete all as specified and directed. Make: Asian/Universal/Epcos.
S&F down rod made out of 19/20 mm bore MS pipe of long 45 cm including making hole threading etc. complete all as specified and directed.
S&F MS clamp including rubber real complete all as specified and directed.
S&F in repair fan regulator 200w socket type 3 speed electronic type complete all as specified and directed.
S&F fan blade for exhaust fan upto 300 sweeps complete all as specified and directed.
S&F fan blade for exhaust fan 300mm to 450mm sweep complete all as specified and directed.
S&F louvers madeout of sheet metal and mild steel frame suitable for exaust fan 230/300mm sweep complete with nut bolts etc as per existing size including grouting to wall etc complete all as specified and directed.
S&F MS Frame suitable for exhaust fan of 225/300 mm sweep complete with 4 No legs for fixing complete all as specified and directed.
S&F MS Frame suitable for exhaust fan of 350/450 mm sweep complete with 4 No legs for fixing complete all as specified and directed.
S&F solar water heater tank of capacity 100 litres as per existing size and shape duly insulated as per company norms complete all as specified and directed.
S&F solar water heater tank of capacity 200 litres as per existing size and shape duly insulated as per company norms complete all as specified and directed.
S&F solar water heater tank of capacity 300 litres as per existing size and shape duly insulated as per company norms complete all as specified and directed.
S&F solar water heater tank of capacity 500 litres as per existing size and shape duly insulated as per company norms complete all as specified and directed.
S&F evacuater glass tube as per existing size and shape complete all as specified and directed.
RAJ CONSTRUCTIONS
shyam construction
S M TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .