Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC KARIMPUR NAIHATI BIRBHUM 731243 | BIRBHUM | WEST BENGAL | 731243 | ₹18.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹21.3 LRejected-Finance KARIMPUR NAIHATI BIRBHUM 731243 | BIRBHUM | WEST BENGAL | 731243 | ₹21.3 L | L2 | Rejected-Finance L2 |
| 3 | L3₹23.0 LRejected-Finance 60 K N C ROAD NAYAN KANAN BARASAT KOL 700124 | BARASAT | NORTH 24 PARGANAS | WEST BENGAL | 700124 | ₹23.0 L | L3 | Rejected-Finance L3 |
| 4 | L4₹35.1 LRejected-Finance | ₹35.1 L | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | KHAIRUL ALAM L1 | ABDUL SARTAZ L2 | Mr/Messrs. SAHA AND CO. L4 | Kundu Enterprise L3 |
|---|---|---|---|---|---|---|---|
| 1.00Execution of work under following items | |||||||
| 1.01 | Supply, Installation, Testing & Commissioning of Cubicle type totally enclosed free standing type moisture, dust and vermin proof Floor Distribution Panel made out of 2.0 mm thick & front cover 1.6 mm thick CRCA sheet, CT's, internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing including earthling connection arrangement, etc. complete with following equipment:- I. Panel Size: 8.5 Ft * 6 Ft * 14 Inch. II. Phase Indicating lamps-6 Nos. III. 400 Amps. Main Switch Fuse Unit-1 Nos. IV. 415 Amps Changeover Switch-1 Nos. V. 100 Amps SDF TPN- 8 Nos. VI. 63 Amps SDF TPN-7 Nos. VII. 32 Amps. SDF TPN-4 Nos. VIII. 100 Amps. Terminal Poles- 19 Pcs. IX. 500 Amps. Copper BusBar-2 Nos. X. Digital Voltmeter (Tested)-3 Nos. XI. Digital Ammeter (Tested) -3 Nos. XII. and other required materials. Approved Make: L&T or Siemens | 1 | Whole Job | 2,80,000 ₹3.3 L | 2,80,563 ₹3.3 L | 2,60,000 ₹3.1 L | 2,95,000 ₹3.5 L |
| 1.02 | Supply and underground laying of two nos. 120 Sq mm, 4 Core, Armored XLPE Cables in underground trench in single tier formation (horizontal) the trench size: 915 mm x 760 mm average depth with brick protection on the top of each cable with 8 nos. bricks per Mtr. and 4 nos. bricks per Mtr. as separator between every two cables including filling the space between the bricks and cables and also the trench with shifted soil, leveling up and restoring surface duly rammed, including all charges. Approved Make: Havells/Finolex/L&T | 260 | Mtrs | 1,100 ₹3.4 L | 1,330 ₹4.1 L | 2,300 ₹7.1 L | 1,185 ₹3.6 L |
| 1.03 | Supply and underground laying of two 50 Sq mm, 4 Core, Armored XLPE Cables single tier formation (horizontal) the trench size: 915 mm x 760 mm average depth with brick protection on the top of each cable with 8 nos. bricks per Mtr. and 4 nos. bricks per Mtr. as separator between every two cables including filling the space between the bricks and cables and also the trench with shifted soil, leveling up and restoring surface duly rammed, including all charges. Approved Make: Havells/Finolex/L&T | 240 | Mtrs | 500 ₹1.4 L | 715 ₹2.0 L | 1,420 ₹4.0 L | 660 ₹1.9 L |
| 1.04 | Supply and Laying of one 50 Sq mm, 4 Core, Armored XLPE Cables Laying of cable after cutting floor/pavement/wall/ andMaking holes including, embedding the cable at an average depth 100 mm and mending good the damages to original finish, removing the rubbish including all charges. Approved Make: Havells/Finolex/L&T | 330 | Mtrs | 350 ₹1.4 L | 580 ₹2.3 L | 900 ₹3.5 L | 540 ₹2.1 L |
| 1.05 | Supply and Laying of one 35 Sq mm, 4 Core, Armored XLPE Cables in Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth 100mm. and mending good the damages to original finish, removing the rubbish including all charges. Approved Make: Havells/Finolex/L&T | 680 | Mtrs | 385 ₹3.1 L | 470 ₹3.8 L | 665 ₹5.3 L | 450 ₹3.6 L |
| 1.06 | Soil Excavation : Excavation of soil for installation of Earth Electrode and filling & ramming for Morrum Soil | 2 | No. | 301 ₹710.36 | 635 ₹1,498.60 | 4,000 ₹9,440 | 350 ₹826 |
| 1.07 | Earthing Installation: Earthing with 80 mm dia GI pipe (TATA-Medium) x 3.0 Mts.long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts by TATA-Medium GI pipe. | 2 | No. | 2,800 ₹6,608 | 5,985 ₹14,124.60 | 15,000 ₹35,400 | 3,300 ₹7,788 |
| 1.08 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe | 2 | No. | 840 ₹1,982.40 | 1,795 ₹4,236.20 | 4,000 ₹9,440 | 1,000 ₹2,360 |
| 1.09 | Earth Busbar :Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. | 2 | No. | 210 ₹495.60 | 448 ₹1,057.28 | 2,500 ₹5,900 | 255 ₹601.80 |
Tender Value
₹25 L
EMD Value
₹75,000
Closing Date
30 Dec 2025, 10:00 amClosed
The Superintending Archaeologist
2nd Floor, BSNL Administrative Building, Karanajora, Raiganj, West Bengal - 733130
AS PER NIT
2025_ASI_890143_1
10/2025-26/Raiganj
Open Tender
Civil Works
90 days
Cooch Behar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
SA ASI
₹75,000
Yes
7 Feb 2026
16 Dec 2025
31 Dec 2025
17 Dec 2025
30 Dec 2025
17 Dec 2025
Supply, Installation, Testing & Commissioning of Cubicle type totally enclosed free standing type moisture, dust and vermin proof Floor Distribution Panel made out of 2.0 mm thick & front cover 1.6 mm thick CRCA sheet, CT's, internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing including earthling connection arrangement, etc. complete with following equipment:- I. Panel Size: 8.5 Ft * 6 Ft * 14 Inch. II. Phase Indicating lamps-6 Nos. III. 400 Amps. Main Switch Fuse Unit-1 Nos. IV. 415 Amps Changeover Switch-1 Nos. V. 100 Amps SDF TPN- 8 Nos. VI. 63 Amps SDF TPN-7 Nos. VII. 32 Amps. SDF TPN-4 Nos. VIII. 100 Amps. Terminal Poles- 19 Pcs. IX. 500 Amps. Copper BusBar-2 Nos. X. Digital Voltmeter (Tested)-3 Nos. XI. Digital Ammeter (Tested) -3 Nos. XII. and other required materials. Approved Make: L&T or Siemens
Supply and underground laying of two nos. 120 Sq mm, 4 Core, Armored XLPE Cables in underground trench in single tier formation (horizontal) the trench size: 915 mm x 760 mm average depth with brick protection on the top of each cable with 8 nos. bricks per Mtr. and 4 nos. bricks per Mtr. as separator between every two cables including filling the space between the bricks and cables and also the trench with shifted soil, leveling up and restoring surface duly rammed, including all charges. Approved Make: Havells/Finolex/L&T
Supply and underground laying of two 50 Sq mm, 4 Core, Armored XLPE Cables single tier formation (horizontal) the trench size: 915 mm x 760 mm average depth with brick protection on the top of each cable with 8 nos. bricks per Mtr. and 4 nos. bricks per Mtr. as separator between every two cables including filling the space between the bricks and cables and also the trench with shifted soil, leveling up and restoring surface duly rammed, including all charges. Approved Make: Havells/Finolex/L&T
Supply and Laying of one 50 Sq mm, 4 Core, Armored XLPE Cables Laying of cable after cutting floor/pavement/wall/ andMaking holes including, embedding the cable at an average depth 100 mm and mending good the damages to original finish, removing the rubbish including all charges. Approved Make: Havells/Finolex/L&T
Supply and Laying of one 35 Sq mm, 4 Core, Armored XLPE Cables in Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth 100mm. and mending good the damages to original finish, removing the rubbish including all charges. Approved Make: Havells/Finolex/L&T
Soil Excavation : Excavation of soil for installation of Earth Electrode and filling & ramming for Morrum Soil
Earthing Installation: Earthing with 80 mm dia GI pipe (TATA-Medium) x 3.0 Mts.long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts by TATA-Medium GI pipe.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Earth Busbar :Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Earth Continuity Conductor : Connecting the Control Panel to earth busbar including Supply & Fixing G.I. (Hot Dip) Solid GI Wire 4 SWG on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Supply, Installation, Testing and necessary connection of Cubicle type totally enclosed free standing type moisture, dust and vermin proof Sub-Panel Board, of 2.0 mm thick & front cover 1.6 mm thick CRCA sheet, internal wiring with suitable size wires / cable, interconnection, painting complete, Size: 5 Ft. * 2.5 Ft * 1 Ft. including Supplying and fixing of all necessary materials i.e. Phase Indicator Lamp-3 Nos., 100 Amps SDF TPN-1 No., 4 Pole 300 Amps Copper Busbar, double door sheet steel (16SWG), powder coated cable end box for TPNDB horizontal / vertical enclosure with8 Way Double Door TPN, 440 Volts Danger Board, Earning Connection, etc. as required.
Supply, Installation, Testing and necessary connection of Cubicle type totally enclosed free standing type moisture, dust and vermin proof Energy Meter Box of 2.0 mm thick & front cover 1.6 mm thick CRCA sheet, indoor Iron Frame /Angle Iron Frame for fixing of Main Switch, internal wiring with suitable size wires / cable, interconnection, painting complete, etc. Size: 4.5 Ft. * 2 Ft * 1 Ft. including Supplying and fixing of existing one 3 Phase Energy Meter and the following materials i.e. Phase Indicator Lamp-3 Nos., 500 Amps Porcelain Fuse-3 Nos., 400 Amps TPN Main Switch (Rewirwable type)-1 No., Danger Board and others necessary materials i.e. Cable Gland, Cable Socket, Nut, Bolt, Washer including earthling connection arrangement, etc.
Supply & Fixing EI 440 Volts Danger Board for Electrical Control Panel Room, Size: 20 cm x 30 cm (8"x12").
Supply and underground laying of two nos. 4 Sq mm, 1.1 KV three core multi stranded 'FR' PVC insulated Copper Cable in the existing Cable Tench and making necessary connection as required Approved Make: Havells/Finolex/L&T
Supply and underground laying of two nos. 4 Sq mm, 1.1 KV three core multi stranded 'FR' PVC insulated Copper Cables single tier formation (horizontal) the trench size: 915 mm x 760 mm average depth with brick protection on the top of each cable with 8 nos. bricks per Mtr. and 4 nos. bricks per Mtr. as separator between every two cables including filling the space between the bricks and cables and also the trench with shifted soil, leveling up and restoring surface duly rammed, including all charges. Approved Make: Havells/Finolex/L&T
Supply and Installation of Digital auto Battery Charger, Auto and Manual ON-OFF operating Unit.
Supply & Fixing of 150 * 50 * 1.25 mm (50 Pcs.) and 300*50*125mm (100 Pcs.) perforated GI cable tray, Length -2.5 Mtrs Each, reducer with perforation more than 17.5% suspended from ceiling with two nos suspenders & 25x25x3mm angle iron for supporting the reducer including. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required Including Al painting of MS support.
Supply and Installation of Automatic Fire Extinguisher, Capacity: 10 Kg ABC Type.
Supply and Fixing of Ceiling Fan at Electrical Panel Room complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm including painting the rod with approved paint and making necessary connection as required by 2x1.5 sq mm flexible copper wire. Approved Make: Crompton Greaves / Bajaj
Supply and Fixing of 36 W 121 cm LED Tube Light set. Approved Make: Philips/ Syska / Crompton
Supply and Fixing of 415V TPN 8Way Double Door Distribution Box, with one 32 Amps TPN MCB Isolator and 10 nos. MCB (Breaking Capacity 10kA and 16 kA-as required) including necessary connection, Iron Clamp etc. at Electrical Panel Room. Approved Make: L&T or Siemens
200 Watt LED Flood Light-Philips, Model: BVP 184 200, Cool Day Light
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.42 MB
BOQ_935601.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid