| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L1 | Accepted-AOC Found lowest and reasonable | |
| 2 | L2₹35.7 L+₹4.3 L (13.5%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L2 | Rejected-Finance Rejected being not L1 | |
| 3 | L3₹39.8 L+₹8.4 L (26.8%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-Finance Rejected being not L1 | |
| 4 | L4₹39.9 L+₹8.5 L (27.0%)Rejected-Finance | L4 | Rejected-Finance Rejected being not L1 | |
| 5 | L5₹44.7 L+₹13.3 L (42.3%)Rejected-Finance | L5 | Rejected-Finance Rejected being not L1 |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
11 Jul 2024, 6:00 pmClosed
GE (U) Meerut Cantt
Roorkee road Meerut Cantt
REPAIR /REPLACEMENT OF LT PANEL, LT SWITCHGEARS AND ALLIED WORKS IN NORTH AREA UNDER AGE E/M ELECT SUPPLY AT GE(U) MEERUT CANTT
2024_MES_659621_1
8607/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
Yes
₹92,000
Yes
8 Nov 2024
13 Jun 2024
18 Jul 2024
13 Jun 2024
11 Jul 2024
27 Jun 2024
Amount
Taking out unserviceable LT panel any type and size and Supply, installing, testing and commissioning of LT out door type factory made(CPRI Approved ), junction box of size 750mmX600mmX500mm (over all dimension )with mild steel angle iron of size 50X50X6mm vertical frame and legs with mild steel Angel iron 50x50X6 mm in horizontal sides of the frame LT Junction box (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 50x50x6 mm thick angle iron frame work, powder coated finish RAL 7032 SIEMENS GRAY STRUCTURE after the seven tank surface treatment, front & back opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box etc with voltage and danger indicated in Hindi and English complete all as specified and directed. With double door shutter and locking arrangement . Aluminium bus bar of 450 Amps rating with drilled holes for incoming /out going cable core connection including aluminium lugs ,GI bolts ,Nuts and washers of suitable size . Porcelain / synthetic bridge insulators, heavy duty with necessary steel / GI screws ,bolts, nuts and washers -08 Nos , complete all as specified and as directed. , The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25- 150 sqmm by drawing /digging out cable from loops in trenches out side the Bldg. inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board and taking out of old Skelton type panel any type and size complete all as specified and directed by Engr-in-Charge .( Note:-All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test with 4000 Amps at 65 KA, should be submitted by the contractor before executing the job.)
Taking out unserviceable LT panel any type and size and Supply, installing, testing and commissioning of LT out door type factory made(CPRI Approved ), Feeder Pillar Box of size 900mmX600mmX500mm (over all dimension )with mild steel angle iron of size 50X50X6mm vertical frame and legs with mild steel Angel iron 50x50X6 mm in horizontal sides of the frame LT Junction box (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 50x50x6 mm thick angle iron frame work, powder coated finish RAL 7032 SIEMENS GRAY STRUCTURE after the seven tank surface treatment, front & back opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box etc with voltage and danger indicated in Hindi and English complete all as specified and directed. With double door shutter and locking arrangement with in coming MCCB 4 pole, 415 volts AC grade, 250 Amps rating and 25 KA rupturing capacity - 01 No,(Make- ABB/ Schneider / Legrand /L&T/SIEMENS ) Aluminium bus bar of rating 400 Amps with drilled holes for incoming /out going cable core connection including aluminium lugs ,GI bolts ,Nuts and washers of suitable size . Porcelain / synthetic bridge insulators, heavy duty with necessary steel / GI screws ,bolts, nuts and washers , Porcelain and digital MFM V,A,F +PF meter with one set indicator lamb (RYB) (Make- ABB/ Legrand/ Schneider /siemens /LT) complete all as specified and as directed. , Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B’, old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for Junction box. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed .( Note:-All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test with 4000 Amps at 65 KA, should be submitted by the contractor before executing the job.)
Taking out unserviceable LT panel any type and size and Supply, installing, testing and commissioning, factory made and tested . LT feeder pillar box (KIOSK) 1100mm x1100x500mm size, outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 50x50x6mm thick angle iron frame work, powder coated finish RAL 7032 SIEMENS GRAY STRUCTURE after the seven tank surface treatment, front opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) stranded lock with 2 keys, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 1.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25to 150 sqmm by drawing /digging out cable from loops in trenches out side the Bldg. inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size aluminium lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected by cable through suitable size gland plate / glands.& The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint and taking out of old Skelton type panel any type and size complete all as specified and directed by Engr-in-Charge , The scope of work includes the following:- .( Note:-All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test with 4000 Amps at 65 KA, should be submitted by the contractor before executing the job.)
(I) Incoming :-
(i) MCCB 4 Pole, Microprocessor Based 315 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC, protection, -01 Nos along with Spreader terminals .
(ii) Digital MFM V,A,F +PF meter - 01 No
(iii) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
(II) Outgoing :-
(i) MCCB 4 Pole, Thermal Magnetic Based 160 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC, protection, - 4 Nos along with Spreader terminals
(iii) MCB TPN 63 Amp C-Curve - 2 No
Taking out unserviceable LT panel any type and size and Supply, installing, testing and commissioning, factory made LT Panel board minimum size 1200mm x1350x600mm size, outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 600 Amps rating installed on porcelain insulators, The panel shall be dust and vermin proof, IP 56 class protection and made of 3.15 mm CRCA MS sheet and 50x50x6mm thick angle iron frame work, powder coated finish RAL 7032 SIEMENS GRAY STRUCTURE after the seven tank surface treatment, front / back opening type, with aprons for cable entry, and fixing 2 Nos.danger notice plate of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indiated in Hindi and English with double door shutter and locking arrangemen incl The platform shall be such that it is of a height 30 cm above the nearest road level. complete all as specified and directedincluding connections of all out going/in coming existing cables of size 185/240/300 sqmm by drawing /digging out cable from loops in trenches out side the Bldg inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected by cable through suitable size gland plate / glands.& The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint and taking out of old skelton type panel with control switches complete all as specified and as directed Engr-in-Charge .( Note:-All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test with 4000 Amps at 65 KA, should be submitted by the contractor before executing the job.)
(I) Incoming :-
(i) MCCB 4 Pole, Microprocessor Based 400A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC, protection, -02 Nos along with Spreader terminals
(ii) Auto/ Maual type Change over Switch 400 Amps , 415 V, 4 pole , 50 Hz -01 Nos along with Spreader terminals
(iii) Digital MFM V,A,F +PF meter - 02 Nos
(iv) Indicator lamp LED type (R, Y, B) complete with fuse -02 Set
(II) Outgoing :-
(i) MCCB 4 Pole, Thermal Magnetic Based 400A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC, protection, -01 Nos along with Spreader terminals )
(ii) Digital MFM V,A,F +PF meter - 01 No
(iii) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
Taking out unserviceable LT panel any type and size and Supply, installing, testing and commissioning, factory made and tested . LT feeder pillar box (KIOSK) 1100mm x1350x500mm size, outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 600 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 50x50x6mm thick angle iron frame work, powder coated finish RAL 7032 SIEMENS GRAY STRUCTURE after the seven tank surface treatment, front opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) stranded lock with 2 keys, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 1.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 300 sqmm by drawing /digging out cable from loops in trenches out side the Bldg. inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size aluminium lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected by cable through suitable size gland plate / glands.& The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint and taking out of old Skelton type panel any type and size complete all as specified and directed by Engr-in-Charge , The scope of work includes the following:- .( Note:-All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test with 4000 Amps at 65 KA, should be submitted by the contractor before executing the job.)
(I) Incoming :-
(i) MCCB 4 Pole, Microprocessor Based 400A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC, protection, -01 Nos along with Spreader terminals
(ii) Digital MFM V,A,F +PF meter - 01 No
(iii) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
(II) Outgoing :-
(i) MCCB 4 Pole, Thermal Magnetic Based 250 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC, protection, -2 Nos along with Spreader terminals
(ii) MCCB 4 Pole, Thermal Magnetic Based 200A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC, protection, -2 Nos along with Spreader terminals
(iii) MCCB 4 Pole, Thermal Magnetic Based 160A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC, protection, -1 Nos along with Spreader terminals
(iv) MCB TPN 63 Amp C-Curve - 2 No
(iv) Indication Lamp LED type 240 V 50 HZ AC supply (Make BCH / SECURE / L&T) one set of two colour (Red and Green for ON/OFF indication of MCCB) -05 set.
Taking out unserviceable LT panel any type and size and Supply, installing, testing and commissioning, factory made and tested . LT feeder pillar box (KIOSK) 1200mm x1650x600mm size, outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 800 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 50x50x6mm thick angle iron frame work, powder coated finish RAL 7032 SIEMENS GRAY STRUCTURE after the seven tank surface treatment, front opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 1.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 240 sqmm by drawing /digging out cable from loops in trenches out side the Bldg. inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size aluminium lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected by cable through suitable size gland plate / glands.& The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint and taking out of old Skelton type panel any type and size complete all as specified and directed by Engr-in-Charge , The scope of work includes the following:- (Grass mandi) .( Note:-All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test with 4000 Amps at 65 KA, should be submitted by the contractor before executing the job.)
(I) Incoming :-
(i) MCCB 4 Pole, Microprocessor Based 500A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC, protection, -2Nos along with Spreader terminals
(ii) Auto / Manual Change over 4 Pole, 400 Amps rating , 415 V - 1 Nos along with complete accessories terminals
(iii) Ammeter Digital type, CT operated, 0-600A range, (Make- ABB/ Schneider / Legrand /L&T/SIEMENS ) - 02 Set
(v ) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-02 set.
(II) Outgoing :-
(i) MCCB 4 Pole, Thermal Magnetic Based 250 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC, protection, -02 Nos along with Spreader terminals
(ii) MCCB 4 Pole, Thermal Magnetic Based 200 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC, protection, -02 Nos along with Spreader terminals
(iii) MCCB 4 Pole, Thermal Magnetic Based 160A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC, protection, -02 Nos along with Spreader terminals
(iv) Indication Lamp LED type 240 V 50 HZ AC supply (Make BCH / SECURE / L&T) one set of two colour (Red and Green for ON/OFF indication of MCCB) -06 set.
Taking out unserviceable LT panel any type and size and Supply, installing, testing and commissioning, factory made and tested . LT Panel board,box (KIOSK) of size not less than 2400mm x 2150 x 1000mm , outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 1000 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 56 class protection and made of 3.15 mm CRCA MS sheet and 60x60x6mm thick angle iron frame work, powder coated finish RAL 7032 SIEMENS GRAY STRUCTURE after the seven tank surface treatment, front / back opening type, with aprons for cable entry, and fixing 2 Nos.danger notice plate of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest ground level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 400 sqmm by drawing /digging out cable from loops in trenches/ ducts out side the Bldg. inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size Aluminium lugs for terminal connections of cables, necessary PCC foundation with plastering to the Panel board, All out going feeders shall be connected by cable through suitable size gland plate / glands.& The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint and taking out of old Skelton type panel any type and size complete all as specified and directed by Engr-in-Charge , The scope of work includes the following: Items .( Note:-All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test at with 4000 Amps 65 KA, should be submitted by the contractor before executing the job.)
(I) Incoming :-
(i)Air circuit breaker 630Amps, 4 Pole, (thermal magnetic DNI and microprocessor based, 415V, 50Hz, AC supply, Electrical draw out type, having microprocessor based release for over current and earth fault, IS-2516 marked, complete with suitable mutual inter locking arrangements to maintain two different power supply .- 02 Nos.
(iv ) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set.
(II) Outgoing :-
(i) MCCB 4 Pole, TRA 315 Amps, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC, EF protection, -04 Nos along with Spreader terminals
(ii) MCCB 4 Pole,TRA200 Amps, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC,EF protection, -02 Nos along with Spreader terminals
(iii) MCB TPN 63 Amp C-Curve - 2 No
(iv ) Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)-6 set.( for each out going )
Taking out unserviceable LT panel any type and size and Supply, installing, testing and commissioning, factory made and LT feeder pillar box (KIOSK) 1100 mm x 2250 x 600mm size, Indoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 400 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 2 mm CRCA MS sheet and 50x50x6mm thick angle iron frame work, powder coated finish RAL 7032 SIEMENS GRAY STRUCTURE after the seven tank surface treatment, front opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 1.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 16 to 150 sqmm by drawing /digging out cable from loops in trenches out side the Bldg. inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size aluminium lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected by cable through suitable size gland plate / glands.& The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint and taking out of old Skelton type panel any type and size complete all as specified and directed by Engr-in-Charge , The scope of work includes the following:- (Grass mandi) .( Note:-All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test with 4000 Amps at 65 KA, should be submitted by the contractor before executing the job.)
(I) Incoming :-
(i) MCCB 4 Pole, Microprocessor Based 250A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC, protection, -3 Nos along with Spreader terminals
(ii) Auto / Manual Change over 4 Pole, 250 Amps rating , 415 V - 2 Nos along with complete accessories terminals
(v ) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-03 set.
(II) Outgoing :-
(i) MCCB 4 Pole, Thermal Magnetic Based 200 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC, protection, -01 Nos along with Spreader terminals
(ii) MCCB 4 Pole, Thermal Magnetic Based 160 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC, protection, -04 Nos along with Spreader terminals
(iii) MCB TPN 4 Pole, 63A, Breaking capacity C curve , 415 V, 50 Hz -10 Nos
(iii) MCB SPN 2 Pole, 63A, Breaking capacity C curve , 415 V, 50 Hz -5 Nos
M&L for plate earthing for sub station equipment's complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground vertically (in earth pit not less than 3.5 m below normal ground level) with the top edge of the earth plate at a depth not less than 2.75 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of HT/LT equipment's etc at the other, earth strip encased in and including 40mm bore GI light grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate excavation & earth work and RCC cover complete all specified and shown in electrical plate No 5 of SSR Pt-I. incluidng taking out old earthing material complete as directed.
Supply, laying, jointing, testing and commissioning LT underground cables, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098 (marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed. Cables of the following sizes:-(Note;- Rate quoted includes terminal Lugs / road cutting/ wall cutting/ floor cutting and making good damaged portion matching with existing surface with all existing finishes.) incl taking out the existing unserviceable cable any size and type .
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
Relaying laying, jointing, testing and commissioning LT underground cables any type and size laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed. (Note;- Rate quoted includes terminal Lugs / road cutting/ wall cutting/ floor cutting and making good damaged portion matching with existing surface with all existing finishes.) (Note :- Excavation & earthwork, duct work, GI pipe for laying of cable and sand cushioning / cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately under respective items of Sch `A')
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in Soft/Loose soil including trimming sides and bottom of trenches complete all as specified in the following type of soils:
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified in the following type of soils
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables complete all as specified.
M & L Bricks for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm as directed.
Supply and laying galvanised steel water tubing, light grade, IS-1239 marked with all fittings (IS marked) and laid in trenches / under roads / in drains / fixed to poles/walls ( with required size flat iron clamp bolts, nuts and washers ) pipes of the following sizes :-
80 mm bore
100 mm bore
M&L for auguring of hole suitable for passing 40mm to 100mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any damage to existing cables of any type shall be made good by the Bidder without any extra cost to department.
Cutting of worn-out / burnt aluminium cable terminal lugs from the HT/LT cable , crimping of new aluminium cable core and fixing with transformer/ Panel MCCB terminal/ FPB/ JB/ pole/DBs/ stud including cutting/ dressing of cable, disconnecting under ground / OH line cable conductor , cutting down worn-out portion and refixing with suitable lugs complete , including under ground cables of any type and size for repairs including taking out underground cable loop from ground and making connections of restoration of electric supply complete all as specified and directed Engr-in-Charge . Note:- (Excavation, earth work , taking out cable protection covers, and sand cushion and relaying the same shall be deemed included in the unit rate quoted by Contractor)
S&F service main distribution (SMC JUNCTION BOX ) box minimum inside size 395 x 235 x 150 mm with Bus bar 200 amps 4 pole for distribution of multiple no's of service connection, (ISI marked )weather and moisture-proof, nuts and bolted bus bar system, 200 Amps capacity and fixing on pole/wall with suitable FI clamp nuts and bolt including taking out old junction box complete all as specified and directed.
Repair and Replacement of MCCB 4 Pole, TRA 400 Amps, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC, EF protection along with Spreader terminals
Repair and Replacement of MCCB 4 Pole, TRA 315 Amps, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC, EF protection along with Spreader terminals
Repair and Replacement of MCCB 4 Pole,TRA200 Amps, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC,EF protection, along with Spreader terminals
Repair and Replacement of MCCB 4 Pole,TRA160 Amps, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC,EF protection, along with Spreader terminals
Repair and Replacement of MCCB 4 Pole,TRA100 Amps, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC,EF protection, along with Spreader terminals (Make- ABB/ Schneider / Legrand /L&T/SIEMENS )
Repair and Replacement of MCB TPN 63 Amp C-Curve -
Repair and Replacement of Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)
M&L preparation of old painted steel and iron surfaces of any description of panels , not otherwise described ,over 10 cm width or girth and painting one coat with synthetic enamel of approved shade using spray gun including cleaning, stopping and rubbing down and removing all drops etc complete all as specified and directed by Engr -in-Chage
Taking down of existing mild steel/ CRCA shutters of LT panel and repairing the same by welding and providing 100mm long medium weight mild steel hinges and 65mm size pad lock of make Godrej including painting the surfaces to match with existing and making the shutter operations complete all as specified.
S&F 3.15mm thick mild steel/ CRCA steel shutters of LT panel duly fitted with 100mm long mild steel medium weight butt hinges -02 Nos per leaf duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed including dismantling old shutter. (Note:- Superficial area of leaf shall be measured for the purpose of payment)
Taking out cable from MCCB/ bus bar JBs/FPBs/LT panel and burnt terminal removed any size & type and M&L for suitable Aluminium lugs (terminal) fix existing cable incl insulated by insulation tape and fixed Same Panel complete all as specified and directed by Engr -in-Chage Luges (terminal ) of the following sizes:
16 sqmm to 50 Sqmm
70 Sqmm to 95 Sqmm
120 Sqmm to 185 Sqmm
240 Sqmm to 400 Sqmm
PK ENTERPRISES (BID ID -3058284)
Shikha Enterprises (BID ID -3049766)
M/S ROORKEE ENGINEERING (BID ID -3057805)
janta tradrers (BID ID -3050189)
PARADISE INFRA POWER COMPANY (BID ID -3043720)
Jain Traders (BID ID -3048078)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .