Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L1 | Accepted-AOC Contract awarded to M/s Trade Link | |
| 2 | L2₹32.5 L+₹5.8 L (21.7%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹35.3 L+₹8.6 L (32.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹33.0 L
EMD Value
₹66,060
Closing Date
22 Jun 2024, 6:00 pmClosed
GE 860 EWS Karu
GE 860 EWS Karu Pin-194201
PROVN OF 01X BATHROOM AND TOILET BLOCK, 02X URINAL POINTS FOR REZANGLA HALL, 01X GARBAGE BIN, COVERED SHED FOR WASHING PUMP AND AIR COMPRESSOR AND WATER SOCKAGE PIT ALONGWITH PROVN OF HARDSTANDING WITH CHEQUERED TILES IN FRONT OF MANDIR IN VARIOUS U
2024_MES_654838_1
8157/2024-25/E8
Open Tender
Civil Works
Item Rate
270 days
Kiari
As per tender documents
9 documents required · 9 mandatory
₹500
GE 860 EWS Karu
₹66,060
Yes
9 Jul 2024
18 May 2024
24 Jun 2024
18 May 2024
22 Jun 2024
3 Jun 2024
Amount
Surface dressing n.exc 15 cm deep in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Excavating in post holes (or similar holes)each n. exc 0.5 cum, getting out, returning, fillingin and ramming erth pr broken rubble mixed with eart around, in layers not exc 25cm complete all as specified and directed by Engr-in-Charge.
Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for Cement concrete PCC Type D-2 1:4:8(using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete complete all as specified and directed by Engr-in-Charge.
M&L Cement Concrete Type-B1 1:2:4(using 40 mm graded crushed stone aggregate) in foundations,including rafts, footings complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry Type C-1 (1:3:6) using 20 mm graded crushed stone aggregate with solid blocks, exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete in CM 1:4 and finishing the surfaces even and smooth (without using extra cement) as specified and directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and to be finished even and smooth without using extra cement - Internal Plaster complete all as specified and directed.
M&L Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface in broken stone or boulders complete all as specified and directed.
M&L PCC type B-1 1:2:4 (20 mm graded aggregate) for fixing hold fast complete all as specified and directed by Engr-in-Charge.
S&F MS flat iron of size 25x3 mm as in hold fast conforimg to Fe 410-0 or Fe-310-0 complete all as specified and directed by Engr-in-Charge.
M&L PCC type C1 1:3:6 (using 20 mm graded aggregate crushed stone aggregate) 75 mm thick laid in alternate bays (not exc 2 Sqm each) as in Plinth protection finishing even smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed by Engr-in-Charge.
M&L for Cement Concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) 100mm thick as Sub base complete all as specified and directed.
M&L for 40mm thick Cement Concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in floor Sub base complete all as specified and directed.
M&L for coloured non-skid ceramic tiles 7 to 8 mm(square/rectangular) rea of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc 15 mm thick cement mortar screed bed or bedding layer in CM 1:6 complete all as specified and directed by Engr-in-Charge.
M&L for colour glazed ceramic tiles in vertical surface 450 x 350 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing coat of CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for Glazed and skelton Windows, ventilators shutters 30 mm thick 2nd class soft wood, open rebated and prepared to receive glass, guage, etc, divided in to square with plain, chamfered or rounded mitred and rebated sash bars, any numbers, size of members of shutters as specified in SSR Part I Section 8 clause 8.20 (b) as in windows complete all as specified and as directed.
S&F for 2nd Class soft wood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified ans as directed.
M&L for 35mm 2nd class HW plain framed , panelled shutter (two panel) with lock rail and panel of 9mm B.W.P commerical ply or 12mm veneered particle board with commerical veneering on both faces. The size of rail and stile as per IS:1003 complete all as specified ans as directed.
S&F 100mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified.
S&F 150mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified.
S&F 150mm Aluminium handles, cast type, anodised complete all as specified.
S&F 300 mm aluminium alloy anodised sliding door bolt with hasp, staple complete all as specified.
S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engr-in-Charge.
M&L 4 mm thick sheet glass panes ordinary quality and glazing with oil putty in square n .exc 0.50 Sqm in each Pane etc complete all as specified and directed by Engr-in-Charge.
S&F steel work in roof trusses (framed ) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle,channel or flat sections) including distance pieces cleats etc complete all as specified and directed by Engr-in-Charge.
S&F 0.50 mm thick Pre-painted galvalume aluminum zinc coating GI based corrugated in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as directed by Engr-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as directed by Engr-in-Charge.
M&L Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes etc. with riveted, bolted or welded attachment confirming to Fe 410-W (Gde E-250), complete all as directed by Engieer-in-Charge.
Mild steel bolts neck exc 10 mm dia and n exc 15 mm dia, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each scre-wed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long complete all as specified and directed by Engr-in-Charge.
M&L for prepartion of new or prevously untreated wood or wood based surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel painting over a coat of pink primer complete all as specified and directed .
M&L preparation of newly plastered surface of wall of any description and applying two coats of distemper oil emulsion, with one coat of primer all as specified.
M&L preparation of newly plastered surfaces of wall and applying two coats of cement base paint with one coat of primer all as specified.
S&F Rotational moulded water tank 1000 liter polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engr-in-Charge.
S&F 20 mm bore ball valves high pressure PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
S&F vitreous China squatting pan 'orrisa' pattern white colour of size 580x440mm with integral foot rests including provision of lime concrete including P/S traps complete all as specified and directed by Engr-in-Charge.
S&F PVC (Plastic polymer Cistern) low level white flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, brass screws, handle etc and S & F of 32 mm dia PVC flush pipe of suitable length and making all connection complete all as specified and directed.
S&F 15 mm dia bib tap chromium plated with cruth butterfly handle, screw down , screwed for iron pipe or brass ferrule complete all as specified and directed by Engr-in-Charge.
S&F 75 mm dia PVC (SWR) pipe single socketed in any length with rubber ring joints, laid in trenches or fixed to wall complete as spd and directed.
S&F 75 mm dia PVC (SWR) bends any radius complete as spd and directed.
S&F 75 mm dia PVC floor trap , plain with grating including jointing with solvent. as spd and directed.
S&F Wash basins, Vitreous China size 550 x 400mm (flat back or angle back type)any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply including brackets, as spd and directed.
S&F Viterous China urinal, half stall type, white complete including providing and fixing plugs bedding urinal against wall in CM 1:2 securing urinal to plugs with and incl 60mm long brass screws, pointing around urinal back in cement incl 32mm dia PTMT waste coupling, 32mm dia PVC waste pipe and urinal spreader complete all as specified and as directed.
S&F 32 mm bore waste pipe Low density polyet-hylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls,or in floors complete all as specified and directed by Engr-in-Charge.
S&F Pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
S&F Stop valves 15 mm chromium plated fancy type caste copper alloy,screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge.
S&F 20 mm dia 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN-16) UN stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threated polypropylene random fittings laid in trenches etc complete all as specified and directed by Engr-in-Charge.
S&F 15 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engr-in-Charge.
Excavating over areas n.exc 1.5m deep and and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Excavating over areas exc 1.5m deep and n.exc 3.00 m deep and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling mass concrete and similar work complete all as specified and as directed.
M&L for Walling of random rubble uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
M&L for Walling of random rubble stone masonary, uncoursed, well bonded, bedded and solidly hearted, laid dry complete all as specified and directed.
M&L for providing RCC type B-1 1:2:4(Nominal Mix) using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed.
M&L for rough finished Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roof n.exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20 cm wide complete all as specified and directed by Engr-in-Charge.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
M&L TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
M&L for precast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in cover slab for manhole set in CM 1:4 including necessary form work complete all as specified and directed by Engr in Charge.
M&L for Plain cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in coping, benching bed plates and the line including necessary form work and finishing all exposed surface of concrete as per clause 4.11.16.2(a) of SSR Part-I (2009) complete all as specified and directed by Engr-in-Charge.
M&L for loose filling with broken bricks aggregates of gauge 80 to 150 mm in soakage pit, soakage wells complete all as specified and directed by Engr-in-Charge.
S&F 110mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floors complete all as specified.
M&L Concrete bed 1:4:8 type D-2 to drain pipes incl packing under and haunching against the sides of pipes after they are laid and tested bore of pipe in 110 mm complete all as specified and directed by Engr-in-Charge.
Supply only Integral Water proofing compound.
M&L for preparing newly plastered surface and applying two coat of white wash on walls complete all as specified and directed.
S&F Rotational moulded water tank 500 litre polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engr-in-Charge.
S&F 16 mm dia 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN-16) UN stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threated polypropylene random fittings laid in trenches etc complete all as specified and directed by Engr-in-Charge.
M&L for PCC 100 mm thick 1:2:4 type D2 (40 mm graded aggregate) as in floor finishes with smooth surfaces all as specified.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and treating with two coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete 1:3:6 100mm thick type C-2 using 40mm graded stone aggregate over rammed earth as in sub base to receive floor finish etc complete all as specified.
M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors metre with grey cement and pigments including 15 mm thick screed bedding layer CM 1:6 all as specified.
M&L for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges type B1 1:2:4 (using 20mm graded crushed stone aggregate) complete all as specified and directed by Engr-in-Charge.
Returning filling including seprading, levelling watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed by Engr-in-Charge.
M&L for 75mm thick cement concrete type B-1 , 1:2:4 (using 20 mm graded crushed stone aggregate ) as in floor finished surface even and fair using extra cement complete all as specified and direct.
M&L for rendering 15 mm thick internal cement plaster in cement mortar 1:3 on brick or concrete surface etc. on wall finished even smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in coping including necessary form work and set in cement mortar complete all as specified and directed by Engr-in-Charge.
M&L framed work FE-410-W (Gde-250 quality A) as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks complete all as specified and directed by Engr-in-Charge.
M&L 1.00mm thick Mild Steel, Plain sheet in steel Gate cut to size, holes, punched including round heded screws,clout nails or rivits and fixed to steel framing with plain 40mm lap joint with rivited and welded seams . including bending and turning up mitred angles ,ets as required dia galvanised complete all as specified and directed by Engr-in-Charge.
Material and labour for point wiring with 1.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheathed electric cable 1100 volts in and including PVC casing and capping of 25 mm and above (as per conductor run )with all fittings/ accessories and including PVC insulated and unsheathed electric cable 1100 volts1.5 Sqmm ( multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly including 50 mm deep box made of 2nd class hard board of required size and shape etc covered with 3 mm thick plastic laminated sheet ( Make Hylum) for one light point,bell,exhaust point, bulk head, independent controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge.
Description all as per Srl item No. 82.00 here-in-before but for one socket outlet 3 pin, 5 Amps on independent board.
Description all as per Srl item No. 82.00 here-in-before but for one socket outlet 3 pin, 5 Amps on same board.
Description all as per Srl item No. 82.00 here-in-before, but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor (Multi-stranded) insulated and unsheathed electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 1.5 Sqmm copper stranded conductor as continuous earth wire connected to common dolly complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush button single pole one way 5 Amps complete all as specified and directed by Engr-in-Charge.
Supply and fixing socket 2 in 1, 5 Amp, flush type complete all as specified and as directed by Engr-in-charge.
Supply and fixing switch socket combination multi purpose 2 in 1, 3 pin 5A/16A, 5 in 1 flush type complete all as specified and as directed by Engr-in-charge.
Supply and fixing ceiling rose, surface bakelite, 65 x 50 mm, three terminals complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all specified and as directed by the Engineer-in-Charge.
Supply and fix exhaust fan made of study Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by the Engineer-in-Charge.
S&F DB, Single Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.
S&F DB, Single Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.
M&L for sub main wiring with 2 run of 4 Sqmm FR, PVC insulated, unsheathed and stranded copper conductor cable with and incl 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in casing capping, grade, ISI marked, non metallic PVC conduit 15 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original required, complete all as directed.
Supply and fixing MCB single pole and neutral 32 to 40 Amps , 240 volt, 10 KA, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing MCB single pole 6 to 32 Amps, 240 volts, 10 KA complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing new energy saving LED Bulk head fitting 10 watt made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK07 as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified and as directed by Eng-In-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 1991 Part-I and connecting to CBDB’s as specified or indicated including testing on completion .
Supply and laying XLPE insulated, armoured, heavy duty electric cable, with stranded aluminum conductor 1100 V grade nominal cross sectional area 10 Sqmm, 2 core laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-Charge.
Excavation in trenches not exceeding 1.5m and not exceeding 1.5m in depth for laying of electric cable and getting out in any type of soil, complete all as specified and as directed by the Engr-in-Charge.
Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying, streching & testing of cable in trenches complete all as specified and directed by Engr-in-Charge. Note :- Only punned thickness i.e 18cm shall be measured and paid.
M/S ASHRAF HUSSAIN
THINLES OTZER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .