Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹24.9 L+₹4.0 L (19.1%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹25.0 L+₹4.1 L (19.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹25.8 L+₹4.9 L (23.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹26.0 L+₹5.0 L (24.0%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L5 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹67,200
Closing Date
10 Oct 2020, 6:00 pmClosed
GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT
PROVN OF SOLAR WATER HEATER SECURITY LIGHTS LED BLDG SECURITY LIGHTS REPAIR REPLACEMENT OF OLD CONVENTIONAL SECURITY LIGHT ENERGY METER WITH NEW TEMPER PROOF DIGITAL ENERGY METER AND CONNECTED WORKS CERTAIN MINOR REV WKS AT AGE EM OF GE (S) MAMUN
2020_MES_375815_1
GE(S)/M-41/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH MAMUN
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE SOUTH MAMUN
₹67,200
Yes
31 Oct 2020
8 Sept 2020
12 Oct 2020
8 Sept 2020
10 Oct 2020
22 Sept 2020
8 Sept 2020 - 13 Sept 2020
Amount
Taking down security light fitting any type from poles, walls or any other indicated situation/location after disconnecting electrically complete all as specified and directed.
M&L for modular point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire connected to earth dolly including inner and outer frame plate matching with surrouding with modular sunken steel boxes zinc oxide plated of suitable size including modular sheets of suitable module and back plates etc. complete for:- (a) One light/fan/buzzer/3 pin 5 or 6 Amps socket outlet on independent board point controlled by one, one way switch.
S&F switch piano flush button single pole one way 6 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 3 terminals 230 Volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
M&L for in repairs sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
M&L for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
S&F in repairs MCB single pole 230 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables.
S&F in repairs MCB single pole and neutral 240 volts any rating from 32 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables.
S&F in repairs and testing factory made sheet metal enclosure for MCB DB SPN 8 way 240 volt with single door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge.
Supply installation and testing of AC single phase static energy meter of accuracy class 1.00, 240 volt AC, 50Hz, with backlit LED display of rating 10-60 Amps for measure and display KWh, V,I,KW six months history of energy & MD in KW complete including taking out existing unserviceable energy meter and depositing the same in MES store yard complete all as specified and directed. Make-HPL cat part No. SPPB1510000002OC00 or equivalent of any make specified in Appendix 'B'.
Supply and lay in trenches/on wall/on pole/in duct /through protection pipe, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables heavy duty LT cable, 1100 volts grade with aluminium conductor cross sectional area 10 Sqmm 2 core size including retrieving/taking out/taking down old unserviceable cable from duct/trenches/pipes/pole/wall etc. including brick cover and protection pipe and disconnecting the connections. Note :- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
Supply and lay in trenches/on wall/on pole/in duct /through protection pipe, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables heavy duty LT cable, 1100 volts grade with aluminium conductor cross sectional area 25 Sqmm 3.5 core size including retrieving/taking out/taking down old unserviceable cable from duct/trenches/pipes/pole/wall etc. including brick cover and protection pipe and disconnecting the connections. Note :- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point.
M&L for dry clean fine river sand as in sand cushioning to underground cable including punning down of sand layer all as specified and directed. Note :- Punned thickness shall only be measured and paid.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
M&L for galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings, of size 50 mm bore.
Supply, fixing and testing of 60W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete available CCT 5700K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance. LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply, fixing and testing of 45W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete available CCT 5700K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance. LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95.complete all as specified and directed.
Supplying installation and testing of all in one solar street light having in-built solar panel, charge controller, lithium-ion battery, LED light of 24 watts and dusk down sensor alongwith steel tubular sewaged pole 8.5m long with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP 22, including painting with anti corrosive paint internally complete and externally up to painting depth, alternative green & white strips of 30cm width upto 1.5m above ground level, balance length to be painted with two coats of aluminium paint externally including taking out old unserviceable steel tubular pole complete all as specified and directed.
Note for srl item No 19, 20 & 21 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70. 4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be > 100 Lm/W. 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type. 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. 11. CA No. shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintenance required, if any can be carried out from Top cover.
Supply and connecting single core FRLS PVC insulated copper stranded cable of size 1.5 Sqmm for street lights/flood lights passing through pole holes/GI pipe/PVC conduit to junction box and connected electricallu including taking down old unsv wire any type and make complete all as specified and directed.
M&L for painting of PCC pole without removing accessories with two coats of alternative green and white strips of 30cm each upto 1.5m height using synthetic enamel paint. marking the pole number with black synthetic enamel paint over yellow circle of dia 100mm. Painting the steel parts i.e clamps, channels etc by applying two coats of alumn paint all as required at site, complete all as specified and directed.
Supply, installation, commissioning and testing of totally enclosed outdoor type LT Panel in replacement weldless cubical Kiosk in modular bolted construction type dust and vermin proof floor mounted type (IP-65 degree of protection ) made out of 3 mm thick CRCA sheet of recommended size.All sheet metal parts separately chemically treated with 7 tank treatment process. The panel having both side opening door with locking arrangement.all doors fixed with aluminium hinges with suitable size nut bolts and shall have flexible fixing of each switchgear and controlgrae compartment with cable alley tray of size not less than 30 cm. duly painted with two coats of synthetic enamel paint powder coated, bus bar 1000 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland and LT panel shall be mounted on iron angle frame made out of 50 X 50X 6 mm frame with 4 no. legs size nit less than 45 cms fixed with nut bolts of suitable size (bottom portion of the panel) , grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I , suitable for and including taking down existing LT panel complete and including the following :-
(i) MCCB 4 pole 415 volts 200 amp rating thermal marnetic release with rupturing capacity 36 KA - 01 No. as incomer. Make-Legrand ,Siemens 3VL/Schneider NSX or equivalent make mentioned in Appendix 'B'
(ii) MCCB 4 pole 415 volts with thermal based release rupturing cap 25 KA, 100 amps - 1 Nos. for outgoing. Make-Legrand or equivalent make- Siemens 3VL/Schneider NSX or equivalent make mentioned in Appendix 'B'
(iii) MCCB 3 pole 415 volts with microprocesser release rupturing cap 18 KA, 63 amps - 02 No.s for outgoing. Make-Legrand or equivalent make- Siemens 3VL/Schneider NSX or equivalent make mentioned in Appendix 'B'
(iv) MCB SPN 'B' series 240 volts, 63 amps - 10 Nos.
(v) Indicator set RYB -01 Set of 3 pcs only Make- L & T or equivalent make mentioned in List of makes Appendix 'B'
(vi) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio. Make- Schneider Cat No. 30002567 or equilent/L&T/Legrand or equivalent make mentioned in List of makes Appendix 'B'
(vii) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
Supply, installation, commissioning and testing of totally enclosed outdoor type LT Panel in replacement weldless cubical Kiosk in modular bolted construction type dust and vermin proof floor mounted type (IP-65 degree of protection ) made out of 3 mm thick CRCA sheet of recommended size.All sheet metal parts separately chemically treated with 7 tank treatment process. The panel having both side opening door with locking arrangement.all doors fixed with aluminium hinges with suitable size nut bolts and shall have flexible fixing of each switchgear and controlgrae compartment with cable alley tray of size not less than 30 cm. duly painted with two coats of synthetic enamel paint powder coated, bus bar 1000 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland and LT panel shall be mounted on iron angle frame made out of 50 X 50X 6 mm frame with 4 no. legs size nit less than 45 cms fixed with nut bolts of suitable size (bottom portion of the panel) , grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I , suitable for and including taking down existing LT panel complete and including the following :-
(i) MCCB 4 pole 415 volts 200 amp rating thermal marnetic release with rupturing capacity 36 KA - 01 No. as incomer. Make-Legrand ,Siemens 3VL/Schneider NSX or equivalent make mentioned in Appendix 'B'
(ii) MCCB 4 pole 415 volts with thermal based release rupturing cap 25 KA, 100 amps - 1 Nos. for outgoing. Make-Legrand or equivalent make- Siemens 3VL/Schneider NSX or equivalent make mentioned in Appendix 'B'
(iii) MCCB 3 pole 415 volts with microprocesser release rupturing cap 18 KA, 63 amps - 01 No.s for outgoing. Make-Legrand or equivalent make- Siemens 3VL/Schneider NSX or equivalent make mentioned in Appendix 'B'
(iv) MCB SPN 'B' series 240 volts, 63 amps - 15 No.s
(v) Indicator set RYB -01 Set of 3 pcs only Make- L & T or equivalent make mentioned in Appendix 'B'
(vi) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio. Make- Schneider Cat No. 30002567 or equivalent make mentioned in Appendix 'B'
(vii) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
Supply and fixing bracket for street light fitting made out of 40mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by Engineer-in-Charge & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts & washer and painting of clamps and street light firtting bracket with one coat of red oxide primer, one under coat and one finishing coat with aluminium paint complete all as specified and directed.
Supply and fixing "as in repair" bracket for street light fitting made out of 40mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts &washer and painting of clamps and street light firtting bracket with one coat of red oxide primer, one under coat and one finishing coat with aluminium paint complete all as specified and directed.
Supplying, jointing and connecting cable straight through joint kit, out door, heat shrinkable type for XLPE/PVC cables including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 Sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including necessary excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting cable end termination joint kit, out door, heat shrinkable type for XLPE/PVC cables including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 50 sqmm to 70 Sqmm 3.5 core, 1100 volts grade cable including necessary excavation and earth work complete all as specified and directed.
Supply, installation, connecting electrically and testing of street light panel box complete with Astroonomical timer ,contactor rating 65 Amp, MCB 63 A TPN complete for mounted made out of CRCA sheet 1.6 mm thick, powder coated, having provision for Astronomical Timer, Contactor, Toggle switch, SP MCBs and MCCBs etc. having self closing door lock complete with fixing clamps or mounting arrangement all as required at site, specified or directed including taking out existing U/S street light switch any type and size. Make:- Havells cat part No. IHXTSO912A or equivalent make mentioned in Appendix 'B'
Supply, installation, testing commissioning of solar water (Evacuated Tube Collector) based on direct transfer of heat of capacity 250LPD with electric backup complete all as specified and directed.
Supply, installation, testing commissioning of solar water (Evacuated Tube Collector) based on direct transfer of heat of capacity 300LPD with electric backup complete all as specified and directed.
Supply, installation, testing commissioning of solar water (Evacuated Tube Collector) based on direct transfer of heat of capacity 500LPD with electric backup complete all as specified and directed.
Supplying and laying of 20mm dia CPVC pipes (Hot & Cold type) SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling/trenches or laying in floors complete all as specified and directed.
Supplying and laying of 25mm dia CPVC pipes (Hot & Cold type) SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling/trenches or laying in floors complete all as specified and directed.
S&F Ball valve (Brass inserted) of size for 20mm dia CPVC pipes complete all as specified and directed.
S&F Ball valve (Brass inserted) of size for 25mm dia CPVC pipes complete all as specified and directed.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks, three layers, (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms.) with and including inlet and outlet nipple complete.
S&F 750 litres capacity rotational moulded polyethylene water storage tanks, three layers, (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms.) with and including inlet and outlet nipple complete.
S&F 15 mm bore bib taps, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F and testing factory made sheet metal enclosure for MCB DB SPN 4 way 240 volt with single door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge.
S&F MCB single pole 230 volts any rating from 16 to 32 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables.
S&F MCB single pole and neutral 240 volts any rating from 40/50 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables.
S&F mild steel work of grade Fe-290 (Grade E-165) in stand for cooler from angle, flats etc. all as directed, framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete/sunken floors all as specified and directed.
M&L for lagging to pipes used in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 covered with chicken mesh wire netting 25 guage, with 0.01 aluminium foil complete all as specified and directed.
M&L for earthing in repairs complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 m below normal ground level with top edge of the earth plate at a depth not less than 1.5 m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply, installation and testing of centrifugal electric star delta motor 30 HP capacity, 2800 RPM, 415 volt complete all as directed and specified by Engineer-in-Charge.
Supply and testing for multistage Submersible pump set of minimum 7 stage having water discharge 11 LPS @ 116 Mtr head with suitable HP motor complete all as directed and specified by Engineer-in-Charge.
Supply, installation, Commissioning and testing LT panel board of suitable shape and size for 3 phase, 4 wire, 440 Volts AC supply, outdoor cubical type, dust and vermin proof, made out of 3.0 mm thick CRCA sheet with suitable size angle iron frame and legs duly finished with using powder coated paint of approved colour all over steel surfaces complete with including PCC work for fixing panel legs, front and back door locking arrangement and aluminium busbar of suitable shape and size for 3 phase and nuetral not less than 300 Amps rating with and including the following switchgear & controls :- (Make of panel: Power system & control/ DVEPL) (a) Incoming:- (i) MCCB 125 amps 4 pole having breaking capacity of Icu=25 KA with adjustable load setting (Make:- Schinder/ABB/L & T ) - 01 Nos (ii) Multifunction Meter 3 phase, 415 Volts, Accuracy Class 1.0, Flush mounting 96 x 96 mm complete including CTs- 02 Nos (Make:- Schinder/AE/L & T ) (iii) Indicating lamp (LED type) - 0 1 Set of three (Make:- Schinder /L & T / AE) (b) Outgoing:- (i) MCCB 3 pole, 415 Volts, 100 Amps- 02 Nos (Make L& T/Seimens/Schneider) (ii) Star delta (three Nos) contactors 50 Amps with relay - 02 Set (Make L& T/Seimens/ABB) (iii) Push button for ON/OFF - 2 set (v) Indication lamp ON/OFF/TRIP - 02 set (vi) capacitor MPP-Heavy duty Box type 10 kVAr with supervision relay and auto/Manual switch - 01 set
Supply and testing for multistage Submersible pump set of minimum 7 stage having water discharge 8.5 LPS @ 111 Mtr head with suitable HP motor complete all as directed.
S&F for star delta motor starter with Fully Automatic Star - Delta Starter in sheet metal enclosure type AC-3 phase, 415V, 50 Hz suitable for 30 HP electric motor. (Make of L&T model MU-G30 or equivalent of make ABB/Havells)
Note:- Cutting chases in walls/floors/ceilings wherever required for electric work shall be deemed to be included in respective item of Schedule ‘A’.
M/S INDIAN ELECTRICAL
Ashoka Engineers
KULBHUSHAN AGGARWAL
Vijay Kumar Contractor and Engineers
GOLDEN CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .