| 1 | 1₹8.1 CrAccepted-Finance AT LATHOR PS HARISHANKAR DIST BALANGIR | LATHOR | BALANGIR | ODISHA | ₹8.1 Cr | 1 | Accepted-Finance Qouted less bid amount |
| 2 | 2₹9.1 CrRejected-Finance | ₹9.1 Cr | 2 | Rejected-Finance Comparatively qouted highest amount |
| 3 | Not Admitted-Finance AT WORD NO 4 PO PS RAGHUNATHPALI DIST SUNDARGARH 769004 | SUNDARGARH | ODISHA | 769004 | - | - | Not Admitted-Finance Others-No consent for Bid validity extension |
| 4 | Not Admitted-Finance | - | - | Not Admitted-Finance Others-No consent for Bid validity extension |
| 5 | Not Admitted-Finance | - | - | Not Admitted-Finance Others-No consent for Bid validity extension |
Tender Value
₹8.1 Cr
EMD Value
₹8.2 L
Closing Date
19 Dec 2025, 5:00 pmClosed
CCE R and B CIRCLE BALANGIR
Office of the CCE R and B Circle Balangir
Building work
2025_EICCL_121707_7
CCE (R and B) BGR-13-2025-26
National Competitive Bid
Civil Works - Buildings
330 days
Kantabanji
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹8.2 L
Yes
13 Apr 2026
4 Dec 2025
20 Dec 2025
4 Dec 2025
19 Dec 2025
4 Dec 2025
4 Dec 2025 - 19 Dec 2025
CIVIL WORK Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.
Earth Work Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge. (a)Upto 1.5mtr Depth
(b) Beyond 1.5mtr to 3.00 mtr Depth
Filling the Foundation and Plinth, Sides of Foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. (a)Ground Floor
Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge. (a)Ground Floor
Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance,taxes, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. (a)Basement
(b)Ground Floor
(a)Ground Floor
(b)Beyond 1.5 M to 4.5M Depth
RCC WORK Providing, lifting, hoisting and laying in position Machine Batched , Machine Mixed and Machine Vibrated Design mix Cement Concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement. (A)R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc. (a)Basement
Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance,taxes, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. (a)Basement
(C)R.C.C. Beams, columns, grider and bressmer etc. (a)Basement
(c)First Floor
(d)Second Floor
Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance,taxes, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. (a)Basement
(C)R.C.C. Beams, columns, grider and bressmer etc. (a)Basement
(c)First Floor
(D)R.C.C. Floor and Roof slab, landing, balconies,Projecting sun shades and chajjas up to 4.3Mtr. Height. (a)Basement
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(b)First Floor
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
(c)Second Floor
(E)R.C.C. Grade Slab (a)Basement
(E)R.C.C. Wall (a)Basement
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
Providing & fixing TOR Fe-500 HYSD Reinforcement bars (SAIL /TATA /RINL) of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge. Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment). (a)Basement
BRICK WORK Providing and laying Brick Masonry work in Foundation & Plinth using Fly ash bricks of 23 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:4) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. (a)Ground Floor
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
Providing and laying Brick masonry work in Superstructure using Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:4) for Half Brick Masonry Wall with provisions for 2 nos 6mm dia MS bar at each 4th layer after immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. (a)Ground Floor
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
Providing and laying of Full Brick Masonry work in Superstructure using Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. (a)Basement
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
FINISHING WOR
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
K Providing 6 mm thick Cement Plaster in Cement Mortar of (1:4) to Ceilings of Roof Slabs, Stairs, Landings, Chajja, Shelves, Columns, Beams and Lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing , sundries, T&P etc. complete as per direction of the Engineer-in-charge (a)Basement
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
Providing 12mm thick cement plaster in cement mortar (1:4) to the surface of half brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. (a)Ground Floor
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
Providing 12mm thick cement plaster in cement mortar (1:6) to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading,royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. (a)Basement
Providing 18mm thick cement plaster on external surfaces of brick surfaces in two coats consisting of under layer 12mm thick in CM 1:6 (1 cement : 6 coarse sand) and top layer of 6mm thick cement plaster 1:4 ( 1 cement : 4 coarse sand) mixed with integral water proofing material of including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. (a)Ground Floor
Providing average 25mm thick grading Concrete in C.C ( 1:2:2 ) using 6mm size crusher broken black hard granite chips using 2% water proofing cement compound (Make: Sika / Fosroc / Equivalent) after scraping and cleaning the roof surface and finishing smooth to proper slope and gradient including cost of all materials, conveyance, sundries,T&P watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge. (a)First Floor
Providing 18mm thick cement plaster on external surfaces of brick surfaces in two coats consisting of under layer 12mm thick in CM 1:6 (1 cement : 6 coarse sand) and top layer of 6mm thick cement plaster 1:4 ( 1 cement : 4 coarse sand) mixed with integral water proofing material of including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. (a)Ground Floor
(b)Second Floor
Terrace Water Proofing Waterproofing application:- Providing and installing of two component acrylic modified flexible cementitious waterproofing coating with Masterseal 551/ equivalent over roof slab after carrying out pond test on roof slab filling all defects, saturating the surface mixing the products and then application in 2.0mm thickness (1.8 kg/ sqm coverage rate for 1.0mm thickness) in suitable layers complete in all respect, all material, tools, plants & labour complete in all respect.Density 1850kg/m3, Mix ratio (powder to liquid) 3:1 by weight. (Make:MYK / Fosroc /Tremco Pvt.Ltd./Asian Paint /Sika /Sunanda/ Mapei) (a)First Floor
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
Providing and applying waterproofing treatment to sound,moisture free concrete surface using Brushbond Ultraflex or equivalent- 2 component High Performance & Ultra flexible polymer modified elastomeric waterproofing membrane system capable of bridging substrate cracks up to 1 mm which supplied in 25 kg pack. System includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc., carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with Cebex 100-Plasticised expansive grout admixture supplied in 225 gm pouch, application of polymer modified coving at floor-wall junction, filling of annular space around rain water outlet using Conbextra GP2 - Non-shrink cementitious grout and application of two coats of Brushbond Ultraflex at a coverage @ 16m2 per 25kg pack to achieve 1 mm thickness in two coats followed by carry out protection screed / plaster etc. complete including all tools and tackles as per manufacturer’s specification.Brushbond Ultraflex cured material shall shall be having crack bridging of 1 mm, Elongation at Break (ASTMD 412) – >150 %, Tensile Strength (ASTM D412) – 1 N/mm2, Adhesion to substrate (ASTM D4541:2002): > 1.0 N/mm2, Water Permeability EN12390 (part8) 2008) Negative Pressure: Nil, Water vapour transmission (ISO 7783:2018): ˷20.81 g/m2.hr. Brushbond UltraFlex conforms to the requirements of DIN 1048, Part 5, 1991, ISO 7783:2018, ASTM D412 : 2013. Brushbond UltraFlex is deemed to be suitable for use with potable water sources as tested as per USFDA CFR 175-300. Item rate is inclusive of materials all labour, tools and tackles, scaffolding and transportation etc. but excluding protection screed concrete complete as per specification and as directed by EIC. (UGR Inner wall & base)
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
FINISHING WORK Supplying and finishing the Inside plastered surface of wall using cement based wall putty (Water based) of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge. (Make: Birla White/J K Wall Putty) (a)Basement
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
Supplying and finishing the Outside plastered surface of wall using cement based wall putty (Water based) of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge. (Make: Birla White/J K Wal
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
l Putty) (a)Ground Floor
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
Providing and applying Two Coats Plastic Emulsion Paint of approved make, quality and shade over a coat of wall primer of approved quality to the internal plastered surfaces including throughly brushing the surface to make free from foreign materials, sand papering, priming including cost of all materials, cost of all labour, conveyance, loading, unloading, scaffolding, staging, watering and curing, T&P etc. complete as per the direction of the Engineer-in-charge. (Note: Colour & shade to be approved before procurment & use).(Make:Dulux/Nerolac/Berger/Asian Paint) (a)Ground Floor
Providing and Painting with Two Coats Weather Coat Paint (exterior grade) of approved make & shade manufactured by reputed manufacturer to make an even finished surface over a coat of water bound cement primer and wall putty in all heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete.(Make:Dulux/Nerolac/Berger/Asian Paint) (a)Basement
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
Providing and painting Two Coats of Synthetic Enamel Paint of approved quality, brand and shade over a coat of red oxide primer to Iron Work including cost, conveyance, royalties, taxes, of all materials, cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. (Note: Colour & shade to be approved before procurment & use).(Make:Dulux/Nerolac/Berger/Asian Paint) (a)Ground Floor
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
Providing and Painting of Epoxy paint (Two or more coats) on steel work at all locations prepared and applied as per manufacturer's ecifications including appropriate priming coat(Red Oxide Zinc Chromate) , preparation of surface, etc. complete as per Direction of E.I.C. (Make:Dulux/Nerolac/Berger/Asian Paint) (a)Second Floor
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
FLOORING WORK Providing and laying of 600 mm x 600 mm Matt Finished Vitrified Floor Tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/RAK/Kajaria) (a)Ground Floor
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
Providing and laying of Matt Finished Vitrified Tiles in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 600mm x 600mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/RAK/Kajaria) (a)Ground Floor
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
Providing and laying of 600mm x 600mm Non-Skid Ceramic floor tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/RAK/Kajaria) (a)Ground Floor
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
Providing and laying of Glazed Ceramic Wall Tiles in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 600mm x 300mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/RAK/Kajaria) (a)Ground Floor
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
Providing & laying granite stone flooring using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge. (a)Basement
Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance,taxes, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. (a)Basement
Providing & laying granite stone flooring in Floors and landing using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (a)Basement
Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance,taxes, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. (a)Basement
Providing & laying granite stone tiles in dado/skirting using 10mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) (a)Basement
Providing & laying kota stone slabs in floors using 16 mm thick kota stone slab of approved quality, colour and size above 0.4 Sqm laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement : 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) (a) Basement Floor
Providing & laying kota stone slabs in dado/Skirting using 16 mm thick Kota stone of approved quality, colour and size above 0.4 Sqm laid over an under layer of 12mm thick cement mortar (1:3) (1 cement: 3 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cl
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
eaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) (a) Basement Floor
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
Providing 25 mm thick A.S. flooring with base C.C. (1:2:4) using 20 mm size hard granite crusher broken chips after roughening, scraping, cleaning the base, watering well and laying flooring to required level in panels 2m x 2m (Max.) by using dividing glass strips of 40 x 4 mm size, well compacted and top finishing smooth by trowel with a thick coat of neat cement punning, polished well including cost of all materials, labour, conveyance, sundries, T&P, curing etc. complete as per direction of Engineer-in-Charge. (a)Ground Floor
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(F)R.C.C. Lintel (a)Basement
Providing and laying 62 mm thick cement concrete flooring with Hardener topping comprising of an under layer of 50 mm thick cement concrete of mix 1:2:4 (1 cement : 2 coarse sand : 4 graded stone agrregate 20 mm nominal size) and 12 mm thick cement hardener topping layer of mix 1:2 ( 1 cement hardener mix : 2 parts of screened & washed stone agrregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litres per bag of cement and laying the concrete in alternate panels of 2m x 2m (max) including cleaning the surface to make free from foreign particles, cost of all materials, conveyance, taxes, loading, unloading, royalty, T&P, etc, all complete as per the direction of Engineer-in-Charge. (a) Basement Floor
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
BUILT IN JOINERIES Providing and fixing 65mm X 125mm factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (Make: WPC Door Frame: Century/Black Cobra/Rajshri Plastiwood,Colour:Coffee Brown) Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. (a)Basement
Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete. (Make: Flush Door: Greenply/Century/Merino, Laminate: Greenply/Century/Merino Hardware Fittings: Godrej/Dorset/Link/Dorma & Colour: Coffee Brown Mica) (a)Ground Floor
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
Providing and fixing of 30 mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with SS 304 Grade Matt Finished 3 Nos butt hinges of Size 100mm X 60mm X 2.5mm, 1 No 250mm X 16mm Aldrop,1 No 150mm x16mm tower bolt,2 No 150mm length Door handle with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Make: WPC: Century / Black Cobra / Rajshri Plastiwood, Hardware Fittings: Godrej / Dorset / Link / Dorma, Colour:Coffee Brown) (a)Basement
Providing and Fixing of Single Leaf Pressed Glavanised Steel Door: DOOR FRAMES Produced from 1.2 MM thick galvanized steel sheet formed to double rebate profile of size 125 x 60mm (+/- 0.3mm) with a maximum bending radius of 1.4mm. The door frames may be built into the brick or block walls using corrugated “ T ” Anchors not welded to the frame (first fix). Framesmay also be fixed on plastered openings with the help of Metallic Expansion Shield with counter sunk screw (second fix). Door Frames are supplied to knock-down form with butt joints for bolted assembly at site. SINGLE DOOR LEAVES Constructed from 0.8mm thick galvanized steel sheet formed to provide a 46mm thick fully flush, single leaf door with lock seam joints at stile edges. Internal Reinforcements are provided at top, Bottom and Stile Edges. The internal construction of the door is a specially designed Honey Comb structure with reinforcements at top, bottom and stile surrounds, The Gap between the sheets shall be filled with Honeycomb paper of minimum 150 gsm including the cost of all materials, cost of all labour, conveyance, loading, unloading, sundries, T&P, etc. complete as per the direction of the Engineer-in-Charge.( MAKE - STEELTECH ,JSW STEEL DOOR /TATA PRAVESH) (a)Basement
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
Providing & Fixing of ARAI certification Acousticaly treated auditorium door with heat activated intumescent fire seal strip mounted on the door frames on all three sides and one coat of anti-termite fire retardant primer. Door shutter consisting of 77mm thick door shutter having minimum 32 dB acoustic cum 120 min. fire rating having infill of 10x50 Anutone Synth Polyfibre density with FR Acrylic Sealant sandwiched between two 9mm thick (Starpan Make or Approved equivalent)Anutone Magnesium Oxside boards a 100% without asbestos, Brucite and Meerschaum having a density not less than 1150kg/M3 and thermal conductivity 0.14 W/m* K faced with 3.4mm thick commercial ply 1mm laminated on both sides with heat activated intumescent fire seal strip of size 10mm x 4mm mounted in the grooves having hardwood lipping including door closer, CE & EN 1154 certified 2 hrs fire rated with 10 years warranty tested to BS 476 Part 22 and as per approved make & single/double leaf panic exit devices, CE & EN 1125 certified 2 hrs fire rated tested in accordance with BS 476 Part 22. complete in all respect as per the direction of the Engineer-in-Charge. ( Make - Navair / Tufwud / Sinhop or Eqv) (a)Ground Floor
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
(E)R.C.C. stairs excluding landing but including railing. (a)Basement
Providing and fixing of 12mm thick Clear Toughened Glass Frameless Door With Dorma
Premium Fittings.Dorma Premium (9111198) Unilite Package BTS 75,UL PT 10 with Cover,UL PT 20 with Cover,UL US 10 Luck with Cover and PT 24,Dorma Premium (9137121) H Type Handle 450mm,12mm Clear Toughened Glass with Cutout and Hole, including the cost of all materials, hardware fittings, cost of all labour, conveyance, loading, unloading, T&P, etc, complete as per the direction of Engineer-in-Charge. (Make: Dorma/Godrej) (a)Ground Floor
Providing and fixing 12 mm thick frame less toughened glass partition Dorma Premium (911298) PT 90 Side Connector and PT 80 Glass to glass Connector with Silicone,12mm Clear Toughened Glass with Cutout and Hole,including perimeter sealing of glass to glass joints with silicon sealant ,etc.as per drawing and specification including the cost of all materials ,T&P,etc all complete as per the direction of Engineer-in-Charge. (Make: Dorma/Godrej) (a)First Floor
Supplying and installing Aluminium System - Fixed windows made out of ALUPURE/Equivalent make frame dimension of 39mm x 42mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3).Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of MCCOY /Dowcorning or equivalent. or Supplying and installing Aluminium System - Sliding windows made out of ALUPURE/Equivalent make frame dimension of 88mm x 40 & Sash dimension of 31mm x 61.5mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. (a)Ground Floor
S.S Railing Supplying, fabricating & fixing of polished stainless steel (304 grade) items made out of pipes, angles, flats, plates, hollow tube, square pipe bracing as per approved design and specification, buffing, polishing etc. with cost, conveyance, labour in railing, parapet, staircase, space frame etc required for the work complete in all respect as per direction of Engineer-in-charge. (a)Basement
Prefab Structure,Cladding and Structural Glazing Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing Glass Reinforced Concrete (G.R.C) Screens in approved size, pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘N.E.G JAPAN’ or equivalent, Super Plasticizers manufactured by ‘BASF’ or equivalent, Polymers manufactured by ‘BASF’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be ‘Dry fixing’ i.e. to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti / Fischer.
Providing and fixing Glass Reinforced Concrete (Cornice /Column) in approved size, pattern, design, shade and thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 - 4 Kg per Sq. Ft. the cornice should be made from 53 grade white Portland cement, quartz ,fine silica sand alkali resistant glass fibre ,super plastisizer ,polymers and uv resistant synthetic inorganic pigments should be used for pigmentation. The material casting should take place in FRP Molds. The fixing of Screen should be 'Dry fixing' i.e to be done with M S Galvanized Clamps and MS Frame with fixtures and fastehers etc. including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing sundries and T&P etc all complete as per direction of the Engineer-in-charge (a)All Floor
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorpora
ting principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board forTesting and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/ IEC 17025.
Providing openable side / top hung vision glass panels (IGUs) in structural glazing including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick hard coated low emmissivity glass, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and Terraceary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Earth filling Construction of embankment with earth approved material obtained localy with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2.
Pathway (Paver Block) Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.
Construction of granular sub-base by providing Grading IV Material, spreading in uniform layers with motor grader on prepared surface, mixing by place in method rotavator at OMC, and compacting with vibratory power roller to achieve the desired density, complete as per clause 401
Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018.
Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984.
Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces as per section 800 of MoRTH specifications for Road & Bridge works (5th revision) and instruction of Engineer in charge
Supplying and Filling clean course sand in foundation and plinth, free from deliterious materials, earth, earthclods, roots and boulders etc watered and well compacted,including cost of all materials, labour , and T&P etc complete below leveling course of open foundations/approach slab etc complete as per technical specification for Road & Bridge works (MO
RTH 5th revision) & as directed by Engineer in charge.
Grass Providing and fixing Neelgiri/Mexican grass turf with earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenance for 30 days or more till the grass establish properly as per direction of officer incharge.
SITE PREPARATION Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) . Screened through sieve of I.S. designation 20 mm
Screened through sieve of I.S. designation 16 mm
Screened through sieve of I.S. designation 4.75 mm
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.
SHURBS Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen pots of size 20 cm as per direction of the officer-in-charge. s per direction of the officer-in-charge.
Providing and stacking of Gardenia jasminoides of height 45-60 cm. with 3- 4 branches in earthen pots of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Murraya exotica of height 45-60 cm. in poly bags of size 15 cm as per direction of the officer-in-charge.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 45 cm dia, and 45 cm deep.
Disposal of surplus earth/debris staked at work site by mechanical means including loading and unloading and disposing the same within a lead of 5 km with hire running charges of all machineries, cost of all labour, labour cess, T&P required for the work etc. complete as directed by Engineer-In-Charge.
Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement. (A)R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc. Ground Floor
(B)R.C.C. Plinth Beam Ground Floor
Providing and Painting with Two Coats Weather Coat Paint (exterior grade) of approved make & shade manufactured by reputed manufacturer like NEROLAC / ASIAN / BERGER / DULUX or equivalent to make an even finished surface over a coat of water bound cement primer and wall putty in all heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete. Ground Floor
Supplying, fitting & fixing of M.S. grill made out of M.S. flats/square bars including wheel track, gear, bearing etc. as per drawing and design fixed in position to proper plumb, including a coat of priming with approved quality metallic primer, materials including cost, conveyance, taxes, transportation of all materials, cost of all labour, sundries, T&P etc. complete as per direction of Engineer in charge. Ground Floor
Providing and Painting two coats with synthetic enamel paint of approved make, quality and shade on new Steel work to give an even shade over an under coat of primer of approved brand and manufacturer including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, staging, T&P, etc, all complete as per the direction of Engineer-in-charge. (Note- colour and shade shall be approved before procurement and use.) Ground Floor
INTERNAL (P.H) Providing all materials, labour, T&P for laying/fixing of following dia CPVC pipes S.D.R-11 as per IS-15778 with ISI mark including fixing of required size CPVC fittings like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floor or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes,duties,transportation scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHIRVAD 50mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Providing all materials, labour, T&P for laying/ fixing of following dia uPVC pipes Sch-80 as per ASTM-D-1785/2004 including fixing of required size PVC fittings like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes, duties, transportation, scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHIRVAD 50mm dia from source to GL
50mm dia
Providing all materials, labour, T&P for laying/fixing of following dia uPVC pipes as per IS-4985 with ISI mark of 6 kgf/cm2 including fixing of required size uPVC fittings like,bend,Tee,elbow,offsets,etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes, duties, transportation, scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHIRVAD 50mm dia
Providing all materials labour, T&P for making grooves in bricks/stone masonary walls vertically or horizontally up to required depth and width in all floor for laying of pipes and fittings up to 50mm dia, testing the joints with required water pressure and making good the damages with cement concrete 1:2:4 with 12mm size h.g.c.b.chips and finished smooth with cement morter (1:4) to original shape including cost of materials, curing, conveyance, taxes of all materials etc. all complete as per specification & direction of EIC.
Supply , Installation, Testing & commissioning of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 14.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 (Make:OBO/ABB/ DHEN).
Providing all labour,T&P for cutting holes in bricks or stone masonry wall for taking pipes in all floors and making good the damages with cement concrete 1:2:4 finished smooth with CP 1:4 to original shape including cost of all materials, curing, conveyance, taxes, duties etc. all complete as per specification & direction of Engineer-in-charge. For 250mm thick wall
Providing all labour,T&P and cutting holes i
n RCC chajja/roof/floor for taking pipes through and making good the damages with supply of all required materials etc. complete as per the direction of the Engineer-in-charge.
Supply , Installation, Testing & commissioning of universal clamp made of SS to connect rod with flat conductor (Make:OBO/ABB/ DHEN).
Providing all materials, labour, T&P for fitting & fixing of following Brass Ball Valves with ISI mark in all floor & fixing with the pipes after cutting the pipes to required shape & size including wastage etc. of following nominal diameter, all complete including testing the joints with required water pressure.The cost inclusive of all duties,transportation scaffolding etc. all complete as per specification and direction of Engineer-in-charge. Make:ZOLOTO/LEADER 50mm dia ball valve
40mm dia ball valve
32mm dia ball valve
20mm dia ball valve
50mm dia brontz horizontal check valve
Supply all materials and labour for fitting and fixing of following size white glazed vitreous china integrated Half Padestal wash hand basin of size 565 x 460 x 395 mm of approved quality including cutting the walls & floor and making good the damages with cement concrete (1:2:4) etc. including all duties, transportation etc. all complete as per direction of EIC. Make : JAQUAR/HINDWARE/CERA. Rate as per CERA S2010103 with Fixing Accessories
Supply all materials and labour for fitting and fixing of following size white glazed vitreous china under counter wash hand basin of size 550 x 405 x 205 mm of approved quality including cutting the walls & floor and making good the damages with cement concrete (1:2:4) etc. including all duties, transportation etc. all complete as per direction of EIC. Make : JAQUAR/HINDWARE/CERA. Rate as per CERA S2030105 with Fixing Accessories
Supplying all materials, labour & T&P for fitting and fixing of following sizes of white glazed vitreous china back inlet urinal basin of size 310 x 300 x 555 mm confirming to specification of approved make as per IS-2556 with ISI mark in all floor along with supply & fixing of necessary component parts like pair of C.I./M.S. bracket including connection from supply pipe with all taxes, duties, transportation etc. all complete as per specification & direction of the Engineer-in-charge. Make : JAQUAR/HINDWARE/CERA .Rate as per CERA S4020114 or equivalent
Supplying, fitting and fixing of following types CP fittings of approved make and quality confirming to relevant IS specifications with leak proof threaded joints including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. Make : JAQUAR/HINDWARE/CERA Hand Shower (Health Faucet) Health Faucet ABS body with 1 meter SS braided connection pipe & Wall Hook (As per Cat. No F8030109AB of CERA)
15mm dia Angular Stop Cock with wall flange (As per CERA F1015201)
Two way Bib cock with Wall Flange (As per Cat. No.F1015163 of CERA)
CP soap dish holder (AS PER F5013116CH OF CERA)
C.P. Toilet Roll holder with stainless steel flap (As per Cat no.F5013110CH of CERA)
Towel Ring Round (As Per F5013115CH OF CERA)
150mmX150mm square anti cockroach trap
32mm Half Thread Waste Coupling (As per F8050102 OF CERA)
32mm Full Thread Waste Coupling (F8050101 OF CERA)
15mmx450 mm Braided Hose Connection Pipe with both side Nuts & Rubber Washers . (As per F8070402 OF CERA)
Extension Piece (15 x 25 mm) (As per CERA, Cat. No.: F8070301)
32mm dia C.P. Coat Hook (Double) (As per Cat. No. F5003108 OF CERA)
32mm dia CP on Brass Bottle Trap (As per Cat. No. F8060101 OF CERA)
Providing all materials, labour, T&P for fixing of following sizes of mirror 700 x 500 mm 5 mm thick glass mirror with doublecoat for protection and longevitygrounded edges for safety and silverplating on the back for better reflection in all floor including cost, conveyance, taxes of all materials complete as per specification and direction of E.I.C. Mirror (700x500mm) (Cat. No: B3510114 of CERA)
Pressmatic Pillar Cock (Cat. No: F9020101 of CERA)
Urinal Valve Auto Closing System with Built-in Control Cock & Wall Flange (F8010109 OF CERA)
Providing & fixing Toilet Cubicle (of following standard dimension which includes 600mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial, anti virus, anti fungal resistant 12mm thick solid compact laminate panels. Finish of the compact laminate should be Suede / *Raw Silk, which includs doors, pilasters & intermediate panels finished with approved texture/shade as per the detail drawings & as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard. The product should have Green Guard Certificate. Reduction of virus in 2 hours and 24 hours when tested by ISO 21702: 2019 standard. This also includes providing and fixing in position necessary hardware made out of Stainless steel (Grade 316) & Aluminium powder coated top rail as per manufacturer’s specifications & Architects instructions like (1) SS Door Knob, (2) SS Gravity hinges, (3) SS Thumb turn lockset indicators, (4) Aluminum Powder Coated Top Rail, (5) SS Coat Hooks, (6) SS U-Channels, (7) SS Adjustable Foot, (8) Noise Deafening Tape etc. (9) Screws & wall Plugs. The top fitting should consist of Aluminium Powder Coated top rail which will get fixed with Mid & End pilasters. All other hardware & screws will of stainless steel in 304 Grade with satin finish. Top rail is extruded Aluminium will be powder coated or anodized (Grade 6063 Micron Aluminium). All pilasters are supported by stainless steel adjustable footing with non corrosive steel inserts. Toilet Cubicle with standard dimension of 2100mm Height x 1000 mm Width x 1550mm Depth, which includes 600mm door size width). (Make: Merino)
Providing all materials, labour, T&P for fitting and fixing HPL Urinal partition Made of 12 mm thick compact laminate total height 1195 mm , Depth 450 with duties, transportation etc. all complete as per specification & direction of Engineer-in-charge. (Make: Merino)
Providing all labour, T&P and machinaries for installation,commissioning of Three phase sensor with level indicator (Domestic OHT & UGR) and cables etc as per direction of EIC.
Supply, installation,testing & commisioning of water cooler cum purifier with chiller in floor of following capacity including fixing the same on the floor with necessary water connection & waste waste arrengments with all labour, T&P etc.all complete as per the specification & direction of EIC. SS 304 Storage Cooler cum UV Water Purifier 80 lit Capacity 60 ltr per hr cooling capacity
, 80 ltr storage Model-AG Green Pure Chill 80SS UV (Eureka Forbes/Kent)
Supplying all materials, labour, T&P, fitting and fixing uPVC SWR pipes (Type-B) of approved make confirming to IS-13592/1992, both below & above ground level or fixing on wall surface in all floors including all taxes, duties, transportation & scaffolding etc. all complete as per specification & direction of the Engineer-in-charge. Make:ASTRAL/ASHIRVAD/FINOLEX 110mm dia soil & Waste pipe
Supplying all materials, labour, T&P, fitting and fixing of following dia uPVC SWR (Ringfit) fittings of approved make confirming to IS-14735 in all floor with all taxes, duties, transportation & requisite testing as per specification & direction of EIC.Make:ASTRAL/ASHIRVAD/FINOLEX 110mm Pushfit Coupler
110mmx87.5º bend
110mmx87.5º door bend
110mmx45º bend
110mm dia Single Tee
110mm dia Single Tee with Door
110mm dia Single 'Y'
110mm dia Single 'Y' with Door
110mm dia Double 'Y'
PVC Clamp Suitable for 110mm dia pipe
110mm dia Vent cowl
110mm Socket plug
Multi floor trap
Supplying all materials, labour, T&P, fitting and fixing uPVC SWR pipes (Type-A) For rain water Stacking pipe in the Duct(Co-moulded Ring type) of approved make confirming to IS-13592/1992with ISI marked, both below & above ground level or fixing on wall surface in all floors including all taxes, duties, transportation & scaffolding etc. all complete as per specification & direction of the Engineer-in-charge. Make:ASTRAL/ASHIRVAD/FINOLEX 110mm dia Bend (87.5 degree)
110mm dia pushfit coupler
110mm dia pipe
110mm dia Bend (87.5 degree) Door bend
Vertical Grating 150x150mm for Rain water gutter on terrace, opening to 110mm dia Rain water pipes
Supplying,of all materials,labour and T&P for Fixing Anchor Bolt and Anchor Rod and Ring over ceiling of each roof for hanging suitable dia uPVC swr type -B pipes and its fittings for soil & waste water pipe etc. All complete as per gradation of EIC. (Make-Hilti,Huliot,hira diamond walraven) Flush Ancho, Anchor Rod, Anchor Clamp/Ring -1No along with fitting & fixing charges for 110mm dia pipe
Supplying all materials,labour,T&P and fixing three layer Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto required height above ground level and placing the tank to the required position and providing flyash brickwork in cement mortar (1:4) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:4) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge.(Make -Sintex/Supreme) 5000 Litres Capacity Triple Layer Tank white for Domestic (1no)
Sinking of 200mmx150 mm dia Tube Well up to 100mtr. Depth. 1.Nos. of Borewell Labour for drilling a perfectly vertical bore hole for a specified dia for a specified depth below G.L through consolidated and un-consolidated rocks with down the hole hammer drilling rig or combination drilling rig (1200 cfm/ 300 psi) as required to suit the site condition as per the direction of EIC including use of own rigs with its accessories, T&P & consumables etc. for lowering of 200mm dia PVC/GI pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (GI/ PVC casing pipes, if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the Tube Well). Labour for drilling of 200mm dia & 150mm dia bore from '0' mtr. to '100' mtr.
Providing & lowering the following size PVC pipes (ASTM) with or without slotted pipes as per the necessity from 1.00m above ground level up to required depth and fitting and fixing up in perfectly vertical position, including cutting, threading pipe and slotted pipe and supplying and fixing all jointing materials, T&P etc. complete and keeping the top of the casing pipe threaded including plugging the tube well to prevent entry of foreign materials from above. The cost inclusive of pipes, fittings, labour, consumables, POL, consumables with hire & running charges of machinaries etc. as per specification & direction of EIC. Lowering of 200mm (8'') dia PVC plastic pipes Sch-80 as per ASTM-D-1785/2004 upto required depth.
Cleaning and developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment , labour, all consumables, running & hire charges of machinaries etc. all complete as per the direction of the EIC.
Supplying all materials, labour & tools and plant and grouting with cement slurry for sanitary sealing around the GI/PVC casing pipe up to 3mtrs below ground level to plug the bore hole including cost of cement all complete as per specification & direction of the Engineer-in-Charge.
Vertical Grating 150x150mm for Rain water gutter on terrace, opening to 110mm dia Rain water pipes
Supplying all materials, labours, T&P and providing fitting & fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase /1 phase line voltage ranging from 320 volt to 450 volt conforming to Si 8034/89 with following specifications with suitable control panel ,jointing with GI/PVC/HDPE pipes,electrification,testing, commissioning ,trial running, conveyance of all materials to worksite , payment of taxex etc all complete as per specification & direction of the Engineer in charge. Make- KIRLOSKAR/XYLEM Submerssible Pump Set 1.00 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 6110 L.M.P with outlet dia of 32 mm.
DOL control panel
2.50 sqmm cable
Vertical Grating 150x150mm for Rain water gutter on terrace, opening to 110mm dia Rain water pipes
Supplying all materials, labours, T&P and providing fitting & fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase /1 phase line voltage ranging from 320 volt to 450 volt conforming to Si 8034/89 with following specifications with suitable control panel ,jointing with GI/PVC/HDPE pipes,electrification,testing, commissioning ,trial running, conveyance of all materials to worksite , payment of taxex etc all complete as per specification & direction of the Engineer in charge. Make- KIRLOSKAR/XYLEM Submerssible Pump Set 1.00 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 6110 L.M.P with outlet dia of 32 mm.
DOL control panel
32mm dia steel short piece
32 mm dia HDPE Pipe
Bore Cap
C.I.Bracket
Rope Wire
Installation of Submerssible Pump set. (From UGR to OHT) Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge.. Make-XYLEM or equivalent 5 HP three phase 5 stage head range 38 to 59 metres, discharge 250 to 300 L.P.M with outlet dia of 50mm (1W+1S)
4 sqmm cable
Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing an
d commissioning at site.
Installation of Submersible Pump set (Basement Dewatering Pump, Fire Pumproom) Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge.. Make-KIRLOSKAR/XYLEM 2 HP three phase 5 stage head range 15 to 20 metres, discharge 250 to 300 L.P.M with outlet dia of 50mm (1W+1S)
Providing all materials, labour, T&P required for construction of RCC M-25 man hole chamber of following sizes having cube strength 200 Kg/cm2 at 28 days confirming to IS-456/2000 & IS-3370 at all locations & height using h.g. stone aggregate (Crusher broken) of 20mm & down size including machine mixing, lifting, hoisting, conveying, placing in position, mechanical consolidation, curing, de-watering (if required). The minimum thickness of RCC base slab, all side walls & roof slab shall be not less than 150mm, 150mm & 125mm (avg.) respectively. The cost shall be inclusive of rigid, levelled & plumbed centering & shuttering to required slope, allignment & size for all kinds of RCC work with steel/ ply centering materials with all bracing, ties, anchorage & supports and removing the same after required paid & placing M.S.Reinforcement HYSD bar of required dia including cutting, bending, straightening of approved quality as per approved design & drawing & tying the grills for RCC works & placing in position using binding wires (18 to 20 gauge soft drawn & cold annealed). PCC 1:3:6 with 40mm size h.g.c.b. metal of 100mm thick, moulding & shaping the channel & benching with C.C. 1:2:4 with 12mm size h.g.c.b. chips, 12mm thick cement plaster 1:3 with cement punning on inner wall surface, earth work excavation in all types of soil/rock including cement concrete cutting as per site condition, filling the foundation base with sand duly watered & rammed, providing, fitting & fixing of pre-cast factory made man hole cover with frame ( heavy duty) for clear opening 560mm dia, providing, fitting & fixing of poly propylene steel reinforced man hole steps of approved quality & size in two parallel line of 300mm spacing in vertical wall with centre to centre 375mm (staggered) etc.all complete as per specification & direction of EIC. Manhole chamber of Inner size 910mmx910mmx 910mm depth.
Extra for every additional depth of 0.10mtr. or part there of manhole size 910mmx910mmx 910mm upto 1500mm depth.
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. (Excluding cost for earth wok, back filling which will be paid separately). 160mm dia u-pvc pipe alround concrete
Construction of 1 nos of 150 users RCC Septic Tank of inner size 7.70x2.40x1.7m liquid depth of 2 year cleaning interval & Soak Pit of Inner Dia 1.50m & depth 3.00m Earth work in all kinds of soil within 50m initial lead & 1.5m initial lift including dressing, levelling & breaking clods to maximum 5cm to 7cm & laying in layers not exceeding 0.3m in depth & as per specification & direction of Department. Upto 1.5 m depth
1.5m to 3 m depth
Filling the pipe line trenches with sand including watering & ramming etc. complete including all labour, T&P, cost of sand, conveyance, taxes, royality, loading & unloading as per specification & direction of EIC.
Providing and laying plain cement concrete (1:3:6) in foundation and bottom layers using 40mm size hard black crusher broken granite metal of approved quality and size from approved quarry including cost, conveyance, royality, all taxes complete and providing all labour T&P for machine mixing, lowering, laying and compacting to proper thickness, watering and curing for the required period and including dewatering (if required) as per the specification & direction of Engineer-in-charge.
Providing all materials, labour, T&P for laying R.C.C. M-25 having minimum cube strength of 200 Kg/cm2 at 28 days confirming to IS 456/79 & IS 3370 for water tank at all location & height using graded H.G stone aggregate of 20mm & down size including machine mixing, lifting, conveying, placing in position mechanical consolidation curing, dewatering (if necessary) & testing the concrete for water tightness, rectification of defects if any etc., complete all as per specification & drawing including cost of
all material, labour, machinery hire charges, T&P and all testing charges (but excluding cost of reinforcement bars, binding wirings, centering & shuttering etc.) as per the specification & direction of Engineer-in-charge. & Providing & making strong, rigid, levelled & plumbed centering & shuttering to required shape, allignment & size for all kinds of RCC works with wooden or steel centering materials with all bracing, ties, anchorage & supports including provision for necessary holes for P.H. works including cost of nails etc. complete & dismantling & removing the same after required interval from the date of casting including cost of all materials with transportation, hire charges, taxes, loading, unloading all labour, T&P, sundries etc. complete as per the specification & direction of the Engineer-in-charge. (A)R.C.C. walls
(B)R.C.C. Floor and Roof slab
(C)R.C.C. Beams, columns, grider and bressmer etc.
(D)R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc.
Cutting, bending, binding, straightening HYSD bars of required diameter of approved quality as per approved design & drawing & tying the grill for RCC works & placing in position using binding wire (18 to 20 gauge, soft drawn & cold annealed) including cost of all labour, material, sundries, T&P, scaffolding etc. all complete as per the specification & the direction of Engineer-in-charge.
Providing, fitting & fixing of following sizes of precast factory made RCC man hole cover with frame including locking arrangement. The cost inclusive of all labour, T&P, taxes, transportation etc. all complete as per specification & direction of EIC. Man hole cover with frame 500mm frame with MHCover
Providing, fitting & fixing of Poly Propylene man hole steps of approved quality & size in two parallel line of 300mm spacing in vertical walls with centre to centre 375mm (staggered).The cost inclusive of all labour, T&P, taxes, transportation etc. all complete as per specification & direction of EIC.
Providing, fitting & fixing of 110 diax1.80m long UPVC SWR pipe (Type-B) of approved make confirming to IS-13592/1992 with Vent Cowl including construction of cement concrete pedestal (1:2:4) of size 0.30mx0.30mx0.45m ht. The cost inclusive of all labour, T&P, taxes, transportation etc. all complete as per specification & direction of EIC.
Providing, fitting & fixing of 110mm dia S.W.R Tee. The cost inclusive of all labour, T&P, taxes, transportation etc. all complete as per specification & direction of EIC.
Providing all labour, T&P for benching & making Channel for inlet & outlet chamber.
Providing all material, labour & T&P for filling the both inner & outer surface of soak pit with 40mm size hard granite hand broken metal etc. complete including lead & lift cost & conveyance, loading, unloading etc. complete as per specification & direction of EIC.
Providing all material, labour, T&P for Fly ash Brick masonry work using Fly ash of 23cm X 12 cm X 8 cm size having crushing strength not less than 75Kg/Sqcm. in cement mortar (1:4) including cost, conveyance, taxes, royalties, loading and unloading of all materials and labour and scaffolding, watering, curing T&P etc., complete as per the specification & direction of the Engineer-in-charge. Foundation & Plinth
Providing plaster with cement mortar including cement punning/ bitumen painting where required finished smooth over brick work with waterproofing cement based compound of approved quality including finishing smooth to proper slope and plane including cost of all materials with conveyance, royalty, taxes, watering, scaffolding and curing, all labour and T&P etc. complete as per specification & direction of EIC. 12mm thick C.P. 1:4 outer plaster
12mm thick C.P. 1:4 with punning innersurface
12mm thick C.P. 1:4with punning and bitumen painting over wall top.
Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/Finolex/RR Kable ) of ISI marked with 20 mm dia PVC heavy class FRLS non metallic conduit(Make-AKG/Polycab/precision/norpack/sudhakar) with 6A modular type switch(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) ) ISI marked , and ceiling rose ISI marked of modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection .Raw power supply switch board shall be separate from emergency power supply switchboard as per direction of Engineer -in -Charge.Each light point should have provision for ceiling rose & angle holder point. Group-A: L.P= F.P= C.B.P=
Group-B: L.P= F.P= C.B.P=
Group-C: L.P= F.P= C.B.P=
S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge.
Supplying and fixing including testing and commissioning of 6A modular socket outlet with 6 Amp switch including providing GI modular box with faceplate etc as required.Switch & socket: (modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) 1 nos 6 Amp 3-pin socket with 6 Amp switch.
2 nos 6 Amp 3-pin socket with 2 nos 6 Amp switch.
Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.
Wiring for circuit/ submain wiring along with earth wire of following size of FRLS heavy gauge PVC insulated copper conductor single core cable in heavy duty PVC conduit laid in surface/ recess as required.of make Wire-KEI/Havells/Finolex 2X2.5 + 1X2.5 sqmm FRLS Cu wire
2X4 + 1X4 sqmm FRLS Cu wire
2X6 + 1X6 sqmm FRLS Cu wire
4X10 + 2X10 sqmm FRLS Cu wire
Supply, delivery and fixing of Ceiling fan hook box made out of 18 swg GI sheet and containing 10 mm dia round ms bar projecting atleast 150mm on either side & duly bent to accommodate ceiling fan down rod bolt & having earthing arrangement as per direction of Engineer-in-charge.
SITC of recess/surface mounted 2'x2' 36 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Makepanasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro) . The luminaire must be Replacement Warranty will be 5years.
SITC of Energy efficient surface /recess mounted square /round shape 12 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
SITC of Energy efficient surface /recess mounted round shape 6 W LED spot luminaire of dimension of consists of white powde
r coated , die-cast Aluminium housing with high quality opal diffuser for glare-free uniform lighting distribution and lumen output of 660 lumens, CRI not less than 80,CCT of 6500 K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , The fixture design should be with flicker free operations ripple <5%, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.( TO BE USED FOR TOILET )(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
Single sided EXIT LED Light fitting signage with built in battery back-up for 2 hrs BAJAJ (CAT No : BESL O3 LED SSD WBB Green) / Equivalent of Crompton/ Wipro/ Schneider/ Philips as required.
SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
SITC of energy efficient LED tube light fittings with decorative alumunium LED batten along with LED tube light having power rating 40 watt and lumen output not less than 4400 lumen complete with electronic driver and all other accessories with diffuser i/c connection etc as required.The luminaire should be Replacement Warranty will be 2 years (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).
SITC of energy efficient LED tube light fittings with decorative alumunium LED batten along with LED tube light having power rating 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser i/c connection etc as required.The luminaire should be Replacement Warranty will be 2 years (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).
Supplying, installation, testing and commissioning of ceiling fan (5 star rating) including wiring the down rod, earthing etc as required (Make -Bajaj/Usha/ Crompton/ Orient/ Khaitan/ Havells). 1200 mm sweep
Supplying, installation, testing and commissioning of Exhaust fan with louvre (Make -Bajaj/Usha/ Crompton/ Orient/ Khaitan/ Havells) as required. 305mm sweep
20KVA UPS FOR ELV AND EMERGENCY LIGHTING Supply ,installation ,testing & commissioning of 20KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sicuency corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 32 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric / APC/ VERTIV) LOAD OF OT,ICU) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD.
BDBS,DB,AC DB,FLOOR PANELS,MCBS Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ ABB ITUS/LK -Exora-N as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 6 Way(8+12+18) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years .(LDB-03,PDB-02)
4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (ELDB-03,PDB-02)-Basement-02
Supplying and fixing following rating RCBOs/ MCBs in the existing DB complete with connections,testing and commissioning etc. as required. Supplying and fixing 63Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/LK in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years.
Supplying and fixing 40 Amps , 2P, 415 volts, RCCB breaking capacity 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/LK in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year
Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/LK in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 years..
Supplying and fixing of following sizes of heavy gauge PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supply and laying of 25/32mm U PVC trunking system and acessories.(Make:Legrand/MK(honeywell)
Providing and fixing extra down rod of 20 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored.
Data & Telephone SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9
.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit
SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length)
SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP
SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit
SITC of Pigtail, SM (OS2), SIMPLEX SC, PC TYPE, 1M, LSZH ,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db ,LSZH Jacket-Reduced Toxic Gasses Emitted During Combustion , 100% Factory Tested , Low Insertion Loss and Return Loss. Make: Legrand / Systimax / Panduit
SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 10 KM. Make: Cisco, Digisol, Netgear
SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
IP PBX Supply and installation of IP Based PoE Phone, 2 SIP accounts, 2 line keys, 3-way conferencing, 3 XML programmable context-sensitive soft keys, Dual-switched 10/100 mbps ports, integrated PoE, HD audio on speakerphone and handset. Make: Grandstream, NEC, Mitel
Manual Fire AlarmSystem-:Supply, installation, testing and commissioning of Conventional type Main Fire Alarm Control Panel (FACP), the panel shall be conventional type fire detection and alarm system with capacity of 2 zone complete with all accessories and battery back up for 48 hours in standby mode and 15 minutes in alarm condition. The panel shall have minimum of 80 character display complete accessories.Make- System sensor by Honeywell/Ravel/Bosch.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installing, testing and commissioning of conventional type Manual call point with all accessories complete. The device Make-System sensor by Honeywell/Ravel/Bosch.
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
Supplying, installing, testing and commissioning of conventional type Hooter at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. Make-System sensor by Honeywell/Ravel/Bosch..
Fire Extinguisher System Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex)
Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg wit
h all accessories (Ever safe/Fire shield/Ceasefire/Safex)
Supplying, installation, testing and commissioning of Mechanical Foam type 9 litre capacity Fire Extinguisher, ISI marked, IS: 10204, containing 540 ml AFFF liquid ISI marked, IS: 4989 Part II and a polyurethane coated CO2 Gas Cartridge, ISI marked, IS: 4947 complete with gunmetal union cap, nylon hose with plastic foam making branch and wall mounting bracket.(Make: superimax/Cese fire/Minimax)
First Aid Box.
Shock Treatment Chart (Odia / Hindi & English).
8 mm thick Rubber Mat.
Danger Board.
Air Terminal Supply , Installation, Testing & commissioning of 8 mm Aluminum Round Conductor. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts . Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. Tested for 100kA lightning current. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ). (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Stand for Fang Fix system 16 kg made up of frost resistant concrete. (Make:OBO/ABB/ DHEN).
Down conductor Supply , Installation, Testing & commissioning of 8 mm Aluminum Round Conductor. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. (Make:OBO/ABB/ DHEN).
Ring & vertical earthing system Supply , Installation, Testing & commissioning of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. (Make:OBO/ABB/ DHEN).
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.03 MB
DTCN8.pdf
Tender Documents • 1.18 MB
BOQ_569270.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid