Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹27.0 L+₹26,530 (0.99%)Rejected-Finance 309 VINAYAK TOWER CUTTACK PURI ROAD BHUBANESWAR 751 006 | KHORDHA | ODISHA | 751006 | L2 | Rejected-Finance Being L2 bidder | |
| 3 | L3₹27.4 L+₹66,450 (2.48%)Rejected-Finance PLOT NO 8 5179 SAILASHREE VIHAR CHANDRASEKHARPUR BHUBANESWAR DIST KHURDA ODISHA 751 021 | KHORDHA | ODISHA | 751021 | L3 | Rejected-Finance Being L3 bidder | |
| 4 | L4₹28.3 L+₹1.6 L (5.79%)Rejected-Finance CAMP OFFICE RANGE ROAD CHANDIPUR BALASORE ODISHA 756025 | BALASORE | BALASORE | ODISHA | 756025 | L4 | Rejected-Finance Being L4 bidder | |
| 5 | L5₹29.4 L+₹2.6 L (9.87%)Rejected-Finance 001 HPS MARKET KANPUR GANDHI CHAURAHA RAEBARELI UTTAR PRADESH 229206 | RAE BARELI | UTTAR PRADESH | 229206 | L5 | Rejected-Finance Being L5 bidder |
| Sl No | Description | Qty | Unit | Shree Mahavir Associates L2 | M/S RAJENDRA PRASAD L4 | SMART ENERGY SOLUTIONS L3 | Bob Enterprises L1 | SHREE ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, taking down/ laying of cables/ pipes or for shafts, wells, cesspits, manholes, pier holes, etc. and not exceeding 10 Sqm on plan and getting out in hard / dense soil complete all as specified and directed. | 461 | Cum | 188 ₹86,668 Lowest | 200 ₹92,200 | 240 ₹1,10,640 | 200 ₹92,200 | 365 ₹1,68,265 |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed. | 409 | Cum | 4 ₹1,636 Lowest | 100 ₹40,900 | 70 ₹28,630 | 140 ₹57,260 | 120 ₹49,080 |
| 3.00 | Removing excavated material (spoil) at a distance not exceeding 50m and depositing where directed at a level n. exc. 1.50 m above the starting point complete all as specified and directed. | 52 | Cum | 55 ₹2,860 Lowest | 250 ₹13,000 | 110 ₹5,720 | 85 ₹4,420 | 145 ₹7,540 |
| 4.00Supply and fixing GI tubing, medium grade pipe with all fitting, laid in trenches, or fixed to walls with clamps, floors, ceiling etc of the following bore complete all as specified and directed. | ||||||||
| 4.01 | 40 mm bore | 250 | RM | 399 ₹99,750 | 405 ₹1,01,250 | 550 ₹1,37,500 | 300 ₹75,000 Lowest | 410 ₹1,02,500 |
| 4.02 | 50 mm bore | 250 | RM | 433 ₹1,08,250 Lowest | 575 ₹1,43,750 | 740 ₹1,85,000 | 510 ₹1,27,500 | 485 ₹1,21,250 |
| 4.03 | 80 mm bore | 300 | RM | 755 ₹2,26,500 | 866 ₹2,59,800 | 1,120 ₹3,36,000 | 680 ₹2,04,000 Lowest | 750 ₹2,25,000 |
| 4.04 | 100 mm bore | 250 | RM | 1,233 ₹3,08,250 | 1,265 ₹3,16,250 | 1,520 ₹3,80,000 | 910 ₹2,27,500 Lowest | 1,150 ₹2,87,500 |
| 5.00 | Cleaning/slit removing with necessary high pressure water pump/cleaning agents/ Generator (as no electricity available at site)/ jointing pipe fittings and required at site complete all as specified and directed. | 800 | RM | 32 ₹25,600 | 10 ₹8,000 Lowest | 19 ₹15,200 | 15 ₹12,000 | 45 ₹36,000 |
| 6.00Labour only for attending break down of pipe line brusting /cracks and including cleaning /removal of broken pipe pieces of various lengths through cutting/welding etc as per site requirment and including by using sufficient dewatering pumps, JCB, Cranes as per site requirment complete all as specified and directed. | ||||||||
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 Dec 2025, 6:00 pmClosed
Shri Himanshu IDSE EE
GE (I)(CG) Bhubaneswar, Military Engineer Services, Near School Integral Education, Campus-2, Coast Guard Complex, Pallaspalli, Bhubaneswar-751 020 (Odisha)
REPAIR REPLACEMENT OF DISTRIBUTION PIPE LINE AND ALLIED WORKS INCLUDING PUMP MOTORS AT ARC CHARBATIA
2025_MES_742833_1
8628/BBSR/05/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
CHARBATIA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (I) (CG) Bhubaneswar
₹80,000
Yes
13 Feb 2026
4 Dec 2025
27 Dec 2025
4 Dec 2025
25 Dec 2025
18 Dec 2025
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, taking down/ laying of cables/ pipes or for shafts, wells, cesspits, manholes, pier holes, etc. and not exceeding 10 Sqm on plan and getting out in hard / dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material (spoil) at a distance not exceeding 50m and depositing where directed at a level n. exc. 1.50 m above the starting point complete all as specified and directed.
Supply and fixing GI tubing, medium grade pipe with all fitting, laid in trenches, or fixed to walls with clamps, floors, ceiling etc of the following bore complete all as specified and directed.
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Cleaning/slit removing with necessary high pressure water pump/cleaning agents/ Generator (as no electricity available at site)/ jointing pipe fittings and required at site complete all as specified and directed.
Labour only for attending break down of pipe line brusting /cracks and including cleaning /removal of broken pipe pieces of various lengths through cutting/welding etc as per site requirment and including by using sufficient dewatering pumps, JCB, Cranes as per site requirment complete all as specified and directed.
80 mm bore GI/CI/DI/MS Pipe
100 mm bore GI/CI/DI/MS Pipe
150 mm bore GI/CI/DI/MS Pipe
200 mm bore CI/DI/MS Pipe
250 mm bore CI/DI/MS Pipe
300 mm bore CI/DI/MS Pipe
450 mm bore CI/DI/MS Pipe
20 mm bore GI/CPVC/HDPE/UPVC Pipe
25 mm bore GI/CPVC/HDPE/UPVC Pipe
40 mm bore GI/CPVC/HDPE/UPVC Pipe
50 mm bore GI/CPVC/HDPE/UPVC Pipe
Excavation of existing pipe line upto 1.5 m depth and upto 3 mtr length at the points where water leakages detected during above operation for repairing of pipe line and filling up the excavated surfaces as per existing after repairing the pipe line complete all as specified and directed.
Labour only for site clearance/surface cleaning by removing of hurbs/shurbs/ wild vegetation/removing surpus soil to a distance n exc 50 mtr and making good surface of the E/M installations area & water supply network area with suitable T&P complete all as specified and directed. Note:- All T&P will be provided by the contractor without any extra cost and also not to cut any tree/plants during the execution of works.
S& F Compound girders and stanchions, and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, of size Fe 410-W(GdeE- 250) quality A or complete all as specified and directed.
M&L for removing of wild grass/vegetation/solid/earth particles/tree logs or other foreign particles which disturbed the suction of raw water from the of course of river (Mahanadi River) into the intake channel of the suction side of the raw water pumps installed at Chasapada Pump House so that the intake channel get sufficient raw water for pumping to the sedimentation bed by using sufficient & skilled labour from the suction pipe foot valve laying at the depth of about approx 10 feet under the water complete all as specified and directed. Note: (i) T&P required for removal/excavation/clearing shall be provided by the contractor and rate for the same be included in the quoted rates. (ii) Skilled Manpower required for making area at footvalve clear for intake shall be provided by the contractor and contractor shall provide all safety equipments for manpower for doing the necessary jobs in river/bank area and contractor will be responsible for the safe execution of the said job.
Servicing of sluice valves cast iron body by greasing/oiling using T&P as required as per manufacturer’s instructions & providing gland rope of superior quality to stop any leakage of sluice valves including replacement of defective check nuts complete all as specified and directed.
100-150mm dia
200-250mm dia
300- 450mm dia
M&L for repacking stuffing box of sluice valve spindle including taking apart and reassembling complete all as specified and directed.
Collecting water samples from deferent places like water pump for Testing of water at NABL approved laboratory for bacteriological test and chemical quality of water and test result submit to Engineer-in-Charge complete all as specified and directed.
Supply only grease suitable for water supply installation complete all as specified and directed.
Supply only cotton waste for water supply installation complete all as specified and directed.
Material & Labour for Shifting of existing serviceable Foot valve of 300mm/250mm/ 200mm bore from the pipeline & fixing the same in existing intake water line with necessary Gasket, Nuts & bolts as per site requirment from mahanadi river including necessary tools & plants complete all as specified and directed.
Supply and fixing CPVC end plug up to 50 mm bore for disconnecting of water supply line of vacant qtrs including necessary cutting / threading in old GI/CPVC pipe complete all as specified and directed.
M & L for mechanical clamp suitable for following dia of GI/CI/DI/MS pipe complete with long coller, two Nos circular rubber ring and casted ringh/ rubber gasket including 03/04 nos nuts, bolts and washers all as specified and directed. (Note: - all excavation and refillings are included in the item rate)
80 mm dia
100 mm dia
Supplying and laying in replacement CPVC pipes including all types of brass/plain fittings on wall complete all as specified and directed.
20 mm bore size
25 mm bore size
40 mm bore size
50 mm bore size
Supplying and laying in replacement UPVC pipes including all types of brass/plain fittings on wall complete all as specified and directed.
20 mm bore size
25 mm bore size
32 mm bore size
40 mm bore size
50 mm bore size
S & F in replacement of following sizes Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed,complete all as specified and directed .
20 mm bode size
25 mm bore size
40 mm bore size
50 mm bore size
Supply and fixing gland packing 12mm/14mm/16mm suitable for pumpset 30HP/60HP/80HP/100HP/ 125HP complete all as specified and directed.
M&L for repairing of hand pump complete with taking out all pipes, planger, cylinder etc cleaning all parts and cleaning of bore by air compressor till the clear water come out(not more than 10 hrs) and refixing to existing position complete all as specified and directed. (Note : Accessories will be paid separately as supply only)
Supply only double plunger with full brass body for hand pump for 40mm pipe complete all as specified and directed.
Supply only connecting steel rod for hand pump complete with sockets complete all as specified and directed.
Supplying and laying in replacement HDPE pipes with and including necessary fixing/joining arrangement complete all as specified and directed.
50 mm bore size
75 mm bore size
110 mm bore size
32 mm bore size
Shree Mahavir Associates (BID ID -3512188)
SMART ENERGY SOLUTIONS (BID ID -3505463)
M/S RAJENDRA PRASAD (BID ID -3507296)
SHREE ENTERPRISES (BID ID -3507830)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
TENDER.pdf
Tender Documents • 1.21 MB
BOQ_831812.xls
BOQ • 1.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .