Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹36.4 L+₹2.3 L (6.61%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹37.2 L+₹3.1 L (9.04%)Rejected-Finance 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹38.7 L+₹4.6 L (13.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹40.1 L+₹6.0 L (17.6%)Rejected-Finance CHHANI NANAK TEHSIL MANDAL PHALLAIN JAMMU J K 180003 | JAMMU | JAMMU | J K | 180003 | L5 | Rejected-Finance Other than lowest bid |
Tender Value
₹49.6 L
EMD Value
₹99,200
Closing Date
26 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (EAST) JALANDHAR CANTT
GE (EAST) JALANDHAR CANTT
PROVN OF SPL REPAIR TO BLDG NO T-77 OF CORPS PRO UNIT FOR ACCOMMODATION OF 14 WOMEN MILITARY POLICY AND CERTAIN OTHER SANCTIONED WORK UNDER GE (EAST) JALANDHAR CANTT
2022_MES_499682_1
GE/JULL/ET-67/2021-22
Open Tender
Civil Works
Item Rate
183 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹99,200
Yes
28 Mar 2022
7 Feb 2022
5 Mar 2022
7 Feb 2022
26 Feb 2022
21 Feb 2022
60 days
Amount
Surface dressing not exceeding 15cm deep in soft/ loose soil including removing bushes/ small trees etc complete all as specified and directed
Excavation in trenches in soft /loose soil, not exceeding 1.5 m wide and not exceeding 1.5m in depth for foundations etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 sqm on plan and getting out complete all as specified and directed.
Returning, filling in including leveling, watering and well ramming in layers n. exc. 25 cm thick each layer complete all as specified and directed.
Removing excavated material (soils) to a distance n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
Material and labour for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation filling, mass concrete etc complete all as specified and directed.
Material and labour brick work with old size sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius and built in cement mortar (1:4) complete all as specified and directed.
Material and labour brick work with old size sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius and built in cement mortar (1:6) complete all as specified and directed.
Material and labour for brick work with old size sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:6) complete all as specified and directed.
Material and labour 50mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection/ path including finishing the concrete surface even & smooth without using extra cement complete all as specified & directed.
Material and labour RCC M-25 (Design mix) using 20mm graded stone aggregate as in foundation, including rafts, footings, foundation beams, plinth beams, mass concrete and bases for columns etc complete all as specified and directed.
Material and labour RCC M-25 (Design mix) using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts etc complete all as specified and directed.
Material and labour RCC M-25 (Design mix) using 20mm graded stone aggregate as in slabs supported on wall, beams and column in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter, for rough finished concrete surfaces complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular in rough finished surfaces of concrete complete all as specified
Material and labour for MS TMT bars 10 mm and over dia and cut to length, bent to shape required including cranking bending spirally for hooping for clos hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed
Material and labour for mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
Material and labour for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands plinth courses, roof kerbs or mud stops, benching, coping, bed plates, parapets, water through and the like etc including weathering, slightly rounded or chamfered angles throating, edges of interlocking/ chequered tiles etc complete including necessary form work complete all as specified and directed
Material and labour preparation of new plastered surface of ceiling and applying three coats of white washing complete all as specified and directed.
Material and labour for approved earth filling including spread and levelled in layers not exc 25 mm thick watering and rammed to a true surface complete all as specified.
Material and labour hard core of broken stone or boulder of gauge n. exc. 63mm, deposited, spread and leveled in layers n.exc. 15cm thick, watered and well rammed to a true surface complete all as specified and directed.
Material and labour for 75mm thick PCC (1:2:4) type B-2 (using 40mm graded stone aggregate), as in sub floors, sub base, hard standing, concrete surfaces finished fair & even to receive topping floor finish/layer complete all as specified and directed.
Material and labour for 100mm thick PCC (1:3:6) type C-1 (using 20mm graded stone aggregate), as in sub floors, sub base, hard standing, concrete surfaces finished fair & even to receive topping floor finish/layer complete all as specified and directed & directed.
Material and labour for 25mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in sub floors, sub base; concrete surfaces finished fair & even to receive topping floor finish/ layer complete all as specified and directed.
Material and labour for non skid ceramic coloured tiles of size 300 x 300x 7 to 8mm thick in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
Material and labour glazed ceramic coloured tiles of size 450 x 300 x 6 to 7mm thick as in vertical surfaces i.e. skirting/ dado set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface with & including rendering 10mm thick in cement mortar (1:4) complete all as specified and directed.
Material and labour 15mm thick cement mortar (1:6) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Material and labour 15mm thick cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Material and labour rendering 15mm thick cement plaster on brick or concrete surfaces in cement mortar (1:4) mixed with integral water proofing compound in the proportion recommended by manufacturer, surfaces finished fair and even complete all as specified and directed. (WPC shall be measured and paid separately under appropriate item of this BOQ).
Material and labour 5mm thick cement plaster in cement mortar (1:3) as on ceiling, soffits of RCC shelves, surfaces finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer and one coat of birla white putty complete all as specified and directed.
Material and labour complete removal of existing treatment from wall surface and applying two coat of oil bound distemper over one coat of primer all as specified.
Material and labour for preparation of old decorated surfaces of walls, including washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of oil bound distemper complete all as specified and directed.
Material and labour preparation of newly plastered or un-plastered surface of walls including cornices, plasters etc. and applying two coats of cement base paint complete all as specified and directed.
Material and labour complete removal of existing treatment by washing, rubbing down and stopping etc on wall surfaces and applying two coats of cement base paint complete all as specified.
Supply and fixing factory made solid panel PVC door shutters 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site, complete all as specified and directed.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
Supply and fixing 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed.
Supply and fixing PVC (SWR) bends any radius 110mm bore complete all as specified and directed.
Supply and fixing PVC (SWR) vent cowl 110mm bore all as specified and directed.
Supply and fixing cast iron floor trap with grating including jointing to waste pipe in run lead joint fixed in cement concrete type (1:2:4) type B-1 diameter of outlet 75mm, fixed in repairs complete all as specified and directed.
Supply and fixing in repairs mild steel CP grating 125mm dia with centre hole all as specified and directed by the Engr-in-Charge.
Supply and fixing 150mm dia SGSW gully trap set and jointed in cement concrete as in repairs complete all as specified and directed.
Material and labour for galvanised steel tubes 15mm bore, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc. including taking up/ down existing tubing complete all as specified and directed.
Material and labour for galvanised steel tubes 20mm bore, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc. including taking up/ down existing tubing complete all as specified and directed.
Supply and fixing vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest including CI 'P' or 'S' trap with providing lime concrete bedding and connecting to flushing cistern complete including breaking up existing damaged WC seat and connecting flush pipe etc and make good to floor fixed in repairs complete all as specified.
Supply and fixing vitreous china wash hand basin, white, flat back size 550 x 400mm including one number brass CP waste coupling, 32mm dia, brackets 2 numbers including cutting for and pinning in ends of brackets complete all as specified and directed.
Supply and fixing pillar tap, cast copper alloy chromium plated, with capstan heads, 15mm bore dia of pipe screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe, fixed complete all as specified and directed.
Supply and fixing PVC connection fiber, reinforced 45cm long 15mm in size with brass check nut and PVC washers at both ends complete all as specified and directed.
Supply and fixing in repair 15mm angle/ stop valves, fancy type chromium plated, screwed down , high pressure with crutch or butterfly handle screwed at two right angles ends for both iron pipe complete all as specified and directed.
Supply and fixing in repairs bib taps, cast copper alloy, chromium plated, long body fancy type with capstan headed, screwed down, screwed for 15mm bore iron pipe complete all as specified and directed.
Supply and fixing in repair brass chromium plated shower rose of 125mm size with or without swivel joints including fixing to steel pipe or union complete all as specified.
Supply and fixing brass chromium plated tubular towel rail 20mm dia, ‘D’ type, 600mm long between flanges fixed complete all as specified and directed.
Supply and fixing brass chromium plated tower ring 15cm dia, fixed in repairs, complete all as specified and directed.
Supply and fixing Acrylic corner set of 3 pieces as per sample approved by Engineer-in-Charge all as specified and directed.
Supply and fixing rotational moulded polye-thylene water storage tanks, 1000 litres capacity (cylindrical vertical with closed top), ISI marked, hoisted and fixed in position all as specified in SSR Part I, complete all as specified & directed.
Supply and fixing rotational moulded polye-thylene water storage tanks, 500 litres capacity (cylindrical vertical with closed top), ISI marked, hoisted and fixed in position all as specified in SSR Part I, complete all as specified & directed.
Material and labour ball valve brass high pressure with polythene float and fly nut complete screwed for 20mm bore dia of iron pipe or brass ferrule and fixed complete all as specified
Supply and fixing 100mm size mild steel butt hinges, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
Supply and fixing MS 150mm size PTMT bow handle fixed with machine screws complete all as specified and directed.
Supply and fixing 200mm size PTMT tower bolt fixed with machine screws complete all as specified and directed.
Supply and fixing Steel ventilators, fixed type, with glazing bars complete all as specified and directed.
Supply and fixing extruded aluminium alloy handles, fabricated type, anodised, D-type, 150mm size, all as specified and directed.
Supply and fixing aluminium anodised, barrel tower bolts of extruded section and fixed, 250mm long all as specified and directed.
Supply and fixing 300mm long aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified and directed.
Material and labour for preparation of new wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
Excavating in post holes (or similar holes) each n.exc 0.5 cum in soft/ loose soil, getting out, returning, filling in, watering and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm and removing surplus soil to a distance n.exc 50m and making good surfaces complete all as specified and directed.
Material and labour PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation filling, post hole, mass concrete, surface channel and drains and other similar work etc complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc but excluding precast concrete articles complete all as specified and directed
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and removing surplus spoil out of defence land where directed complete all as specified.
Material and labour for 25mm dia powder coated mild steel curtain rod, fixed with & including MS powder coated hooks/ brackets and decorative finials (at both side), shade as approved by GE complete all as specified and directed including fixing of long size rawl plugs in wall for MS hook fixed in repairs complete all as specified and directed.
Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
Supply and fixing mild steel work as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates including distance pieces, cleats etc (Fe-410-W (Gde E-250) Quality-A complete all as specified and directed
Supply and fixing structural steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. using steel conforming to Fe-410 Gde-E-250 complete including drilled for fixing of steel sheeting or other covering; doors, door frame chowkhat etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing including necessary cutting drilling and welding etc complete all as specified and directed.
Material and labour for preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for powder coated aluminium anodised door shutter having 150mm x 44mm x 2.85mm thick bottom rail, 150mm x 44mm x 3mm thick middle rail 100mm x 44mm x 2.85mm thick stile and top rail including necessary fittings joinery cleat, glazing packing snap beading 10mm x 10mm, anodised aluminium handle 200mm long (02 No), 3 No 100mm size chromium plated butt hinges, 2 No 200mm size aluminium tower bolt and aluminium body hydraulically door closer, designation No-3, universal type, weight between 61 to 80 kg etc including frame of section 100mm x 44mm x 3mm and door shutter, bottom portion covered with 9 mm thick pre-laminated particle board, interior grade, pre-laminated on both sided with decorative choice lamination (colour/design approved by Engineer-in-charge) fixed to aluminium frame work and top portion covered with 5.50 mm thick float glass and pattern. One mortice lock (Make: Harrison) with shutter and fixing complete all as specified and directed.
Material and labour provn of powder coated anodised aluminium cabin having 150mm x 44mm x 2.85mm thick rail, 100mm x 44mm x 3mm thick stile and top rail including necessary fittings joinery cleat, glazing packing snap beading 10mm x 10mm, including frame of section 100mm x 44mm x 3mm and door shutter, bottom portion covered with 9 mm thick pre-laminated particle board, interior grade, pre-laminated on both sided with decorative choice lamination (colour/design approved by Engineer-in-charge) fixed to aluminium frame work and top portion covered with 5.50 mm thick float glass and pattern, with shutter and fixing complete all as specified and directed.
Supply and fixing Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws as specified and directed
Material and labour for Granite (of any type) work 20mm thick machine cut (table rubbed and polished) in steps jambs, pillars, window cills, cooking platforms, shelves in cupboard, hand wash places and like including necessary cutting and grooving to walls and making good including 15mm thick in cement mortar (1:6) screed bed or bedding layer and pointing with cement mortar (1:2) with admixture of pigment to match with shade of granite complete all as specified and directed.
Material and labour 60mm thick machine pressed precast concrete inter-locking paver blocks any shape and size conforming to IS 15658-2006, M-35 grade, with grey cement and pigment, laid in floor/ path/ hardstandings in any pattern as approved, laid over and including 30mm thick sand cushion and interstices filled with sand using plate vibrator complete all as specified and directed.
Material and labour PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in concrete bed to 150mm bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Material and labour for 150mm bore RCC pipe (ISI Marked), class NP3, laid and jointed in cement mortar with collars, laid in trenches at any depth and tested complete all as specified and directed.
Material and labour for precast RCC (1:2:4) type B-1 using 20mm graded stone aggregate and set in cement mortar (1:4) as in landing, manholes cover slabs, chajjas, shelves and similar articles with plain fair faces, including champers, weatherings, throating etc complete all as specified and directed.
Material and labour for cutting into existing manholes for connecting new drains by cutting out existing benching for forming branch, channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 and making good pipe and reforming benching as required finishing even and smooth for 150mm bore pipe complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any gauge, thickness, Nainital or similar pattern roof coverings complete all as specified and directed
Supply and fixing rolled mild steel work roof trussed (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, Tee, Angle, Channel or Flat Sections) including distance pieces, cleats etc, Fe-410-W (Gde E-250) complete all as specified and directed.
S&F compound girder complete all as specified and as and stanchions, lattice girder, aerial masts, staging of water tanks and the like including caps, bases splices etc built up from two or more beam or channel section for angle with plates including all lattice bar stiffeners, gussets plate etc Fe-410 (Gde E-250) Quality-A complete all as specified and directed
Dismantling of brick tiles single layer as in roof covering all as specified and directed.
Demolition of mud in roofs any thickness including plastering and leaping (whether full thickness removed or only a part thereof) complete all as specified and directed.
Material and labour for bitumen primer applied on plastered surface of roof at the rate of 0.40 kg/sqm of surface area of roof for water proofing and dump proofing treatment complete all as specified and directed.
Material and labour for applying a coat of hot blown paving industrial bitumen 85/25 at the rate of 1.20 kg/ sqm over a coat of primer @ 0.3 litre per sqm over the roof surface including cleaning surfaces complete all as specified and directed
Material and labour for APP based polymeric membrane minimum weighing 3kg/ sqm and minimum 3mm thick reinforced with polyester non wove fabric (wt. not less than 150 gms/ sqm) laid on primed surface by forced application complete all as specified and directed complete all as specified and directed. Make: Shalimar Tar Products/ IWL Ltd/ Torchar.
Material and labour for brick tile terracing with 40mm thick brick tiles laid over and including 15mm thick screed in cement mortar (1:6) and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed.
Material and labour for cutting out cracks to V-section in existing RCC roof slabs or terracing, cleaning out and filling with a hot mixture of bitumen VG-10 and clean dry sand 1:1 (by weight) complete all as specified and directed.
Material and labour flush pointing to brick terracing tiles in cement mortar (1:3) complete all as specified and directed.
Material and labour for preparation of old surfaces of ceiling including scraping down smoke soots, moulds, moss and trading oil and greasy spots etc including cornices, pilasters etc. on plastered or un-plastered surfaces and applying two coats of white wash complete all as specified.
Dismantling floor, hearth or wall tiling/ china mosaic including cement mortar bedding (but not backing), removing rubbish off outside MD land complete all as specified and directed.
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exc. 0.18 Sqm but not exceeding 0.38 Sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed.
All as per item No 99.00 but in skirting, dado & vertical surface over and including 10mm thick screed in cement mortar (1:4) on wall, finished even and rough to receive the top layer as specified.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
Supply and fixing mineral fibre acoustical suspended ceiling system with dune (Tegular) edge tiles with 24mm exposed grid. The tiles should have humidity resistance of 99%, NRC 0.5, light reflectance > 85%, thermal conductivity K=0.052-0.057 w/m K, colour white, fire performance UK class 0/ class I (BS 476 pt-6 & 7) in module size of 600x600x16mm, suitable for green building application with recycled content of 32%. The tile shall be laid on prelude 32 with 24mm wide T section flanges colour white rotary stitching on all T sections i.e. the main runner, 1200mm & 600mm cross Tees with a web height of 27mm and a load carrying of 7.1 Kgs/sqm and minimum pull strength of 100 Kgs. The T section have galvanising of 90 grams per Sqm and need to be installed with suspension system. All accessories manufactured and supplied by armstrong world industries
Taking down carefully existing point wiring of any type (ie on wooden batten, surface conduit, casing capping or concealed conduit) complete for light, fan socket or power point with fitting & fixture such as DB, ceiling rose, electric fittings, holders, switches, sockets, wooden batten, conduit etc including accessories such as wooden gutties/ rawl plug, screw etc including removing materials from site and making good disturbed surface of walls, floors etc. complete all as specified and directed
Material and labour for point wiring for one light point controlled by one switch with 1.5 Sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through in and include/ concealed conduit and accessories and terminated in and including new sunk type pressed steel terminal switch boxes 1.6mm thick with plastic laminated bakelite sheet 3mm thick fixed with nickel polished brass screws with cup washers and including 1.5 Sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed. Note-The quoted rate include the cost of cutting chases in wall/floor/roof for concealed wiring and make good the disturbed surface to match with existing.
All as per srl item No. 104.00 above but for one fan point controlled by one switch
All as per srl item No. 104.00 above but for one socket outlet 3 pin 5 Amps on independent board.
All as per srl item No. 104.00 above but for one socket outlet 3 pin 5 Amps on same board with other switches.
All as per srl item No. 104.00 above but with 2.5 Sqmm copper (nominal area) FRLS cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm with stranded copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed.
Supply and fixing switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified and directed.
Supply and fixing switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified and directed.
Supply and fixing switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal 230V AC complete all as specified and directed.
Supply and fixing socket out let 3 pin, 6 pin 15 Amp, flush type complete all as specified.
Supply and fixing socket out let 5 Amp, 5 pin flush type complete all as specified and directed.
Supply and fixing ceiling rose surface type bakelite 65 x 50mm three terminal complete all as specified and directed.
Material and labour for Sub main wiring with two run of PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through PVC rigid non metallic conduit including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation complete all as specified and directed. Note: Two run of 4 sqmm wire and one run of 4 sqmm wire as earth wire through rigid PVC conduit shall be measured as one RM.
Material and labour for sub main wiring with PVC insulated cable copper conductor FRLS two single core 6 Sqmm drawn through PVC rigid non metallic conduit including earth continuity FRLS copper conductor 6 sqmm PVC insulated with green insulation complete all as specified and directed. Note: Two run of 6 sqm wire and one run of 6 sqmm wire as earth wire through rigid PVC conduit shall be measured as one RM.
Material and labour for MCB SP 6 to 32 Amps, B-curve complete all as specified and directed.
Material and labour for MCB SPN 6 to 32 Amps, B-curve complete all as specified.
Supply and fixing in replacement Deco Ultra Slim linear LED lighting fixture with co-extruded polycarbonate body environmental friendly energy efficient ready to use pack 18/20 W LED 6000K with square decorative end caps complete all as specified and directed
Supply and fixing in repair energy saving bulk head light luminaire with opal diffuser LED 10 watt 6000 K, power factor more than 0.90, IP-65 class-I protection with high efficiency BIS marked LED electronic driver, surge protection 2 KV, operative on 140 volts to 270 volts AC supply complete prewired, connecting and testing complete all as specified and directed. Notes:- (i) Contractor shall provide 2 years written warranty for the LED fixture complete including driver from the certified date of completion from the local office bearer of manufacturers. (ii) Contractor shall produce LM-79 and LM-80 Report of NABL accredited Laboratory from manufacturer. (iii) Products must be made in India only.
Taking down and refixing ceiling fan of any sweep or make, filling cavities with filler one coat after cleaning, painting the complete fan (as per previous colour) using synthetic enamel paint by spraying including replacement of flexible wire, rubber reel, nut, bolts etc. and re-fixing in original position complete all as specified and directed.
Supply and fixing five step socket type fan regulator, electronic type, single phase, including connection complete after dismantling/ removing unserviceable regulator all as specified and directed.
Supply and fixing sheet metal enclosure for DBs when MCBs to be used, SPN 8 ways 240 V, IP 54, with 200 Amps rated bus bar, double door all as specified
Material and labour for energy saving & environmental friendly long life versatile pressure die-cast aluminium housing luminaire with heat resistant glass and suitable optics for uniform distribution of light 35 watt LED for bldg security lights with high efficiency electronic driver, having IP-66 protection, surge protection min 2 KV power factor more than 0.95 complete operative on AC supply 140 volts to 270 volts pre-wired and product should be made in India only including bracket made out of GI pipe 25mm dia 1.20m long bent to shape and clamp 40x6mm with nuts and bolts complete all as specified. Notes: (i) Contractor shall be provided 2 years written manufacturer's guarantee for the LED fixture complete including driver from the certified date of completion. (ii) Contractor shall be produce LM-79 & LM-80 report of NABL accredited Laboratory from manufacturer.
Material and labour for earthing complete with & including galvanized iron plate of size 600 x 600 x 6mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5 below ground level connected to galvanized earth wire soldered and riveted or connected to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part-I (2009) and connected to panel board, all as specified and testing on completion including provision of earth wire 4mm dia duly protected with and including 15mm dia bore light grade GI pipe upto 7.5m from electrode to earth point including provision of the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate and GI medium grade watering pipe of 20mm dia bore with funnel with wire mesh including all necessary excavation & earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC (1:3:6) type C-1 as in earth chamber, 50mm thick RCC cover using cement concrete (1:2:4) type B-1 reinforced with & including 8mm dia mild steel TMT bar @ 100mm c/c both ways with suitable handle for lifting & including form work and MS frame using MS angle of size 25mm x 25mm x 3mm complete all as specified & directed. Note: On testing, after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to the department.
Supply, laying, testing and commissioning of LT cable XLPE insulated PVC sheathed, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor size 16 Sqmm 2 Core all as specified and directed
All as per srl item No. 126.00 here-in-before but 16 Sqmm 4 Core
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/ abutting each other complete all as specified and directed.
Supply & spread unwashed dry river sand cushioning and covering the under ground cable in trenches complete all as specified and directed Note : Punning thickness of 18cm will be measured.
Supply, installation and testing of electric sanitary napkin incinerator, automatic operation, wall mounted/ floor mounted with stand made out of 1mm thick minimum powder coated sheet with suitable insulation, incinerator chamber, removable type ash tray, digital temp display, thermostat cutoff suitable flue pipe upto wall to emit exhaust outside with all necessary electric components etc of capacity 200 pad per day complete conforming to latest MSWM rules/CPCB/PPCB guidelines complete all as directed. Make: HLL life care/Faraday ozone/Bharti sales or equivalent as approved by GE.
Material and labour for DB's 4 way VTPN double door with bus bar of 200 Amps rated pre-fitted with MCCB as incomer, 63 Amps, four pole, 415 volts with capacity 16 KA, and MCBs SP 6-32 Amps 10 KA (as per site requirement) in outgoing circuits complete with PVC insulated FRLS copper conductor wire of suitable size, with neutral bar and earth bar complete all as specified and directed. Note:-Rate for MCCB and MCB are deemed to be included in quoted rates.
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .