| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | L1 | Accepted-AOC Being (L1) | |
| 2 | L2₹15.0 L+₹60,750 (4.23%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L2 | Rejected-Finance Other than (L1) | |
| 3 | L3₹16.1 L+₹1.8 L (12.2%)Rejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | L3 | Rejected-Finance Other than (L1) | |
| 4 | L4₹16.2 L+₹1.9 L (13.0%)Rejected-Finance | L4 | Rejected-Finance Other than (L1) | |
| 5 | L5₹16.6 L+₹2.2 L (15.2%)Rejected-Finance | L5 | Rejected-Finance Other than (L1) |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Jul 2023, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE(AF)EM Chakeri Kanpur
REPAIR MAINT OF AIR CONDITIONER AT ADM AND SEMI TECHNICAL AREA AT AF STATION KANPUR
2023_MES_604928_1
8628/E8
Open Tender
Civil Works
Item Rate
180 days
Area under GE(AF) EM Chakeri
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE (AF) E/M CHAKERI
₹40,000
Yes
25 Sept 2023
22 Jun 2023
31 Jul 2023
22 Jun 2023
27 Jul 2023
7 Jul 2023
Amount
M&L for servicing of Split type AC of capacity 1.5 TR (including Indoor and out door unit) at various locations complete by cleaning of filters, indoor cooling coil, condenser coil using chemical with spraying water and brushing, removing of dust, dirt from air conditioners all over check all electric connections, checking any leakage by applying soap solution on joints and liquid/ vapour lines properly. Checking of functionally of spares of air conditioners and replacing the defective items supplled under relevant item of schedule & rectifying the defects and put the air conditioners into operation complete all specified and directed. Note- (i)Spares shall be measured and paid seperately under relevant item of schedule. (ii) As the nature of work is of daily maintenance of air conditioners contractor should deploy adequate trained technicians with helpers as intimated by Engineer in charge to rectify the complaint within 48 hours of receipt of complaint failing which penalty of Rs 200 per complaint per Day till the rectification shall be charged from the contractor. (iii) Contractor will make own arrangement for transportation of Air conditioners from site to workshop. (iv) Record of AC serviced with respect to capacity and SM number shall be mentained and shall be submitted to Engineer in Charge.
All as per item no. 1 here in before but Split AC of capacity 2.0 TR
M&L servicing of window air conditioner 1/1.5 TR at various locations complete by cleaning/ filter/ condenser/ evaporator section using chemical with spraying water jet, and brushing, removing of dust/ dirt from air conditioner all over, check all electric connections, checking any leakage by applying soap solution on joints and liquid/ vapour lines properly. Checking of functionally of spares of air conditioners and replacing the defective items supply under relevant item of schedule & rectifying the defects and put the air conditioners into operation complete all specified and directed. Note- (i)Spares shall me measured and paid seperately under relevant item of schedule. (ii) As the nature of work is of daily maintenance of air conditioners contractor should deploy adequate trained technicians with helpers as intimated by Engineer in charge to rectify the complaint within 48 hours of receipt of complaint failing which penalty of Rs 200 per complaint per Day till the rectification shall be charged from the contractor. (iii) Contractor will make own arrangement for transportation of Air conditioners from site to workshop. (iv) Record of AC serviced with respect to capacity and SM number shall be mentained and shall be submitted to Engineer in Charge.
All as per item no.3 here in before but for window AC of capacity 2.0 TR
All as per item Sl No 3.00 but Tower AC of capacity 3.5 TR
Supply only starting relay 1.5/2.0/3.5TR complete all specified and directed. Make :Asian/Ellyt/Epcos/Renutrol
Supply only thermostste switch with knob suitable for Window AC complete all specified and directed.Make :Asian/Ellyt/Epcos/Renutrol
Supply only Contactor Relay for Tower AC of capacity up to 3.5TR, 415V, 50Hz, 3 Phase complete all specified and directed.Make :Asian/Ellyt/Epcos/Renutrol
M&L for disconnecting of u/s PCB from the unit of spit AC/ window AC transporting to market for repair /replacement of defective parts required to make serviceable and reinstalling with the unit and making connections complete all as specified and directed by Engineer in Charge.
M&L in replacement of burnt PCB from unit and supply & fix of new PCB of window AC of cap of 1.5/2.0TR of any make/model including testing and commissioning all as specified and directed by Engineer in Charge.
S&F in replacement of Metal clad socket industrial 2 pin & earth plug of 20 Amp, 230 volt complete suitable for AC Box all as specified, Make: Legrand/ABB/Havels
S&F in replacement of Metal clad plug industrial 2 pin & earth plug of 20 Amp, 230 volt complete suitable for AC Box all as specified, Make: Legrand/ABB/Havels
Supply only NRV suitable for window/split type AC of cap 1.5/2.0 TR complete all specified and directed. Make :ASIAN/ELLYT/EPCOS
S&F in replacement of MCB SP 240Volt, 32 Amp, 10KA, 'C' Curve complete all as specified, Make: Legrand/ABB/Havels
M&L in replacement of burnt PCB from unit and supply & fix of new PCB of Split Type AC of cap of 1.5/2.0TR of any make/model including testing and commissioning all as specified and directed by Engineer in Charge.
S&F Suction Valve 5/8" , ISI marked complete all as directed by Engineer in Charge.
S&F Suction Valve 1/4" , ISI marked complete all as directed by Engineer in Charge.
S&F Discharge Valve 3/8" , ISI marked complete all as directed by Engineer in Charge.
S&F Discharge Valve 1/2" , ISI marked complete all as directed by Engineer in Charge.
Supply only OLP relay suitable for 1.5/2.0TR AC complete all specified and directed. Make :Asian/Ellyt/Epcos/Renutrol
Supply only copper liquid line filter 3 way suitable for copper pipe of 3/8 dia for window/ split type complete all specified and directed.
S&F in replacement of Copper pipe 5/8" outer dia
S&F in replacement of Copper pipe 8/8" outer dia
S&F in replacement of Copper pipe 1/2" outer dia
S&F in replacement of Copper pipe 1/4" outer dia
S&F Flare nut 5/8" complete all specified and directed.
S&F Flare nut 3/8" complete all specified and directed.
S&F Flare nut 1/2" complete all specified and directed.
S&F Flare nut 1/4" complete all specified and directed.
S&F Dead nut 5/8" complete all specified and directed.
S&F Dead nut 3/8" complete all specified and directed.
S&F Dead nut 1/2" complete all specified and directed.
S&F Dead nut 1/4" complete all specified and directed.
S&F in replacement of copper pipe insulation of any size complete suitable suitable for Split/Tower AC all as specified and directed by Engineer in Charge.
M&L for disconnecting, disconnecting u/s compressor from Split/Window AC of cap 1.5TR and replacement with new HSCM compressor (Rotary type) on mountings such as rubber pads, nut bolts, washers and breezing suction and discharge line properly, making electrical connections, checking and leakage at jointss and vacccuming the system all as specified and directed by Engineer in Charge.
M&L for disconnecting, disconnecting u/s compressor from Split/Window AC of cap 2.0TR and replacement with new HSCM compressor (Rotary type) on mountings such as rubber pads, nut bolts, washers and breezing suction and discharge line properly, making electrical connections, checking and leakage at jointss and vacccuming the system all as specified and directed by Engineer in Charge.
M&L for disconnecting, disconnecting u/s compressor from Split/Window AC of cap 1.5TR and replacement with new HSCM compressor (Reciprocating type) on mountings such as rubber pads, nut bolts, washers and breezing suction and discharge line properly, making electrical connections, checking and leakage at jointss and vacccuming the system all as specified and directed by Engineer in Charge.
M&L for disconnecting, disconnecting u/s compressor from Split/Window AC of cap 2.0TR and replacement with new HSCM compressor (Reciprocating type) on mountings such as rubber pads, nut bolts, washers and breezing suction and discharge line properly, making electrical connections, checking and leakage at jointss and vacccuming the system all as specified and directed by Engineer in Charge.
M&L for disconnecting, disconnecting u/s compressor from Split/Window AC of cap 3.5TR and replacement with new HSCM compressor (Scroll compressor ), 415V, 50Hz, three phase on mountings such as rubber pads, nut bolts, washers and breezing suction and discharge line properly, making electrical connections, checking and leakage at jointss and vacccuming the system all as specified and directed by Engineer in Charge.
Supply only Refrigerent R-22 gas suitable for Split/Window type Air conditioner in empty cylinder at AGE EM-III Store Yard complete all a specified and directed by Engineer in Charge. Note:- (i) Empty cylinder will be provided by the department for filling up refrigerent. (ii) refrigerent purchase voucher should be provided by the contractor. (iii) The refrigerent shall be taken on ledger charge with receipt voucher and issued as per requirement complete all as specified and directed.
All as per item no. 40 here in before but R-32 refrigerent gas
All as per item no. 40 here in before but R-410 refrigerent gas
Supply only Running capacitor 2.5MFD, make Asian/Ellyt/Epcos
Supply only Running capacitor 4.0MFD, make Asian/Ellyt/Epcos
Supply only Running capacitor 6.0MFD, make Asian/Ellyt/Epcos
Supply only Running capacitor 36.0MFD, make Asian/Ellyt/Epcos
Supply only Running capacitor 45+6 MFD, make Asian/Ellyt/Epcos
Supply only Running capacitor 50+6 MFD, make Asian/Ellyt/Epcos
Supply only Running capacitor 55+6 MFD, make Asian/Ellyt/Epcos
Supply and fix in replacement Copper pipe 1/4 " outer dia complete all specified and directed.
M & L for transportaion of air conditioner from site to work shop for defecting leakage from the close circuit of window air conditioner 1/1.5/2.0 TR capacity, rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site.( Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates)
M & L for dismantling of indoor unit split Air conditioner of capacity 1.5/2 TR transporting from site to workshop for defecting leakage from the close circuit of split air conditioner of rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site.( Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates)
M & L for dismantling of outdoor unit split Air conditioner of capacity 1.5/2.0 TR transporting from site to workshop for defecting leakage from the close circuit of Tower air conditioner of rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site.
M & L for defecting leakage from the close circuit of Tower air conditioner of capacity 3.5 TR rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site.
M & L for charging of refrigerant R-22 in window / split AC of capacity 1/1.5/2.0/3.5 TR capacity , testing ,complete all as specified and directed.
All as per item Sl No 55.00 but charging of refrigerant R-410
All as per item Sl No 55.00 but charging of refrigerant R-32
M&L for disconnecting and dismentaling of blower/ condenser motor of window air conditioner of capacity 1.5 TR transporting to civil workshop and rewinding with super enamelled copper conductor wires of superior quality and assembling with the AC unit and testing and commissioning complete all as specitfied directed.
All as per item Sl No 58.00 but blower/ condenser motor of 2.0 TR window AC
All as per item Sl No 58.00 but blower/ condenser motor of out door unit of split type air conditioner of capacity 1.5 TR
All as per item Sl No 58.00 but blower/ condenser motor of out door unit of split AC 2.0 TR capacity
All as per item Sl No 58.00 but blower/ condenser motor of Tower AC 3.5 TR capacity
S&F in replacement of single phase electric motor AC of indoor unit capacity 1.5 /2.0 TR split AC as per existing make and sample as per site requirement all as specified and directed .
S&F in replacement of single phase electric motor DC of indoor unit capacity 1.5 /2.0 TR split AC as per existing make and sample as per site requirement all as specified and directed .
M & L for disconnecting and leak aluminium condenser coil from split air conditioner of capacity 1.5 TR and supply & Fixing of copper tube condenser coil of suitable size as per sample and make and fixing with the outdoor unit of air conditioner vaccuming the system complete and commissioning after fixing complete all as specified and directed.
All as per item Sl No 65.00 but for 2.0 TR air conditioner
S&F replacement sheet metal enclosure, 32 Amp single pole and nutral with a two pin and earth plug socket complete metal clad board (industrial type with MCB 32 Amp fix properly complete all specified and directed. Make: Legrand/Havels/L&T
M & L for factory made MS angle iron stand of suitable size to mount outdoor unit of capacity 1.5/2.0 TR split AC complete all as specified and directed.
Supply of Copper rod for brezzing complete all as specified & directed.
S & F Nylon stranded PVC flexible pipe Drain pipe of size 15 mm as per sample all as specified & directed.
S & F in replacement PVC insulated & sheathed round multi stranded copper conductor 1.5 sq mm 3 core 1100 Volts graded complete all specified and directed. Make : Plaza / Havells / Finolex
S & F in replacement PVC insulated & sheathed round multi stranded copper conductor 2.5 sq mm 3 core 1100 Volts graded complete all specified and directed. Make : Plaza / Havells / Finolex
Supply and fix in replacement indoor blower fan blade for Split AC of 1.5/2.0 TR capacity as per existing make and sample complete all specified and directed.
Supply and fix in replacement fan blade of condensor of out door unit for Split AC of 1.5/2.0 TR capacity as per existing make and sample complete all specified and directed.
Supply only Butane gas cartridge container not less then 230 grms or standard available in market for complete all specified and directed.
M & L shifting of split AC 1.5 TR/2.0 TR/ 3.5 TR with indoor unit , outdoor Unit, stabilizer to a new position as per requirement re-fixing and testing up to the satisfaction of Engr-In-charge mounting of split Air conditioner outdoor unit wall mounting stand for suitable size of 1.5/2.0/3.5 TR split AC complete all specified and directed. Note: Unit rate of this item included the cost of making necessary holes, drilling, screw etc and all electric and gas tube connection
S&F replacement of condenser fan motor including mounting base, rubber clips as per existing make and soft length in split type air conditioner 1.5/2.0 TR capacity as per make & sample complete all specified and directed.
S&F in replacement of relay 25/30 Amp ,240 Volt , cap of 4KVA Voltage Stablizer complete all as specified
All as per item no. 78 here in before but for 5KVA Voltage Stablizer complete
M&L for rewinding of burnt transformer of voltage stablizer of cap 4 KVA with supper enamel copper conductor winding wire and assembling with the stablizer complete all as specified and directed by Engineer in Charge.
All as per item no. 80.00 here in before but for 5KVA Voltage Stablizer complete
S & F in repair of main PCB with high and low voltage cut off PCB suitable for 4 KVA voltage stabilizer suitable making for existing complete all specified and directed.
All as per item no. 82 here in before but for 5KVA Voltage Stablizer complete
S&F in replacement of swing motor of any split /window type AC of cap 1.5/2.0 TR of existing make complete all as specified & directed by Engineer in Charge.
Supply & fix black insulation tap of 4" complete all as directed by Engineer in Charge
VISHAL TRADERS
Uma engineers
M/S NILESH ENTERPRISES
m/s A.A brothers
M/s Hanspal Enterprises
M/s A S Electrical
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .