Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC VILL KAMLAH PO BASARAL TEH NADAUN DISTT HAMIRPUR HP | NADAUN | HAMIRPUR | HIMACHAL PRADESH | ₹24.3 L | L1 | Accepted-AOC bidder found L1 |
| 2 | L2₹24.5 LRejected-Finance AT GROUND FLOOR MAIN BAZAAR MEHRE TEHSIL BARSAR DISTT HAMIRPUR H P PIN CODE 174305 | HAMIRPUR | HIMACHAL PRADESH | 174305 | ₹24.5 L | L2 | Rejected-Finance Bidder found L2 |
| 3 | Rejected-Technical CHIEF ENGINEER OP KANGRA ZONE HPSEBL DHARAMSHALA | KANGRA | HIMACHAL PRADESH | 175013 | - | - | Rejected-Technical techno-commercially not qualified |
| 4 | Rejected-Technical SANSARPUR TERRACE HIMACHAL PRADESH | - | - | Rejected-Technical techno-commerically not qualified |
| 5 | Rejected-Technical 25 INDUSTRIAL AREA PHASE II NAGROTA BAGWAN DISTT KANGRA H P | KANGRA | HIMACHAL PRADESH | 175013 | - | - | Rejected-Technical techno-commercially not qualified |
Tender Value
₹30.8 L
EMD Value
₹30,900
Closing Date
16 Feb 2026, 3:30 pmClosed
Superintending Engineer
Superintending Engineer operation circle hpsebl, hamirpur
SOP for Rajiv Gandhi Day Boarding School at Amlehar by providing 11 04kv 400KVA Sstn aw11KV HT Line including Survey Design Supply of Equipment Material Erection Testing and Commissioning in E Section Kohla UESD Nadaun The Nadaun Distt Hamirpur
2026_HPSEB_127875_1
HPSEBL/OCHMR/ NDN/E/2025-26-09
Open Tender
Electrical Works
45 days
Nadaun
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹30,900
7 Apr 2026
10 Feb 2026
17 Feb 2026
10 Feb 2026
16 Feb 2026
10 Feb 2026
1. SUPPLY PART : 1) DTR 400 KVA -Distribution Transformer (Ordinary), 11/0.4 kV, 400 KVA conforming to ISI & BEE Specifications.
9Mtr. Long ISI marked, Swaged Steel Tubular poles as per IS:2713 / 1980 (Part-I-III) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.
Muffs (2000mm) with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos]
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800mm) X 4 Nos]
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x4.8 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit
Surge Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Pipe Earthing Set
6 SWG GI wire For Earthing
LT Distribution Panel Box with ACB(630A, 50 kA, 4P,1 No) and SFU(100A, 6No, rewirable)
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated)
Aluminium Thimble 300 sq mm
Copper Thimble 95 sq mm
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 400 mm² incommer
LT Cable (3.5 Core) 300 mm² Outgoing
Energy Meter (3-Phase, 4-Wire) DLMS compliant 1000/5 A CT Type for 400KVA Transformer
a)Aluminium Paint.
b)Red oxide
LT Switched Capacitors 135- KVAr for 400 KVA
CT-PT Combined Unit [PT:11 kV/110 V) ; CT:10-400/5A]
3-phase, 3/4-Wire CT-PT operated Static Trivector Meter (DLMS Compliant)
i) PVC Multistrand 2.5 mm² copper wire
ii) 1 inch dia GI pipe for concealing
iii) bend joints/ elbow
11 kV Taping Point - 11 Mtr. Long ISI marked, Swaged Steel Tubular poles as per IS:2713/1980 (Part-I-III) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-56.
Muffs (2000mm) with concerete filling
X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 4 Nos]
X-Arm: [Channel Iron (75x40x4.8 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of CT-PT Unit]
MS Angle Iron (50X50x6 mm), Length: 2800 mm x1 Nos for LA's)
MS Angle Iron (50X50x6 mm), Length : 2800 mm x 4 Nos
MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
GO AB Switch Unit (11kV, 400A, 25 KA )
D.O Fuse Unit
Surge Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete (i/c Stay Clamp)
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Pipe Earthing Set
GI Wire 6 SWG For Earthing
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated)
Aluminium Thimble 70mm
Copper tinned thimble 35mm
Danger Plate
Barbed Wire
Red Oxide
Aluminium Paint.
11 kV HT Line -AAAC 7/4.26mm conductor 100 mm2 for 3Φ and Additional 1% (Sag, Jumpering and wastage}
11 Mtr. Long ISI marked, Swaged Steel Tubular poles as per IS:2713/1980 (Part-I-III) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-56.
Muffs (2000mm) with concerete filling
Run Thro' Structures Cross Arm: [Channel Iron (100x50x5 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators (Porcelain, 12 kV, 10 KN):
Dead End Structures- Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron C type: 100X50x5, Length: 2340 mm x 2 No.]
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps, Straight stapples & Bend Stapples etc.) x (3 No. conductors)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN):
Stay set complete in all respect (i/c Stay Clamp) (1No. / Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (9 kg Per Stay Set)
HT Earthing set complete
Single Continous Earth wire (GI, 8 SWG)
Eye Hook for earth wire
Earth Reel
MS Angle Iron: 50x50x6, Length : 2800 mm for Road crossing
Half clamps
Full clamps:
Danger Plate (250X200X1.6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated)
Barbed Wire
Red Oxide
Aluminium Paint
Sectionaliser (11kV, 400 A, 12.5KA, SF6/ Vaccum, Outdoor) With Remote Communication
CIVIL WORKS:- Transformer Bed / Construction of Concrete Cement Plateform (1:3:6) of Size (1.2x1.5x1.5) Mtr for installation of 400 KVA, 11/0.4KV Transformer including providing of material i.e. i) 0.54Cum Concrete 1:3:6, ii) 2.16 Cum Concrete 1:1.5:3 iii) MS/Tor Steel reinforcement 175Kg. iv) MSCI 21.42Kg & cement Plaster 15mm Thick including Excavation & Form work etc. complete in all respect as per technical specifications and drawings.
Providing and fixing of GI Chain link febric fencing 6.6 Mtr x 3.8 Mtr x 2Mtr of required width in mesh size 50x50mm fencing with Gate of of size 1x2Mtr made of MS Steel angle Iron including providing of material i.e. i) 0.40Cum Concrete 1:4:8, ii) 68Kg Structural steel work in single section iii) 83.73Kg Steel work welded in built up section iv) 41.60 m² - GI Wire mesh 50x50mm ,4mm dia wire including Painting with synthetic enamel paint of approved brand & erection etc complete in all respect.
Sub-Station Erection Part:- Erection of 11/0.4KV, 400 KVA Sub-Station Structure using Steel Tubular Poles a/w RCC Muff & its concrete filling as per latest standard practices /specification of REC / HPSEBL including digging of pits, erection of Poles & Muffs, Filling muffs with PCC mixture, re-filling of pit & ramming, drilling of holes in Cross X Arms, Preparation of Plateform Structure Members MS Channel X Arms and Knee Bracing Sets, Erection of Plateform, fixing of M.S. Cross Arms S/Stn fitting, Painting of Complete structure with red oxide paint & then alluminium paint, fixing of GO Switch, DO fuse units, Lightening Arrestors, Disc Insulators, Pin Insulators, LT Ditribution Panel, Energy Meter. Erection of S/Stn. Pipe Earthing Set (3Nos.) complete in all respect including providing Char Coal, Salt etc., Erection of Transformer, Providing Earthing Connection to GO Switch, Transformer, Lighteneing Arrestor etc. Erection of Stay Sets, Erection of LT Cable and fixing of jumpers. Testing and commissioning of Transformer and allied equipments complete in all respect.
ERECTION OF 11KV HT LINE : Erection of Single Pole Run through Structure with Steel Tubular Pole 11Mtr Long as per latest standard practices /specification of REC / HPSEBL : (including Digging of pit for poles, muffing of pole, drilling of holes in poles and X-arms ,fixing of insulators,X-arms, erection of poles, fixing of barbed wire,danger plate,filling of pit ramming and painting painting of structure with Redoxide Primer & then with Aluminium Paint etc.Complete in all respect.
Erection of Double Pole / Dead Pole Structure with Steel Tubular Pole 11Mtr Long as per latest standard practices /specification of REC / HPSEBL : (including Digging of pit for poles, muffing of pole, drilling of holes in poles and X-arms ,fixing of insulators,X-arms, erection of poles, fixing of barbed wire,danger plate,filling of pit ramming and painting painting of structure with Redoxide Primer & then with Aluminium Paint etc.Complete in all respect.
Erection of HT Earthing Set as per latest standard practices /specification of REC / HPSEBLincluding digging of pit of size 1.80x 1.2 x1.2 Mtrs, fixing of HT Earth Set, refilling the same and prov. earthing connection complete in all respect.
Erection of Stay Set (HT) as per latest standard practices /specification of REC / HPSEBL including Digging of pit (size0.9x0.7x1 .5 M),fixing of Stay Rod, filling and ramming of pit, nozzelling and tightening etc. complete in all respect.
Laying of Conductor, Stringing, Sagging of AAAC, 100mm² 7/4.26mm² and binding with Insulators (3 wires) and fixing of jumper.
Erection of Continous Earth Wire / Guaring wire i.e. Laying of GI Wire 8SWG , Stringing, Sagging of and binding with Insulators including erection of Guarding wire & Cross Lacings etc. at road crossings/ where ever necessary.
Erection Charges of fixing of Jumpers of 11Kv line as per latest standard practices /specification of REC / HPSEBL (Per Set).
Tapping Pole Erection:-Erection of Double Pole / Dead Pole Structure with Steel Tubular Pole 11Mtr Long as per latest standard practices /specification of REC / HPSEBL : (including Digging of pit for poles, muffing of pole, drilling of holes in poles and X-arms ,fixing of insulators,X-arms, erection of poles, fixing of barbed wire,danger plate,filling of pit ramming and painting painting of structure with Redoxide Primer & then with Aluminium Paint etc.Complete in all respect.
Tapping point Erection Part :- Erection of CT PT Combined Unit (outdoor type) 11KV/110V, 200/5Amps, accuracy Class 0.5s, ISI Mark conforming BEE specification.
Erection of HT Earthing Set as per latest standard practices /specification of REC / HPSEBLincluding digging of pit of size 1.80x 1.2 x1.2 Mtrs, fixing of HT Earth Set, refilling the same and prov. earthing connection complete in all respect.
Erection of Stay Set (HT) as per latest standard practices /specification of REC / HPSEBL including Digging of pit (size0.9x0.7x1 .5 M),fixing of Stay Rod, filling and ramming of pit, nozzelling and tightening etc. complete in all respect.
Erection of GO AB Switch Unit complete in all respect
Erection of DO Fuse Unit
Installation of 11 kV line sectionalizer complete in all respect
4. OTHER CHARGES: Transportation Charges for the carriage material by road & manual carriage to the site of work for Rajiv Gandhi Day Boarding School at Amlehar (Complete Job)
Testing fees & Commissioning Charges etc. for newly constructed 400KVA S/Stns a/w 11KV HT,LT & CT-PT unit Lines to provide SOP Rajiv Gandhi Day Boarding School at Amlehar (Complete Job).(as per Schedule of General & Service Charges & HP Govt. Notification)
Labour Cess (@ 1% of the total amount of the supply, erection, testing & commissioning for newly constructed 400KVA S/Stns a/w 11KV HT,LT & CT-PT unit Lines to provide SOP for Rajiv Gandhi Day Boarding School at Amlehar (ED Nadaun) (for complete Job).
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.15 MB
Tenderdocument09.rar
Tender Documents • 20.98 MB
BOQ_188894.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid