Executive Engineer (Elect)-I
OFFICE OF THE Ex. ENGINEER (ELECT)-I, SHAHDARA (N) ZONE, KeshavChowk, Delhi-110053
For annual repair and comprehensive AMC of tubewells installed in various municipal Schools in ward no 216 to 220 and 225 236 under EEE-I , Shahdara (North) Zone.
2026_MCD_273083_1
EE(E)-I/Sh.N/MCD/25-26/TC-64/1
Open Tender
Electrical Works
Percentage
365 days
As per NIT
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
₹24,500
31 Mar 2026
25 Mar 2026
30 Mar 2026
25 Mar 2026
30 Mar 2026
25 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Development of tube well with suitable capacity of air compressor i/c lowering of the , necessary induction pipe or line i/c cost of fuel, hire charges of compressor etc as reqd. The development shall be considered complete when Gravel stop sinking, Discharge ceased to improve and the sand contents are not more than 10 PPM after 20,minutes of starting the pump complete as reqd. | |||||
| 2Supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc. as reqd. Single Phase 1.5 HP having discharge of 72 LPM Approx. at 49 M Head. | |||||
| 3Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three Phase submersible pumping set of following rating complete with contactor, relay, MCB, condenser, voltmeter, ammeter and indication lamp etc including connections etc as reqd. 1.5 HP (Single Phase) | |||||
| 4P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd. 3x 2.5 sq.mm | |||||
| 5Supply, lowering and fixing following size of G.I. Pipe (M-Class) i/c cutting threading on both sides etc. ISI marked etc as reqd. 32mm(Nominal Bore) | |||||
| 6Rewinding of single/three phase AC motors of vertical type multi stage submersible pump set of following rating :- (a)single phase 1 and 1.5 HP | |||||
| 7 | Replacement of following items for cubicle panel etc as required (a) Capacitor 36 mfd. | 52 | Each | - | - |
| 8Lifting the existing submersible pump set with its all acessories from well and lowering the same along with all accessories for the depth up to 50 meter complete as required. | |||||
| 9 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required.(a)40 Amp. | 28 | Each | - | - |
| 10Repairing of the Pumping unit of 1/1.5/3 HP vertical type, multistage, submersible pump set by replacement of following accessories/parts etc compete as reqd.(a) Gun Metal Bush / Bearing. | |||||
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
ConditionAMCtubwellMCP.pdf
Tender Documents • 3.10 MB
Circular_1.pdf
Tender Documents • 2.39 MB
GCC2024.pdf
Tender Documents • 9.36 MB
BOQ_318704.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .