TECHNICAL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of [V/N or 'V' whichever is less; where V = Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The Similar nature of works for this instant tender shall be "Supply, installation, testing and commissioning of any LT/HT electrical work." The tenderer should have executed the similar nature of works in Central/State Government department or PSUs of Central /State Government."
Tenderer must have to submit valid Electrical Contractor license as per Indian Electricity Rules for the respective category of works issued by Government Electrical License Board on or before the closing date of tender. Copy of the electrical contractor license should be submitted along with the tender offer, otherwise, the tender will be summarily rejected.
52 conditions · 2 needing a document upload
Whether the cost of earnest money deposited
WHETHER VALID ELECTRICAL CONTRACTOR LICENCE SUBMITTED
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Electrical work for Schedule A:At LMG: re-wiring of Crew lobby, Lumding, Schedule B: At LMG: Rewiring of Retiring room, C&W office, Train Lighting office(ETS) of Lumding at P. F. No. 4, Schedule C: At LMG: rewiring of swimming pool lighting of Officer Rest House, LMG, Schedule D: At SCL: Rewiring of Sr.DEN OFFICE BUILDING/SCL, Schedule E: At SCL: Rewiring of OFFICERS REST HOUSE (NEW), SCL, Schedule F: At SCL: Rewiring of OFFICERS REST HOUSE (OLD), SCL, Schedule G:- At LMG:Provision of Electrical Wiring and Associated Works for Newly Created Sr. DMM Office in DRM Complex.
EL-LM-25-26-44
EL-LM-25-26-44
Open
Works - General
120 Days
Hojai, Assam
₹0
₹1.6 L
10 Apr 2026
16 Mar 2026
27 Mar 2026
257 items across 7 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 13,66,991.83 | ||
| — | 30.00 | — | — | ||
| Supply, wiring, installation, testing and commissioning of light point through good quality hard PVC casing-capping with all associated accessories for surface wiring, using 1.5 sq.mm single core PVC insulated flexible stranded copper conductor. The point shall be controlled through flush type 5/6 A modular switch mounted on hard plastic moulded board. PVC casing-capping shall be neatly fixed on wall/ceiling using MS screws (6x40 mm) at spacing not exceeding 300 mm centre- to-centre. Work includes proper termination, dressing of wires, continuity and insulation testing, and making the point fully functional complete as directed by the Engineer-in-Charge and conforming to relevant IS specifications | — | — | — | 5,067.9 | |
| — | 6.00 | — | — | ||
| Supply and wiring of ceiling fan point through good quality hard PVC casing with associated accessories for surface type wiring by 1.5 mm sq single core PVC insulated flexible copper cable with earth continuity by 16SWG bare copper wire and flush type 5/6 amp controlling switch to be provided on hard plastic moulded board including 300W box type stepped electronic fan regulator.Ceiling fan connection shall be done through ceiling rose. Casing shall be fixed on the wall / ceiling by MS (6x40 mm) screw at an interval not more than 300mm.Work includes proper termination, dressing of wires, continuity and insulation testing, and making the point fully functional complete as directed by the Engineer-in-Charge and conforming to relevant IS specifications. | — | — | — | 1,658.28 | |
| — | 140.00 | — | — | ||
| Supply and wiring of 5/6 amp, 5 pin plug point through good quality hard PVC casing with associated accessories for surface type wiring by 1.5 mm sq single core PVC insulated flexible copper cable with earth continuity by 16 SWG bare copper wire and flush type 5/6 amp controlling switch to be provided on hard plastic moulded board.Casing shall be fixed on the wall / ceiling byMS (6x40 mm) screw at an interval not more than 300mm.Work includes proper termination, dressing of wires, continuity and insulation testing, and making the point fully functional complete as directed by the Engineer-in-Charge and conforming to relevant IS specifications. | — | — | — | 23,627.8 | |
| — | 20.00 | — | — | ||
| Supply and wiring of 15/16 amp, 6 pin plug point through good quality hard PVC casing with associated accessories for surface type wiring by 4 mm sq single core PVC insulatedflexible copper cable with earth continuity by16 SWG bare copper wire and flush type15/16 amp controlling switch to be provided on hard plastic moulded board. Casing shallbe fixed on the wall / ceiling by MS (6x40mm) screw at an interval not more than300mm .Work includes proper termination, dressing of wires, continuity and insulation testing, and making the point fully functional complete as directed by the Engineer-in-Charge and conforming to relevant IS specifications | — | — | — | 5,977.6 | |
| — | 15.00 | — | — | ||
| Supply, fitting, fixing, connection and commissioning of 18/20 W LED indoor light fitting complete with LED tube and all accessories. The fitting shall be connected with 1.5 sq.mm PVC insulated flexible copper wire through PVC pipe/casing-capping as required at site, including all necessary connections, fixing, testing and commissioning complete as directed by the Engineer-in- Charge. | — | — | — | 4,713 | |
| — | 20.00 | — | — | ||
| Supply of 18/20 W LED indoor light fitting complete set including LED tube, driver, housing, mounting accessories etc. suitable for 230 V AC supply. The item shall be delivered at site/store in good condition conforming to relevant IS specifications. | — | — | — | 6,284 | |
| — | 5.00 | — | — | ||
| Supply and fitting of 7 W LED bulb (cool daylight - 6500 K) suitable for operation on 230 V, 50 Hz AC supply, complete with required lamp holder and fixing accessories, including proper mounting, connection and making the fitting functional as directed by the Engineer-in-Charge. | — | — | — | 700 | |
| — | 5.00 | — | — | ||
| Supply of 7 W LED bulb having colour temperature 6500 K (cool daylight), suitable for operation on 230 V, 50 Hz AC supply, complete in all respects with cap/holder compatibility as required, conforming to relevant IS/BIS specifications. The item shall be delivered at site/store in good condition. | — | — | — | 700 | |
| — | 15.00 | — | — | ||
| Supply, installation, testing and commissioning of surface/recessed type LED luminaire having slim line CRCA sheet steel powder-coated housing, square/round configuration, system wattage 18 W with cool daylight colour temperature 6500 K and nominal system efficacy 100 lm/W. The luminaire shall have power factor 0.9, THD 20%, CRI 80 and minimum IP20 protection. The fitting shall be suitable for mounting in 600 x 600 mm modular false ceiling grid or for surface mounting as directed by the Engineer-in-Charge.. | — | — | — | 21,000 | |
| — | 15.00 | — | — | ||
| Supply of surface/recessed type LED luminaire having slim line CRCA sheet steel powder-coated housing, square/round configuration, system wattage 18 W with cool daylight colour temperature 6500 K and nominal system efficacy 100 lm/W. The luminaire shall have power factor 0.9, THD 20%, CRI 80 and minimum IP20 protection, suitable for mounting in 600 x 600 mm modular false ceiling grid or for surface mounting. The item shall be supplied complete with LED driver and standard mounting accessories, conforming to relevant IS/BIS specifications and manufacturer standards, and shall be delivered at site/store in good condition. | — | — | — | 21,000 | |
| — | 6.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor 1400 mm, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374- 2019), THD (Total Harmonic Distortion) less than 10%, suitable foroperation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. | — | — | — | 13,764 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of call bell point complete with surface wiring through hard PVC casing-capping using 1.5 sq.mm single core PVC insulated flexible copper conductor cable of approved make, including flush type 5/6 Amp call bell push switch mounted on hard PVC board, and approved quality 230 V AC ding-dong type call bell with all accessories such as bends, tees, screws, rawl plugs etc. as required for proper completion of work to the satisfaction of Engineer-in-Charge. | — | — | — | 658.64 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of exhaust fan point complete with surface wiring carried out through good quality hard PVC casing-capping of suitable size including all accessories such as bends, tees, couplers etc., using 1.5 sq.mm single core PVC insulated flexible copper conductor cable of approved make along with earth continuity provided by 16 SWG bare copper wire. The point shall include provision and fixing of flush type 5/6 Amp controlling switch mounted on hard plastic moulded board. Connection to exhaust fan shall be made through ceiling rose complete. The casing-capping shall be fixed on wall/ceiling using MS screws (6x40 mm) at intervals not exceeding 300 mm. The work shall be complete in all respects to the satisfaction of Engineer-in-Charge. | — | — | — | 549.32 | |
| — | 2.00 | — | — | ||
| Supply, installation, fitting, fixing, connection, testing and commissioning of 300 mm sweep heavy duty exhaust fan of approved make, suitable for operation on 230 V, 50 Hz AC supply, complete with mounting arrangement, necessary clamps / brackets, nuts & bolts, rawl plugs and all fixing materials. The work shall include making electrical connection from existing exhaust fan point, proper alignment, smooth operation testing and commissioning. All consumables required for proper fixing and installation shall be supplied by the contractor as per site requirement and as directed by the Engineer-in-Charge. | — | — | — | 2,614.3 | |
| — | 1.00 | — | — | ||
| Supply, fabrication, installation, testing and commissioning of dust-proof, vermin- proof, rodent-proof and weather-proof LT floor mounted cubicle type double door 'G' frame panel board fabricated out of 2 mm thick CRCA sheet steel, duly chemically treated and dry powder coated, mounted on suitable size MS channel/angle iron base frame. The panel shall be complete with 4-way, 400 Amp, 4-pole electrolytic grade copper bus bar system with adequately rated three phase and neutral copper busbars, cable alleys, metering compartment/module and all internal interconnections carried out using suitable size copper bus strips / copper cables with proper termination and insulation. The panel shall be provided with separate busbar chamber, gland plates, earthing studs, space heaters (if required), danger notice plate and all necessary hardware for safe and reliable operation. The fabrication drawing / GA drawing of the panel board shall be got approved from the competent authority / Engineer-in-Charge prior to fabrication and installation. The panel shall be painted with two coats of zinc chromate primer followed by two coats of approved shade exterior synthetic / epoxy paint applied by spray painting process. The work shall be complete in all respects including placement, alignment, grouting (if required), earthing connection, testing and commissioning to the satisfaction of Engineer-in-Charge. | — | — | — | 72,195 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of 250 Amps, 4 Pole MCCB having short circuit breaking capacity 36 kA at rated voltage, with Ics = 100% of Icu, provided with adjustable thermal and magnetic trip settings, conforming to IEC 60947-2. The MCCB shall be suitable for mounting inside LT panel / distribution board (mentioned in item no 15 of schedule A )and shall be complete with all required fixing accessories, spreader links, terminal shrouds and necessary connections for proper operation, as directed by the Engineer-in-Charge | — | — | — | 41,880 | |
| — | 2.00 | — | — | ||
| Supply, erection, fitting, fixing, connection, testing and commissioning of 63 Amps, 4 Pole MCCB having short circuit breaking capacity 25 kA at rated voltage with Ics = 100% of Icu, provided with adjustable thermal and magnetic trip settings, conforming to IEC 60947-2. The MCCB shall be complete with all necessary mounting hardware, spreader links, terminal shrouds and suitable size interconnections for proper installation inside LT panel / distribution board(mentioned in item no 15 of Schedule A), as required and as directed by the Engineer-in-Charge. | — | — | — | 26,260 | |
| — | 1.00 | — | — | ||
| Supply, erection, fitting, fixing, connection, testing and commissioning of pre-wired analog metering module suitable for LT panel mounting(Suitable for item no 15 of schedule A), comprising of suitably rated AC voltmeter and ammeter with selector switches, necessary current transformers (CTs) of appropriate ratio and accuracy class, control fuses, phase indicating lamps with holders, internal wiring with FRLS copper conductor, terminal blocks and all mounting accessories. The module shall be complete with interconnections, termination, insulation testing and functional checking for proper operation, as directed by the Engineer-in-Charge. | — | — | — | 22,010 | |
| — | 1.00 | — | — | ||
| Supply, fixing, installation, testing and commissioning of 8-way vertical type Distribution Board (DB) with MCCB incomer and (8+8+8) outgoing modules, conforming to IS 8623 (Part-1 & 3) / IEC 61439 (Part-1 & 3), IK-08 impact resistance, fabricated out of CRCA sheet steel, powder coated in RAL-9003 shade, single door, IP-43 protection suitable for wall recessed / concealed mounting. The DB shall be complete with the following switchgear and accessories: (i) 200 Amps, 4 Pole MCCB incomer, breaking capacity 36 kA with Ics = 100% of Icu, adjustable thermal magnetic trip, conforming to IEC 60947-2 - 01 No. (ii) 20 Amps SP MCB, C-curve - 10 Nos. (iii) 16 Amps DP MCB, C-curve - 03 Nos. (iv) 10 Amps SP MCB, C-curve - 10 Nos. The DB shall include internal copper busbar system of adequate rating, neutral link, earth bar, interconnections, blanking plates, DIN channels, cable entry provisions, glands (if required), proper identification ferrules and all mounting hardware. The work shall include proper concealed mounting on wall including necessary cutting, making, finishing and restoration of surface, termination of incoming and outgoing cables, insulation resistance testing and functional testing complete to the satisfaction of the Engineer-in- Charge. All minor materials and consumables required for proper execution of work shall be supplied by the contractor | — | — | — | 64,867 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of 5 kVA Online UPS based on IGBT- PWM technology, suitable for operation on single phase AC input voltage range 160-260 V, 50 Hz and delivering regulated single phase output of 230 V ±1% at 50 Hz. The UPS shall have overall efficiency not less than 80% and shall be provided with inbuilt isolation transformer, pure sine wave output and zero transfer time. The UPS shall be complete with static bypass arrangement, necessary protections such as overload, short-circuit, battery deep discharge and input/output fault protection, digital indication / display for operating parameters, input-output terminals, earthing provision and all mounting accessories. The work shall include proper placement, connection with input supply and load side, earthing, testing of performance parameters and commissioning complete in all respects to the satisfaction of the Engineer-in-Charge. | — | — | — | 45,650 | |
| — | 8.00 | — | — | ||
| Supply, installation, connection, testing and commissioning of 12 V, 150 Ah Sealed Maintenance Free (SMF) battery conforming to JIS C 8702 (Part-1, 2 & 3) with latest amendments, suitable for UPS / inverter application. The battery shall be complete with inter-cell connectors, terminal hardware, identification labels and all necessary accessories for proper installation. The work shall include placement on existing / supplied battery rack or suitable base, tightening of terminals, polarity checking, voltage testing, charging and functional testing. All minor materials and consumables required for proper fixing, connection and commissioning shall be supplied by the contractor as per site requirement and as directed by the Engineer-in-Charge | — | — | — | 1,51,200 | |
| — | 1000.00 | — | — | ||
| Laying, commissioning of LT/HT cable XLPEinsulated power cables with armoured aluminum conductors of different sizes partly along the pole andpartly through ground in cable trench.Loading, unloading & carrying of cable toactual work site by contractor own arrangement as per instruction of Engineer incharge at site. | — | — | — | 40,930 | |
| — | 70.00 | — | — | ||
| Making of cable trench dimension 300 mm wide and 1000mm deep by excavation of earth. The cable shall be protected by laying of brickin 3 sides with filling of sand as per the direction of Engineer in charge at site (Outside track crossing) and back filling of earth/ ballast.The work to be executed as per enclosed specification. | — | — | — | 3,552.5 | |
| — | 150.00 | — | — | ||
| Supply and laying of 63 mm dia HDPE pipe of pressure rating PN-6.0 (6 kgf/cm²), of approved make, along pole / beam / bracket with suitable 25x5 mm MS clamps including nuts, bolts and washers, and partly underground in trench of depth up to 1 metre wherever required. The work shall include excavation, dressing, proper alignment, backfilling and restoration of surface to original condition. The scope shall also include supply and fixing of necessary HDPE compression sockets, short radius compression bends, end caps and all required accessories for proper routing and continuity of the pipe as per site requirement and as directed by the Railway Engineer. The materials shall be offered for pre-inspection by the Railway Engineer before laying. The cable / duct laying shall be carried out as per the instruction of the Engineer-in-Charge. | — | — | — | 14,814 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing and commissioning of pipe earthing complete with B- class GI pipe earth electrode of 4000 mm length, 50 mm nominal bore and 3.6 mm wall thickness, provided with tapered / pointed lower end for easy driving into ground. The earth electrode shall be provided with welded GI strip of suitable size and necessary clamping arrangement. The earthing arrangement shall include provision of funnel with perforated GI plate at the top of the pipe for watering, homogeneous backfilling with selected earth / soil. In locations of high soil resistivity or rocky strata, approved earth resistivity enhancing compound such as bentonite or equivalent shall be used as directed by the Engineer-in-Charge. The connecting earth continuity conductor from earth electrode to distribution panel shall be GI wire not smaller than 8 SWG or equivalent GI strip capable of carrying the fault current. The earthing pit shall be provided with precast RCC earth chamber / earth box with CI / RCC cover complete with all accessories. The scope shall include excavation, driving of pipe electrode, welding / connection, watering arrangement, backfilling, dressing of surface, measurement of earth resistance using approved earth tester and painting of measured earth resistance value along with date of measurement on the earth pit cover / lid. The work shall be executed complete in all respects as per approved drawing No. PCEE/ELG/DRG/2024/1/Rev-1 dated 28.07.2025 and Technical Circular No. EL/PS/2025/1 (Pipe Earthing Arrangement) and to the satisfaction of the Engineer-in-Charge | — | — | — | 4,061.43 | |
| — | 1.00 | — | — | ||
| Supply and wiring of 16 amp, 6 pin Inverter point through good quality hard PVC casing with associated accessories for surface type wiring by 4 mm sq single core PVC insulatedflexible copper cable with earth continuity by16 SWG bare copper wire and flush type15/16 amp controlling switch to be provided on hard plastic moulded board. Casing shallbe fixed on the wall / ceiling by MS (6x40mm) screw at an interval not more than 300mm. | — | — | — | 298.88 | |
| — | 7.00 | — | — | ||
| Supply, fitting, fixing, connection, commissioning and wiring of AC point by good quality accessories with proper connection complete with 16 amps MCB and plug point wiring by 6 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. | — | — | — | 3,673.18 | |
| — | 6.00 | — | — | ||
| Supply, installation, fitting, fixing, testing and commissioning of 1.5 Ton capacity, 5 Star rated, split type air conditioner suitable for operation on 230 V, 50 Hz single phase AC supply, having 100% copper condenser and evaporator coils. The unit shall be complete with indoor and outdoor units, hermetically sealed compressor, factory charged refrigerant, copper refrigerant piping of suitable size with nitrile / elastomeric insulation, PVC drain piping, interconnecting control cable, MS mounting brackets / stand for outdoor unit, vibration pads and all necessary accessories required for proper installation. The work shall include core cutting (if required), proper mounting, routing and clamping of copper pipes and cables, earthing connection, gas charging / topping up (if required), trial run, performance testing and commissioning complete in all respects to the satisfaction of the Engineer-in-Charge. The equipment shall be supplied with minimum 01 (one) year comprehensive warranty and 10 (ten) years warranty on compressor. The contractor shall be responsible for rectification / troubleshooting of any defects during the warranty period. | — | — | — | 2,81,400 | |
| — | 6.00 | — | — | ||
| Supply, installation, fitting, fixing, testing and commissioning of 2.0 Ton capacity, 5 Star rated, split type air conditioner suitable for operation on 230 V, 50 Hz single phase AC supply, having 100% copper condenser and evaporator coils. The unit shall be complete with indoor and outdoor units, hermetically sealed compressor, factory charged refrigerant, copper refrigerant piping of suitable size with nitrile / elastomeric insulation, PVC drain piping, interconnecting control cable, suitable MS mounting brackets / outdoor stand, vibration isolators and all accessories required for proper installation. The work shall include necessary core cutting / wall opening (if required), proper routing, clamping and dressing of refrigerant pipes and cables, earthing connection, gas charging / topping up (if required), trial run, performance testing and commissioning complete in all respects to the satisfaction of the Engineer-in-Charge. The equipment shall be supplied with minimum 01 (one) year comprehensive warranty and 10 (ten) years warranty on compressor. The contractor shall be responsible for attending faults / troubleshooting during the warranty period. | — | — | — | 2,95,506 | |
| — | 12.00 | — | — | ||
| "Supply, fabrication, fitting and fixing of outdoor stand for room air conditioner (RAC) fabricated out of suitable size MS angle / channel, duly drilled, welded and painted with one coat of red oxide primer and two coats of approved synthetic enamel paint. The stand shall be suitable for mounting outdoor unit of split air conditioner of required capacity and shall be fixed on wall / floor with necessary foundation bolts, clamps, nuts, washers and all fixing accessories complete as directed by the Engineer-in-Charge. | — | — | — | 11,880 | |
| — | 12.00 | — | — | ||
| Supply, installation, fitting, connection, testing and commissioning of 5 kVA capacity automatic voltage stabilizer suitable for operation of 1.5 / 2.0 Ton split air conditioner, compatible with 230 V, 50 Hz single phase AC supply. The stabilizer shall have suitable input voltage range, time delay protection, overload and short-circuit protection, digital / analog indication (as applicable) and shall be complete with wall / floor mounting arrangement, input-output terminals and all required accessories. The work shall include proper mounting, connection with power supply and air conditioner load, earthing provision, functional testing and commissioning complete in all respects to the satisfaction of the Engineer-in-Charge. | — | — | — | 62,400 | |
| — | 4.00 | — | — | ||
| Supply, fitting, fixing, installation, connection, testing and commissioning of 12-way modular switch board comprising high-grade polycarbonate modular plate with suitable size concealed / surface mounting GI / PVC box, complete with provision and fixing of required modular switches, socket outlets, LED indicators and suitably rated MCB(s). The work shall include internal wiring using FRLS copper conductor, termination of incoming and outgoing cables, earthing connection, dressing of wiring, fixing of cover plate and all necessary accessories such as screws, rawl plugs, connectors etc. required for proper installation. The switch board shall be installed at designated location and made functional complete in all respects to the satisfaction of the Engineer- in-Charge. | — | — | — | 5,564 | |
| — | 50.00 | — | — | ||
| Supply, fitting, fixing, installation, connection, testing and commissioning of 8-way modular switch board comprising high-grade polycarbonate modular plate with suitable size concealed / surface mounting GI / PVC box, complete with provision and fixing of required modular switches, socket outlets, LED indicators and suitably rated MCB(s). The work shall include internal wiring using FRLS copper conductor, termination of incoming and outgoing cables, earthing connection, proper dressing of wiring and fixing of cover plate. The item shall also include supply of all minor materials and accessories such as screws, rawl plugs, connectors etc. required for proper installation and making the switch board functional complete in all respects to the satisfaction of the Engineer-in-Charge. | — | — | — | 51,600 | |
| — | 15.00 | — | — | ||
| Supply, fitting, fixing, installation, connection, testing and commissioning of 6-way modular switch board comprising high-grade polycarbonate modular plate with suitable size concealed / surface mounting GI / PVC box, complete with provision and fixing of required modular switches, socket outlets, LED indicators and suitably rated MCB(s). The work shall include internal wiring using FRLS copper conductor, termination of incoming and outgoing cables, earthing connection, proper dressing of wiring and fixing of cover plate. The item shall also include supply of all minor materials and accessories such as screws, rawl plugs, connectors etc. required for proper installation and making the switch board functional complete in all respects to the satisfaction of the Engineer-in-Charge | — | — | — | 13,935 | |
| — | 20.00 | — | — | ||
| Supply, fitting, fixing, installation, connection, testing and commissioning of 4-way modular switch board comprising high-grade polycarbonate modular plate with suitable size concealed / surface mounting GI / PVC box, complete with provision and fixing of required modular switches, socket outlets, LED indicators and suitably rated MCB(s). The work shall include internal wiring using FRLS copper conductor, termination of incoming and outgoing cables, earthing connection, proper dressing of wiring and fixing of cover plate. The item shall also include supply of all minor materials and accessories such as screws, rawl plugs, connectors etc. required for proper installation and making the switch board functional complete in all respects to the satisfaction of the Engineer-in-Charge | — | — | — | 16,680 | |
| — | 1.00 | — | — | ||
| Supply, fabrication, fitting and fixing of MS storage rack of overall size approximately 6 ft (L) x 8 ft (H) x 6 ft (D) for keeping walkie-talkies, fabricated out of suitable size MS angle / channel / sheet steel sections, duly welded, ground smooth and structurally rigid. The rack shall be designed to provide 120 individual compartments arranged in 10 rows and 12 columns, complete with necessary partitioning, base support and strengthening members. The rack shall be finished with one coat of red oxide primer followed by two coats of approved synthetic enamel paint. The work shall include proper placement, anchoring / fixing to floor or wall (if required) with foundation bolts, nuts, washers and all necessary accessories for safe and stable installation complete as directed by the Engineer-in-Charge. | — | — | — | 28,320 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-LM-25-26-44-works-.pdf
ATTACHMENT
GCCACS1113.03.2026.pdf
ATTACHMENT
GCCACS1113.03.2026.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .