Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 01 BOKAKHAT UDAYNAGAR GOLAGHAT ASSAM 785612 | GOLAGHAT | ASSAM | 785612 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical No valid electrical license, pl refer TR |
Tender Value
Refer Docs
Closing Date
20 Aug 2021, 11:00 amClosed
Kaveri Hazarika 9435703123
Numaligarh Refinery Limited
Shifting of 33/11KV receiving power transformer and related electrical works at NRL Site
2021_NRL_639988_1
OC10000417/KAV
Open Tender
Miscellaneous Works
Works
180 days
Numaligarh Refinery Limited
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
20 Sept 2021
23 Jul 2021
21 Aug 2021
23 Jul 2021
20 Aug 2021
6 Aug 2021
Amount
Supply of 33KV incoming outgoing isolating breaker panel with CTs,PTs,numerical relays,transformer protection relays, relays for OTI,WTI,Buchholz,MOG,auxiliary relays,multi function meters. Detail specification as per Annexure-1 of Technical Specifications
Installation of 33KV ICOG panel at location inscluding proper alignment,earthing connection, power and control cable termination and make ready the panel for charging. The job shall also include necessary testing like primary injection,secondary injection,HiPOT test to be carried out in the panel.
Supply of GI Earth Strip Size:75X10mm Galvanised with hot dip process Galvanisation thickness:610gm per Sqmtr. Avearge dft:86 microns Conforms to IS:2629/4759 The quoted items should be as per IS: 3043 Recommended practice for hot dip galvanized of Iron Earthing Strips IS: 2629(1966) Methods of testing weight, thickness & uniformity of coating on hot dip galvanized articles IS: 2633(1972) Specification for hot dip galvanized coating on fastness IS: 5358(1969) Specification for Electroplating IS:3203 Specification for hot dip Zinc coating on structural & other allied products IS: 4759(1968) The zinc required for galvanizing shall be quality Zn-98 & shall confirm to IS: 209- 1966 and its latest amendments. All galvanized materials shall withstand test as per IS: 2633 (1972). The weight of zinc coating shall determined as per the method stipulated in IS: 2633(1964) The bidder shall have to submit all the required test reports for the offered item from NABL accredited labs
Laying, clamping and connecting of 75 x 10 mm GI earth strip for main earth grid/earthing network under ground, along structure, cable trays, racks walls, roofs, in trench etc. including excavation and filling of earth, chipping and remaking of concrete surface, supply and fixing of GI clamps, Supply of fixing GI fastners at earth plate & at equipment end wherever required. Supply & applying bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints. Earthing to be carreid out as per IS:3043 It also includes any modification work because of fouling with under ground/above ground piping.
Supply of GI Earth Strip Size:50X6mm Galvanised with hot dip process Galvanisation thickness:610gm per Sqmtr. Avearge dft:86 microns Conforms to IS:2629/4759 The quoted items should be as per IS: 3043 Recommended practice for hot dip galvanized of Iron Earthing Strips IS: 2629(1966) Methods of testing weight, thickness & uniformity of coating on hot dip galvanized articles IS: 2633(1972) Specification for hot dip galvanized coating on fastness IS: 5358(1969) Specification for Electroplating IS:3203 Specification for hot dip Zinc coating on structural & other allied products IS: 4759(1968) The zinc required for galvanizing shall be quality Zn-98 & shall confirm to IS: 209- 1966 and its latest amendments. All galvanized materials shall withstand test as per IS: 2633 (1972). The weight of zinc coating shall determined as per the method stipulated in IS: 2633(1964) The bidder shall have to submit all the required test reports for the offered item from NABL accredited labs.
Laying, clamping and connecting of 50x6mm GI earth strip for main earth grid/earthing network under ground, along structure, cable trays, racks walls, roofs, in trench etc. including excavation and filling of earth, chipping and remaking of concrete surface, supply and fixing of GI clamps, Supply of fixing GI fastners at earth plate & at equipment end wherever required. Supply & applying bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints. Earthing to be carreid out as per IS:3043 It also includes any modification work because of fouling with under ground/above ground piping.
Supply of 8 SWG Wire rope, confirming to IS: 2629/4579
Laying, clamping and connecting of 8 SWG wire rope for main earth grid/earthing network under ground, along structure, cable trays, racks walls, roofs, in trench etc. including excavation and filling of earth, chipping and remaking of concrete surface, supply and fixing of GI clamps, Supply of fixing GI fastners at earth plate & at equipment end wherever required. Supply & applying bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints. Earthing to be carreid out as per IS:3043 It also includes any modification work because of fouling with under ground/above ground piping.
Supply of conical washers,gasket-10mm,gasket-8mm,installation of 10mm gasket,installation of 8 mm gasket and any other spares that may be required during the time of installation at site.Amount will be reimbursed on production of original bill alongwith the material. Vendor not to quote for this item.
Local control station having - a) Stop switch: Mushroom headed, red colored, twist to release type stop pushbutton with 2NO+2NC type contact block b) Enclosure type weatherproof, > IP65/NEMA 4X protection FRP/GRP enclosure as per BS/IEC60079 with 4mm thickness Impact resistant as BS/IEC/EN 62262 IK-10 UV resistant and fire retardant Suitable for harsh chemical (acidic/alkali) environment with extra deep canopy in front to protect mountings 2 cable of 3/4" at bottom with metallic blanking plug Terminal blocks fixed in GI grid plate with earthing Earthing grid connected to 2 external earth terminals with 2 plain, 1 spring washer and 1 nut and tag Earth terminals, switches, etc. with clear distinction mark Front cover fixed with SS screws to fix with body having Flapper with screw lock system to operate pushbutton Long life high temperature resistant neoprene rubber gasket SS mounting lugs with SS mounting screws Operating temperature: -20 Deg C to +70 Deg C, Operating humidity : 95% RH at 50 Deg C c) Contact block for 110 V DC, 6A with screw termination of WG of 1.5 to 2.5 Sq. mm of Cu/Al Insulation resistance is minimum 100 MOhm at 690 V DC Insulation/Impulse voltage conforming to IEC 60947-1, Silver alloy based contact material, Mechanical durability >1000000 cycles Electrical durability as per IEC 60947-5-1, Vibration and shock resistance capacity as per IEC 60068, Electrical Shock protection as class II as per IEC 60536 d) To be used as emergency stop pushbutton for transformer
Installation of emergency stop push button LCS at site as per direction of E-i-C including glanding,termination
Supply of transformer oil having the following specification: Transformer Oil for Power Transformer-IS-335/1993 (4th rev)-he Oil should have Density at 29.5 degC = 0.89 g/cm3 (max), Viscosity at 27 degC = 2 7 cSt (max), Min Break down Volt for unfiltered oil = 30 kV, Specific resistance at 27 degC = 1500 x 10sqr12 Ohm-cm (min), Water content = 50 ppm (max).
Transformer oil filtration using filtration machine till desired BDV value of oil is reached.After successful oil filtration job top up of oil to a level > 1/2 of main conservator tank.Filtration machine will be supplied by the bidder
Supply and laying of following sizes of G.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, union, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials,Sealing of upto 1100V 3/3.5/ 4 core of size Fireproof/Waterproof Compund, as per approved specifications and directions of Engineer-in-Charge.
Supply and laying of following sizes of G.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, union, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials,Sealing of upto 1100V 3/3.5/ 4 core of size Fireproof/Waterproof Compund, as per approved specifications and directions of Engineer-in-Charge.
Supply of double compression weather proof brass type cable glands of appropriate size suitable for 5Cx2.5 sq.mm for control cables for transformer marshalling cabinet,33KV ICOG & 11KV panel
Supply of 3cX2.5 sq.mm copper armoured PVC FRLS cable,voltage grade 1.1kV
Supply of 11KV,XLPE cable Supply of 11kV (UE) Grade, 3C x 300 Sqmm HV Power CableAl conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the Data sheet of cables
Supply of 33KV,XLPE cable Supply of 33kV Grade, 3Cx120 Sqmm HV Power Cable Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the Data sheet of cables
Supply of 1.1 kV Grade, 7C x 2.5 sq mm Control CableCU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed control cable as per the attached data sheet of cables"
"Laying of cables with outer diameter upto 40 mm. LAYING CABLE :Laying, testing and commissioning of following sizes LV, MV & HV Cables and sealed properly of upto /3.5/ 4 of size PVC caps in designated cable route (in built-up readymade trenches; overhead cable trays; pull through pipes; exposed on wall/ beam/ rakes/ trusses tie/ beam/ embedded in floor or buried directly underground; or through G.I.pipe ). Cables shall be PVC/XLPE insulated; PVC Sheathed; FRLS armoured Aluminium/ Copper Cables or similar types as per IS:1554 (PART-I), IS 7098 PART I & IS 1225-latest version.; Unit rates quoted for installation of cables shall be same irrespective of route and method of laying. The item shall include laying, pulling of cables, proper dressing of cables on cable trays, racks, vertical raceways etc. and supply and installation of saddles, spacers and nylon chord for tying as required, stainless steel/aluminium/lead strip identification tags at strategic points/ every 50 meter intervals, aluminium clamps. etc. The straight through Jointings/ tying of upto 1100V 3/3.5/ 4 core of size armour in the cables should be avoided/ minimised. Item includes transportation from store/yard to site at the place of installation, unpacking, including all labour and materials.Empty drums and excess cable to be rerolled and transported back to desigated store/yard. The designated store/yard will be located inside NRL refinery site or NRMT."
"Laying of cables with outer diameter above 40 mm. LAYING CABLE : Laying, testing and commissioning of following sizes LV, MV & HV Cables and sealed properly of upto /3.5/ 4 of size PVC caps in designated cable route (in built-up readymade trenches; overhead cable trays; pull through pipes; exposed on wall/ beam/ rakes/ trusses tie/ beam/ embedded in floor or buried directly underground; or through G.I.pipe ). Cables shall be PVC/XLPE insulated; PVC Sheathed; FRLS armoured Aluminium/ Copper Cables or similar types as per IS:1554 (PART-I), IS 7098 PART I & IS 1225-latest version.; Unit rates quoted for installation of cables shall be same irrespective of route and method of laying. The item shall include laying, pulling of cables, proper dressing of cables on cable trays, racks, vertical raceways etc. and supply and installation of saddles, spacers and nylon chord for tying as required, stainless steel/aluminium/lead strip identification tags at strategic points/ every 50 meter intervals, aluminium clamps. etc. The straight through Jointings/ tying of upto 1100V 3/3.5/ 4 core of size armour in the cables should be avoided/ minimised. Item includes transportation from store/yard to site at the place of installation, unpacking, including all labour and materials.Empty drums and excess cable to be rerolled and transported back to desigated store/yard. The designated store/yard will be located inside NRL refinery site or NRMT."
Supply of 600 mm Width Ladder Type GI Cable Tray Straight Element.600mm width,(100mm side rail, 3 meter long) 3 mm thick, spacing of rungs at 250 mm, Galvanised Steel & ladder type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection), accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
Supply of 300 mm Width Perforated Type GI Cable Tray Straight Element.300mm width,(100mm side rail, 3 meter long) 3 mm thick, Galvanised Steel & perforated type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection), accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
Supply of 600 mm Width Perforated Type GI Cable Tray Straight Element.300mm width,(100mm side rail, 3 meter long) 3 mm thick, Galvanised Steel & perforated type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection), accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
Supply of Tray Cover for 300 mm Width GI Cable Tray Straight Element.300mm width, 1.6 mm thick Galvanised Steel trays covers complete with 2 sets of cover clamp, complete with accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
Installation of 600 mm Width Ladder Type GI Cable Tray Straight Element.600mm width,(100mm side rail, 3 meter long) 3 mm thick, spacing of rungs at 250 mm, Galvanised Steel & ladder type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection), accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
Installation of 300 mm Width Ladder Type GI Cable Tray Straight Element.300mm width,(100mm side rail, 3 meter long) 3 mm thick, spacing of rungs at 250 mm, Galvanised Steel & ladder type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection), accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
Installation of Tray Cover for 600 mm Width GI Cable Tray Straight Element.600mm width, 1.6 mm thick Galvanised Steel trays covers complete with 2 sets of cover clamp, complete with accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
Installation of Tray Cover for 300 mm Width GI Cable Tray Straight Element.300mm width, 1.6 mm thick Galvanised Steel trays covers complete with 2 sets of cover clamp, complete with accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
"Supply of Heat Shrinkable Termination Kit for 33kV (UE) Grade, 3C x 120 Sqmm - outdoor Type.
Termination of Heat Shrinkable Termination Kit for 33kV (E) Grade, 1C x 630 Sqmm - outdoor Type.This includes cutting stripping of cable insulation, supply & fixing compression type lugs and crimping on to the cable, executing termination using termination kit (Heat Shrinkable) restoration of the insulation, clamping, including anti tracking compound, ferrules, clamps, Aluminium tags, tagging and earthing of armour, installation & supply of PVC shrouds and PVC Hoods of required size for terminations. All necessary consumables and GI hardware, supply & installation of PVC shrouds for outdoor terminations"
Supply of Heat Shrinkable Termination Kit for 11kV (UE) Grade, 3C x 300 Sqmm - outdoor Type.
Termination of Heat Shrinkable Termination Kit for 11kV (UE) Grade, 3C x 300 Sqmm - outdoor Type.This includes cutting stripping of cable insulation, supply & fixing compression type lugs and crimping on to the cable, executing termination using termination kit (Heat Shrinkable) restoration of the insulation, clamping, including anti tracking compound, ferrules, clamps, Aluminium tags, tagging and earthing of armour, installation & supply of PVC shrouds and PVC Hoods of required size for terminations. All necessary consumables and GI hardware, supply & installation of PVC shrouds for outdoor terminations"
"Making of HT heat shrinkable cable joints and end terminations for indoor & outdoor as per requirement- including cutting, stripping of insulation etc. upto 400 sqmm excluding supply of jointing kit and accessories including all labour and materials etc complete as required. 3 Core cables 11 kV,1Cx630 sq.mm 33KV cables"
Supply of HV tape 33KV
Shifting of transformer from existing location to new location and installation at new location above civil foundation.Necessary rail supports and supports for installation of the transformer shall be under the scope of the bidder.Crane/hydra/tractor-trailer shall be provided by NRL free of cost. Job shall be executed as per direction of E-i-C
Shifting of transformer NGR from existing location to new location and installation at new location above civil foundation..Crane/hydra/tractor-trailer shall be provided by NRL free of cost.Job shall be executed as per direction of E-i-C
Painting of transformer and NGR shall be under the scope of the bidder.Paint shall be as per IS-5,RAL-7031
Earth Electrodes : Supplying, providing and constructing GI Pipe Earth electrodes as Per IS:3043; GI Pipe Medium Class'B' 65 mm Dia; 3000 mm long complete with Earth Pit and all necessary materials including excavation of Earth Pit, filling with homogeneous layer of Charcoal and salt, Back filling, providing necessary Brick Masonry work, Plastering, MS/CI cover; Test links for connecting the earth Grid and Earth Electrode etc. complete as per Annexure D. This also includes testing of Earth resistance after completion as per Indian Electricity Rules. Minimum depth of burial shall be 3000 mm, homogenous hygroscopic material should not be less than 1 cum. & should cover 300 mm around the electrode up to a height of 2500 mm. Include 100mm dia GI pipe on all four sides for entry of earth strips. The scope of work also includes providing earth pit markers indicating resistance, test date, next due date etc. as per std. earthpit boards on GI plate of size @ 300 x300 mmx 2mm thick with a GI hollow section stand of of 25 mm square & length @ 1m; grouted in PCC 1:4:8 at a depth of @300 mm below the ground level and the top of plate should be @ 700 mm above the ground level.
Supply, fabrication and installation of MS base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including shot blasting, welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., supply of paint and applying one coat of anti-rust primer and two finished coats of approved synthetic enamel paint(as per Table-10 of specification 6-44-0004 suitable for highly corrosive environment) including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid)
Lettering and Stenciling of 32 mm height including supply of approved colour of Paint/Paints , painting of tag number of Electrical equipments as specified in specification & by Engineer -In-Charge.Supply of various types of paints, primers, preparation of surfaces by manual, hand tool cleaning, power tool cleaning and application of primer and finish paints for equipments surfaces/concrete surfaces, identification (Equipment name) lettering, stenciling,colour bands, colour coding etc as specified including rubdown and touch up of shop primer wherever required, providing scaffolding at all elevations, various locations, labour,materials, tools & tackles, consumables, safety, PPE's, supervision, etc. to complete the work in all respect as per the Painting Specifications drawings, and direction & full satisfaction of owner's/engineer in charge for all types of equipment as specified in the Painting specifications:
Testing and commissioning of transformers of the following rating including all labour and materials , as per direction of E-I-C.Transformer Details: 3.15 MVA Transformer, ONAN, with off circuit tap change, 33/11 KV Dyn1,Make: Crompton Greaves
Arranging CEIG / CEA / Statutory approvals for the entire electrical installation of the plant. Job includes arranging visit of officials, inspection. Preparation of drawings if any, liquidation of punch points by Inspectors, arranging Certificate & approvals all complete. The Base drawings as available with Owner shall be provided .(The prescribed fees for approvals & inspection if paid by Contractor shall be reimbursed by Owner against submission of Documentary Evidence)
"Termination including supply of crimping type, heavy duty, long barrel type Copper lugs for 1.1 kV Grade, 14C x 2.5 sq mm Control CableCU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed control cables.This includes cutting stripping of cable insulation, fixing of cable gland, crimping the lug on to the conductor, clamping of the cable cores, supply, fixing & marking with wire number ferrules etc. All necessary consumables and GI hardware, supply & installation of PVC shrouds for outdoor terminations"
Supply and installation of Cable Markers with 14 SWG enamelled steel plate with white lettering on jade green background Sign (200X60-1no “BURIED ELECTRIC CABLE”, 60X60-2nos direction signs) on Angle (65X65X6, 1100 long, painted white, including PCC foundation), (inclusive of providing and fixing supports, including all labour and materials, complete as per Annexure F and directions of EIC)
Supply, of outdoor Street Light Fixtures and Luminares of type Bajaj BRTG 120W, or equivalent with LED luminaires, IP66, complete with all drivers, accessories etc. as per requirement of E-I-C.
Supply of hot dip galvanised tubular GI Street Lighting Poles of requisite standards of length 11 meters as per Annexure A complete,
Installation, connection and commissioning of hot dip galvanised tubular GI Street Lighting Poles of requisite standards of length 11 meters as per Annexure A complete, including supply and installation of marshalling boxes, cable glands, lugs, terminals, riser GI pipes, wire rope earthing, cleats, internal amoured copper cabling from marshalling box to fixture, etc.; Installation, testing and commissioning of light fixtures and luminaires, glanding, termination etc. complete as may be required including necessary excavation, RCC foundation work, backfilling, supply of cement, labour, all materials, removal of excess earth etc;
Supply and laying of 1000 mm wide safety insulating Rubber Mat suitable for 33 kV System Voltage required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable latest Indian or International standards, CEA regulations and as per directions of Engineer-in-charge
Supply and laying of 1000 mm wide safety insulating Rubber Mat suitable for 11 kV System Voltage required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable latest Indian or International standards, CEA regulations and as per directions of Engineer-in-charge
Supply and laying of gravel at transformer yard
Supply and installation of CO2 Fire Extinguishers (5 kg) including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable latest Indian standards, CEA regulations and as per directions of Engineer-in-charge.
Supply and installation of Sand bucket with stand and sand including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable latest Indian standards, CEA regulations and as per directions of Engineer-in-charge.
Supply and installation of Shock hazard charts printing with three (3) language ie. English, Hindi & Assamese complete with aluminium frame and glass including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable latest Indian standards, CEA regulations and as per directions of Engineer-in-charge.
Supply and installation of Enamelled caution boards printing with three (3) language ie. English, Hindi & Assamese including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable latest Indian standards, CEA regulations and as per directions of Engineer-in-charge.
Preparation of fencing around the periphery of the transformer including supply of all materials,labour and as per direction of Engineer-in-Charge
Supply of Silica gel berather with flange for connection
Supply of Weather Proof Cable Gland for 1.1kV Grade C Cable Double compression Nickel plated brass cable gland suitable for conductor, A
LEAN CONCRETE (PCC 1:4:8 M7.5)Providing and laying in position Plain Cement Concrete 1:4:8 (1 Cement: 4 Coarse Sand: 8 Graded Stone Aggregates) with 40 mm and down size graded stone aggregate as leveling course in foundations, under slabson grade etc., including tamping, curing, shuttering etc.complete for all depths and heights.
Providing and laying in position Reinforced Cement Concrete of specified grade( design mix ) with 20 mm and down size graded stone aggregates excluding cost of centering and shuttering and reinforcement including providing pockets/ shear keys during concreting, vibrating, tamping, curing, sampling, testing and rendering if required, to give a smooth and even surface etc. including cost of all material & labor in substructure, for rafts, plinth beams, footings and other similar items not specifically mentioned herein, for all depths, complete as per drawings, specification and as directed by Engineer-in-charge/ owner. For details refer specification for Plain and Reinforced concrete (NR-0ZZZZ-CV-SPE-0002). Materials to be supplied as per approved vendor lists attached with special conditions of contract. Quoted Rate include supply and mixing of approved brand of Bi-Polar Concrete Penetrating Corrossion Inhibiting Admixture (Masterlife CI 220 or Equivalent) as per manufacturer's specification for protection of re-inforcement against corossion.
Grubbing, scrubbing & clearing the areas, removal of roots/boulders,breaking clods, making up the hollow produced by removal of roots/boulders with available earth, clearing the site of all objectionable/unserviceable materials by means of manual or mechanical excavation as per directions of Engineer-in-Charge. The cutting and stripping work shall be done to an average depth of 300 mm and the surface rough-levelled for subsequent works. Including loading, transport, unloading and disposal of the unserviceable material at designated areas within the plant boundary and leveling the same.
Making horizontal bore under the WBM etc. of the roads: making horizontal bore under the WBM of the roads etc., manually or by machinefor laying upto 100mmNB GI/RCC pipes,excavating the side approach to facilitate boring,backfilling the same after completion of works including supply of tools,tackles and equipments etc. personal protective equipments to complete the job as required ,excluding the supply of GI pipes and as per direction Engineer-in-Charge.
Supply and spreading of approved fine river sand in cable trenches including all labour and materials complete as per specifications and direction of Engineer- in-charge.
Supply and laying of approved second class bricks of thickness 3" in cable trenches for cable protection including all labour and materials complete as per specifications and direction of Engineer- in-charge.(Actual area of laid brick surfaces shall be measured)
Excavation and backfilling of trenches for cable and earth strip in all types of soil (except rock), shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth upto a distance of 30 metre including all labour and materials complete as per approved drawings, specifications and direction of Engineer- in-charge.(Excavated trench dimensions shall be measured).
Supply and installation of chequered plate of MS Plate 6mm thick-supply,fabrication and installation for covering floor cut-outs/cable trenches etc., including all labour and materials and as per direction of Engineer-in-Charge
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
NORTH EASTERN ENGINEERS
B.R.Construction
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .