Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC | L1 | Accepted-AOC L1 is accepted | |
| 2 | L2₹47.5 L+₹52,047.60 (1.11%)Rejected-AOC | L2 | Rejected-AOC L1 is accepted | |
| 3 | L3₹47.6 L+₹61,909 (1.32%)Rejected-AOC | L3 | Rejected-AOC L1 is accepted | |
| 4 | L4₹47.6 L+₹69,330.05 (1.48%)Rejected-AOC | L4 | Rejected-AOC L1 is accepted | |
| 5 | L5₹47.7 L+₹76,421.30 (1.63%)Rejected-AOC ASHIRBAD APARTMENT GANDHI S HOUSE RAMKRISHNA ROAD ASHRAMPARA SILIGURI 01 | L5 | Rejected-AOC L1 is accepted |
| Sl No | Description | Qty | Unit | C. M. AGARWAL AND CO L4 | SUNIL PRADHAN L1 | PRASAD PRADHAN AND SON L3 | HEM RAJ GURUNG L2 | R N De L5 | S K ENTERPRISES L7 | GEETA CONSTRUCTION L6 | G K SUTHAR L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling /Taking out Unserviceable LT cables of size 50 sqmm to 120 sqmm from any position i.e ground / walls / poles / culverts etc complete with protection pipe, complete all as specified and as directed. | 620 | Rm | 80 ₹49,600 | 80 ₹49,600 | 85 ₹52,700 | 90 ₹55,800 | 82 ₹50,840 | 79 ₹48,980 Lowest | 79 ₹48,980 Lowest | 88 ₹54,560 |
| 2.00 | Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of size 70 Sqmm 3.5 core as required at site, complete all as specified and as directed. | 270 | Rm | 860 ₹2,32,200 | 855 ₹2,30,850 Lowest | 857 ₹2,31,390 | 860 ₹2,32,200 | 855 ₹2,30,850 Lowest | 860 ₹2,32,200 | 865 ₹2,33,550 | 859 ₹2,31,930 |
| 3.00 | Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of size 50 Sqmm 3.5 core as required at site, complete all as specified and as directed. | 350 | Rm | 650 ₹2,27,500 | 645 ₹2,25,750 Lowest | 647 ₹2,26,450 | 648 ₹2,26,800 | 646 ₹2,26,100 | 647 ₹2,26,450 | 650 ₹2,27,500 | 648 ₹2,26,800 |
| 4.00 | Dismantling / Taking out Unserviceable LT cables of size upto 35 sqmm any core from any position i.e ground / walls / poles / culverts etc complete with protection pipe, complete all as specified and as directed. | 960 | Rm | 70 ₹67,200 Lowest | 70 ₹67,200 Lowest | 72 ₹69,120 | 72 ₹69,120 | 70 ₹67,200 Lowest | 70 ₹67,200 Lowest | 70 ₹67,200 Lowest | 75 ₹72,000 |
| 5.00 | Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of size 35 Sqmm 3.5 core as required at site, complete all as specified and as directed. | 250 | Rm | 525 ₹1,31,250 | 520 ₹1,30,000 Lowest | 530 ₹1,32,500 | 527 ₹1,31,750 | 525 ₹1,31,250 | 522 ₹1,30,500 | 522 ₹1,30,500 | 527 ₹1,31,750 |
| 6.00 | Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of size 25 Sqmm 3.5/4.0 core as required at site, complete all as specified and as directed. | 200 | Rm | 478 ₹95,600 | 475 ₹95,000 Lowest | 480 ₹96,000 | 480 ₹96,000 | 476 ₹95,200 | 477 ₹95,400 | 479 ₹95,800 | 476 ₹95,200 |
| 7.00 | Supply and Laying in replacement u/s cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables of Size of 16 Sqmm 4 core (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in Trench with the help of shadel, complete all as specified and as directed. | 350 | Rm | 365 ₹1,27,750 | 360 ₹1,26,000 Lowest | 368 ₹1,28,800 | 360 ₹1,26,000 Lowest | 370 ₹1,29,500 | 362 ₹1,26,700 | 360 ₹1,26,000 Lowest | 370 ₹1,29,500 |
| 8.00 | Supply and Laying in replacement u/s cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables of Size of 10 Sqmm 2 core (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in Trench with the help of shadel, complete all as specified and as directed. | 160 | Rm | 272 ₹43,520 | 270 ₹43,200 Lowest | 275 ₹44,000 | 275 ₹44,000 | 275 ₹44,000 | 275 ₹44,000 | 280 ₹44,800 | 280 ₹44,800 |
| 9.00 | Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for foundation and getting out including forming bottom surface to required level or slope, complete all as specified and as directed. | 191.75 | Cum | 605 ₹1,16,008.75 | 600 ₹1,15,050 Lowest | 610 ₹1,16,967.5 | 600 ₹1,15,050 Lowest | 600 ₹1,15,050 Lowest | 600 ₹1,15,050 Lowest | 600 ₹1,15,050 Lowest | 650 ₹1,24,637.5 |
| 10.00 | Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed. | 137.4 | Cum | 272 ₹37,372.8 | 270 ₹37,098 Lowest | 275 ₹37,785 | 275 ₹37,785 | 280 ₹38,472 | 270 ₹37,098 Lowest | 275 ₹37,785 | 275 ₹37,785 |
Tender Value
₹46.3 L
EMD Value
₹86,500
Closing Date
10 Jun 2025, 6:00 pmClosed
Garrision Engineer GE 867 EWS
GARRISON ENGINEER 867 EWS C/O 99 APO
REPAIR MAINT OF LT SUPPLY EXTERNAL ELECTRIFICATION AND CONNECTED MISC ITEMS AND REPAIR MAINT OF SECURITY STREET LIGHT FLOOD LIGHT POST TOP LANTERN GATE LIGHT AUTOMATIC TIMER SWITCH POLE PAINTING AND CONNECTED MISC ITEMS OF WORK AT PEDONG ALGARAH A
2025_MES_709085_1
8463/E8
Open Tender
Civil Works
Item Rate
180 days
PEDONG
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 867 EWS
₹86,500
14 Sept 2025
20 May 2025
17 Jun 2025
20 May 2025
10 Jun 2025
3 Jun 2025
Amount
Dismantling /Taking out Unserviceable LT cables of size 50 sqmm to 120 sqmm from any position i.e ground / walls / poles / culverts etc complete with protection pipe, complete all as specified and as directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of size 70 Sqmm 3.5 core as required at site, complete all as specified and as directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of size 50 Sqmm 3.5 core as required at site, complete all as specified and as directed.
Dismantling / Taking out Unserviceable LT cables of size upto 35 sqmm any core from any position i.e ground / walls / poles / culverts etc complete with protection pipe, complete all as specified and as directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of size 35 Sqmm 3.5 core as required at site, complete all as specified and as directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of size 25 Sqmm 3.5/4.0 core as required at site, complete all as specified and as directed.
Supply and Laying in replacement u/s cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables of Size of 16 Sqmm 4 core (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in Trench with the help of shadel, complete all as specified and as directed.
Supply and Laying in replacement u/s cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables of Size of 10 Sqmm 2 core (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in Trench with the help of shadel, complete all as specified and as directed.
Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for foundation and getting out including forming bottom surface to required level or slope, complete all as specified and as directed.
Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed.
Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and as directed.
M&L for sand cushioning to U/G cable in layers in trenches, complete all as specified and as directed. Note :- Only Puned layers shall be measured for payment
Supply and laying reinforced precast concrete cable cover class LV type 1 flaat size 250mmx150mmx40mm laid in trenches for cable protection, complete all as specified and as directed.
M&L for well burnt bricks, sub class 'B' bricks of size 250mmx125mmx75mm, best quality locally available laid flat dry in trenches for cable protection, complete all as specified and as directed.
Dismantling / Taking out Unserviceable GI pipe of any size removing material from site, complete all as specified and as directed.
M&L GI tube light grade for passing through cables under the floor, along the wall or along the pole of 50mm bore dia and fixed to the poles/walls with suitable size of MS clamps and nut and botls/washers etc including taking down old GI tubing, complete all as specified and as directed.
S&F in repair GI Pipes 40mm bore light grade in any position for protection of cable fixed at pole/laid under road , nallah, crossing walls under floors etc, complete all as specified and as directed.
M&L GI tube light grade for passing through cables under the floor, along the wall or along the pole of 25mm bore dia and fixed to the poles/walls with suitable size of MS clamps and nut and botls/washers etc including taking down old GI tubing, complete all as specified and as directed.
Dismantiling/taking out old unserviceable LT insulator any size, any type from poles, complete all as specified and as directed.
S & F for pin type insulator porcelain vitreous white/ brown or green including one galvanised mild steel spindle two GI washer and one GI nut 100mm height, 65mm dia for 1100 Volt grade complete all as specified and as directed.
S & F for Sackle type insulator porcelain vitreous white/ brown or green including one galvanised mild steel straps of size 31 x 5 mm, washers insulator bolt of 14 mm dia and nuts complete of size 100 mm hight and 115mm dia of working pressure 1100 volts grade, complete all as specified and as directed.
S&F in repair cable route marker of size 100 mm x 100 mm x 5mm thick with GI plate with inspection threon bolted / welded to 35 mm x 35mm x6 mm angle iron 60 cm long and fixing the same in ground as required for LT cable, complete all as specified and as directed.
S&F in repairs Busbar Chambers 8 way 100 Amps outdoor type (IP 65/66) pole mounted including provision of fixing on pole by means of suitable size of clamps with nut and bolts OR provision of fixing on 50 x 50 x 6mm thick angle iron frame work upto height of 0.9mtr above ground level including necessary connection, complete all as specified and as directed. Havells cat part No IHBC010004 or equivalent make of SMC/Hencel.
S&F Busbar Chambers 4 way 100 Amps outdoor type (IP 65/66) pole mounted including provision of fixing on pole by means of suitable size of clamps with nut and bolts including necessary connection including taking down of old u/s bus bar, complete all as specified and as directed. Make Havells cat part No IHBC010004 or equivalent make of SMC/Hensel
Trimming of tree branches which touches the LT OH lines and 2.5 Mtr away from centre line of LT OH lines span not exceeding 60 Mtr distance between poles by using neccessory T&P items and depositing the tree branches/leaves at 30 Mtrs away from the site. Note -Any number of tree branches cut in one span will be measured as one lenght of payment, complete all as specified and as directed.
M & L for Plain Cement Concrete (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) in foundation, filling and mass-concrete etc for pole, stay etc, complete all as specified and as directed.
M & L for Plain Cement Concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregae) as in coping including necessary formwork, weathering, slightly rounded or chamfered angles, finishing of exposed surfaces of concrete to even and smooth without using extra cement, complete all as specified and as directed.
Supply and fixing of earth continuity conductor or main earthing lead fixed to wall or batten or recess or chases or burried on ground or drawn in conduit pipe or fixed to poles in repairs or any other indicated situation for the loop earthing etc. as required of size 32 x 6 mm galvanized iron strip, complete all as specified and as directed.
M&L earthing including dismantling old unserviceable complete with galvanized steel earth plate electrode 600mmX600mmX6.3mm buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and connected to and including using 32 x 6 mm galvanized MS strip wire upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES schedule Part-I, and testing on completion including necessary excavation and earth work in any type of soil, PCC(1:3:6) type C1 chamber, pre-cast RCC slab 50mm thick in cement concrete (1:2:4), type B1, reinforced with welded steel wire fabric or XPM, (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe 40 mm dia, light grade 7.5 mtr long for protection of earth lead upto test point etc, complete all as specified and as directed. Note : (a) Length of earthig connection incl GI strip and protection pipe more than 7.5 Mtr will be measured separately. (b) Contractor should conduct necessary test such as Earth continuity, earth resistance test in presence of JE (E/M)/Engr-incharge.
Description all as per item No. 23.00 above but with GI conductor 4 mm dia as earth electrode and 15mm dia protection pipe
Dismantling / Taking down old unsv stay assembly, complete all as specified and as directed.
M & L stay assembly with accessories as shown in Elect plate No- 01 of MES schedule Part-I complete with diameter of rod 16 mm . Note - Loop type insulator , stay clamps , excavation and concrete will be measured and paid separately, complete all as specified and as directed.
Supply & Fixing in replacement loop type insulator vitreous porcelain white, brown, or green of size 65 X 90 mm clearance of hole 16 mm, complete all as specified and as directed.
M&L for painting of steel tubular pole of any size , vertical complete with cross arms with one coat of aluminium paint after cleaning and preparation of surfaces of poles, cross arms, painting 30 cm wide Yellow and black strip on poles up to 1.5 mtr high above coping level and numbering of size 70mmx40mm by using stencil to the pole with black synthetic enemal paint (1st grade ), complete all as specified and as directed.
Restringing of existing LT overhead line including removing the existing binding wire and rebinding with new binding wire after tightning of overhead lines including disconnecting existing jumpher and connections and reconnecting after tightning of conductor incl replacement of all jumpers, complete all as specified and as directed. Note - (a) Any run of conductor in between two span in LT lines shall be measured as one lenght for payment purpose. (b) ACSR conductor will be measured and paid separately.
M&L for Repairing of LT panel by means of replace the hinge and locking arrangement of the existing panel, tightening the cable with bus bar by means of suitable lugs, replacement of suitable indicator with colour, complete all as specified and as directed.
S & F in repairs MCCB 4 pole 160 Amps, with thermal release range 70-100% and magnetic setting adjustable, breaking capacity 36 KA, complete all as specified and as directed.
S & F in replacement of existing type MCCBs of 200 Amps, 415Volt, breaking capacity 25 KA, 4 Pole, complete all as specified and as directed. Make : Legrand/L&T/Schneider
S & F in replacement of existing type MCCBs of 250 Amps, 415Volt, breaking capacity 25 KA, 4 Pole, complete all as specified and as directed. Make : Legrand/L&T/Schneider
Material and labour for spray painting to outdoor/Indoor type double door LT panels/Fedder pillar box incl angle iron stand with synthetic enamel paint after cleaning the surface thouroughly with scrapper including protecting/cleaning of cables, wiring and other non painted parts, complete all as specified and as directed.
Supply and fix cable jointing kit in repairs of existing LT 1.1 KV grade cable disconnecting from site (by means of disconnecting from panel/trench by excavation) for outdoor termination Straight through tubular sleeve version type joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 Sqmm, complete all as specified and as directed.
M & L Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size, including taking out old unserviceable rusted out danger plate, complete all as specified and as directed.
M & L for DK Thermoplastic cable junction boxes in repairs of make Sintex, product code GSJB-3126, IP 65 of size 270x225x135mm of metric knockouts for cable entry, weather proof for indoor/outdoor installation with and including glands/insulators and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 2/4 core and fixed to wall/Steel Poles by means of suitable size of clamps with nut and bolts complete including taking down existing existing junction box, complete all as specified and as directed. NOTE: Make of Junction box shall be Sintex/Hensel or equivalent as approved by GE
Taking down unserviceable fitting of any type or any wattage i.e. 100/90/80/72/60/45/30/25 Watt energy efficient street light fitting, identifying the fault, repair / replacement of old unserviceable accessories with new accessories, reassembling and make the street light fitting functional and refixing in existing location including three core copper PVC insulated conductor of 1 sqmm size (nominal area) of suitable length to connect the lumaniries to overhead conductor / existing lines, complete all as specified and as directed. Note : Spares part/material required for repair to street light fitting shall be measued and paid separtely under relevent items as supply only.
Supply only 1100 volts grade heavy duty cable PVC insulated and FR PVC rounded sheathed, copper conductor (flexible) industrial cable, conforming IS: 694 of size 1.5 sqmm 3 core laid along pole from junction box to light fitting, complete all as specified and as directed.
Supply only in replacement of street light driver of 25 watt to 50 watt, 230V,50Hz suitable for operation over voltage range of 140V to 270V by emoving from existing position, complete all as specified and as directed.
Supply only in replacement of street light driver of 55 watt to 100 watt, 230V,50Hz suitable for operation over voltage range of 140V to 270V by emoving from existing position, complete all as specified and as directed.
M & L in for DK Thermoplastic cable junction boxes IP 65 with of size 300x200x105 of metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 2/4 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut and bolts and incl provn for fixing 01 No. of single pole MCBs 6-32 amps,10KA and MCB TP 6-32 amps, 10 KA, ‘C’ series 01 No inside the box incl taking down old u/s junction box, complete all as specified and as directed. Make : Sintex/Hensal or equivalent approved by GE.
S&F in repairs LED street light fittings, IP-66, 70 watt including bracket made out of 40 mm dia light grade GI pipe not less than 1.2 mtr long bend to shape duly fixed with MS clamps of 3mm thick, nut, bolts etc complete fixed to steel tabular poles including electrical connection complete with 3 core 1.5 Sqmm PVC sheathed stranded copper wire ISI marked from junction box to fitting, complete all as specified and as directed. Make Havells, cat part No "ENDURAOMNIPLUSSL70WLED757SASYTOPC" or equivalent model of Crompton/Bajaj/Philips
S&F in repairs automatic street/security light switch of rating 8 KW in three phase using nature switch for automatic switching of street lights based on lux level on nature light. The sensor (Nature Switch) along with suitable power contactor, MCB and supprot terminals should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade special moulding compound (Polycarbonate) conforming to IP 54 along with each contactor 25-32 Amps , Incoming-Outgoing MCBs (03 Nos each) rating : 32 Amps, circuit wiring min 10 sqmm, complete all as specified and as directed. Model - SWADEEP - 02EC8KW3P. MAKE- 1.Nature-Nature Switch : Kakatiya Energy systems Pvt. Ltd / HEALER / BAJAJ / Havells 2.Contactor : BCH / L& T / Schneider 3.MCB : Hager / Schneider /L&T/C&S 4. Circuit wiring : Finolex / Polycab or equivalent.
Dismantling and removing old unserviceable in repairs earthing and material and labour for earthing complete wih galvanised steel earth plate electrode 60cmx60cmx6.00 mm thick burried directly in ground vertically toa depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level connected to and including galvanized iron earth strip of size 32x6 mm by means of bolts, nuts , chucknut, and washer etc , made of GI and connecting to earth test point all as shown as electrical plate to 5 of SSR Pt -1 2009 an as specified or indicated and testing on completion including earth work and excavation in any type of soil PCC (1:3:6) type C-I earthing chamber, precast RCC slab 50 mm thick in cement concrete (:) type B1 reinforced with welded steel wire fabricated weight not less than 4 Kg/ Sqm . Funnel with GI watering pipe 20 mm bore medium grade wire mesh test point etc, complete all as specified and as directed.
Supply and fixing in repairs post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and as directed. Make : LPTO-40-CDL/M of Crompton or equivalent in Havells/Philips or equivalent
Supply and fixing LED Bollard with robust design and efficient light distribution 10W 230 watt volts AC outdoor type with decorative with IP 65 protection with impact and corrosion resistant, complete all as specified and as directed. Make : LBLSR-10-CDL of Crompton or quivalent in Havells/Philips or equivalent
S&F LED type 24 watt all in one Solar LED street light in aluminium Die cast housing with IP 68 protection lumen output> 3000 lumens with 30 LED chips of 1 watt each system efficiency should not less than 175 lumens /watt CRI -70(+/-%%) CCT -5700 K (+/-5%) UV stabilized polycarbonate cover for better should be used with battery capacity >170wh integrated MPPT charger with driver luminaire should have built in PIR sensor foxture tilt angle should be 0-15 degree adjustable input voltage -12V DC to 14V DC LED burnung hours should be >50000 Hrs @ L70 luminaire should have charging & discharging LED indicator with 110watt poly, solar PV module as per MNRE standard with RFID (25 years performance warranty), complete all as specified and as directed. Note - Light should be with 5 Years warranty Make : Philips/Havells/RS Solar/Crompton
Note : In case of doubling/duplicancy of BOQ items, the lowest quoted rate shall be applicable for payment.
HEM RAJ GURUNG (BID ID -3318281)
PRASAD PRADHAN AND SON (BID ID -3318277)
C. M. AGARWAL AND CO (BID ID -3318116)
R N De (BID ID -3318441)
GEETA CONSTRUCTION (BID ID -3318947)
S K ENTERPRISES (BID ID -3318498)
G K SUTHAR (BID ID -3318282)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .