Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC 227 NEW GANESH VIHAR ADARSH MILL ROAD GHOSIPURA LASHKAR GWALIOR 474012 M P | GWALIOR | MADHYA PRADESH | 474012 | L1 | Accepted-AOC Lowest tender | |
| 2 | L2₹12.8 L+₹1.4 L (12.7%)Rejected-Finance BANSIPURA MORAR GWALIOR 474006 M P | GWALIOR | MADHYA PRADESH | 474006 | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹13.5 L+₹2.2 L (19.4%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹15.0 L+₹3.7 L (32.5%)Rejected-Finance G 124 FLAT NO 4 DILSHAD COLONY DELHI 110095 | SHAHDARA | DELHI | 110095 | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹17.4 L+₹6.1 L (53.6%)Rejected-Finance | L5 | Rejected-Finance Not being lowest tender |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Feb 2024, 6:00 pmClosed
GE (AF) ADM AREA
GE (AF) ADM AREA GWALIOR-474020
MAINTENANCE AND REDEVELOPMENT OF BOREWELL BY AIR COMPRESSOR MACHINE AT VARIOUS PUMP HOUSE AT AF STN GWALIOR
2024_MES_639929_1
8350/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE (AF) ADM AREA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) ADM AREA
₹40,000
Yes
30 Mar 2024
31 Jan 2024
7 Mar 2024
31 Jan 2024
28 Feb 2024
14 Feb 2024
Amount
Re -development and bore well water yield test of existing / old bore well of 200mm bore by air compressor of requiste capacity (air compressor to be used for 8- 10 hrs per bore ) with air pipe line including lifting /lowering existing any capacity of submersible pumps and motor with column pipes of 100mm bore and all related accessories etc complete all as specified and directed . Note : Serviceable column pipes 100mm bore retrieve shall be reused and rusted/unserviceable column pipes shall be replaced by new and same shall be measured and paid under Sch/BOQ item No.6.02
Re -development and bore well water yield test of existing / old bore well of size 150mm bore by air compressor of requisite capacity (air compressor to be used for 8- 10 hrs per bore ) with air pipe line including lifting /lowering existing any capacity of submersible pumps and motor with column pipes of 80mm bore and all related accessories etc ,complete all as specified and directed . Note : Serviceable column pipes 80mm bore retrieve shall be reused and rusted/unserviceable column pipes shall be replaced by new and same shall be measured and paid under Sch/BOQ item No.6.01 .
Supply and fixing of steel wire rope 8 mm dia for guard and tied / binded with submersible motor and pump set complete all as specified and directed. Note: Taking out of old/brocken steel rope shall be included in srl item No. 1.00 and 20.00 here-in-before.
M&L for mild steel ERW casing pipe fo 200mm bore, ISI marked, having wall thickness 7 mm as per IS 4270-1992, heavy grade jointed with electric resistance of high frequency induction welding the same with existing casing pipe and providing two coats of black bituminous paint externally complete all as specified and directed NOTE: Cost for dismantling casing pipe by cutting including excavation around the pipe for taking out unserviceable casing pipe is deemed to be included in quoted rate.
M&L for mild steel ERW casing pipe of 150mm bore, ISI marked, having wall thickness 7 mm as per IS 4270-1992, heavy grade jointed with electric resistance of high frequency induction welding the same with existing casing pipe and providing two coats of black bituminous paint externally complete all as specified and directed NOTE: Cost for dismantling casing pipe by cutting including excavation around the pipe for taking out unserviceable casing pipe is deemed to be included in quoted rate.
Supply/ jointing and testing galvanized iron water tubing medium grade as in column pipe ,ISI marked, including necessary new GI socket, heavy duty, seamless, long threaded ISI marked & fittings / accessories ISI Marked complete all as specified and directed for the following size
80 mm bore
100 mm bore
Material and labour for cast iron/ductile iron specials/fittings such as bend, tee, socket, collar Reducer, Tail Pieces etc. suitable for spigot and socketed/ flanged end pipe of above150mm bore complete all as specified and directed.
Taking out existing damaged/unserviceable pressure water suction gauge -1 to 600 bar duel shape from existing position complete all as specified and directed.
Supply and fixing of pressure water suction gauge -1 to 600 bar as per existing size for 80 mm/100 mm bore complete all as specified and directed.
Carrying out following tests of water sample of 21 Nos bore wells and 01 outside supply from PHED under AF Station Gwalior and submit report duly signed complete all as specified and directed:- (a) Total Hardness PPM (b) Ph Value (c) Total disolved solids PPM (d) Microbial Test (e) Chloride PPM (f) Heavy Metal (Lead as Pb, Mercury as Hg, Copper as Cu, Magnesium as Mg, Arsenic,Iron as Fe,Fluoride, Nitrate,Sulphate,Calcium as Ca,Cadmium as Cd) (g) Bacteriological test,(h) Turbidity,(I) Total alkalinity,(J) Residual chlorine,(k) Total coliform (l) E coil Note;- All tests shall be carried out in NABL accredited lab after written approval of GE
Material and labour for PCC (1:3:6) type C2 using 40mm graded stone aggregate for anchorage blocks for pipe line/PCC Blocks for Monoblock pump set complete to mounted /making good the cut portion of roads/paths/hard standings etc including necessary from work where required , to support the pipe line complete all as specified and as directed by Engineer-in-charge.
Material & Labour for applying Two or more coatsof 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm over new prepared concrete surface complete all as specified and as directed by Engineer-in-charge.
M/s Khan Construction
anand enterprises
Sunil Traders
KRISHNA & KAVYANSH BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .