Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC lowest bid quoted | |
| 2 | L2₹29.2 L+₹3.8 L (14.9%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L2 | Rejected-Finance Highest bid quoted | |
| 3 | L3₹34.8 L+₹9.3 L (36.7%)Rejected-Finance | L3 | Rejected-Finance Highest bid quoted |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
13 Oct 2022, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
REPAIR MAINTENANCE OF EXTERNAL WATER SUPPLY SYSTEM REPLACEMENT OF PIPES OF SUPPLY AND DISTRIBUTION CLEANING OF UG SUMP/OHT AND ALLIED WORK REPAIR MAINTENANCE AND SERVICING OF DG SETS AMF AND MISC REPAIR TO STP AT AF STN GURGAON UNDER AGE EM AF GURGA
2022_MES_552049_1
CA NO GE/GUR-/NIT-36/2022-23
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹74,000
19 Nov 2022
15 Sept 2022
15 Oct 2022
15 Sept 2022
13 Oct 2022
29 Sept 2022
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 m depth and n.exc 1.5 m wide for laying of pipes/cables etc and getting out all as specified and directed by Engineer in Charge.
M & L for Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed by Engineer in Charge.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge
Taking up or down CI Pipes including all fittings such as spigot and socket ends, bends, belows tee etc laid complete in trenches all as specififed of sizes :-
80mm bore
100mm bore
150mm bore,
Taking up or down DI water mains pipes including all fittings with spigot and socket ends and rubber tytan joints including removing out joints complete in trenches all as specified and directed of sizes :-.
100mm bore
Supply, Laying and Testing of cast iron pipes with spigot and socket ends and centrifugally cast class LA, in any length, laid in trenches complete all as specified and directed of following sizes :-
80mm bore
100mm bore
150mm bore
Supply, Laying and Testing of DI water mains pipes including all fittings with spigot and socket ends and rubber tytan joints Class K9 in any length laid in trenches complete all as specified and directed.
100mm bore
Taking up or down GI tubing medium grade and connections including all fittings such as bends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :-
15mm bore
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
100mm bore
S & F in repair of GI tubing medium grade and connections including all fittings such as bends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :-
15mm bore
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
100mm bore
S & F in replacement Gun metal Gate valve with iron wheel head screwed both ends complete all as specified and as directed by the Engineer-in-Charge of sizes :-
40 mm dia
50 mm dia
20 mm dia
25 mm dia
S & F in replacement check valve heavy duty of gun metal both end threaded and leaf spring loaded vertical type including removing unserviceable foot valve from the suction pipe of the pump set complete all as specified and directed by Engr in charge of following sizes :-
100 mm dia
80 mmm dia
50 mm dia
S & F in replacement CI non return valve complete all as specified and directed by Engr in charge of following sizes :- .
150 mm dia
100 mm dia
80 mmm dia
50 mm dia
M & L for Cutting existing CI or steel tubing of any size for alterations or additions and screwing all as specified and directed by Engg-in-charge
Demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. complete all as shown on drawing NO TD/2004/26 Sh 1/1 to 1/3 and as specified and directed for the following sizes:-
900mm x 750mm x 900mm
900mm x 600mm x 1000mm
S & F in replacement Cast Iron sluice valve, class PN- 1.6 with flanged and drilled ends any pattern including necessary jointing and jointing materials complete (with rubber gaskets, bolts and nuts etc) complete all as specified and directed by Engr in charge including taking down the old worn out sluice valve complete all as specified and directed by Engr in charge for the following sizes :-
150 mm dia
100 mm dia
80 mm dia
Supply only high strength Calcium Hypochlorite based granular chlorination chemical having 60% to 70% available chlorine granuler must contain appropriate quantities of disinfectants/corrosion inhibitors to prevent encrustation/scaling in distribution, packed in 40/45 Kg plastic Drum. Make :- DECLIBAC TECHNOLOGIES, PURI CHLOR BY RAYALASEEMA, POTTER & WATTS, BRIOZING or equivalent as approved by GE
Disconnecting, dismantling the defective three phase induction motor 415 Volts 50 Hz of centrifugal pumpset 1440 RPM and re-winding with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material, varnish,bearing, connection plate and all other petty items like Shaft sleeve DE/NDE made of Bronze, casing wear ring DE/NDE made of Stainless steel, Bearings as per sample etc required to make motor functional and re-assembling the motor including installation, commissioning and testing on full load all as specified and directed. Notes :- (a) Transportation charges from installation to contractor's workshop and back after repair are deemed to be included in the rate quoted in the item. (b) Cost of nuts, bolts, washers, connection plate, grease lubrication to bearing bushes etc are deemed to be included in this rate. (c) Old dismantled winding wire will be contractor’s property for which credit shall be affected as per schedule of credit. (d) Complaint shall be lodged by telephonically, so contractor to specify the telephone no who will received the complaint round the clock. After attending the complaint contractor will obtain the signature from rep of User/AGE/GE every day as a token of complaint attended. If complaint is not attended by the contractor with in five hour the penality of Rs 500/per day to be imposed and amount of penality will be deducted from RAR.
For motor of capacity 60 HP
For motor of capacity 40 HP
For motor of capacity 25 HP
For motor of capacity 20 HP
For motor of capacity 10 HP
For motor of capacity 7.5 HP
For motor of capacity 5 HP
For motor of capacity 3 HP
For motor of capacity 2 HP
Disconnecting, dismantling of Centrifugal monoblock pumpset of capacity as following of 1440 RPM and dismantling of defective parts such as Impeller nut , gland , impeller key, gland packing, water deflector, bush bearing sleeve, gaskets, volute stud and nuts , suction and delivery flange and stud and nuts, gland bolts and nuts Gun metal impeller etc and all other petty items like split gland made of Cast Iron, set of gasket made of asbestos, gland packing, coupling of suitable size for motor etc required to make pump functional and re-assembling the pump with motor including installation , commission and testing on full load complete all as specified and directed by Engg-in-charge. Notes:- (i) Transportation charges from installation to contractor work shop and back after repair are deemed to be included in the rate quoted for the above item. (ii) Cost of nuts, bolts, washers,, grease lubrication to bearing bushes etc are deemed included in this rate. (iii) Complaint shall be lodged by telephonically, so contractor to specify the telephone no who will received the complaint round the clock. After attending the complaint contractor will obtain the signature from rep of User/AGE/GE every day as a token of complaint attended. If complaint is not attended by the contractor with in five hour the penality of Rs 500/per day to be imposed and amount of penality will be deducted from RAR.
For motor of capacity 60 HP
For motor of capacity 40 HP
For motor of capacity 25 HP
For motor of capacity 20 HP
For motor of capacity 10 HP
For motor of capacity 7.5 HP
For motor of capacity 5 HP
For motor of capacity 3 HP
For motor of capacity 2 HP
S & F in replacement MCB TP of capacity 40 Amp,3 phase, AC complete all as specified and as directed by the Engineer-in-Charge.
S & F in replacement MCB TP of capacity 63 Amp,3 phase, AC complete all as specified and as directed by the Engineer-in-Charge.
S & F in replacement MCB TP of capacity 100 Amp,3 phase, AC complete all as specified and as directed by the Engineer-in-Charge.
M&L for CI fittings for flanged pipes upto 150 mm bore ,bends ,cross Tee any type any radius and straight connecting pieces complete all as specified and directed by Engr in charge.
Disconnecting/removing the old unserviceable burnt parts from the FASD starters and supply and fix the new items as per exiting the model for AC 415 V,50 HZ 3 phase suitlable for lthe motors all as directed by the Engineer-in-charge:-
Power Contactor MNX-25 with Aux contacts 1 NO + 21NC of range AC1 - 45 A & AC3 - 25 A of Make - L&T Cat No. CS94110
Power Contactor MNX-40 with Aux contacts 1 NO + 1 NC of range AC1 - 55 A & AC3 - 40 A of Make - L&T Cat No. CS94190
Power Contactor MNX-45 with Aux contacts 2 NO + 2 NC of range AC1 - 80 A & AC3 - 45 A of Make - L&T Cat No. ST19000
Power Contactor MNX-50 with Aux contacts 2 NO + 2 NC of range AC1 - 80 A & AC3 - 50 A of Make - L&T Cat No. ST19001
Power Contactor MNX-70 with Aux contacts 2 NO + 2 NC of range AC1 - 70 A & AC3 - 100 A of Make - L&T Cat No. ST19002
Power Contactor MNX-80 with Aux contacts 2 NO + 2 NC of range AC1 - 80 A & AC3 - 100 A of Make - L&T Cat No. ST19003
Bimetal ver load relay MN-5 type directly mounted/operated of range 30-50 Amp of Make L&T Cat No. SS94136OOGO
Bimetal ver load relay MN-5 type directly mounted/operated of range 66-110 Amp of Make L&T Cat No. SS94137OOKO
Single phase preventer suitable for 3 HP to 50 HP pump sets
M&L for Cleaning of underground RCC reserviour(sump) at undermentioned pump house, by draining out stored water completely with mud, pumping out and throwing away manually with buckets and cleaning of inner surface of bottom and walls of sump after removing complete accumulated sludge/mud, dirt etc and scraping all inner surfaces with steel wire brush and finally washing with fresh water two times, disinfecting the reserviour with 2% solution of potassium permanganate, two coat of white wash inside of the sump and two coat of snowcem paint to the out side of the sump including writing date of cleaning with white synthetic enamel paint complete all as specified and directed by Engr in charge for the following sizes :-.
180000 Gallons capacity at Tejas main pump House
100000 Gallons capacity at Tejas main pump House
100000 Gallons capacity Semi Underground sump at PH No 7
50000 Gallons capacity at PH No 2 & PH No 7
33000 Gallons capacity at Gurugram Bagh & Guard Room
M&L for Cleaning of RCC overhead reserviour of undermentioned capacities at 21 Metre staging by draining out stored water completely cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/mud, dirt etc with steel wire brush and finally washing with fresh water two times, disinfecting the reserviour with 2% solution of potassium permanganate and two coat of white wash all around surfaces of inside of the OHT including writing date of cleaning with white synthetic enamel paint and removing sludge, scale mud etc. complete all as specified and directed by Engr in charge for the following sizes :-.
100000 Gallons at PH No 7
50000 Gallons at PH No 2
Material & labour for 'B' Check of DG set 10 KVA to 25 KVA capacity with replacement of oil filter,Diesel filter & related accessories such as set of 'O' ring, set of joint /gasket, Set of Copper washer,Set of Fuel Flexible Pipe,Set of cogged belt, Set of Hoses, Instrument fuse, Battery maintenance, Duster & Cleaning of installation complete all as specified and as directed
All as serial No 26 here in before but of 63 KVA to 125 KVA DG Sets.
All as serial No 26 here in before but of 160 KVA to 200 KVA DG Sets.
All as serial No 26 here in before but of 600 KVA DG Sets.
Engine oil for B 'Check' 15 W 40 as per OEM manufacturer all as specified and directed by Engineer -in-Charge.
Opening / taking out of fuel injection pump of DG set of any type/make and capacity 10 KVA to 25 KVA disconnection of fuel injector line, carrying complete overhauling/ servicing of injector pump, ,calibration of fuel pump as per manufacturer instruction , assembling the same with DG set properly in original postion, checking the allignment , making proper fuel connection and testing for smooth opreation complete all as directed, after replacement of following items: - (Note:-Supply of Spares shall be measured & paid seperatly in respective items)
Supply only Fuel gear pump.
Supply only Shaft fuel pump drive .
Supply only Shaft fuel pump
Supply only Seal 'O' Ring.
Supply only Gasket fuel pump
Supply only Gear techno meter
Supply only Bushing techno meter.
Supply only Cover fuel pump gear
Supply only Housing fuel pump gear
All as serial No-31 here in before but of capacity 63 KVA to 125 KVA .
Supply only Fuel gear pump.
Supply only Shaft fuel pump drive .
Supply only Shaft fuel pump
Supply only Seal 'O' Ring.
Supply only Gasket fuel pump
Supply only Gear techno meter
Supply only Bushing techno meter.
Supply only Cover fuel pump gear
Supply only Housing fuel pump gear
All as serial No 31 here in before but of capacity 160 KVA to 200 KVA .
Supply only Fuel gear pump.
Supply only Shaft fuel pump drive .
Supply only Shaft fuel pump
Supply only Seal 'O' Ring.
Supply only Gasket fuel pump
Supply only Gear techno meter
Supply only Bushing techno meter.
Supply only Cover fuel pump gear
Supply only Housing fuel pump gear
Removal of self starter motor from the DG set of capacity 10 KVA to 25KVA of existing make , strip opening the starter for the following repair/ replacement including assembling and re-fixing at site.
Supply only Armature.
Supply only Solenoied switch
Supply only Bush gear
Supply only 'O' Ring assy.
Supply only Bush set.
Supply only FIELD Coil
Supply only Sealing kit.
Supply only Brush Set
All as serial No-34 here in before but of capacity 63 to 125 KVA .
Supply only Armature.
Supply only Solenoied switch
Supply only Bush gear
Supply only 'O' Ring assy.
Supply only Bush set.
Supply only FIELD Coil
Supply only Sealing kit.
Supply only Brush Set
All as serial No-34 here in before but of capacity 160 KVA to 200 KVA .
Supply only Armature.
Supply only Solenoied switch
Supply only Bush gear
Supply only'O' Ring assy.
Supply only Bush set.
Supply only FIELD Coil
Supply only Sealing kit.
Supply only Brush Set
Supply & fixing in replacement of old unservicable feed pump for fuel injection pump complete assy for capacity 10 KVA to 25 KVA of DG set complete all as speicifed and as directed
Supply & fixing in replacement of old unservicable feed pump for fuel injection pump complete assy for capacity 63 KVA to 200 KVA of DG set complete all as speicifed and as directed
Supply & fixing in replacement, of fuel shutoff valve assy , solenoied valve kit including taking outold valve assy and making all connection, testing for smooth opreation complete of all DG set capacity 100 KVA to 200 KVA complete all as speicifed and as directed
Material & labour for element Air cleaner,inner for DG set 10 KVA to 25 KVA complete all as speicifed and as directed
Material & labour for element Air cleaner,inner for DG set 63 KVA to 125 KVA complete all as speicifed and as directed
Material & labour for element Air cleaner,inner for DG set 160 KVA to 200 KVA complete all as speicifed and as directed
Material & labour for opening / taking out of injector of DG set of any type/make and capacity 10KVA to 25KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the allignment, making proper fuel connection, testing for smooth opreatio complete all as directed.
All as serial item No 43 here in before but of size 100 KVA to 125 KVA .
All as serial item No 43 here in before but of size 160 KVA to 200KVA.
S&F in replacement of old un/sv lifting magnet of existing make suitable for 100 to 200 KVA DG set complete all as speicifed and as directed
Material & labour for top up of coolent in rediator of DG Set of any type / make and capacity, complete all as directed.
Supply and fixing, in replacement, Radiator cap suitable for DG Set of any type / make and capacity, complete all as directed.
Supply and fixing, in replacement of 12V,70 AH Battery Maint Free complete all as speicifed and as directed
Supply and fixing, in replacement of 12V,180 AH Battery Make-Exide Express/Amoron Maint Free complete all as speicifed and as directed
S&F in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set of various capacity , including all connection testing complete all as specified and directed.
Supply and fixing, in replacement of Old unserviceable RPM CABLE complete all as speicifed and as directed
Supply and fixing, in replacement of Old unserviceable water temp meter complete all as speicifed and as directed
Supply and fixing, in replacement of Old unserviceable OIL PRESSURE METER complete all as speicifed and as directed
Supply and fixing, in replacement of Old unserviceable OIL TEMP METER complete all as speicifed and as directed
Supply and fixing, in replacement of Old unserviceable H.C.T. SWITCH complete all as speicifed and as directed
Supply and fixing, in replacement of Old unserviceable LLOP SWITCH complete all as speicifed and as directed
Repair of door by removing and replacement of damage hinges,acoustic material and providing / fixing of glass wool,tissue paper, MS perforated sheet with painting complete all as speicifed and as directed
Supply & fiXing in replacement of earth continuity conductor GI strip 25x4 mm complete all as speicifed and as directed
Supply and fixing, in replacement, of Automatic Voltage Regulator (AVR) suitable for DG Set of up to 10 to 25 KVA capacity, with and including taking out old AVR and making all connection, testing for smooth operation complete all as speicifed and as directed
All as serial item No 60 here in before but DG Set of 100 KVA to 200 KVA capacity.
Supply and fixing, in replacement, of Rotating diods suitable for DG Set of 10 KVA to 25 KVA capacity, with and including taking out old AVR and making all connection, testing for smooth operation complete all as directed.
All as serial item No 62 but for DG Set of 63 KVA to 200 KVA capacity.
Material & labour for carrying out complete overhauling / servicing of DG set panel / AMF panel / control panel, including checking and rewiring faulty electrical circuit using 1.5 sqmm FRLS copper conductor, Relay, fuse, timer, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation, complete all as directed.
M& L for replacement of contractor of AMF panel contractor MNX300,with NO; NC auxiliary contacts make : L&T
M& L for replacement of contractor of AMF panel contractor GMC- 150/4with NO; NC auxiliary contacts
M& L for replacement of contractor of AMF panel contractor TC (LC1 FDP 225 A) AC3: 225 A, with NO; NC auxiliary contacts
M& L for replacement of co; L&Tcontractor of AMF panel contractorTMNX 40 with NO; NC auxiliary contacts, Make: L&T
M & L for Contractor coil suitable for contractor capacity 150A to 325 A all as OEM manufacturer
Material & labour for Supply & fiXing in replacement of push button.
Material & labour for Supply & fiXing in replacement Digital volt meter ,3 phase(0-500) volt of 96mmx96mm sizes complete.
Material & labour for Supply & fiXing in replacement Digital Ammeter existing make & sizes.
Material & labour for Supply & fiXing in replacement MCCB, TPN, 415 volt, 50 Hz, 200Amp, 35KA of existing make
Supply & fiXing in replacement of Electric Control Unit duly programmed , fixed in control panel with and including checking ,rewiring faulty circuit ,suitable for DG set of any type 100 KVA to 200 KVA .
Supply & fixing in replacement of battery charging unit including rectifier unit , voltage regulator,two Nos clamp,,nuts, bolts and suitable length of stranded copper conductor PVC cable 2.5 sq mm 3 run from power point to battery charger and 2 run fro battery charger to battery etc suitable for 12 volt battery charging unit
All as serial No-75 here in before but suitable for 24 volt battery charging unit.
All as serial item No 75here in before but DG set capacity 100 to 200 KVA .
Taking out and replacement of unservicable/blocked residential silencers of existing make suitable for 100 to 200 KVA and cutting welding and fixing of pipe complete allas directed.
Supply and fixing in replacement of water pump complete of existing make suitable for DG set 100 KVA to 200 KVA all as specified and directed.
Labour for attending of any breakdown of standby supply in any location ,whenever required round the clock ,rectify the fault and restore the standby supply within three hour after receipt of complaint of any nature i.e. Engine, alternator,control panel,AMF panel etc . Note -(i) The cost of replaced spare parts will be paid and measured seperatly. (ii) If complaint is not attended by contractor with in three hour the penality of Rs 500 / per hour to be imposed and amount of penality will be deducted from RAR. (iii) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock.
M&L for capacity 10 to 25 KVA complete descaling of cooling system by radiwash with two times circulation of radiwash by means of running of engine & cleaning of fan blades, crankcase breather, radiator and its fins by means of high pressure air or water.
All as serial item No 81 here in before but of capacity 100 KVA to 200 KVA.
Supply & fixing in replacement, V-belt of DG set 10 KVA to 25 KVA of any type/make and capacity, complete all as directed.
All as serial item No 83 here in before but of capacity 100 KVA to 200 KVA.
Supply and fixing, in replacement, battery terminals made of brass, suitable for battery of any type/make and capacity, complete all as directed.
Supply and fixing, in replacement battery lead in red colour PVC insulated, multi stranded copper single core unsheathed cable of size 70 sqmm, 1100 volts grade,1.5 mtr long fitted with positive brass bty terminal one end and copper thimble of 70 sqmm at other end ,complete all as directed.
All as serial item No 86 here-in before but black in colour fitted negitave bty terminal at one end and copper thimble 70 sqmm at other end
Supply & filling distilled water in sealed packing suitable for DC 12 volt battery
M&L for radiator fan guard of existing make ,including taking out u/s fan guard of 10 KVA to 25 KVA DG set
All as serial item No 89 here in before but for 63 KVA to 200 KVA DG sets.
M & L for servicing of air blower with positive displacement type twin lube root blower with Motor of 12.5 HP to 15 HP capacities, including Opening the blower motor blower shaft, shaft Key ways, shaft holes etc and M & L for replacing the gland packing, gland nuts, coupling, replacement of oil seal including oil and rewinding of blower motor with super enameled copper winding wire as per existing size including re-fixing the same to the original position and commissioning testing complete all as specified and as directed .
S & F Fan belt B-45 suitable for Air blower including taking down complete all as specified and directed.
M & L for Periodical Cleaning of equalizing tank /grit chamber/ oil grease chamber/stilling chamber of Sewage Water in the tank and Removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortor 1:3 where required all as required at site and directed by the Engineer-in-Charge at AF Stn Gurgaon for Sewage tank of STP 500 KLD of under mentioned sizes complete all as specified and directed :- (a) Collection tank dia 6m and depth 9m x 4m - (Sump Well/ Equalization tank). (b) Screen/ grid Chamber. (c) Aeration tank - dia-9m and depth 5m. (d) Clarifier - dia 7.4 mtrs and depth 4.5 mtrs. (e) Sludge drying bed of size 10 m x 4.5 m x1.5m. Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the Delhi Canttonment Board/MCD. (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineerin- Charge.
M & L for Cleaning of filter medial tank (ACF & DMF) , pumping out all sludge and foreign material including washing the entire tank and scraping the walls with wire brushes and making good the patches on walls internally or externally where required all as specified and directed by Engr-in-Charge. (Make: MM Aqua/Venayaka Engineers/ Ion Exchange)
Supply and pouring Bio media made of plastic and corrugated shape having surface area 260 sqm/cum in MBBR as directed by Engr-in-charge
Supply only DWPE chemical for sewage treatment plant.
Material and labour for replacement of quartz silica sand 32-64 grade complete all as specified and directed by Engr-in-charge.
Material and labour for replacement of quartz silica sand 16-32 grade complete all as specified and directed by Engr-in-charge
Material and labour for replacement of quartz silica sand 8-16 grade complete all as specified and directed by Engr-in-charge.
Material and labour for replacement of quartz silica sand 4-8 grade complete all as specified and directed by Engr-in-charge.
Material and labour for replacement of activated carbon IV 1000 complete all as specified and directed by Engr-in-charge.
Taking out complete pebbles from the filter and and refilling the same pebbles after washing /cleaning thoroughly complete all as specified and directed by Engr-in-charge.
M & L for Periodical Cleaning of equalizing tank /grit chamber/ oil grease chamber/stilling chamber of sewage Water in the tank and Removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortor 1:3 where required all as required at site and directed by the Engineer-in-Charge at AF Stn Gurgaon for Sewage tank of STP 300 KLD of under mentioned sizes etc complete all as specified and directed :- (a) Equilizer tank/ /grit chamber/ oil grease chamber/stilling chamber of Sewage Water of size - 6.30m x 4.70m x 6m - 01 No. (b) Sludge holding tank of size - 2.6mx2.6mx3m-01 No. (c ) Fab-1 & Fab-2 of size - 2.1m x 2.1m x 5.80m - 02 Nos. (d) Tube Settler Tank - 4.1m x 2.5m x 3.8m - 01 No. (e) Treated water Tank 9.3 m x 3.4 m x 4.1m-01 No. Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the Delhi Canttonment Board/MCD. (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineerin-Charge.
Supply and mixing of Sodium hypochloride having 10% chlorine content etc required at site and all as directed by the Engineerin-Charge.
Supply and mixing of Poly aluminium chloride 100% purity etc required at site and all as directed by the Engineerin- Charge.
M & L for carrying sample testing of sewage water as per relevant IS of STP and submission of detailed test report to the office of the Engr-in-charge and testing in Govt approved laboratory as approved by GE. (a) Carrying out minimum essential testing of sewage water as per relevant IS mandatory for chemical, odour, PH value,TSS, BOD, COD, total nitrogen, sulphate, oil and grease, ammonical Nitrogen (NH3-N) and Bacteriological total colliform organism and other characterstics as per relevant IS of sewage water. (i) Cost of sterilized bottle as required. (ii) cost of sample collection from Site to laboratory including transportation charges are included in the quoted rate.
M & L for Carrying sample for testing of treated water of STP and submission of detailed test report to the office of the Engineer-in-charge. Details are as under:- (a) carry ing out minimum essential testing of treated water as per IS 3025 & IS 1622 mandatory for chemical , colour, odour, PH value, TSS, BOD,COD, Total residual chlorine, total Nitrogen, sulphate, oil and grease, Ammonical nitrogen(NH3-N) and Bacteriological total coliform organism per 100ml (MPN) and Ecoli in 100ml. (b) Treated sewage water shall confirm to the following characterstics:- (i) TSS : < 10 mg/litre. (ii) BOD : < 10 mg/ litre. (iii) COD: < 150 mg/litre. (iv) Ph: 6.5 -8.5. (v) Total coliform: < 100 MPN/100 ml (desired nil). (vi) Resudual CI> 1 mg/litre. Rest of the characterstic of the treated water shall be as per IS 3025 & IS 1622. (i) Cost of sterilized bottle as required. (ii) cost of sample collection from Site to laboratory including transportation charges are included in the quoted rate.
Supply and fix in replacement MCCB 100 A ,3 pole ,25 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the engineer-in-Charge. Make : L&T/Schneider/Siemens
Supply and fixing in replacement of MCCB 250 A, 4 pole, 36 KA with adjustable thermal magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the engineer-in-Charge. Make :- Legrand/Schineder /Siemens/L&T
Supply and fix in replacement MCCB 160 A ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the engineer-in-Charge. Make : L&T/Schneider/Siemens
Disconnecting/removing the old unserviceable burnt parts from the FASD starters and supply and fix the new items as per exiting the model for AC 415 V,50 HZ 3 phase suitlable for lthe motors all as directed by the Engineer-in-charge.
(a) Power Contactor, 3 pole, MNX-12 with front mounting Aux contacts block1 NO + 1NC of range AC1 -30 A & AC3 - 12 A of Make - L&T Cat No. CS94108 and Aux contat block Cat No CS94112^
(b) Power Contactor, 3 pole, MNX-18 with front mounting Aux contacts Block1 NO + 21NC of range AC1 - 30 A & AC3 - 18 A of Make - L&T Cat No. CS94100 and Aux contact block Cat No CS94112^
(c) Power Contactor, 3 pole, MNX-22 with front mounting Aux contacts 1 NO + 21NC of range AC1 - 32 A & AC3 - 22 A of Make - L&T Cat No. CS94980 and Aux contact block Cat No CS94113^
(d) Power Contactor, 3 pole, MNX-25 with frot mounting Aux contacts 1 NO + 21NC of range AC1 - 45 A & AC3 - 25 A of Make - L&T Cat No. CS94110 and Aux contact block Cat No CS94114^
(e) Power Contactor, 3 pole, MNX-32 with Aux contacts 1 NO + 1NC of range AC1 - 55 A & AC3 - 32 A of Make - L&T Cat No. CS94110
(f) Power Contactor, 3 pole, MNX-40 with Aux contacts 1 NO + 1 NC of range AC1 - 55 A & AC3 - 40 A of Make - L&T Cat No. CS94190 and Aux contact block Cat No CS94114^
(g) Power Contactor, 3 pole, MNX-45 with Aux contacts 2 NO + 2 NC of range AC1 - 80 A & AC3 - 45 A of Make - L&T Cat No. CS97074
(h) Power Contactor, 3 pole, MNX-50 with Aux contacts 2 NO + 2 NC of range AC1 - 85 A & AC3 - 50 A of Make - L&T Cat No. CS97076
(j) Power Contactor, 3 pole, MNX-70 with Aux contacts 2 NO + 2 NC of range AC1 - 100 A & AC3 - 70 A of Make - L&T Cat No. CS97076
(k) Power Contactor, 3 pole, MNX-80 with Aux contacts 2 NO + 2 NC of range AC1 - 100 A & AC3 - 80 A of Make - L&T Cat No. CS97077
(l) Power Contactor, 3 pole, ML-2 with Aux contacts 2 NO + 2 NC of range AC1 - 40 A & AC3 - 32 A of Make - L&T Cat No. SS90701
(m) Bimetal over load relay MN-2 type directly mounted/operated of range 9-15 Amp of Make L&T Cat No. SS94142OOVO
(n) Bimetal over load relay MN-2 type directly mounted/operated of range 14-23 Amp of Make L&T Cat No. SS94144OODO
(o) Bimetal over load relay MN-5 type directly mounted/operated of range 30-50 Amp of Make L&T Cat No. SS94136OOGO
(p) Bimetal over load relay MN-5 type directly mounted/operated of range 66-110 Amp of Make L&T Cat No. SS94137OOKO
Lifting and taking out the sewage submersible pump set and motor of capacity 10 to 15 HP including column pipe by dismantling nut bolt washers and rubber packing etc including disconnecting of submersible cable complete from the sewage sump /well and lowering back the pump after repairing /removing the sludge from the pump including making electrical connection with the existing panel /starter and connecting the complete the column pipe assembly with nut bolts, washers/ packing to the existing header without any leakage complete all as directed. Note :- Rate are deemed to be inclusive for jointing of Submersible Cable , reconnecting the delivery pipe line of submersible pump sets to water mains , testing for satisfactory running & continuous flow of water complete.
All as per item No. 112 desribed here in before but of capacity 2 HP to 7.5 HP complete all as specified and as directed .
M&L for electric arc welding at places like flanges/pipe line, joints , strip of clarifier tank, approach ladder to aeration tank etc all as specified and directed by Engineer-in-Charge.
M&L for rewinding of Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire, varnishing and stamping and overhauling etc. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter, Capacity of motor 10 HP to 15 HP complete all as specified and as directed .
All as per Item No 115 but 5 to 7.5 HP Capacity
M&L for repairing and testing of pump centrifugal/mono block/non clogging upto 5 to 12.5 HP of any make and type including welding work, rotor turning and balancing, re-metaling of shaft bush bearing, keys, mechanincal seal, SS shaft impeller and other such accessories etc required to make pump functional and testing on load complete all as specified and as directed .
M&L for rewinding of electric motor upto 5 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed
M&L for rewinding of electric motor 15 to 20 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes, varnishing and stamping and overhauling. making the winding leak proof etc. and other accessories etc required to make motor functional and testing on load complete all as specified and as directed .
Disconnecting and taking down treated sewage transfer pump set up to 15 HP horizintal type and replacement of burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire including bearing bushes, mechanical seal rotor tunring & balancing, shaft SS impeller varnishing and stamping and overhauling etc. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter and re-assembling and fixing the pump set complete in the same location and testing all as specified and as directed .
M/S Anand Enterprises
k k enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .