Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹4.0 L+₹32,540 (8.83%)Admitted-Finance OPPOSITE VIPUL GAS AGENCY HOSPITAL ROAD SOLAN H P | SOLAN | SOLAN | HIMACHAL PRADESH | L2 | Admitted-Finance | |
| 3 | L3₹4.1 L+₹39,060 (10.6%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Thakur Traders L1 | ROYAL ENGINEERING WORKS L2 | OM MECHNICAL WORKS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Providing and fixing of complete fabricated almirah type panel board complete with ampere meter, voltmeter,hourmeter, CT, selector switch, Bus bar including copper strips, klits complete in all respect. | 1 | Each | 65,000 ₹65,000 Lowest | 70,000 ₹70,000 | 75,000 ₹75,000 |
| 2.00 | Providing and fixing of 75 HP stater MEI/C&S/L&T make complete in all respect i/c all leads and lifts. | 2 | Each | 45,000 ₹90,000 Lowest | 50,000 ₹1,00,000 | 55,000 ₹1,10,000 |
| 3.00 | Providing and fixing ICTP main switch 100amp hevells make ,complete in all respect i/c all leads and and lifts. | 2 | Each | 13,500 ₹27,000 Lowest | 14,000 ₹28,000 | 14,000 ₹28,000 |
| 4.00 | Providing and fixing MCCB 125 amp.complete in all respect i/c all leads and and lifts. | 1 | Each | 12,000 ₹12,000 Lowest | 12,500 ₹12,500 | 12,500 ₹12,500 |
| 5.00 | Providing and fixing 25mm2 copper cable. complete in all respect i/c all leads and and lifts. | 78 | P/Mtrs. | 350 ₹27,300 Lowest | 370 ₹28,860 | 370 ₹28,860 |
| 6.00 | Providing and fixing copper thimbles complete in all respect i/c all leads and and lifts. | 46 | Each | 120 ₹5,520 Lowest | 125 ₹5,750 | 120 ₹5,520 Lowest |
| 7.00 | Supply and fixing of 7.5 HP control panel for Mono submersible pump complete with shaft and angle iron, fabricated dully pained and comparising of air break starter mainswitch of suitable Amp. T.P. Volt meter ,ameter, and single phase preventor, i/c entier carriage of material with in all leads and lifts. | 2 | P/Set | 15,000 ₹30,000 Lowest | 20,000 ₹40,000 | 15,000 ₹30,000 Lowest |
| 8.00Providing and fixing double flanged cast iron sluice valve of Leader/Bhel/ Kirloskar/Kilburn/KSB/Fouress/ Pelicon and other reputed make for common header and capable of with standing the normal seat pressure as per PN 1.0 IS: 14846, C.I. body including two Nos. M.S.flanges table.5 duly welded in the pipe with nut and bolts and gasket sheet including all leads and lifts with upto date ammendment with rising main complete in all respect as per the direction of Engineer-in-charge. | ||||||
| 8.01 | 80 mm dia PN-1.0 | 2 | Each | 13,000 ₹26,000 Lowest | 13,500 ₹27,000 | 13,500 ₹27,000 |
| 9.00 | Providing and fixing Cast steel non return valve of Leader/Kilburn/Pelicon make of 50 mm dia capable of with standing normal seat pressure as per IS:5312-1884 P-I with upto date ammendments for Class-ASA-300 as per direction of the Engineer-in-charge complete in all respect i/c all leads and lifts. | 1 | Each | 22,000 ₹22,000 Lowest | 23,000 ₹23,000 | 24,000 ₹24,000 |
Tender Value
₹3.9 L
EMD Value
₹7,850
Closing Date
29 Sept 2025, 5:00 pmClosed
Executive Engineer
Jal Shakti Division No-I Kasumpati Shimla-9(HP)
.
2025_HPIPH_115309_1
Kasumpti/Shimla/LIS Peeran/3.92
Open Tender
Civil Works - Water Works
Item Rate
180 days
Shimla
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
EE Jal Shakti Division No-I Kasumpati Shimla-9
₹7,850
10 Oct 2025
20 Sept 2025
30 Sept 2025
20 Sept 2025
29 Sept 2025
20 Sept 2025
Amount
Providing and fixing of 75 HP stater MEI/C&S/L&T make complete in all respect i/c all leads and lifts.
Providing and fixing ICTP main switch 100amp hevells make ,complete in all respect i/c all leads and and lifts.
Providing and fixing MCCB 125 amp.complete in all respect i/c all leads and and lifts.
Providing and fixing 25mm2 copper cable. complete in all respect i/c all leads and and lifts.
Providing and fixing copper thimbles complete in all respect i/c all leads and and lifts.
Supply and fixing of 7.5 HP control panel for Mono submersible pump complete with shaft and angle iron, fabricated dully pained and comparising of air break starter mainswitch of suitable Amp. T.P. Volt meter ,ameter, and single phase preventor, i/c entier carriage of material with in all leads and lifts.
Providing and fixing double flanged cast iron sluice valve of Leader/Bhel/ Kirloskar/Kilburn/KSB/Fouress/ Pelicon and other reputed make for common header and capable of with standing the normal seat pressure as per PN 1.0 IS: 14846, C.I. body including two Nos. M.S.flanges table.5 duly welded in the pipe with nut and bolts and gasket sheet including all leads and lifts with upto date ammendment with rising main complete in all respect as per the direction of Engineer-in-charge.
80 mm dia PN-1.0
Providing and fixing Cast steel non return valve of Leader/Kilburn/Pelicon make of 50 mm dia capable of with standing normal seat pressure as per IS:5312-1884 P-I with upto date ammendments for Class-ASA-300 as per direction of the Engineer-in-charge complete in all respect i/c all leads and lifts.
Making of common header with welding grinding etc. complete in all respect i/c all leads and and lifts.
Supply and fixing 4mm2 submersible calbe to submersible sets. Including entire carriage of material upto all leads and lifts.
Providing and fixing 35mm2 copper cable. complete in all respect i/c all leads and and lifts.
ROYAL ENGINEERING WORKS (BID ID -562696)
OM MECHNICAL WORKS (BID ID -562040)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .