Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-Finance DIWANBADA MANEGAON POST OFFICE KHAMARIA JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | ₹1.1 Cr | L1 | Accepted-Finance BEING LOWEST BIDDER |
| 2 | L2₹1.2 CrRejected-Finance | ₹1.2 Cr | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹1.3 CrRejected-Finance | ₹1.3 Cr | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | Rejected-Technical MANEGAON CHAMPANAGAR KHAMARIA JABALPUR 482005 MP | JABALPUR | JABALPUR | MP | 482005 | - | - | Rejected-Technical DUE TO NOT HAVING ELIGIBLE CATEGORY AS PER NIT |
| Sl No | Description | Qty | Unit | C L BHATIA L1 | VEENUS ENGINEERS L2 | PARAS BROTHERS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed. | 81 | Cum | 300 ₹24,300 | 300 ₹24,300 | 200 ₹16,200 |
| 2.00 | Returning, filling in excavated soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. | 55 | Cum | 99.99 ₹5,499.45 | 150 ₹8,250 | 50 ₹2,750 |
| 3.00 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point including spreading complete all as specified and directed. | 26 | Cum | 77.77 ₹2,022.02 | 100 ₹2,600 | 50 ₹1,300 |
| 4.00 | Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. | 16 | Cum | 1,688.88 ₹27,022.08 | 1,800 ₹28,800 | 1,200 ₹19,200 |
| 5.00 | Supply and laying un-reinforced precast concrete cable covers, Class HVP type-1 with peak, Size 300 mm x 180 mm x 40 mm, complete all as specified and as directed. | 1,000 | Each | 32 ₹32,000 | 28 ₹28,000 | 30 ₹30,000 |
| 6.00 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes and testing on completion 11000 volts grade(Earthed) XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 95 sqmm, 3 core including taking out the old unserviceable XLPE/ PILCA cable all as directed. (Note : Excavation, earthwork, sand cushioning and cable protection cover will be measured and paid for separately) | 400 | RM | 1,305 ₹5.2 L | 1,295 ₹5.2 L | 1,250 ₹5 L |
| 7.00 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes and testing on completion, 11000 volts grade(Earthed) XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 120 sqmm, 3 core including taking out the old unserviceable XLPE/ PILCA cable complete all as directed. (Note : Excavation, earthwork, sand cushioning and cable protection will be measured and paid for separately) | 300 | RM | 1,414.14 ₹4.2 L | 1,350 ₹4.0 L | 1,400 ₹4.2 L |
| 8.00 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of Size 50 sqmm to 95 sqmm and testing on completion complete all as directed. | 5 | Each | 6,999 ₹34,995 | 9,000 ₹45,000 | 7,500 ₹37,500 |
| 9.00 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of Size 120 sqmm to 185 sqmm and testing on completion complete all as directed. | 5 | Each | 7,111 ₹35,555 | 9,000 ₹45,000 | 7,500 ₹37,500 |
| 10.00 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of Size 50 sqmm to 95 sqmm and testing on completion complete all as directed. | 5 | Each | 7,555 ₹37,775 | 9,200 ₹46,000 | 8,000 ₹40,000 |
Updated dates
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
21 Mar 2026, 6:00 pmClosed
CWE JABALPUR
HQ COMMANDER WORKS ENGINEER, SUPPLY MARG, P B NO. 54, JABALPUR - 482001
CERTAIN REPAIR AND MAINT OF VARIOUS TYPES OF TRANSFORMERS, VCBS AND MAINT OF HT OH LINE AND UG CABLE AND ALLIED WORKS OF ZONE B AND C AND REPAIR/REPLACEMENT OF DG SET INSTALLED OF ZONE B, ZONE C AND MODERNIZED COD AREA AND 506 ABW, AMC CAPSULE LIFT
2025_MES_742433_2
82737/E8
Open Tender
Miscellaneous Works
180 days
JABALPUR
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (EAST) JABALPUR
₹1.8 L
Yes
3 Jun 2026
11 Feb 2026
28 Mar 2026
11 Feb 2026
21 Mar 2026
27 Feb 2026
11 Feb 2026 - 26 Feb 2026
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point including spreading complete all as specified and directed.
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable covers, Class HVP type-1 with peak, Size 300 mm x 180 mm x 40 mm, complete all as specified and as directed.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes and testing on completion 11000 volts grade(Earthed) XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 95 sqmm, 3 core including taking out the old unserviceable XLPE/ PILCA cable all as directed. (Note : Excavation, earthwork, sand cushioning and cable protection cover will be measured and paid for separately)
Supply and laying or fixing or passing in trenches/ on pole/ through pipes and testing on completion, 11000 volts grade(Earthed) XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 120 sqmm, 3 core including taking out the old unserviceable XLPE/ PILCA cable complete all as directed. (Note : Excavation, earthwork, sand cushioning and cable protection will be measured and paid for separately)
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of Size 50 sqmm to 95 sqmm and testing on completion complete all as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of Size 120 sqmm to 185 sqmm and testing on completion complete all as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of Size 50 sqmm to 95 sqmm and testing on completion complete all as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of Size 120 sqmm to 185 sqmm and testing on completion complete all as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of Size 50 sqmm to 95 sqmm and testing on completion complete all as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of Size 120 sqmm to 185 sqmm and testing on completion complete all as directed.
M &L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in filling in surface channels and drains etc complete all as specified and directed.
Supplying and fixing/ laying of 80 mm bore dia GI pipe light grade in trenches/ under roads/ along pole/ wall including all fittings, ISI marked as required for cable protection etc after taking out the old unserviceable pipe complete all as specified and directed.
M&L for boring of holes under road/pavement /hard standing by trenchless technology with neccessary machineries for inserting the GI pipe of SIze upto 80 mm working pressuredia all as directed.
Dismantling of ACSR/AAC conductor of any SIze from LT poles or distribution span etc complete all as specified & directed.
Dismantling of earthing wire of any Size from LT poles or distribution span etc complete all as specified & directed.
Dismantling of MS channel or angle sections, insulators any type & SIzes, brackets, clamps, nut, bolts, washers, of any type/Size from LT poles or distribution span etc complete all as specified & directed.
Supply, fixing and stretching new AACSR/AAC/HT over head conductors of any Size with and including 14 SWG binding wire at site to insulator etc and testing complete all as specified & directed.
Fixing only for binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of AACSR/AAC/HT over head conductors of any SIze with and including 14 SWG binding wire and testing, complete all as specified & directed.
M&L for stretching and then stengthening of over head Galvanised steel wire 3.15 or 4mm dia on existing HT poles including binding & jointing the conductor and testing complete all as specified and directed.
Fixing only for stetching and then stengthening of over head Galvanised steel wire 3.15 or 4mm dia on existing HT poles including binding & jointing the conductor and testing complete all as specified and directed.
M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or SIze as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and dircted.
Supply and fixing of new pin type porcelain, vitreous, white/ brown/ green insulator 150mm high and 150mm dia including one galvanised mils steel spindle, two galvanised iron washers and one galvanised iron nut, suitable for HT 11000 volts after taking out the old unserviceable insulator complete all as specified and directed.
M &L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in filling & mass concrete complete all as specified and directed.
M &L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in coping of pole ect including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed.
M&L and testing on completion lightning arrestor expulosion type complete with all fittings, transmission/ distribution class 65 KA, conforming to IS-3070 (Part-III) 1993 suitable for 11 KV system and mounting on poles including all necessary bolts, nuts and washers and making electric connection including taking out the old unserviceable lightning arrestor complete all as specified and directed.
Routine and periodical cleaning of inside area of 33/11 KV Sub Stations including cutting and removal/ uprouting of unwanted grass/ bushes, small trees near all around sub station and pump houses complex complete including surface dressing and leveling by surface excavation and removal of debris to out Side MD land wherever as required or as directed.
M&L for distilled water for baterry 12 V of any capacity complete all as specified and as directed
S&F in replacement hand hold search light LED 100 W with charging facility complete all as required and directed.
S & F in replacement , PVC insulation tap 3/4 inch width, 7.3 mtr long complete all as specified and as directed.
S&F,in replacement, HT insulation tap 19 mm width, not less than 9.1 mtr long complete all as specified and as directed.
Supply and Fixing in replacement copper fuse wire 200 Amps complete all as specified and as directed .
(A) Disconnecting and taking down of faulty/ defective alumunium/ copper wound TRANSFORMERS of capacity 40 KVA- 1000 KVA, ratio 11/0.433 or 0.415 KV from 2/4 pole structure or Sub Station in Jabalpur cantt and transporting the TRANSFORMERS to workshop for complete overhauling/ repairing & servicing as specified in sub Para (B) here- in - after and transporting back the TRANSFORMERS from workshop to its existing location after complete overhauling/ repairing & servicing including loading & unloading of TRANSFORMERS into the truck with the help of skilled labours and re-installation of TRANSFORMERS at its existing position with the help of chain pullies & skilled labours and making all necessary incoming & outgoing connections and tightening of all connection nuts, bolts, screws etc including following testing before installation and commissioning at Site complete all as specified & directed:- (a) Insulation Resistance Test (b) Ratio Test (c) Double Voltage & Double Frequency Test (d) Transformer Oil Value BDV Test (e) Tap Changing Test of load for all tap poSSRtion
(B) M&L for opening the top cover of defective aluminium/ copper wound TRANSFORMERS of capacity upto 1000KVA, ratio 11/0.433 or 0.415 KV for complete overhauling/ repairing & servicing in folllowing manner:- (a) Taking out the transformer oil from TRANSFORMERS and store the same into seperate barrel container. (b) Taking out the core/ coil assembly of TRANSFORMERS. (c ) Cleaning of TRANSFORMERS inside by using transformer oil. (d) Re-fixing the core/ coils after complete repair/ replacement of core/ coils or re-fixing of re-conditioned core/ coils in TRANSFORMERS including heating up of TRANSFORMERS core assembly to remove complete moisture. (e) Replacement the HV/ LV spindles and bushings etc. complete all as directed by Engineer-in-Charge. (f) Re-fixing of the TRANSFORMERS top cover with and including new rubberized gasket set and nuts, bolts and washers for top cover as per existing make/ as per manufacturer's recommendations duly approved by GE and tightening of all nuts, bolts, screws & gasket etc (g) Checking of all electrical and mechanical components at workshop after making the TRANSFORMERS fully fuctional. (h) All other parts/ items/ components of TRANSFORMERS which are necessary to be replace in the opinion of Engr-in-Charge/ as per manuacturer's recommendations for smooth functioning of TRANSFORMERS, same shall also be replace for smooth functioning and cost of the same shall also be deemed to be included in the unit rate quoted by the contractor.
Re-conditioning of LV leg coils of copper conductor for TRANSFORMERS of capacity upto 1000 KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly in oven, complete all as specified & directed. (Note:- Reconditioning of LV leg coils shall be done if only insulation found damaged and conductor strip is intact i.e. not deformed/ damageed. This item involves all turns of leg coil to be reconditioned, removing complete insulation from conductor strip, cleaning of conductor, wrapping of conductor with fresh DPC insulation and remaking of LV leg coils with reconditioned strip complete all as directed by Engineer-in- Charge.
Re-conditioning of HV leg coils of copper conductor for TRANSFORMERS of capacity upto 1000 KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly in oven, etc complete all as specified & directed. (Note:- Reconditioning of HV leg coils shall be done if only insulation found damaged and conductor strip is intact i.e. not deformed/ damageed. This item involves all turns of leg coil to be reconditioned, removing complete insulation from conductor strip, cleaning of conductor, wrapping of conductor with fresh DPC insulation and remaking of HV leg coils with reconditioned strip complete all as directed by Engineer-in- Charge.
Supply and fixing of new rubberized gasket set and nuts, bolts and washers for top cover, LT terminal box and replacement of LV/ HV spindles & bushings if found unserviceable etc as per existing make/ as per manufacturer's recommendations duly approved by GE suitable for indoor/ outdoor TRANSFORMERS of capacity up to 1000 KVA to stop the leakage after opening the top cover and taking out and re-filling the transformer oil after filtration/ centrifuSSRng of oil as required in various sub stations under GE (E) Jabalpur complete all as specified and directed. Notes:- (i) HV/ LV spindles and bushings shall be measured and paid separately under respective items of BOQ as supply only. (ii) Filtration/ centrifusing of usable transformer oil including filter action by uSSRng automatic centrifuSSRng machine shall be measured and paid separately under respective item of BOQ. (iii) Topping of TRANSFORMERS with new transformer oil if required and same shall be measured and paid seprately under respective item
Supply only LV leg coils of aluminium conductor for TRANSFORMERS of capacity upto 1000 KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly in oven etc, to be fixed, complete all as specified & directed.
Supply only LV leg coils of copper conductor for TRANSFORMERS of capacity upto 1000 KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly in oven etc, to be fixed, complete all as specified & directed.
Supply only HV leg coils of aluminium conductor for TRANSFORMERS of capacity upto 1000 KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly in oven etc, to be fixed, complete all as specified & directed.
Supply only HV leg coils of copper conductor for TRANSFORMERS of capacity upto 1000 KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly in oven etc, to be fixed, complete all as specified & directed.
Supply only HV bushing 11 KV as per existing make/ as per manufacturer's recommendations duly approved by GE for transformers of capacity upto 1000 KVA, to be fixed, complete all as specified & directed.
Supply only LV bushing 0.433/ 0.415 KV as per existing make/ as per manufacturer's recommendations duly approved by GE for transformers of capacity upto 1000 KVA, to be fixed, complete all as specified & directed.
Supply only HV bushing 33/ 11 KV as per existing make/ as per manufacturer's recommendations duly approved by GE for power transformers of capacity 1600 KVA to 5000 KVA , to be fixed , complete all as specified & directed.
Dehydration of transformer oil at Site by using dehydration machine to give 40 KV to 60 KV dielectric strength confirming to IS - 335 of 1993 complete all as specified and directed. Note : The transformer dehydration machine shall be arrange/brought by the contractor at site and no extra amount shall be paid to the contractor.
Material and labour for toping up of the transformer and new with Transformer Oil having dielectric strength of new unfiltered oil not less than 50 KV and after filtration of oil dielectric strength of oil not less than 60 KV.
Supply and filling of Silica gel as per existing make/ as per manufacturer's recommendations duly approved by GE suitable for indoor/ outdoor TRANSFORMERS up to 1000 KVA in various sub stations under GE (E) Jabalpur complete all as specified and directed.
Supply and fixing of Silica gel breather (transparent type) with Silica gel as per existing make/ as per manufacturer's recommendations duly approved by GE suitable for indoor/ outdoor TRANSFORMERS up to 1000 KVA in various sub stations under GE (E) Jabalpur complete all as specified and directed.
Supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug , bolts, nuts & screws complete all as specified, type 410 SP- 55, 11.0 metre long, including painting of pole with one coat of red oxide primer & two coat of aluminum paint & emedded portion shall be painted with two coat of black paint all as psecified in IS including excavation, returning filling, removal of soil, PCC rate included in this item etc all as specified and directed.
S & F in replacement DO fuse element of capacity 50 to100 Amp having 10 Nos of fuses in each pkt for 33 KV grade complete all as specified and directed.
Repair/servicing of existing Gang Operated Devices (GOD) 11 KV and de-carboniz properly of device mechanism fixed with nuts and bolts by using petrolium gel, proper jumpering with P-G clamp and replacement of unserviceable parts of the GOD Note :- Replacement of items like P-G clamp, Insulator, link ( Male - Female) etc and conductor shall be measured and paid seprately as material only.
Supply only in replacement of post insulators with necessary nuts, bolts and accessories.
Supply only in replacement of P - G clamps suitable for farret and weasel conductors.
Supply only in replacement male-female link assembly with brass tinned contact for GOD 11000 volt grade complete.
Supply and fixing of new Air break gang operated switch, triple pole, mechanically operated out door with all fitting/ accessories mounted on and including 11 KV porcelain insulator and steel channel frame GI operating rod 25 mm dia of suitable length with operating mechanism worked from ground level vertically operated as per te requirement including locking arrangement for operating handle complete suitable for current rating upto 200 Amps 11 KV with dropout fuse assembly working pressure including taking down existing old unserviceable Switch air break complete all as specified and directed.
supply and fixing Air break gang operated switch triple pole mechanically operated out door with all fitting/ accessories mounted on and including 11 KV porcelain insulator and steel channel frame GI operating rod 25 mm dia of suitable length with operating mechanism worked from ground level vertically operated as perte requirement including locking arrangement for operating handle complete suitable for current rating upto 400 Amps, 11 KV working pressure including taking down existing old unserviceable Switch air break complete all as specified and directed.
supply and fixing of new Air break gang operated switch triple pole mechanically operated out door with all fitting/ accessories mounted on and including 33 KV porcelain insulator and steel channel frame GI operating rod 25 mm dia of suitable length with operating mechanism worked from ground level horizontally operated as perte requirement including locking arrangement for operating handle complete suitable for current rating upto 400 Amps, 33 KV working pressure including taking down existing old unserviceable Switch air break complete all as specified and directed.
Supply and fixing stay assembly complete with accessories and GI stay rod 20 mm dia 1900 mm long, stay wire 7/4 mm stranded galvanised including mild steel stay plate 300 mm X 500 mm x 6 mm and galvanised thimble, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big SSRze with overall dimensions 90 mm x140 mm clearance of hole 25.5 mm including taking out existing old/unserviceable stay assembly complete all as specified and shown in electrical plate No. 1 of SSR Part –I (2009).
M & L for cleaning/ prepration of complete external surfaces of DISTRIBUTION TRANSFORMER of capacity upto 750 KVA for painting with two coats of synthetic enamel paint of colour/ shed as approved by GE including writing letters or figures (Block, Roman, Italic or Indian) with and including thick enamel paint of approved colour/ shed not exc 5cm in height for SM/ MES No. etc of tranformer complete all as specified and directed.
Repair and overhauling of gang operated drop out / air break switch/isolators 33 KV double break rotating isolated fixed on 33 KV Gantry (33 KV Yard) with replacement of unserviceable parts complete all as directed by Engineer-in-Charge (Note : Labour for replacement of unserviceable parts is deemed to be included in the unit rate quoted against this item. Spare Parts will be measured and paid for separately under relevent items as 'Supply only' )
Supply only tinned copper flexible jumper 400 Amps of 33 KV and testing on completion complete all as directed.
Supply only back connector plate for 33 KV and testing on completion complete all as directed.
Supply only Male- female contact 33 KV for rotary type double break isolator ( GOD Switch ) and testing on completion complete all as directed.
M & L for repair /servicing/calliberation to HT 11KV over current + Earth Fault Relay system and testing of complete all as specified and directed.
S & F in repalcement TNC Switch for 33/11 KV outdoor type VCB all as directed.
S & F in repalcement Local remote switch for 33/11 KV outdoor type VCB switch all as directed.
S & F in repalcement limit switch for 33/11 KV outdoor type VCB all as directed.
S & F in repalcement Trip latch assembly for 33/11 KV outdoor type VCB all as directed.
S & F in repalcement Trip coil, 110 V for 33/11 KV outdoor type VCB all as directed.
S & F in repalcement closing coil, 110 V for 33/11 KV outdoor type VCB all as directed.
S & F in repalcement HRC Fuse, 6 Amp for 33/11 KV outdoor type VCB all as directed.
S & F in repalcement closing buffer for 11 KV indoor type VCB all as directed.
S & F in repalcement trip coil, 110 V for 33/11 KV indoor type VCB all as directed.
S & Fin repalcement closing coil, 110 V for 11 KV indoor type VCB all as directed.
S & F in repalcement Spouts to connect in back Side to CT for 11 KV indoor VCB Panel complete all as specified and directed
M & L for repairing of current transformer of any CT Ratio for 33 KV outdoor type with burnt winding and oil complete all as specified and directed.
M & L repairing of current transformer of any CT Ratio for 11 KV outdoor typewith burnt winding and oil complete all as specified and directed.
M & L for loose filling of 40 mm graded stone aggregates in plinths of out door transformer, sub stns, panel boards yard complete all as directed.
M & L for preparation of old painted surface of HT steel tubular electric pole 11 mtr in the 11/33 kv Sub station 10 to 20 poles structure any hights including channel and clamps by removing all dirt, dust,etc and painting with two coat of synthetic aluminium paint over a coat of red oxide paint including making five strips of 30 cm each upto 1.5 mtr above PCC pedal with two coats of black and white synthetic enamel paint including marking/numbering of pole number with transformer number by means of stencil complete all as directed by Engineer-in-Charge.
Ditto all as per item No 86 but HT 2-Pole structure complete
Ditto all as per item No 86 but HT 4-Pole structure complete
Supply and fixing in replacement of Danger notice plate of 1.6mm thick MS sheet vitreous enamelled white with letters, figures and conventional skull and bones in Signal Red colour and inclusive fixed with MS flat clamps 25x3mm 2 Nos, nuts, bolts for HT 11000 volt of Size 25x20cm complete all as specified and as directed.
M & L for replacement of unserviceable Vacuum Interrupter as per existing make and model for 11 KV VCB all as directed by Engr In Charge .
M & L for replacement of unserviceable Black 11KV Vacuum Circuit breaker Mechanism with spring charging Mechanism as per existing make and model for 11KV VCB all as directed by Engr In Charge .
M & L for earthing complete with galvanised steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe light grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge 8 mesh per linear including 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS TMT bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
Trimming of tree branches 4 metre all around, from the LT/HT pole, for clearing of LT/HT line, by cutting tree branches, any numbers and of any girth, on any number of conductors/earth wire complete all as specified and as directed by Engr- in- Charge. Notes : The above work includes cleaning/ pruning of tree branches falling around the conductors
Cleaning of bushing and terminal of HT potential transformer 11000 volts (outdoor type) by PT liquid/dry type and checking of oil level and proper connection checking and testing with following :- (i) Meggar testing between phase to phase and phase to earth. (ii) Output voltage checking. (iii) Testing report submited by the contractor all as specified and directed
Cleaning of bushing and terminal of HT Current transformer 11000 volts (outdoor type) by CT liquid and dry type and checking of oil level and proper connection checking and testing with following :- (i) Meggar testing between phase to phase and phase to earth. (ii) Output voltage checking. (iii) Testing report submited by the contractor all as specified and directed
Comprehensive maintenance of DG sets , cleaning / servicing including first hand repairs, consisting of normal repairs such as tightening of nut bolts, greasing, checking/replacing of battery terminals, leveling of distilled water, cleaning of main ,battery charging alternator where ever exists with vacuum cleaner including replacements of defective/ worn out spares such as diesel filters, oil filters, rubber hose pipe ,V-belt, fuel pipe and change of oils etc. and cleaning of Radiator etc. for DG Sets 160 KVA, at FOCT (Location : MCMM Jabalpur). Notes for all Items :- (a) The maintenance cost of DG Set for month shall deemed to comprises of cost of labour employed for the purpose, T&P used and other petty items such as cotton waste, Kerosene oil, Grease, nuts, bolts, small spares/consumabnles upto Rs 500/- and labour cost for fixing spares. (b) Major spares of DG Set will be measured and paid for separately under relevent item as "supply only". (c) Minor spares like nuts/bolts, washers, oil seal, gaskets, cotton waste, clamps shall be deemed to be included in the job.
Ditto all as per item no. 98 but for cap 125 KVA DG Set at Location : Navdeep Block in MCMM Jabalpur).
Ditto all as per item no. 98 but for cap 125 KVA DG Set at Location : Offrs Mess in MCMM Jabalpur).
Ditto all as per item no. 98 but for cap 125 KVA DG Set at Location : SM 8 Near in MCMM Jabalpur).
Ditto all as per item no. 98 but for cap 125 KVA DG Set at Location : RawalsonPump Huse ).
Ditto all as per item no. 98 but for cap 125 KVA DG Set at Location : P Hose No 37).
Ditto all as per item no. 98 but for cap 30 KVA DG Set at Location : 4 Tank Pump House in MCMM).
Ditto all as per item no. 98 but for cap 15 KVA DG Set at Location : New Nehra Coy in MCMM).
Ditto all as per item no. 98 but for cap 50 KVA DG Set at Location : Singnal record pump House).
Ditto all as per item no. 98 but for cap 50 KVA DG Set at Location : Singnal record Automation Cell).
Ditto all as per item no. 98 but for cap 50 KVA DG Set at Location : CEA Office Near signal record
Ditto all as per item no. 98 but for cap 50 KVA DG Set at Location : Near MT IN signal record
Ditto all as per item no. 98 but for cap 50 KVA DG Set at Location : ADM Block In signal Recors)
Dismantling radiator assembly from the engine of following capacity of DG sets by disconnecting inlet and outlet connection, overhauling / servicing the radiator, descaling and servicing the radiator internally and externally by using chemicals, including soldering the copper tubes and tank etc for arresting leakage, assembling back including necessary welding and with additional bracket as required. Refixing, reconnecting and testing for proper functioning complete all as specified and directed by Engineer-in-Charge.
DG Set of capacity 15 KVA
DG Set of capacity 50 KVA
DG Set of capacity 63 KVA
DG Set of capacity more than 63 KVA but upto 200 KVA
Dismantling of fuel injection pump assembly complete from the engine of following capacity of DG Sets, servicing, over hauling, replacement of valves, washers etc., assembling, calibration, setting for proper function, reassembling and re-fixing complete all as directed by Engr-in-charge.
DG Set of capacity 30 KVA
DG Set of capacity 50 KVA
DG Set of capacity 63 KVA
DG Set of capacity more than 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA.
Supply only (in replacement) spin on fuel filter (pre and fine filter) element with 'O' ring for generator set of following capacity complete all as specified and directed :-
DG Set of capacity 10 KVA
DG Set of capacity 15 KVA
DG Set of capacity 30 KVA
DG Set of capacity 40 KVA
DG Set of capacity 50 KVA
DG Set of capacity 63 KVA
DG Set of capacity 100 KVA
DG Set of capacity 125 KVA
DG Set of capacity 160 KVA.
DG Set of capacity 200 KVA
DG Set of capacity 750 KVA.
Supply only (in replacement) Dry type Air filter element Inner and Outer unit as required at site with 'O' Ring suitable for following capacity DG Set complete all as specified and directed :-
DG Set of capacity 10 KVA
DG Set of capacity 15 KVA
DG Set of capacity 30 KVA
DG Set of capacity 40 KVA
DG Set of capacity 50 KVA
DG Set of capacity 63 KVA
DG Set of capacity 100 KVA
DG Set of capacity 125 KVA
DG Set of capacity 160 KVA.
DG Set of capacity 200 KVA
DG Set of capacity 750 KVA.
Supply only (in replacement) Lub oil filter element with 'O' Ring suitable for following capacity DG Set complete all as specified and directed :-
DG Set of capacity 10 KVA
DG Set of capacity 15 KVA
DG Set of capacity 30 KVA
DG Set of capacity 40 KVA
DG Set of capacity 50 KVA
DG Set of capacity 63 KVA
DG Set of capacity 100 KVA
DG Set of capacity 125 KVA
DG Set of capacity 160 KVA.
DG Set of capacity 200 KVA
DG Set of capacity 750 KVA.
Supply only (in replacement) By pass filter element with 'O' ring suitable for following capacity DG Set complete all as specified and directed.
DG Set of capacity 15 KVA
DG Set of capacity 30 KVA
DG Set of capacity 40 KVA
DG Set of capacity 50 KVA
DG Set of capacity 63 KVA
DG Set of capacity 100 KVA
DG Set of capacity 125 KVA
DG Set of capacity 160 KVA.
DG Set of capacity 200 KVA
DG Set of capacity 750 KVA.
Supply only V-belt suitable for following capacity DG set including removing old unserviceable fan belt complete all as specified and directed :-
DG Set of capacity 15 KVA
DG Set of capacity 30 KVA
DG Set of capacity 50 KVA
DG Set of capacity 63 KVA
DG Set of capacity more than 63 KVA but upto 200 KVA
Supply and fixing (in repairs) Water Pump Assembly suitable for following capacity DG set including removing old unserviceable water pump Assembly complete all as specified and directed by Engineer-in-Charge :-
DG Set of capacity 15 KVA
DG Set of capacity 30 KVA
DG Set of capacity 50 KVA
DG Set of capacity 63 KVA
DG Set of capacity more than 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA
Supply and replacement Water outlet and inlet hose pipe from radiator to Engine and back from Engine to radiator of following capacity of DG set complete all as specified and directed by Engineer-in-Charge.
DG Set of capacity 15 KVA
DG Set of capacity 30 KVA
DG Set of capacity 50 KVA
DG Set of capacity 63 KVA
DG Set of capacity more than 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA
Supply and replacement Lub oil pipe armoured of suitable length and socket size complete all as specified and directed by Engineer-in-Charge.
DG Set of capacity 15 KVA
DG Set of capacity 30 KVA
DG Set of capacity 50 KVA
DG Set of capacity 63 KVA
DG Set of capacity more than 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA
Supply and replacement Lub oil pressure guage 0 to 10 kg / sq cm complete all as specified and directed by Engineer-in-Charge.
DG Set of capacity 50 KVA
DG Set of capacity 125 KVA
Topping up of coolent in Dg set and also transporting the coolent from AGE E/M store to DG Set site as per requirement complete all as specified and directed by Engineer-in-Charge.
Taking out and topping up of engine oil 15 W 40 grade in the Dg set and also transporting the new oil from AGE E/M fuel store to Dg set site and carrying old oil back to fuel store as per requirement complete all as specified and directed by Engineer-in-Charge.
Supply and replace battery connecting single core copper cable 16sqmm with battery terminal made of brass with nuts/bolts/washer complete all as specified and directed by Engineer-in-Charge.
Supply and top up Battery Distilled water complete all as specified and directed by Engineer-in-Charge.
Disconnecting, dismantling 12V battery charging alternator assembly replacing the unserviceable burnt coil assembly, re-assembling, refixing to engine and testing for satisfactory charging of battery complete all as specified and directed by Engineer-in-Charge
DG Set of capacity 15 KVA
DG Set of capacity 30 KVA
DG Set of capacity 50 KVA
DG Set of capacity 63 KVA
DG Set of capacity more than 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA
Taking out old unserviceable AVR from DG Set and Supply and Fixing AVR (Automatic Voltage Regulator) suitable for DG Set of Make Kirloskar/Cummins/CG, of following capacity having input voltage 2 phase + neutral sensing voltage 415V, output voltage 95 V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4 A, fast acting and frequency 50 Hz complete all as directed by Engr-in-Charge.
DG Set of capacity 10 KVA
DG Set of capacity 15 to 30 KVA
DG Set of capacity 40 KVA
DG Set of capacity 50 KVA
DG Set of capacity 63 KVA
DG Set of capacity 100 KVA
DG Set of capacity 125 KVA
DG Set of capacity 200 KVA
DG Set of capacity 750 KVA
Supply and fixing in replacement of Digital DG Controller suitable for following capacity of DG Set of any capacity complete and connecting with existing electrical circuit complete all as specified and directed by Engineer-in-Charge.
DG Set of capacity upto 63 KVA
DG Set of capacity 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA
Supply and fixing (in repairs) Diode set(Rectifier) of Main alternator of DG Set of following capacity complete all as specified and directed by Engineer-in-Charge.
DG Set of capacity upto 63 KVA
DG Set of capacity 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA
Supply and fixing (in repairs) Contactors 4 pole, 63A, coil volt-240volts, AC 50Hz complete all as specified and directed
Supply and fixing (in repairs) Contactors 4 pole, 100A, coil volt-240volts, AC 50Hz complete all as specified and directed
Supply and fixing (in replacement) CT Coil with CT Ratio 100/5A, 5VA Cl 1.0 accuracy conforming to IS 2705-1992 complete all as specified and directed.
Supply and fixing (in repairs) fuse unit 12 V DC (as per sample) suitable for DG Set control panel complete all as specified and directed.
M&L Minor Repair/cleaning of fuel tank, removing sludge, arresting leak using metal paste/sealant or by welding/soldering, replacement of diesel receiver pipe from lock to tank with clamp set all as required at site for following capacity of DG Set complete all as specified and directed by Engineer-in-Charge.
DG Set of capacity upto 63 KVA
DG Set of capacity 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA
M & L for minor repair to canopy such as to hinges, locking arrangement etc complete all as specified and all directed by Engr-in-charge.
DG Set of capacity upto 63 KVA
DG Set of capacity 63 KVA but upto 200 KVA
Taking down defective self starter 12/24 Volt of DG set of cap from 50 KVA to 160 KVA DG set installed at various installations and servicing/overhauling including replacing of worn out parts like solenoid, bearing, carbon brush, rewinding the starter motor winding, etc. and refitting the same after making serviceable for smooth functioning in all respect all as directed by Eng-in-Charge. Note:-Spares required and rewinding will be measured and paid separately under relevant item of this Schedule here after.
Rewinding the burnt field coil.
Rewinding the burnt armature coil with commutator.
Supply and fixing of bush/ bearing.
Supply and fixing of worm out carbon brush with burst holder.
Supply and fixing of clutch.
Supply and fixing of solenoid switch.
Supply and fixing of Bentex drive.
M & L for electrical pannel rubber/ insullating rectangular shape mat confirming as per IS 15652 of 6mm thickness, 914 mm X 914 mm X10 mm size.Protection level up to 11KV. High electrical insulation resistance 10,00,000 mcga ohm, 100% shock proof under leakage current 10 mA with Fire Retardant and High dielectric strength of 45Kv for 1 minute &.Washable – Easy to clean etc all as per specified and directed by Engr-in-Charge.Make : Caterpillar, Cummins, MTU, Perkins, Mitsubishi, Briggs & Stratton, Generac, Kohler, Kirloskar, and Mahindra Powerol etc
Supply and fixing (in replacement) Water separator suitable for DG sets of following capacity complete all as specified and directed by Engineer-in-Charge.
DG Set of capacity upto 63 KVA
DG Set of capacity 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA
Supply and fixing in replacement stop solenoid 12V, 10 amps single coil 75mm dia, for following capacity of DG set complete all as specified and directed.
DG Set of capacity upto 63 KVA
DG Set of capacity 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA
Supply and fixing in replacement 4-20mA lube oil pressure sensor suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed.
DG Set of capacity upto 63 KVA
DG Set of capacity 63 KVA but upto 200 KVA
Supply and fixing in replacement Fuel level sensor suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed.
DG Set of capacity upto 63 KVA
DG Set of capacity 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA
Supply and fixing in replacement Thermostat element suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed.
DG Set of capacity upto 63 KVA
DG Set of capacity 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA
Supply and fixing in replacement of injector nozzle suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed.
DG Set of capacity upto 63 KVA
DG Set of capacity 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA
Supply and fixing in replacement of Governing card suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed.
DG Set of capacity 10 KVA
DG Set of capacity 15 KVA
DG Set of capacity 40 KVA
DG Set of capacity 50 KVA
DG Set of capacity 63 KVA
DG Set of capacity 100 KVA
DG Set of capacity 125 KVA
DG Set of capacity 160 KVA
DG Set of capacity 200 KVA
DG Set of capacity 750 KVA
Supply and fixing in replacement of start/stop Relay card 12/24 DC suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed.
DG Set of capacity upto 63 KVA
DG Set of capacity 63 KVA but upto 200 KVA
Supply and fixing in replacement of generator Actuator 12/24 DC suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed.
DG Set of capacity upto 63 KVA
DG Set of capacity 63 KVA but upto 200 KVA
DG Set of capacity 750 KVA
Supply and fixing in replacement of generator engine piston suitable for 50 KVA DG Set, as per existing make/size, complete all as specified and directed.
Supply and fixing in replacement of generator engine piston ring set suitable for 125 KVA DG Set, as per existing make/size, complete all as specified and directed.
Supply and fixing in replacement of generator engine intake/exhaust valve suitable for 50 to125 KVA DG Set, as per existing make/size, complete all as specified and directed.
M & L for checking of AMF panels including replacement of unserviceable parts such as Relays, Timers, Power contactors, Auxilary contactors, defective copper wiring, MCCBs etc. for 15 - 200 KVA DG Set, complete all as specified and directed by Engineer-in-Charge. Note: - Spare parts shall be measured and paid for separately as Supply only
Supply only Auxiliary contactor 240 V 3 No & 1 NC complete all as specified and directed.
Supply only ON and OFF delay timer 240 V AC complete all as specified and directed.
Supply only Earth fault relay complete all as specified and directed.
Supply only Over load relay complete all as specified and directed.
Supply only Under voltage relay complete all as specified and directed.
Supply only DC Power Contactor for auto starting 12V complete all as specified and directed.
Supply only Power Contactor MCX 11, 4 Pole complete all as specified and directed.
Supply only Power Contactor MCX 22, 4 Pole complete all as specified and directed.
Supply only Power Contactor MCX 33, 4 Pole complete all as specified and directed.
Supply and fix in replacement of Power Contactor MNX 70 , 3P , 415 V including necessary wiring complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of Power Contactor MNX 110 , 3P , 415 V including necessary wiring complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement On Load Change over switch capacity 400 amps, 415 Volts,4 pole complete with sheet metal enclosure fixed on wall and making proper connections of cables complete all as specified and directed.
Supply and fix in replacement On Load Change over switch capacity 200 amps, 415 Volts,4 pole complete with sheet metal enclosure fixed on wall and making proper connections of cables complete all as specified and directed.
Supply and fix in replacement On Load Change over switch capacity 125 amps, 415 Volts,4 pole complete with sheet metal enclosure fixed on wall and making proper connections of cables complete all as specified and directed.
Supply and fix in replacement On Load Change over switch capacity 100 amps, 415 Volts,4 pole complete with sheet metal enclosure fixed on wall and making proper connections of cables complete all as specified and directed.
Supply and fix in replacement On Load Change over switch capacity 63 amps, 415 Volts,4 pole complete with sheet metal enclosure fixed on wall and making proper connections of cables complete all as specified and directed.
All as per item No. 310 herein above but of capacity 15 KVA
All as per item No. 310 herein above but of capacity 30 KVA
All as per item No. 310 herein above but of capacity 40 KVA
All as per item No. 310 herein above but of capacity 50 KVA
All as per item No. 310 herein above but of capacity 63 KVA
All as per item No. 310 herein above but of capacity 100 KVA
All as per item No. 310 herein above but of capacity 125 KVA
All as per item No. 310 herein above but of capacity 160 KVA
All as per item No. 310 herein above but of capacity 200 KVA
Supply battery leads set, PVC insulated multi-stranded, copper conductor 70 sqmm multi-stranded of 1.25 m long each duly fixed with brass clamps, copper lugs suitable for 100 to 500 KVA DG sets
Taking down the defective flexible coupling at exhaust manifold and fix new flexible coupling stainless steel as per sample Complete .
Over hauling of DG set (50 kVA) engine and replacement of following unserviceable parts : (parts replaced shall be measured and paid seperately).
Supply and fixing in replacement Head gasket set for engine complete all as specified and directed
Supply and fixing in replacement Piston rings for engine complete all as specified and directed
Supply and fixing in replacement Piston for engine complete all as specified and directed
Supply and fixing in replacement Cylinder liner for engine complete all as specified and directed
Supply and fixing in replacement Valve seal for engine complete all as specified and directed
Supply and fixing in replacement Valve guide for engine complete all as specified and directed
Supply and fixing in replacement O ring set for engine complete all as specified and directed
Supply and fixing in replacement Valve - inlet for engine complete all as specified and directed
Supply and fixing in replacement Valve -exhaust for engine complete all as specified and directed
Supply and fixing in replacement Oil seal front side for engine complete all as specified and directed
Supply and fixing in replacement Oil seal rear side for engine complete all as specified and directed
(a) DG Set of capacity 10 KVA.
(b) DG Set of capacity 15 KVA.
(c) DG Set of capacity 40 KVA.
(e) DG Set of capacity 63 KVA.
(f) DG Set of capacity 100 KVA.
(g) DG Set of capacity 125 KVA.
(h) DG Set of capacity 200 KVA.
(j) DG Set of capacity 750 KVA.
Supply and replace battery connecting single core copper cable 16sqmm with battery terminal made of brass with nuts/bolts/washer complete all as specified and directed by Engineer-in-Charge.Make : Caterpillar, Cummins, MTU, Perkins, Mitsubishi, Briggs & Stratton, Generac, Kohler, Kirloskar, and Mahindra Powerol etc
Supply and fixing SMPS battery charger 12V DC including all fixing accessories and re-wiring with suitable size copper conductor FRLS grade PVC insulated two core cable drawn through PVC conduit not less than 20mm dia as required at site and complete all as specified and directed by Engineer-in-Charge.Make : Caterpillar, Cummins, MTU, Perkins, Mitsubishi, Briggs & Stratton, Generac, Kohler, Kirloskar, and Mahindra Powerol etc
Supply and fixing in replacement of Thermal Over Load Relay(Auto/Manual Reset)-HGST Seris Relay range 15A-22A all as specified and directed .Make : Caterpillar, Cummins, MTU, Perkins, Mitsubishi, Briggs & Stratton, Generac, Kohler, Kirloskar, and Mahindra Powerol etc
Supply and fixing in replacement of Thermal Over Load Relay(Auto/Manual Reset)-HGST Seris Relay range 45A-65A all as specified and directed .Make : Caterpillar, Cummins, MTU, Perkins, Mitsubishi, Briggs & Stratton, Generac, Kohler, Kirloskar, and Mahindra Powerol etc
Dismantling, removing the self starter, motor from the engine of following capacity of DG sets, opening the self starter body and overhauling/servicing, replacement of carbon brushes with holders, contact plates, jumping leads and seals, re-varnishing the field coil, armature, re-assembling, testing for smooth functioning and re-fixing with the engine and connecting complete all as specified and directed by Engineer-in-Charge.
(a) DG Set of capacity 10 KVA.
(b) DG Set of capacity 15 KVA.
(c) DG Set of capacity 40 KVA.
(e) DG Set of capacity 63 KVA.
(f) DG Set of capacity 100 KVA.
(g) DG Set of capacity 125 KVA.
(h) DG Set of capacity 200 KVA.
(j) DG Set of capacity 750 KVA.
Supply and fixing in replacement of generator Engine harness for 63 KVA capacity of DG Set, as per existing make/size, complete all as specified and directed.
Supply and fixing in replacement of generator Transducer for 63 KVA capacity of DG Set, as per existing make/size, complete all as specified and directed.
Supply and fixing in replacement of generator coolent temp sensor for 63 KVA capacity of DG Set, as per existing make/size, complete all as specified and directed.
Material and labour for cleaning of Crankcase Breather DG set Capacity above 63 KVA but upto 200 KVA DG Set all as directed and as specified.Make : Caterpillar, Cummins, MTU, Perkins, Mitsubishi, Briggs & Stratton, Generac, Kohler, Kirloskar, and Mahindra Powerol etc
M & L for Electrolyte for battery in sealed Pack . Make : Premium blue/ castrol of 20 ltr in sealed drum.
M & L for electrical pannel rubber/ insullating rectangular shape mat confirming as per IS 15652 of 6mm thickness, 914 mm X 914 mm X10 mm size.Protection level up to 11KV. High electrical insulation resistance 10,00,000 mcga ohm, 100% shock proof under leakage current 10 mA with Fire Retardant and High dielectric strength of 45Kv for 1 minute &.Washable – Easy to clean etc all as per specified and directed by Engr-in-Charge.
Comprehensive maintenance of electrically operated passenger lifts installed at Modernised COD, lift in reliable safe and efficient operating condition through MoU with OEM (Make of Lift - ECE Elevator India) by regularly examining, lubricting and adjusting the equipments and carry out planned maintenance (Monthly, Quaterly, Halfyearly and yearly) in systematic and controlled manner suitable for serving Ground+ Second floors i.e. total Three landings with electric power operated doors installed complete all as specified and directed for the following lifts:- Modernised COD :- HQ Building Capacity of 08 Passanger lifts - 01 Nos (Total Qty = 01 Nos X 09 months= 09 per month)
(vi) The contract included for repair, replacement of machines, motors, generators, ropes, inverter/ ARD system, controller parts, PCBs, belts, rollers, gears, bearings, solenoids, coils, chock break shoes, liners, contactors, relays, push bottons, coils, door operator VVF drive, VVVF main drive, car door, safety device limit switches, emergency alaram system with hooter,governor, hoistway door locks,magnetic switches,magnets,door motor,door drive,encoder,car door safety device, Infrared screen, governors, interlock on hoistway doors, gear oil,travelling cable, indicators, LED display boards and minor mechanical spare parts. The cost of above materials are deemed to be included in the rates quoted by the contractor. (vii) Contractor will prominently display his contact/ mobile number and OEM contact number inside and outside the lift on each lift for call in emergency. (viii) All existing earthing of the lifts shall be maintained and made fully functional by the contractor to the entire satisfaction of the Engr-in-Charge. (ix) The OEM will also detail one technician staff to inspect the lift every week regarding functioning of lifts or any other issues arising in the lift. The problem noticed if any to be informed immediately to JE E/M / Engr-in-Charge. OEM Technician should alaways carry service tools during site visit. (x) Contractor or his rep shall come to the site of breakdown within two hours of notification of breakdown. In case the contractor or his rep shall not come to the site of attending breakdown within two hours, a penalty of Rs 600 per fault per day shall be imposed over contractor and shall be deduct from his dues.
Supply and fixing of 300mm sweep car cabin fan in lift with necessary accessories such as fins/ grills, nuts, bolts and wires, etc.including taking down old unserviceable fan complete all as specified and directed.
M&L for buffing for stainless steel surface inside of lift car cabin complete with using buffing machine and compound for buffing upto remove the dull outlook and rusted spots on steel surface complete all as specified and directed.
M&L for buffing for stainless steel surface inside of lift car cabin complete with using buffing machine and compound for buffing upto remove the dull outlook and rusted spots on steel surface complete all as specified and directed.
Supply and fixing only motors. Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only 10-20mm ropes,Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only inverter/ ARD system, Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only PCBs, Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only belts, Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only rollers, gears, Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only bearings, Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only solenoids switch, Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only coils,Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only chock break shoes, Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only liners, Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only contactors, Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only relays,Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only push bottons,Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only door operator VVF drive, Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only VVVF main drive,Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only safety device limit switches, Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only emergency alarm system with hooter,governor, Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only hoistway door locks,Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only gear oil,Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only governors, Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only flate travelling cable 6 core,Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Supply and fixing only LED display boards.Make : Lift Tech Engineers, Meta Tech Industries, Trade india , Sharp Industries, Ovion Industries etc
Schedule of credit amount of Rs 602672.55 to be deducted during AOC
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.93 MB
TENDER82737.pdf
Tender Documents • 2.28 MB
BOQ_842484.xls
BOQ • 0.66 MB
Download all tender documents and submit your bid