Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹50.0 L+₹2.3 L (4.77%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | Rejected-Technical NO 5 3 JJ KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | TAMIL NADU | 600014 | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CATEGORY | |
| 4 | Rejected-Technical NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CATEGORY | |
| 5 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CATEGORY |
| Sl No | Description | Qty | Unit | RAHUL ENTERPRISES L1 | B5BUILDING SOLUTIONS L2 |
|---|---|---|---|---|---|
| 1.00 | Material and labour for maintenance, servicing and repair of Vacuum Circuit Breakers/Oil circuit breaker HT 11KV 400 Amps/800Amps 50 cycles, breaking capacity 13.5 KA of any make, by opening and checking the internal moving, fixed parts, contacts / wiring, cleaning, painting in existing colour, marking both side as per existing, decarbonising, tightening loosened parts, operational checking of closing / tripping system, lubricating greasing all moving parts, replacing worn out part, copper studs, bolts, nuts, washers, Checking control wiring, oil, busbar, fixed contacts or moving contacts, HT Bushes, Gaskets including unserviceable coil, replacing of defective minor items such as indicators lamps, push buttons, selector switch etc as and when required complete all as specified and as directed. | 26 | EACH JOB | 5,500 ₹1,43,000 | 5,000 ₹1,30,000 Lowest |
| 1.01NOTE :- The item spare parts, oil to be replaced shall be measured and paid separately, However minor items such as indicator, push button, selector switch, gasket, wiring cable shall be deemed to be included in the unit rate with providing the Testing Certificate. | |||||
| 2.00 | Material and labour for maintenance, servicing & Oil Leakage arresting of 66/11 kV, 5/8 MVA Power Transformer, providing necessary gaskets, Oil Seals, cleaning, dusting, decarbonising, tightening loosened parts, including replacing worn out part copper studs, bolts nuts and washers replacing oil Seals, HT bush, gasket including unserviceable coil, including cleaning the transformers externally thoroughly with lint free cloth, tightening the HT / LT terminal nuts, opening the top cover and replacing the perished gasket of top cover, replacing sight glass, replacing of defective minor items such as and when required complete all as specified and as directed. | 4 | EACH JOB | 15,250 ₹61,000 | 15,000 ₹60,000 Lowest |
| 2.01NOTE :- The item spare parts oil to be replaced shall be measured and paid separately shall be deemed to be included in the unit rate, including decaning of old oil. | |||||
| 3.00 | Material and labour in replacement of old unserviceable breather of power transformer 66 KV / 11 KV of capacity 5000/8000 KVA (capacity 5 Kg) fresh silica gel complete all as specified and as directed. | 4 | EACH | 4,500 ₹18,000 | 3,000 ₹12,000 Lowest |
| 4.00 | Calibration of relays through secondary injection method, testing complete outdoor 66 KV Grid for complete operational working of outdoor 66 KV CT, PT, differential protection SF-6 breaker, testing 16 point solid alarm annunciator, hooter, Ammeter, Voltmeter, PF Meter, Frequency Meter, KVAR Meter, Energy Meter, Semaphore Indicators, Breaker Control Switch, Numerical Transformer Differential Relay, O/C, E/F Relay, Auxiliary Relay, High Speed tripping relay, selector switches, indicator lamps, trip circuit supervision relay, DC supply supervision relay by connecting existing control / relay cables and replacement of unserviceable control cables, transformer control SF6 breaker panel and control relay panel etc submitting reports complete all as specified and as directed. | 4 | EACH JOB | 9,500 ₹38,000 Lowest | 12,500 ₹50,000 |
| 5.00 | Material and labour for Calibration of Relays through secondary injection method and testing complete relays like IDMT relays instantaneous earth fault relays on all HT OCB panel/VCB panel control SF6 breaker panel and control relay panel at MRS-I & II and every month submitting reports to Engineer-in-Charge.
NOTE :
(i) Monthly checking and calibration of all relays fixed in VCB, OCB, SF6 breaker for smooth functioning included in the scope of work.
(ii) During monthly checking all tripping/setting to be ensured for proper functioning of relay / breaker. | 11 | PER MONTH | 11,000 ₹1,21,000 | 3,750 ₹41,250 Lowest |
| 6.00 | Servicing of existing fire extinguisher & refilling of dry type fire extinguisher ever safe ABC stored pressure type with pressure 24 bar( 27 degree centigrade) and working pressure 12 bar at ( 27 degree centigrade) with capacity 0f 2 kgs to 50 kgs capacity cylinders complete all as specified and as directed with providing the testing certificate. | 100 | KILO GRAM | 250 ₹25,000 Lowest | 290 ₹29,000 |
| 7.00 | Supply and Installation of 75kg ABC Higher Capacity Trolley Mounted Dry Chemical Powder Type Fire Extinguisher (With CO2 & Powder) complete all as specified and as directed. | 1 | EACH | 51,000 ₹51,000 Lowest | 55,000 ₹55,000 |
| 8.00 | Material and labour for filtration of transformer oil of transformer including OLTC through high vacuum type filtration plant to extract moisture, carbon deposits, to achieve and withstand 80 KV die electric strength for 1 min with an air gap of 2.5 mm including necessary testing before, after filtration, submission of test result, complete all as specified and as directed for 5 MVA - 02 nos and 8 MVA - 01 no and 11/0.433 KV transformer of 200 KVA and 100KVA with providing the Testing Certificate. | 28,000 | LITRE | 9 ₹2,52,000 Lowest | 11 ₹3,08,000 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
18 Oct 2025, 6:00 pmClosed
LT COL CHANDRAKANT JOSHI
DRDO Complex, CV Raman Nagar PO, Bangalore 560 093
REPAIRS REPLACEMENT SERVICING TO HT SWITCH GEARS 66 KV 11 KV SF6 VCB OCB AND OVERHAULING OF 66 11 KV TRANSFORMERS AT 66 KV MRS I AND II UNDER GE I R AND D EAST BANGALORE
2025_MES_730408_1
8653/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D EAST BANGALORE
CLASS D CATEGORY b(iii)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D EAST BANGALORE
₹96,000
Yes
3 Dec 2025
17 Sept 2025
25 Oct 2025
17 Sept 2025
18 Oct 2025
1 Oct 2025
17 Sept 2025 - 30 Sept 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
8653Tender.pdf
Tender Documents • 0.84 MB
BOQ_818806.xls
BOQ • 2.02 MB
8653Corridendum2.pdf
PDF • 0.25 MB
8653Corridendum1.pdf
PDF • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .