| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest on 03 Feb 2021 | |
| 2 | L2₹8.8 L+₹77,155 (9.56%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹9.3 L+₹1.3 L (15.6%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹9.4 L+₹1.3 L (16.0%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
28 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Faridkot
Garrison Engineer, Faridkot-151203 Punjab 01639-264982
Repair to Sunken, roof and other connected works in Zone A and B under AGE B/R (M) at Faridkot Mil Stn
2020_MES_408223_1
GE FRD-69/2020-21
Open Tender
Civil Works
Item Rate
180 days
Faridkot Mil Stn
Class E Category a i
8 documents required · 8 mandatory
₹500
Yes
GE Faridkot
₹20,000
Yes
4 Feb 2021
31 Dec 2020
30 Jan 2021
31 Dec 2020
28 Jan 2021
14 Jan 2021
60 days
Amount
M&L for Water proofing treatment to RCC sunken slab as specified below and as directed by Engineer-in-Charge:- (a) Rendering 15 mm thick in CM 1:3 using water proofing compound on raised verticle surface after demolition of PCC. (b) Cleaning the surface with wire brush/coir brush, removing loose material like dust particles, dirt etc. (c) Creating fillet covering of 50mm x 50mm with polymer modified mortar on the junction of slab and walls. (d) Apply first coat of two component modified polymer coating on the horizontal and verticle surface upto 300mm above wall surface (e) Provision of polyster reinforced coated net of 45 gm2, 2.5mm x 2.5mm immediately on above coating. (f) Apply second coat of two component modified polymer coating after 72 hrs upto 300mm above wall surface. (g) Laying Cement concrete 1:4:8 over the coating as per requirment. (h) Joining the saintary pipes with the water proofing tape having bridging ability of more than 1.5 mm. (j) Filling the gap between the wall opening and saintary pipe with non shrink cementatious grout complete as specified Manufacturer. (k) The treatment to be carried out by authorised applicator of Water Proofing Manufacture. Make:- Dr. Fixit/Fosroc/BASF/STP Limited. Note: (i) The treatment shall be carried out by approved authorised applicator as per the manufacturers instructions and as directed by the Engineer in charge. (ii) The Plan area of floor shall be considered for payment and provn of PCC in filling. (iii) WPC will be measured separately under relevant item of BOQ.
Demolition of concrete (un-reinforced) in roofs any thickness including plastering and leaping (whether full thickness removed or only part thereof) complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B-1 usin 20mm graded stone aggregate as in roof, foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Roof treatment to RCC roof as specified below as directed :- (a) Cleaning, washing of surface and removing all existing bitumen coatings completely with intense wire brushing or high speed water jet. Surface should be free from any loose paint, dust or grease. (b) All cracks upto 3mm at corner joints, channels and parapets should be treated with crack seal and bigger cracks, dmanged portions and hollow areas must be repaired with polymer modified cement mortar. (c) Apllying one coat of prime seal / Epoxy Primer/ Shali Urethane BTD white diluted with potable water in the ratio of 1:1 and apply @ 0.40 Kg/Sqm (0.20 Kg BTD + 0.20 Kg water) (d) Laying polyster reinforced fiber net / 50gsm Geotextile mesh upto 300mm on walls. (e) Applying three coat of Hydro Shield PUD micro fibre reinforced UP resistent polyurethane (solid content 68%) / Damp proof ultra UV stable fibre reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers (Solid content 55%) / Smart care PU magnum elastomeric water proofing coating based on hydrophobic plyuethane (Solid content 85%) / Single component elastomeric Liquid Membrane Shali Urethane BTD white/ coloured (Elongation 400% + 50, Solid contents > 80% & Specific gravity @ 30 OC 1.5 + 0.03) @ total 2.00 Kg per sqm in two coats for maintaining thickness of 1.5mm, with paint brush / roller upto 300mm on walls. Make : Dr Fixit/ Asian/ STP Limited
M&L Rendering 10mm thick in cement plaster in cement mortar 1:4 on roof, fair faces of brick work or concrete surfaces without using extra cement complete all as specified and directed by Engineer in Charge.
Demolition of brick work/stone masonry built in cement mortar including all quoins arches, pillars etc complete all as specified and directed by Engineer in Charge.
M&L for Brick work with fly ash bricks sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per item No 7 here-in-before but except bricks complete all as specified and directed by Engineer in Charge.
Dismantling terrazzo / glazed tiles in floor/hearth or wall tilling /skirting/dado including cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and directed.
S & F coloured Glazed ceramic tiles 450X300X7MM thick in vertical surface such as dado/skirting etc set and jointed in neat cement slurry and pointed in white or colour cement to match the shade over and including 10mm thick rendering in cement mortar 1:4 on brick or concrete surface complete all as specified and directed by Engineer in Charge.
S & F Non skid ceramic coloured tiles 7 to 8 mm thick Matt finish (Square/rectangular) area of each tiles exceeding 0.11 sqm but n.exc 0.18 sqm, as in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed in cement mortar (1:4) complete all as specified and directed by Engineer in Charge.
S & F Non skid ceramic coloured tiles 7 to 8 mm thick matt finish (Square/rectangular) area of each tiles exceeding 0.18 sqm but n.exc 0.38 sqm, as in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed in cement mortar (1:4) complete all as specified and directed by Engineer in Charge.
Taking down wooden/steel chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Sqm each including cutting holes of appropriate size in brick / concrete surfaces for insertion of PCC block for hold fasts complete all as specified & directed by Engineer-in- charge.
S&F solid wood moulded grain printed PVC door frame of size 50x95mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube, edges will be painted to match printed sheets in opening as per specification and drawings mentioned in MES schedule complete all as specified & directed by Engineer-in-Charge.
S&F Factory made solid PVC moulded door shutter with particle board core, 28 to 30mm thick (style) with 2, 4 or 6 raised panel design with 2mm thick Moulded Prelam PVC sheet on the front face & 2mm plain colour PVC on back face, supplying and fixing in frame at site as per specification and drawings complete all as specified and directed by Engineer-in-Charge.
S&F 100mm butt hinges medium weight, cold each rolled, mild steel complete all as specified and directed by Engineer-in-Charge.
S&F aluminium anodized tower bolts 150 mm long of extruded section fixed to doors with screws complete all as specified and directed by Engineer-in-Charge.
S&F aluminium anodized handles 150 mm long dia cast type fixed to doors with screws complete all as specified and directed by Engineer-in-Charge.
Dismantling of CI/PVC pipe alongwith fittings of 75/100/110mm dia,below or above GL or laid in floors or fixed to walls jointed in cement mortar and taking out complete all as specified and directed by Engineer in Charge.
S&F 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvant and fixed to walls Cutting holes in brick wall built in cement mortar for inserting holdfasts, depth of embedded portion not exceeding half brick (measured from the face of jamb into the wall) complete all as specified and directed by Engineer-in- charge.
S&F 75 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvant and fixed to walls Cutting holes in brick wall built in cement mortar for inserting holdfasts, depth of embedded portion not exceeding half brick (measured from the face of jamb into the wall) complete all as specified and directed by Engineer-in- charge.
S&F 110mm bore door type PVC (SWR) bends / shoe of any radius complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore door type PVC (SWR) bends / shoe of any radius complete all as specified and directed by Engineer-in-Charge.
S&F 100mm dia cast iron soil waste and vent pipe,sand cast in any length with or without ears with cement joints laid in trenches, in floors or fixed to walls complete all as specified and directed by Engineer in Charge.
S&F 75mm dia cast iron soil waste and vent pipe,sand cast in any length with or without ears with cement joints laid in trenches, in floors or fixed to walls complete all as specified and directed by Engineer in Charge.
S&F in repair 100mm cast iron bends,diminishing pieces or tapers laid in trenches or in floor or fixed to walls complete all as specified and directed by Engineer in Charge.
All as per item No 26 here in before but 75mm dia complete all as specified and directed by Engineer in Charge.
M&L in repairs PVC (SWR) Floor trap long neck 75 mm dia, with grating including jointing with solvent complete all as specified and directed by Engineer in Charge.
S&F in repairs Vitreous china squatting pan Orrisa pattern, size 580x440mm white with integral foot rests including necessary lime concrete and 100mm bore cast iron "P" or "S" trap long neck for connecting WC to branch piece with cement joints and 32mm dia PVC flush pipe, complete all as specified and directed by Engineer in Charge.
S&F in repair vitreous china wash down water closet pan (pedestel pattern) white in colour including connection pipe to union of flushing cistern, inlet and overflow pipes,connecting only to flushing cistern anti-syphonage pipe with PVC flush pipe of 32mm dia and plastic seat cover with mild steel chromoum plated hinging and 'P' or 'S' trap device including PVC health faucet complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair PVC low level flushing cistern white 10 litre capacity, valveless syphonic action type with float, handle complete all as specified and directed by Engineer-in-Charge.
S&F in repair Wash hand basin flat back 550x400mm vitreous china (white) with cantilever CI/Angle iron brackets embedded in concrete block including Brass chromium plated waste coupling 32mm bore, Waste pipe PVC 32mm bore and fixed in repairs complete all as specified and directed by Engineer in Charge.
S&F in repair PVC Connections 15 mm size with PTMT nuts of length 600 mm long Make 'Prayag' Cat Part No 324 or Equivalent complete all as specified & directed by Engineer-in-charge.
Taking up or down 15mm bore steel water tubing alongwith connections in any situation complete all as specified and directed by Engineer in Charge.
All as per item No 34 here-in-before but 20mm bore pipe complete all as specified and directed by Engineer in Charge.
S&F Mild steel galvanized tubing 15 mm bore medium grade with fittings to walls with hooks, ceiling or laid on floor complete all as specified and directed by Engineer in Charge.
Re-fixing old steel tubing and connections in new or old position of wall ceiling or floor 15mm bore of pipe complete all as specified and directed by Engineer in Charge.
S&F Mild steel galvanized tubing 20 mm bore medium grade with fittings to walls with hooks, ceiling or laid on floor complete all as specified and directed by Engineer in Charge.
Re-fixing old steel tubing and connections in new or old position of wall ceiling or floor 20mm bore of pipe complete all as specified and directed by Engineer in Charge.
S&F in repair Angle valves, fancy type, CP with long shank and cup ( concealed type ), screwed both ends for 15mm bore of iron pipe or for union and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair 20mm bore stop valve cast copper alloy chromium plated with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed by Engineer in Charge.
S&F in repair pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down, high pressure, with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts, screwed for 15mm bore of iron pipe and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair bib taps, fancy type CP, screwed for 15mm bore of iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair CP brass wall mixer, for mixing hot & cold water screwed for 15mm bore of iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair grating doom any dia of PTMT complete all as specified and directed by Engineer-in-Charge.
S&F in repair brass chromium plated shower rose 125mm size with swivel joints including fixing to steel pipe of 15mm bore complete all as specified and directed by Engineer in Charge.
S&F in repair rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 Ltr capacity hoisted and fixed in position all as specified including ball brass valves, high pressure, with polythene float and fly nut screwed for 20mm bore iron pipe complete all as specified and directed by Engineer in Charge.
S&F in repair rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacity hoisted and fixed in position all as specified including ball brass valves, high pressure, with polythene float and fly nut screwed for 20mm bore iron pipe complete all as specified and directed by Engineer in Charge.
Taking down cement plaster or terrazo from brick walls or concrete of any description,racking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer in Charge.
M&L Rendering 15 mm thick cement plaster in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished fair and even without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 10 mm thick cement plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished fair and even without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L preparation of newly plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion white/ tinted with a wall care putty finished surface over one coat of primer by hand roller complete all as specified and directed by Engineer in Charge.
M & L for preparation of newly plastered or unplastered surfaces of walls, soffits/facia of chajja/roof slab etc and applying two coats of cement base paint complete all as specified and directed by Engineer in Charge. Note : Curing of surface will be carried out as per Para 15.15.3 of SSR Part-I. Note :- A Sum of Rs. 5025.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 24 (Schedule of credit) of Tender Documents.
M/s Balvinder Singh Engineer and Contractors
M/S BSS AND SONS
NEW AMRITSAR CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .