Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹34.7 L+₹97,942 (2.91%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹41.6 L+₹7.9 L (23.6%)Rejected-Finance 112 AMBALA ROAD NARAINGARH AMBALA 134203 | NARAINGARH | AMBALA | HARYANA | 134203 | L3 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/s. Kansal Construction Co. L2 | J S CONSTRUCTION CO L3 | shakti construction L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge. | 912 | Sqm | 10 ₹9,120 | 32 ₹29,184 | 5 ₹4,560 Lowest |
| 2.00 | M&L for rendering CM (1:6) 10 mm thick on fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement up to Nine storey height bldg in and removing the debries outside the MOD land complete all as specified and directed by Engr In Charge. | 520 | Sqm | 150 ₹78,000 Lowest | 320 ₹1,66,400 | 150 ₹78,000 Lowest |
| 3.00 | M&L rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement up to Nine storey height bldg and removing the debries outside the MOD land complete all as specified and directed by Engr In Charge. | 262 | Sqm | 150 ₹39,300 Lowest | 299 ₹78,338 | 160 ₹41,920 |
| 4.00 | M & L rendering 5mm thick on ceiling in cement mortar 1:3 finished fair and even smooth without using extra cement etc built in cement mortar and removing the debries outside the MOD land complete all as specified and directed by Engr In Charge. | 130 | Sqm | 150 ₹19,500 | 235 ₹30,550 | 85 ₹11,050 Lowest |
| 5.00 | M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of primer incl 3mm thick elastomeric wall care putty on walls up to nine storey height building complete all specified and as directed by engr-in -charge. | 520 | Sqm | 30 ₹15,600 Lowest | 65 ₹33,800 | 40 ₹20,800 |
| 6.00 | M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper, including repairing of pot holes and cracks with putty, up to Nine storey height building complete all as specified and directed by Engr-in-Charge. | 4,550 | Sqm | 30 ₹1,36,500 | 45 ₹2,04,750 | 20 ₹91,000 Lowest |
| 7.00 | M&L for preparation on new or previously untreated wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over putty up to nine storey height building complete all as specified and directed by Engineer-in-Charge. | 262 | Sqm | 30 ₹7,860 Lowest | 45 ₹11,790 | 40 ₹10,480 |
| 8.00 | M&L for complete removal of existing old surface wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surface over putty up to nine storey height building complete all as specified and directed by Engineer-in-Charge. | 160 | Sqm | 40 ₹6,400 Lowest | 45 ₹7,200 | 60 ₹9,600 |
| 9.00 | M&L preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling up to nine storey height building complete and all as specified and directed by engr-in -charge. | 130 | sqm | 24 ₹3,120 | 22 ₹2,860 | 20 ₹2,600 Lowest |
| 10.00 | M & L preparation of old plastered surface and applying two coats of white wash on ceiling up to nine storey height building complete all as specified and directed by Engr-in -Charge. | 80 | sqm | 24 ₹1,920 | 20 ₹1,600 Lowest | 20 ₹1,600 Lowest |
Tender Value
₹47.6 L
EMD Value
₹95,120
Closing Date
8 Jul 2025, 6:00 pmClosed
GE (AF) SUBROTO PARK
GE (AF) Subroto Park, Delhi Cantt Delhi-110010
As described in Bill of quantities
2025_MES_713518_1
GE/SP/TOKEN-68/2024-2025
Open Tender
Civil Works
Item Rate
120 days
GE (AF) SUBROTO PARK
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) SUBROTO PARK
₹95,120
Yes
27 Aug 2025
11 Jun 2025
11 Jul 2025
11 Jun 2025
8 Jul 2025
26 Jun 2025
Amount
Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering CM (1:6) 10 mm thick on fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement up to Nine storey height bldg in and removing the debries outside the MOD land complete all as specified and directed by Engr In Charge.
M&L rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement up to Nine storey height bldg and removing the debries outside the MOD land complete all as specified and directed by Engr In Charge.
M & L rendering 5mm thick on ceiling in cement mortar 1:3 finished fair and even smooth without using extra cement etc built in cement mortar and removing the debries outside the MOD land complete all as specified and directed by Engr In Charge.
M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of primer incl 3mm thick elastomeric wall care putty on walls up to nine storey height building complete all specified and as directed by engr-in -charge.
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper, including repairing of pot holes and cracks with putty, up to Nine storey height building complete all as specified and directed by Engr-in-Charge.
M&L for preparation on new or previously untreated wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over putty up to nine storey height building complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing old surface wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surface over putty up to nine storey height building complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling up to nine storey height building complete and all as specified and directed by engr-in -charge.
M & L preparation of old plastered surface and applying two coats of white wash on ceiling up to nine storey height building complete all as specified and directed by Engr-in -Charge.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) up to nine storey height building complete all as specified and directed by Engr In Charge.
S&F in PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts up to nine storey height building etc complete all as specified and directed by Engr In Charge.
All as per item No 12 here in before But 75 mm dia.
S&F in repairs for 110 mm dia pvc pipe Stack clamps out of 50 mm by 5mm flat iron and 16mm dia round iron stays,enlcuding bolts and nuts and securing ends of stays to wall or roof up to nine storey height building complete all as specified and directed by Engr In Charge.
S&F in repairs for 75 mm dia pvc pipe Stack clamps out of 50 mm by 5mm flat iron and 16mm dia round iron stays,enlcuding bolts and nuts and securing ends of stays to wall or roof up to nine storey height building complete all as specified and directed by Engr In Charge.
S&F in repair PVC SWR bends 110 mm up to nine storey height building complete all as specified and directed by Engr In Charge.
S&F in repair PVC SWR bends 75 mm up to nine storey height building complete all as specified and directed by Engr In Charge.
S&F in repair 110 mm PVC SWR Junction single (Single T) provided with access door complete up to nine storey height building complete all as specified and directed by Engr In Charge.
S&F in repair 75 mm PVC SWR Junction single (Single T) provided with access door complete up to nine storey height building complete all as specified and directed by Engr In Charge.
S&F in repair PVC SWR Junction piece 110 mm double (Double T) provided with access door equal or unequal complete up to nine storey height building complete all as specified and directed by Engr In Charge.
S&F in repair PVC SWR Junction piece 75 mm double (Double T) provided with access door equal or unequal complete all as specified and directed by Engr In Charge.
S&F in repair 110 mm PVC SWR Branch piece, double (Single Y) complete all as specified and directed by Engr In Charge.
S&F in repair 75 mm PVC SWR Branch piece, double (Single Y) complete all as specified and directed by Engr In Charge.
S&F in repair PVC SWR vent cowl of size 110 mm complete all as specified and directed by Engr In Charge.
S&F in repair PVC SWR vent cowl of size 75 mm complete all as specified and directed by Engr In Charge.
Taking down steel tubing or removing from site of 15mm bore pipe up to nine storey height building all as specified and directed by Engineer-in-charge.
All as per item No 26 here in before but 20mm bore.
All as per item No 26 here in before but 25-32mm bore.
All as per item No 26 here in before but 50-80 mm bore.
S&F for 15mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
All as per item No 30 here in before but 20mm bore
All as per item No 30 here in before but 25mm bore
All as per item No 30 here in before but 32mm bore
All as per item No 30 here in before but 50-80 mm bore
S&F in repair gun metal globe valve or gate valve with mild steel iron wheel head, screwed both ends for iron pipe & fitted for 20 mm bore up to nine storey height building complete all as specified and directed by Engr In Charge.
All as per item No 35 here in before but 25 mm bore
All as per item No 35 here in before but 32 mm bore
All as per item No 35 here in before but 50 -80 mm bore
Taking down and Refixing in same opening Chowkats or frames with shutters (without taking off shutters from the frame) area not n.exc 1.50 sqm (including make good with CM 1:4 and hold fast) complete all as specified and directed by Engr In Charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm and not n.exc 4.0 sqm (including make good with CM 1:4 and hold fast) complete all as specified and directed by Engr In Charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area n. exc 1.5 sqm complete all as specified and directed
S&F factory made PVC door frame (Choukhat) of the size 50x47 mm with a wall thickness of 5mm (±0.25), made out of extruded 5mm (±0.25) thick PVC Sheet of Density 600 Kg /Cbm Manufactured by an ISO-9001 - 2015 certified Company , All three frame lengths reinforced with 19mmx19mm M.S. square tube cut at two corners and joined with 2nos. of 150mm long brackets of 15mmx15mm M.S. square tube or joint by fusion heat welding. The door frame shall be fixed to the wall using 8/100mm long M.S.Screws through the frame by using PVC fasteners. A minimum of 4nos of screws to be provided for each vertical member & minimum 2nos of horizontal member etc. complete as per manufacturers instructions complete all as specified and directed
S&F factory made (28-30) MM thick solid PVC door shutter consisting of frame made out of M.S tubes of size 19 X 19mm for style & 15x15mm for the top and bottom rails, M.S frame shall have a coat of metal primer of approved make and manufacture . M.S.frame shall be covered with heat moulded PVC ‘C’ channel made from 5mm (±0.25) thick sheet of Density 600 Kg /Cbm manufactured by an ISO- 9001-2015 certified company, 50mm width to form styles and 5mm (±0.25) thick and 75 mm wide PVC sheet for the top rail, lock rail and bottom rail on either side of the panel.complete all as specified and directed
S&F 150 mm long Aluminium anodised, barrel tower bolts of ex- truded section and fixed complete all as specified and directed by engr-in -charge.
S&F 150mm long aluminium handle cast type polished bright complete all as specified and directed by engr-in -charge.
S&F 100 mm long butt hinges medium weight, stenless steel, and fixed complete all as specified and directed by engr-in -charge.
Supply only liquid water proofing compund only complete all as specified and directed by Engr In Charge.
Demolition of cement concrete in sunken portion in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-Charge.
M&L for Providing and making fillet of 75mmx75mm in size with cement concrete in 1:2:4 in sunken portion, complete all as specified and directed by Engr In Charge.
M&L for Refilling Lime concrete with brick aggregate (Course) in lime mortar1:3, in the sunken with the help of proper tools & equipments & plants complete all as specified and as directed by Engineer-in-Charge.
M&L for Providing and making cement concrete in 40mm thickness in 1:2:4 type B0 (using 12.5mm graded stone aggregate) mixing water proofing compound Complete in sunken upto the below level of tiling complete all as specified and as directed by Engineer-in-Charge. Note : Water proofing compound shall be measured and paid separate item
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M&L Glazed ceramic coloured tiles in vertical surface 300X 200X 6-7 /450x300x7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl back plaster 10 mm thick in cm 1:4 complete all as specified and directed by Engr In Charge.
M&L for non skid ceramic joint free coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.11 Sqm but n. exc 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in CM(1:6) complete all as specified and directed by Engneer-in-Charge.
Supply and fixing in repair for vitreous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed.
Taking down & refixing vitreous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, excluding fixing bolts, flushing cistern and flush pipe complete all as specified and directed.
S&F in repair PVC SWR floor trap including jointing with solvent cement 75 mm dia complete up to nine storey height building complete all as specified and directed by Engr In Charge.
S&F in repairs10 ltr capacity PVC flushing cistern coloured with accessories Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete and specified and directed by engr-in -charge.
Taking down & refixing 10 ltr capacity PVC flushing cistern coloured with accessories Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete and specified and directed by engr-in -charge.
S & F in repairs for 125mm dia stainless steel grating doom with waste hole for waste pipe ( minimum weight 40 gram) complete all as specified and directed by Engr In Charge.
S & F in repairs 15mm CP bib tap fancy type copper alloy with crutch or butterfly handle , screwed down, screwed for iron pipe etc complete all as specified and directed by Engr In Charge.
Taking down & refixing 15mm CP bib tap fancy type copper alloy with crutch or butterfly handle , screwed down, screwed for iron pipe etc complete all as specified and directed by Engr In Charge.
S&F in repairs chromium plated shower rose 125 mm size with or without swivel joints complete all as specified and directed by Engr In Charge.
M&L in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engr In Charge.
S&F in repair CP stop valve /angle valves, cast copper alloy, fancy type, chromium plated with long shank & cup (concealed type) with crutch or butterfly handle, screwed both ends for iron pipe of 15 mm bore complete all as specified and directed by Engr-In-Charge.
S&F in repairs CP tubular Towel rail , 20 mm dia, D Type 600mm long between flanges brass chromium plated with screws and cleats, (Minimum weight 190 gms) complete all as specified and directed by Engr In Charge.
S&F in repairs soap dish / Paper Holder stainless steel fixed to plugs with chromium plated brass screws etc complete all as specified and directed by Engr-in- Charge
S&F 15mm dia PVC Connection 450 mm long with nuts complete all as specified and directed by Engr In Charge.
S&F in repairs vitreous china wash hand basin bowl type of size 550mm x 400mm white, flat back including angle iron brackets including PVC waste pipe of 32mm dia of suitable length, and 32mm dia brass waste fitting complete all as specified complete all as specified and directed by Engr In Charge.
Taking down & refixing vitreous china wash hand basin of size 550mm x 400mm white, flat back including angle iron brackets including PVC waste pipe of 32mm dia of suitable length, complete all as specified and directed by Engr In Charge.
S&F as in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engr In Charge.
S&F in repair glass shelf assembly consisting of 5.5 mm thick sheets glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engr-In-Charge.
S&F in repair corner glass shelf with bracket complete all as specified and directed by Engineer-in-charge.
S&F in repairs fancy type 15mm dia Brass CP wall mixer/basin hole mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed by Engineer-in-charge.
S & F in repairs 32mm dia Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap complete all as specified and directed by Engr In Charge.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed by Engr In Charge.
Demolition reinforced cement concrete of roofs, floors (other than ground floors), beams, staircases, landing, chajjas, RCC Jali and similar suspended work (reinforcement cut as required to facilitate demolition) complete up to nine storey height building complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete nominal mix 1:2:4, type B-1 using (20mm graded stone aggregate in slabs supported on walls, beams and column in floors,roofs,landings, balconies, canopies, deck slabs and in shelves and the like complete including formwork complete all as specified and directed by Engr-In-Charge.
S& F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire(annealed) not less than 0.9mm dia upto nine storey complete all as specified and directed by Engr In Charge.
M&L for Removing plant including roots by dismantaling of brick work PCC/RCC including necessary scaffoilding any type in any location/position i.e roof , parapet wall near pipes etc and applying acid after removing roots for preventing the regrowth and making good of disturbed portion using PCC 1:2:4 type B0 & 10mm thick plaster in CM 1:3 size of disturbed portion 150 x 150 x 200mm complete up to nine storey height building complete all as specified & directed by Engr - In - Charge.
S&F as in repair for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work complete all as specified and directed by Engr-In-Charge.
S&F for Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by engr-in -charge.
S&F Mild steel, plain black sheet 1.00mm thick in wall cladding, steel gates & similar work, cut to size, holes punched; including round headed screws, clout nails or rivets & fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
M&L Preparation of new /old steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide/ zinc chromate complete all as specified and directed by Engr In Charge.
S&F as in repair for plain galvanized sheet 0.8 mm thick and 300 mm wide to covering of crumple/expansion joint/gaps on vertical/horizontal surface, steeped finishind or fixing screw up to nine storey height building etc complete all as specified and directed by Engr In Charge.
S&F as in repair for plain galvanized sheet 0.8 mm thick and 450 mm wide to covering of crumple/expansion joint/gaps on vertical/horizontal surface, steeped finishind or fixing screw up to nine storey height building etc complete all as specified and directed by Engr In Charge.
S&F as in repair for plain galvanized sheet 0.8 mm thick and 1000 mm wide to covering of crumple/expansion joint/gaps on vertical/horizontal surface, steeped finishind or fixing screw up to nine storey height building etc complete all as specified and directed by Engr In Charge.
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring for independent board on 3pin 5 Amps socket outlet with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 2.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel sunkun box powder coated of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade IS-694 FRLScable with stranded copper conductor of size 2.5 Sq mm (Nominal area) complete all as specified. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
S&F switch piano 16 amps flush type single pole one way suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 2 in 1, 5 pin 16 amps flush type suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of ceiling roses, surface bakelite 65x50mm 3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed by Engineer-In- Charge.
Supply and fixing single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 A complete all as specified and directed by Engineer-In- Charge.
Taking down of light fittings of any wattage and any type from site and keeping safe on store for refixing or taking into credit complete all as specified and directed by Engineer-In- Charge.
Labour for Refixing only wall mounted LED fitting,four feet long , 20 watt,230 Volts, diffused optics ,etc complete with all accessories , connecting up with three core twisted flexible copper conductor cable from ceiling rose to fitting and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting, 4000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with three core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Taking down including disconnecting the electric connection of exhaust fan and dismantling blades and cleaning the whole assembly including marking MES No complete all as specified and directed
Fixing only Exhaust fan received from item No 100 above and connecting up including fastner and provision of suitable size of copper cable from connector of fans to ceiling rose complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable submain wiring of alluminium two runs of any size cable including batten/conduit complete etc and making good disturbed surfaces complete all as specified and directed.
M & L in replacement for submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS multistranded copper conductor 1100 volts grade IS:694 marked cable for earth continuty conductor drawn through existing PVC rigid non metallic conduit , medium grade or on surface in new conduit ,medium grade,ISI marked(not less than 20 mm) as per site requirement complete with all acessories such as bend,elbow etc complete all as specified and directed. ( Note - 2 Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable(earth) ang one run of PVC conduit 20 mm dia will be measured as one unit for payment purpose.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed by Engr -in-Charge.
M&L for taking down existing geyser carefully of any capacity without damaging from bathroom and to be kept in safe custody untill completion of finishing work and re-fixing the same after completion of work, including any type of repairing reqiured on it for making the Geyser in full serviceable condition complete all as specified and as directed by Engr in charge.
M/s. Kansal Construction Co. (BID ID -3342065)
J S CONSTRUCTION CO (BID ID -3351291)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .