Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.7 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹85.9 L+₹1.3 L (1.51%)Rejected-Finance | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹89.2 L+₹4.5 L (5.33%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹89.6 L+₹5.0 L (5.88%)Rejected-Finance FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | L4 | Rejected-Finance Other than being lowest | |
| 5 | L5₹92.1 L+₹7.5 L (8.80%)Rejected-Finance NOT AVAILABLE | L5 | Rejected-Finance Other than being lowest |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
7 Feb 2022, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
PROVISION OF STANDBY DG SET OF 200 KVA WITH LT PANEL FOR EM INSTALLATION PROVISION OF DEFICIENT STANDBY POWER SUPPLY FOR LIFT TO CERTAIN BUILDINGS AT OLD AND NEW NAVY NAGAR PROVISION OF STANDBY POWER SUPPLY FOR ENTIRE PERIMETER WALL NAVY NAGAR UNDER
2022_MES_500419_1
8269/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) Navy Nagar
Class C
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) Navy Nagar
₹1.5 L
Yes
12 Mar 2022
8 Jan 2022
9 Feb 2022
8 Jan 2022
7 Feb 2022
31 Jan 2022
8 Jan 2022 - 29 Jan 2022
Amount
Supply, installation, commissioning & testing diesel engine driven generating set mounted on four wheel trolley, totally enclosed type, silent operation with canopy of capacity 200 KVA/160 KW 415 Volts, 50 C/S, AC, 3 phase 4 wire system at power factor of 0.8 lagging all as per IS- 4722/2001, DG set mounted on common base plate and directly coupled through flexible coupling of diesel engine with cushy foot mountings (anti vibration) pad in and including acoustic insulated encloser/canopy with noise level less 75 db at 01 metre distance from DG set, AMF panel for automatic operation on mains failure complete in accordance with latest norms of pollution control board & having following provisions :- (a) Alternator (bush less) shall be design for an output of 200 KVA at full load for continuos rating at 0.80 PF AC 3 phase 4 wire 415 Volts 50 C/S with 1500 RPM speed, self excited, self regulated, screen protected, drip proof construction with insulation class 'H' with two end shield ball/roller bearing with damper winding in each pole faces as per IS-4722 or BS 2613-1970 complete all as specified and directed. (b)Diesel Engine :- Diesel Engine water cooled of Suitable BHP with electric start suitable to drive above alternator independently, coupled directly through flexible coupling, multi cylinder four stroke, 1500 RPM industrial type as per BS-649 or IS-1601 with A1 electronic governor suitable to regulate speed of DG set from No load complete with fuel tank of capacity as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories etc all as specified and directed.
(c) Control Panel : - Control panel of DG set shall comprising of indicator lamps LED type, hours meter/RPM indicator, lub oil pressure gauge, water temperature gauge, oil temp gauge & fuel level indicator safety control for engine shut off (trip with visual indication) for low lube oil pressure, safety control for engine shut off (trip with visual indication) for high water temperature, safety control (trip with visual indication) for low fuel level with protection of short circuit/over load and auto shut down.
(iv) Turn-Table :- 2Nos Angle Rings 50 X 6mm with Male Female pipe Bushes with Locking Bolt 36mm. (v) Draw-Bar :- Triangular Draw-Bar, Detachable Type made of M.S Channel 75X40mm. (vi) Towing Arrangement :- Spring Loaded Steel Towing Hook of 36mm round. (vii) Floor Sheet :- Floor fully covered with 6mm MS sheet (viii) Landing Jacks :- 4 Nos Landing Jacks fitted on four corners of the Trailer (ix) Roof :- Covered with GI sheet 2mm thick and suitable size of iron structure and expanded all around to provide robust protection form weather/rains and should be detachable type for easy dismantling during maint/repair of DG set. (x) Carrying capacity :- 4 Ton (Approx.)
(xi) Tyre Assembly :- 4Nos New Tyres Assembly size 7.50 X 16 Nylon any Std Make available CEAT, Apollo, JK. (xii) MS cable drums for XLPE insulated 120 sqmm 3.5 core (120 mtr length) and XLPE insulated 50 sqmm single core(120 mtr length) each with handle for closing and expansion. (xiii) Finshing & Painting :- Finishing with Grinding and one coat Red-Oxide (Primer) and 2 coats of Super Synthetic Enamel Paint. (Colour of paint as directed) (xiv) Fittings :- Necessary Fittings Like 4Nos Light Reflectors, 02 Nos Number Plates. Note :- (i) The amount for all items mentioned in specification and details and fabrication works are inclusive in the quoted rate. (ii) Testing of DG set to be carried out in presence of E/M Officer detailed by the department. Cost of fuel and load bank for 12 hours testing deemed in quoted rate.
Supply and installation, testing and commissioning of diesel engine driven generating set of capacity 200 KVA output at NTP with AMF control panel, 415 Volts, 50 C/S AC, 3 phase 4 wire at power factor of 0.8 lagging all as per IS- 4272/2001, DG set mounted on common base plate and directly coupled through flexible coupling of diesel engine with cushy foot mountings (anti vibration) pad in and including acoustic insulated encloser/canopy with noise level less 75 db at 01 metre distance from DG set, “AMF panel for automatic operation on mains failure complete in accordance with latest norms of pollution control board & having following provisions” (a) Alternator (bush less) shall be design for an output of 200 KVA at full load for continuos rating at 0.80 PF AC 3 phase 4 wire 415 Volts 50 C/S with 1500 RPM speed, self excited, self regulated, screen protected, drip proof construction with insulation class 'H' with two end shield ball/roller bearing with damper winding in each pole faces as per IS-4722 or BS 2613-1970 complete all as specified and direcetd. (b)Diesel Engine :- Diesel Engine water cooled of suitable BHP and with electric start suitable to drive above alternator independently, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with A1 electronic governor suitable to regulate speed of DG set from No load complete with fuel tank of capacity as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters etc all as specified and direcetd.
Supply and installation, testing and commissioning of diesel engine driven generating set of capacity 50 KVA output at NTP with AMF control panel, 415 Volts, 50 C/S AC, 3 phase 4 wire at power factor of 0.8 lagging all as per IS- 4272/2001, DG set mounted on common base plate and directly coupled through flexible coupling of diesel engine with cushy foot mountings (anti vibration) pad in and including acoustic insulated encloser/canopy with noise level less 75 db at 01 metre distance from DG set, AMF panel for automatic operation on mains failure complete in accordance with latest norms of pollution control board & having following provisions” (a) Alternator (bush less) shall be design for an output of 50 KVA at full load for continuos rating at 0.80 PF AC 3 phase 4 wire 415 Volts 50 C/S with 1500 RPM speed, self excited, self regulated, screen protected, drip proof construction with insulation class 'H' with two end shield ball/roller bearing with damper winding in each pole faces as per IS-4722 or BS 2613-1970 complete all as specified and direcetd. (b)Diesel Engine :- Diesel Engine water cooled of suitable BHP and with electric start suitable to drive above alternator independently, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with A1 electronic governor suitable to regulate speed of DG set from No load complete with fuel tank of capacity as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters etc all as specified and directed.
Supply, testing and commissioning XLPE insulated, PVC innersheathed, un-armoured electric power cables (heavy duty) with stranded copper conductor, 1100 volts grade, of size 120 sq mm 3.5 core including suitable size of copper lugs complete all as specified and directed.
Supply, testing and commissioning XLPE insulated, PVC innersheathed, un-armoured electric power cables (heavy duty) with stranded copper conductor, 1100 volts grade, of size 50 sq mm single core including suitable size of copper lugs complete all as specified and directed.
Supplying and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 300 sqmm 3.5 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles/lugs complete all as specified and directed.
All as per Item No-6 here in before but of size 185 sqmm, 3.5 core.
All as per Item No-6 here in before but of size 70 sqmm, 3.5 core.
All as per Item No-6 here in before but of size 50 sqmm, 3.5 core.
All as per Item No-6 here in before but of size 35 sqmm, 3.5 core.
All as per Item No-6 here in before but of size 16 sqmm, 4.0 core.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out for laying of cables, in any type of soil complete all as specified and as directed. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm with excavated soil complete all as specified and as directed.
Removing excavated material from the site of work and transporting out of Station/site of work suitable to the contractor complete all as specified and as directed.
Supplying, filling, spreading, leveling in layers and well ramming dry river sand around cable in trenches for cable cushioning complete all as specified and as directed.
Cutting existing road surface or hard standing, bituminous topping 15 cm but n exc 30cm. girth for laying of pipes/ cables and making good distrubed surface to match with existing complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable covers LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and as directed.
Material and labour for fixing of old interlocking paver tiles/blocks of any sizes recovered form item SI. No. 12 including laying over 50 mm thick sand bed compacted complete all as specified and as directed.
Material and labour for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of size 250 X 250 mm, having compressive strength of 35N/Sqmm, zig-zag (uni-paver) shape in flooring tested as per IS : 15658-2006, with and including laying over 50 mm thick sand bed compacted complete all as specified and as directed.
Material and labour for High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 100 mm dia for road crossing of cable or for cable protection of cable above/under ground surface all as specified and directed.
All as per Item No-20 here in before but of size 63 mm dia.
All as per Item No-20 here in before but of size 50 mm dia.
Material and labour for fabrication of Panel, double door made out of 2mm thick CRCA sheet, CPRI approved, indoor type suitable for 3 phase, 4 wire, 415 volts, with Copper busbar strip of 600 amps capacity with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting incl foundation 60 cms above the ground level in PCC 1:3:6 type C2 complete all as specified and as directed consisting of following :-
Incomer : (a) DPX3 630, MCCB 400 Amps, 4 Pole, 36 kA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 422007 of Make- Legrand or equivalent in Siemens/ABB/Schneider.
Outgoings : (b) DPX3 250, Thermal magnetic release MCCB 250A, 25KA, 4P. Make : Legrand : Cat ref : 420019 -01 Nos or equivalent in Siemens/Schneider/ABB
(c) DPX3 250, Thermal magnetic release MCCB 160A, 25KA, 4P. Make : Legrand : Cat ref : 420057 -01 Nos or equivalent in Siemens/Schneider/ABB
(d) DPX3 160, MCCB 100 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 420055 of Make- Legrand or equivalent in Siemens/ABB/Schneider.
(e) DPX3 160, MCCB 63 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 420053 of Make- Legrand or equivalent in Siemens/ABB/Schneider.
(f) Digital Ammeter - 01 Nos
(g) Digital Voltmeter Make - 01 Nos
(h) Phase indicator lamp R,Y & B - Set of 3
(j) Coper Bus bar 600 Amps rated of suitable size - Set
Material and labour for LT FPB, weather proof, vermin proof, double door made out of 3mm thick CRCA sheet, CPRI approved, out-door type (IP-54) suitable for 3 phase, 4 wire, 415 volts, with Coper busbar strip of 400 amps capacity with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting incl foundation 60 cms above the ground level in PCC 1:3:6 type C2. complete all as specified and as directed consisting of following :-
Incomer : (a) DPX3 250, Thermal magnetic release MCCB 200A, 25KA, 4P. Make : Legrand : Cat ref : 420218 -01 Nos or equivalent in Siemens/Schneider/ABB
Outgoings : (b) DPX3 160, MCCB 160 Amps, 4 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 420017 of Make- Legrand or equivalent in Siemens/ABB/Schneider
(c) DPX3 160, MCCB 63 Amps, 4 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 06 Nos, Cat No- 420013 of Make- Legrand or equivalent in Siemens/ABB/Schneider
(d) Digital Ammeter Make - 01 Nos
(e) Digital Voltmeter Make - 01 Nos
(f) Phase indicator lamp R,Y & B - Set of 3
(g) Coper Bus bar 400 Amps rated of suitable size - Set
Material and labour for LT FPB, weather proof, vermin proof, double door made out of 3mm thick CRCA sheet, CPRI approved, out-door type (IP-54) suitable for 3 phase, 4 wire, 415 volts, with Coper busbar strip of 200 amps capacity with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting incl foundation 60 cms above the ground level in PCC 1:3:6 type C2 complete all as specified and as directed consisting of following :-
Incomer : (a) DPX3 160, Thermal magnetic release MCCB 160A, 25KA, 4P. Make : Legrand : Cat ref : 420047 -01 Nos or equivalent in Siemens/Schneider/ABB
Outgoings : (b) DPX3 160, MCCB 63 Amps, 4 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 08 Nos, Cat No- 420013 of Make- Legrand or equivalent in Siemens/ABB/Schneider
(c) Digital Ammeter Make - 01 Nos
(d) Digital Voltmeter Make - 01 Nos
(e) Phase indicator lamp R,Y & B - Set of 3
(f) Coper Bus bar 400 Amps rated of suitable size - Set
Material and labour for LT FPB, weather proof, vermin proof, double door made out of 3mm thick CRCA sheet, CPRI approved, out-door type (IP-54) suitable for 3 phase, 4 wire, 415 volts, with Coper busbar strip of 100 amps capacity with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting incl foundation 60 cms above the ground level in PCC 1:3:6 type C2 complete all as specified and as directed consisting of following :-
Incomer : (a) DPX3 160, Thermal magnetic release MCCB 63A, 25KA, 4P. Make : Legrand : Cat ref : 420013 -01 Nos or equivalent in Siemens/Schneider/ABB
Outgoings : (b) DPX3 160, MCCB 40 Amps, 4 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 02 Nos, Cat No- 420012 of Make- Legrand or equivalent in Siemens/ABB/Schneider
(c) Digital Ammeter - 01 Nos
(d) Digital Voltmeter - 01 Nos
(e) Phase indicator lamp R,Y & B - Set of 3
(f) Coper Bus bar 400 Amps rated of suitable size - Set
Material and labour for cement concrete 1:4:8 type D2 (using 40mm grade stone aggregate) as in foundations, filling and mass concrete finished fair and even comlpete all as specified and as directed
Supply & install Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 metres long) and applying one coat of steel primer and one coat of aluminium paint and pole serial numbers as per existing number including earth work for excavation, foundation PCC work and copping of pole complete all as specified and directed by Engr-in-charge.
Supply and fixing street light bracket bend to shape and made as required of 50 mm dia, length 1.2 mtr GI pipe light grade fixed to pole and Material and labour for fixing with the help of two set of flat iron clamp, nuts, bolts and washer for fixing of street light fitting on the steel tubular pole complete all as specified and as directed.
Material and labour for pole mounted thermoplastic cable junction box for street light with IP-66/67 protection, halogen free and weather proof with metric knockouts for cable entry for outdoor installation of size 155mm x 210mm x 92mm with front door opening system including terminals for one incoming and two outgoing cables of size upto 16 sqmm 4 core, one MCB DP 6 Amp 240V AC with mounting clamp of flat iron, nut, bolt and washers complete all as specified and directed. Make of J/B - HENSEL cat No.KF 1616B or equivalent make of L&T and Sintex.
Supply and fixing LED 100 Watts LED street light made up of pressure die cast aluminium housing with high power LED as lighting source with toughened glass top cover, top opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge protection device, including connecting light fittings with three core copper wire from cable looping box mounted on bottom part of street light pole all as specified and directed. Make- Cat part No. ENDURAPEARLMAGNUMSL100WLED757PASYTOTGAST of Havells and equivalent model of C&S/Philips/Crompton/Wipro.
Material and labour for fabrication of LT Panel, double door made out of 3.15mm thick CRCA sheet, CPRI approved, outdoor type suitable for 3 phase, 4 wire, 415 volts, with Coper busbar strip of 400 amps capacity with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 50x50x5 mm thick, powder coated painting incl foundation 60 cms above the ground level in PCC 1:3:6 type C2 all as specified & Directed consisting of following :-
Incomer : (a) DPX3 160, MCCB 100 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 4200 55 of Make- Legrand or equivalent in Siemens/ABB/Schneider.
Outgoings : (b) DPX3 160, MCCB 63 Amps, 4 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 03 Nos, Cat No- 4200 13 of Make- Legrand or equivalent in Siemens/ABB/Schneider.
(c) Digital Ammeter Make - 01 Nos
(d) Digital Voltmeter Make - 01 Nos
(e) Phase indicator lamp R,Y & B - Set of 3
(f) Coper Bus bar 400 Amps rated of suitable size - 1Set
Material and labour for earthing with copper earth plate electrode 600mm x 600mm x 3 mm burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth not less than 1.5 mtr below ground level connected to the connecting copper strip 20 x 3 mm and including GI pipe 40 mm dia light grade for protection to the extend of 7.5 mtr as earthing lead by means of copper nuts, bolts as per connecting to equipment with provn charcol and salt complete all as per electric plate No 5 of SSR Part-1 including PCC chamber with RCC cover watering arrangement with GI pipe 20 mm dia medium grade and MS funnel, including excavation and earth work and returning, filling in including ramming and removal of surplus soil and testing on completion complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel earth plate electrode (600x600x6) mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level connected to GI earth strips 32 x 6 mm by means of nut bolt and washer made out of galvanized iron or steel connected to panel and RCC cover slab of size (450x450x60) mm with one handle made out of 8 mm dia round bar 20mm bore GI pipe medium grade for watering funnel wire mess and charcoal or coke of alternative layer, of 15 cm including necessary earth work complete all as shown in electrical plate No.5 of SSR part-1 and testing complete all as specified and directed.
Test point terminal block made of gunmetal /phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hex head screw fixed complete all as specified and as directed.
OM SAI POWER SYSTEMS
Ashirwad Contractor and Supplier
BOB ENTERPRISES
SHREE JAGDISH FURNITURE CO.
AGRAWAL ASSOCIATES
BRITE INDUSTRIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .